Shanghai Hailong Instrument Factory

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
ModelHLT-300G
Nitrogen Purity>99.999%
Hydrogen Purity>99.999%
Air QualityOil-free, Dry, Triple-Purified
N₂/H₂ Flow Range0–300 mL/min
Air Flow Range0–2000 mL/min
H₂ Output Pressure0–0.4 MPa (factory-set at 0.3 MPa)
N₂ Output Pressure0–0.5 MPa (factory-set at 0.4 MPa)
Air Output Pressure0–0.4 MPa
Power Supply220 V ±10%, 50 Hz ±5%
Max. Power Consumption400 W
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-dust
Dimensions (W×D×H)460 × 440 × 370 mm
Weight40 kg
Warranty1-year system warranty, 3-year electrolyzer warranty
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
ModelHLT-500G
Nitrogen Purity>99.999%
Hydrogen Purity>99.999%
Air QualityOil-free, Dry, Triple-Purified
N₂/H₂ Flow Range0–500 mL/min
Air Flow Range0–5000 mL/min
H₂ Output Pressure0–0.4 MPa (factory-set at 0.3 MPa)
N₂ Output Pressure0–0.5 MPa (factory-set at 0.4 MPa)
Air Output Pressure0–0.4 MPa
Power Supply220 V ±10%, 50 Hz ±5%
Max Power Consumption500 W
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-dust
Warranty1-year full unit, 3-year electrolyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
ModelHLA-300G, HLA-500G
Gas PurityN₂ > 99.997%, H₂ > 99.999%
Output FlowN₂/H₂: 0–300 mL/min (HLA-300G), 0–500 mL/min (HLA-500G)
Air0–2000 mL/min (HLA-300G), 0–5000 mL/min (HLA-500G)
Output Pressure0–0.5 MPa (factory-set at 0.4 MPa) for all gases
DesignIntegrated monoblock chassis
Control ModeOn/Off switch control
Power Supply220 V ±10%, 50 Hz ±5%
Max Power750 W (HLA-300G), 850 W (HLA-500G)
Dimensions460 × 310 × 670 mm
Weight47 kg
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-dust ambient
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
ModelHLT-300II
Nitrogen Purity>99.999%
Hydrogen Purity>99.999%
Air QualityOil-free, desiccated, triple-purified
N₂/H₂ Flow Range0–300 mL/min
Air Flow Range0–2000 mL/min
H₂ Output Pressure0–0.4 MPa (factory-set at 0.3 MPa)
N₂ Output Pressure0–0.5 MPa (factory-set at 0.4 MPa)
Air Output Pressure0–0.4 MPa
Power Supply220 V ±10%, 50 Hz ±5%
Max. Power Consumption400 W
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-dust
Dimensions (W×D×H)460 × 440 × 370 mm
Weight40 kg
Warranty1-year full unit, 3-year electrolytic cell
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
ModelHLT-500II
Gas OutputsN₂, H₂, Air
N₂ & H₂ Purity>99.999%
Air QualityOil-free, Dry, Triple-Purified
N₂/H₂ Flow Range0–500 mL/min
Air Flow Range0–5000 mL/min
N₂ Output Pressure0–0.5 MPa (factory-set at 0.4 MPa)
H₂ Output Pressure0–0.4 MPa (factory-set at 0.3 MPa)
Air Output Pressure0–0.4 MPa
Power Supply220 V ±10%, 50 Hz ±5%
Max. Power Consumption500 W
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-dust
Warranty1-year system warranty
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHLT
OriginShanghai, China
ModelHLT-300II, HLT-500II
Gas PurityN₂ > 99.997%, H₂ > 99.999%, Air: oil-free, dried, triple-purified
Output FlowN₂/H₂: 0–300 mL/min (HLT-300II) / 0–500 mL/min (HLT-500II)
Air0–2000 mL/min (HLT-300II) / 0–5000 mL/min (HLT-500II)
Output PressureH₂/N₂/Air: 0–0.5 MPa (factory-set at 0.4 MPa)
Power Supply220 V ±10%, 50 Hz ±5%
Max. Power450 W
Dimensions (W×D×H)460 × 310 × 670 mm
Weight39 kg
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-dust ambient