BrandHaileong
OriginShanghai, China
Instrument TypeDual-beam UV-Vis spectrophotometer
DetectorPhotomultiplier tube (PMT)
Wavelength Range190–1100 nm (UV1801/UV1800PC/TU1810), 325–1100 nm (UV1600PC-V7)
Spectral Bandwidth1 nm (UV1801), 1.8 nm (UV1800PC/TU1810), 4 nm (UV1600PC-V7)
Wavelength Accuracy±0.3 nm (UV1801), ±0.5 nm (others)
Wavelength Repeatability0.1–0.2 nm
Stray Light≤0.05% T at 220 nm and 360 nm
Photometric Accuracy≤±0.3% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A)
Photometric Repeatability≤±0.15% T (0–100% T), ±0.001 A (0–0.5 A), ±0.002 A (0.5–1 A)
Baseline Flatness±0.002 A
Drift±0.001–0.002 A/h at 500 nm
Optical DesignCzerny-Turner monochromator with 1200 lines/mm grating
Light SourcesDeuterium lamp (D₂) and tungsten-halogen lamp (W) with automatic switching
Sample CompartmentAccommodates cuvettes from 5 mm to 100 mm pathlength
Data InterfaceUSB port for data export
DisplayLCD screen
Power SupplyAC 90–240 V, 50 Hz
Dimensions470 × 370 × 240 mm
Weight13 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaileong
ModelUV-2204
Optical SystemDouble-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range200–1000 nm
Spectral Bandwidth4 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.3 nm
Photometric Accuracy±0.3% T
Photometric Repeatability≤0.2% T
Stray Light≤0.2% T @ 220 nm & 360 nm
Baseline Stability±0.002 A/h @ 500 nm
Display Resolution0.1 nm
Measurement ModesTransmittance (T), Absorbance (A), Concentration (C), Factor (F)
Light SourcesImported Deuterium Lamp & Tungsten-Halogen Lamp (Auto-Switching)
MonochromatorCzerny-Turner (CT) Type
InterfaceUSB 2.0
Sample CompartmentAccommodates Cuvettes from 5 mm to 100 mm Pathlength
Power SupplyAC 90–240 V, 50 Hz
Dimensions470 × 370 × 200 mm
Weight13 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
Model723 / 723N / 7230G / X3
Wavelength Range325–1000 nm
Spectral Bandwidth2–4 nm
Wavelength Accuracy±1–±2 nm
Stray Light≤0.2%T @ 360 nm
Photometric Accuracy±0.3–±0.5%T
Photometric Repeatability≤0.2%T
Baseline Stability±0.002 A/h @ 500 nm
Wavelength Resolution0.1 nm
Detector TypePhotomultiplier Tube (PMT)
Optical DesignCzerny-Turner Monochromator
Light SourceImported Tungsten-Halogen Lamp
DisplayLCD with 0.1 nm wavelength resolution
Sample CompartmentAccepts 5–100 mm cuvettes
Measurement ModesTransmittance (T), Absorbance (A), Concentration (C), Factor (F)
Auto-zero & Auto-100%T CalibrationYes
InterfaceUSB (for optional XP-based analysis software)
Power SupplyAC 90–240 V, 50 Hz
Dimensions470 × 370 × 200 mm
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
Model721 / 721N / X1
Wavelength Range325–1000 nm
Spectral Bandwidth4–5 nm
Wavelength Accuracy±2–±3 nm
Stray Light≤0.2% T @ 360 nm
Photometric Accuracy±0.5% T
Photometric Repeatability≤0.2% T
Stability±0.002 A/h @ 500 nm
Detector TypePhotomultiplier Tube (PMT)
Optical SystemSelf-collimating monochromator with 1200 lines/mm grating
Light SourceImported tungsten-halogen lamp
Measurement ModesTransmittance (T), Absorbance (A), Concentration (C), Factor (F)
Sample ChamberAccommodates cuvettes from 5 mm to 50 mm pathlength
Dimensions400 × 310 × 160 mm
Weight6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
Model722 / 72S / 722N / X2
Price RangeUSD 0–799
Optical DesignDual-wavelength
Detector TypePhotomultiplier Tube (PMT)
Wavelength Range325–1000 nm
Wavelength ScanningMotorized automatic wavelength selection
Spectral Bandwidth4–5 nm
Wavelength Accuracy±2 nm
Stray Light≤0.2% T at 360 nm
Photometric Accuracy±0.5% T
Photometric Repeatability≤0.2% T
Baseline Stability±0.002 A/h at 500 nm
Light SourceImported tungsten-halogen lamp
MonochromatorCzerny-Turner self-collimating design
Sample CompartmentAccommodates cuvettes from 5 mm to 50 mm pathlength
InterfaceUSB 2.0
Operating ModesTransmittance (T), Absorbance (A), Concentration (C), Factor (F)
Zero AdjustmentFully automated OA and 100% T calibration
Dimensions400 × 310 × 160 mm
Weight6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHailong
OriginShanghai, China
ModelTU-1901AS / TU-1901B / TU-1901plus / TU-1901S / TU-1901
Optical SystemDual-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range190–1100 nm
Spectral Bandwidth0.1–5 nm (model-dependent)
Wavelength Accuracy±0.1 nm (@ 656.1 nm D₂ line), ±0.3 nm (full range)
Stray Light≤0.02% T (at 220 nm with NaI
Photometric Accuracy±0.002 A (0–0.5 A), ±0.3% T (0–100% T)
Photometric Repeatability±0.001 A (0–0.5 A), ±0.15% T (0–100% T)
Baseline Flatness±0.0005 A
Baseline Drift±0.0005 A/h
Noise±0.0003 A (500 nm, 0 A, 2 nm bandwidth)
Display8-inch true-color capacitive touchscreen
Data OutputUSB 3.0 ×3, Ethernet, Wi-Fi, Bluetooth, Email/PDF/Excel export