| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MF-50 |
| Maximum Sample Capacity | 51 g |
| Weighing Resolution | 0.002 g |
| Moisture Content Accuracy | ±0.20% (for samples >1 g), ±0.05% (for samples >5 g) |
| Moisture Display Precision | 0.05% / 0.1% / 1% |
| Drying Temperature Range | 50–200 °C (1 °C increments) |
| Heating Source | Halogen lamp (400 W, straight-tube, ~5000 h lifetime) |
| Measurement Modes | Standard / Auto / Rapid / Timer / Manual |
| Moisture Expression Modes | Relative moisture / Absolute moisture / Dry basis / Wet basis |
| Data Storage | 50 measurement results |
| Predefined Programs | 10 |
| Interface | RS-232 |
| Software | WinCT-Moisture (graphical real-time analysis) |
| Sample Pan Diameter | Ø85 mm (optional Ø110 mm) |
| Power Supply | AC 100–120 V (3 A) or 200–240 V (1.5 A), 50/60 Hz, ~400 W |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | ~6 kg |
| Operating Environment | 5–40 °C, <85% RH |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C min (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV), pH: 0.001 pH (0–20 pH), Photometric: 0.003 Abs (0–1 Abs) |
| IP Rating | IP55/IP65 (when enclosure door is closed and latched) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ALT-SED |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Domestic |
| Model | ALT-1-C Online |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Enclosure Rating | IP55/IP65 (with door locked), optional higher ratings available |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Method | Coulometric Titration (Karl Fischer) |
| Detection Principle | Electrochemical generation of iodine via constant-current electrolysis |
| Detection Range | 1 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Accuracy | ±2 µg (for <100 µg), ±0.2% (for >100 µg) |
| Sample Introduction | Heated oven coupling with carrier gas (N₂ or dry air) |
| Temperature Control | 50–300 °C (adjustable in 1 °C increments) |
| Electrolytic Cell | Dual-platinum electrode, sealed glass cell with molecular sieve drying tube |
| Compliance | ASTM E203, ISO 760, ISO 15512, USP <921>, EP 2.5.12, GLP-compliant data integrity features |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-1 Online Titration Analyzer for Lithium Battery Manufacturing |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT-1 Online Titration Analyzer for Electroplating Baths |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Povidone K30-Specific |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Online Copper Sulfate and Nickel Ion Analyzer for Electroplating Lines |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AKF-V6 |
| Pricing | USD 6,800 (FOB Shanghai) |
| Titration Mode | Fully Automated Volumetric Titration |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Volumetric & Coulometric Capable via Optional Module) |
| Measurement Resolution | 0.1 ppm |
| Water Content Range | 10 ppm – 100% (0.001% – 100% H₂O) |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (with 20 mL burette) |
| Repeatability | ≤ 0.3% RSD |
| Linearity Correlation Coefficient | ≥ 0.999 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Control Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records (expandable via USB export) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Product Type | Online Potentiometric Titration Analyzer |
| Model | ALT-1 |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory equivalence and GLP-compliant industrial deployment |
| Measurement Principle | Automatic potentiometric titration (pH and redox endpoint detection) |
| Accuracy | ±3% relative deviation vs. reference manual titration |
| Sampling Frequency | Configurable up to once every 30 minutes |
| Output Interface | 4–20 mA, Modbus RTU/TCP, Ethernet/IP |
| Environmental Rating | IP65 enclosure |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AT-1 Advanced |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55 to +125 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | 0.8 mV/h |
| Input Impedance | >1 × 10¹² Ω |
| Bias Current | <1 × 10⁻¹² A |
| Titration Volume Resolution | 1 µL (with 20 mL burette) |
| Electrode Interfaces | Composite, Reference, Indicator, and Temperature Electrode Ports |
| GLP Compliance | User authentication, audit trail, electrode & titrant logging, PDF report export, method versioning |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | MT-V6 Redox |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000, Resolution: 0.001 pH |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Burette Precision | 20 mL standard burette / 1 µL, 10 mL optional burette / 0.5 µL |
| Potential Range | ±2000 mV, Resolution: 0.1 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | AKF-CH6 |
| Price | USD 9,500 (approx.) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Online Titration Analyzer |
| Model | ALT-1 |
| Application Domain | Electroplating Chemical Process Monitoring & Automated Reagent Dosing |
| Measurement Principle | Potentiometric/Colorimetric Endpoint Detection with Programmable Burette Dispensing |
| Compliance Framework | Designed for GLP/GMP-aligned process documentation, supports audit-ready data logging per FDA 21 CFR Part 11 requirements (electronic signatures, user access control, immutable event logs) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ALT-SED |
| Pricing | Available Upon Request |