Empowering Scientific Discovery

Shanghai Hanyao Instrumentation & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMitsubishi Chemical
OriginJapan
ModelCA-310 (Coulometric & Volumetric Modes)
Display8.4-inch color touchscreen (Chinese UI)
Electrode OptionsMembrane-free or membrane-type generator electrode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITSUBISHI CHEMICAL
OriginJapan
ModelGT-310
Display8.4-inch color touchscreen
Channelsup to 4 simultaneous potentiometric and/or Karl Fischer titration channels
Modularitysupports solvent dispensers, autosamplers, analytical balances, and printers
ComplianceDesigned for GLP/GMP environments
PricingAvailable upon request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVemex YMC
OriginJapan
ModelK-Prep FC750
Application LevelIndustrial-Scale Preparation
Instrument TypeMedium- to Low-Pressure Preparative LC System
Flow Rate Range1–750 mL/min
Flow Accuracy±2% (at ≥75 mL/min)
Flow Precision≤0.5% RSD
Maximum Operating Pressure10 MPa
Wavelength Resolution1 nm
Data Acquisition Rate0.5 s
ComplianceGMP-Compliant Design, IQ/OQ-Ready, CSV-Aligned Software Architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYMC
OriginJapan
ModelK-Prep LAB
Application LevelLaboratory-scale
Instrument TypeMedium-to-Low Pressure Preparative LC System
Flow Rate Range1–100 mL/min (LAB-100S/G) / 1–300 mL/min (LAB-300S/G)
Flow Accuracy±2% (≥10 mL/min for LAB-100
Maximum Operating Pressure15 MPa (LAB-100 series) / 10 MPa (LAB-300 series)
UV Detection Wavelength Range195–370 nm
Gradient CapabilityDual-pump high-precision gradient formation
Sample Loop Capacity50 mL or 100 mL (configurable)
Injection VolumeUp to 25 mL via syringe (expandable with pump-assisted loading)
System ControlPC-based PLC-integrated software with audit trail
ComplianceDesigned for GLP/GMP environments per FDA 21 CFR Part 11 and ISO/IEC 17025-aligned validation protocols
Column ID Compatibility20–200 mm
Packing Particle Size Support5–10 µm
Dead VolumeMinimized via motor-driven ball valves and low-ID stainless steel/FEP fluidic pathways
Power SupplyAC 100–240 V, 50/60 Hz
Power Consumption0.6 kW (single-pump) / 1.1 kW (dual-pump)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYMC
OriginJapan
ModelK-Prep EX
Application LevelIndustrial-Scale Preparation
Instrument TypeMedium-to-Low Pressure Preparative LC System
Flow Rate Range30–3000 mL/min (EX03KG)
Flow Accuracy±2% (at ≥300 mL/min for EX03KG
Flow Precision0.5% RSD
Maximum Operating Pressure10 MPa
Wavelength Range195–600 nm
Wavelength Repeatability±1 nm
UV/VIS DetectorFixed-wavelength or scanning, 1 nm resolution
Fraction Collection5-channel valve-switched system with drain line
Solvent Selection4-channel (2 × 2 configuration)
Control InterfaceFA PC-based control (non-hazardous area), PLC-integrated architecture
Software ComplianceDeveloped per MHLW Japan’s “Guideline on Validation of Computerized Systems (CSV)”
Electrical Supply3-phase AC 200 V, 50/60 Hz (4.0–23 kW depending on model)
Construction MaterialsHigh-purity SUS316 stainless steel tubing (ID: 7.5 mm to 22.1 mm), explosion-proof rated enclosures (ATEX / IECEx / Class I Div 1 compliant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYMC
OriginJapan
ModelK-Prep FC
Application LevelIndustrial Preparative
Instrument TypeMedium-Low Pressure Preparative LC
Flow Rate Range1–750 mL/min
Flow Rate Reproducibility≤±2% (≥75 mL/min)
Maximum Pressure10 MPa
Wavelength Range195–600 nm
Gradient CapabilityIsocratic & Gradient (FC750G / FC1500G variants)
DetectionUV/VIS
Pump TechnologyDual-plunger linear cam, pulse-free delivery
Column ID Compatibilityφ50–φ150 mm
Software ComplianceCSV-aligned per MHLW Japan “Guideline on Computerized Systems in GxP Environments”
Regulatory AlignmentSupports IQ/OQ protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYMC
OriginJapan
ModelLC-Forte/R
Application LevelLaboratory-scale
Instrument TypeMedium- to Low-Pressure Preparative LC System
Flow Rate Range0.1–50.00 mL/min
Flow Accuracy±2% (at ≥5 mL/min)
Flow Precision≤0.5% RSD
Maximum Pressure30 MPa
Wavelength Range190–400 nm (programmable, 1 nm step)
Wavelength Repeatability±0.5 nm
Baseline Noise≤1.3 × 10⁻⁴ AU (254 nm, 1 s response)
Data Acquisition Rate0.5 s per point
Detection ModesUV-Vis (triple-wavelength simultaneous), optional RI detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYMC
OriginJapan
ModelDAU-50
Maximum Operating Pressure10 MPa
Internal Diameter50 mm
Column Length700 mm
Bed Length Range100–400 mm
Axial Compression MechanismHydraulic/Pneumatic Piston with Continuous Dynamic Load
Optional Slurry Delivery System Capacity2 L
Instrument TypeMedium-Low Pressure Preparative Liquid Chromatography System
Application LevelLaboratory-Scale Purification
Added to wishlistRemoved from wishlist 0
Add to compare
Brand908 Devices
OriginUSA
Product TypeImported Microfluidic ESI Source
ModelZipChip® Platform
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0