- All
- Favorite
- Popular
- Most rated
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Titration Control | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity framework |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM Series |
| Heating Method | Halogen Lamp |
| Measurement Principle | Loss-on-Drying (LOD) via Halogen Radiant Heating |
| Weighing Range | 110 g |
| Weighing Resolution | 0.0001 g to 0.005 g (model-dependent) |
| Temperature Range | Ambient to 199 °C |
| Drying Modes | Standard / Rapid / Gentle |
| Preheating Time | < 60 s to 50–180 °C |
| Data Storage | 15 measurement records |
| Programs Stored | Up to 16 user-defined methods |
| Interface | RS-232 serial port |
| Compliance | GLP/GMP/GCP, ISO/IEC 17025-aligned operation, meets JJG 1084–2013 (Chinese National Metrological Verification Regulation for Moisture Analyzers) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Model | CT-1Plus (Color-Endpoint Detection Enabled) |
| Measuring Range | Potential: ±1024 mV |
| pH | 0–14 pH |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV (potential), 0.001 pH |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Range | ±2000 mV |
| Resolution | 0.1 mV |
| Absolute Accuracy | ±0.2 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Model | CT-1PLUS |
| pH Range | 1–14 |
| Potential Measurement Range | ±2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.2 mV |
| Titration Resolution (20 mL burette) | 0.001 mL |
| Titration Resolution (10 mL burette, optional) | 0.0005 mL |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 1–14 |
| Potential Display Accuracy | ±0.2 mV |
| Potential Resolution | 0.1 mV (within ±2000 mV range) |
| Burette Precision | 0.001 mL (20 mL standard burette) |
| Burette Resolution | 0.0005 mL (10 mL optional burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AKF-3N Coulometric Karl Fischer Moisture Titrator |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MT-V6 Acid-Base Titrator |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Burette Precision | ±1 µL (20 mL standard burette) / ±0.5 µL (10 mL optional burette) |
| Potential Range | ±2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Accuracy | ±0.2 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-C2 |
| Titration Method | Fully Automatic Coulometric Titration |
| Water Content Range | 3 µg – 199 mg (as H₂O mass) |
| Resolution | 0.1 µg |
| Measurement Precision | ±1 mV |
| Repeatability | ≥99% RSD |
| Linearity Correlation Coefficient | ≥0.995 |
| Polarization Voltage Adjustment Range | ±10 mV |
| Electrode Configuration | Dual-electrode Coulometric Cell (Generator & Indicator) |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 10 test records |
| External Power Option | 12 V DC input compatible with vehicle power systems and rechargeable Li-ion batteries |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Dedicated for Ibuprofen Capsules |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Moisture Analyzer |
| Model | AKF-3N |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Detection Range | 1 µg – 200 mg H₂O |
| Sensitivity | ≤ 0.1 µg H₂O |
| Compliance | ASTM D6304, ISO 760, USP <921>, GB/T 4117–2022 |
| Data Interface | USB 2.0 |
| Electrode Configuration | Dual-platinum indicator electrodes + membrane-separated generator electrode |
| Stirring System | Integrated variable-speed magnetic stirrer |
| Cell Design | Hermetically sealed titration cell with desiccant airlock |
| Software Features | GLP-compliant audit trail, user-level access control, automatic calibration logging, CSV export |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AKF-CH6 Coulometric |
| Price | USD 9,500 (FOB Shanghai) |
| Category | Coulometric Moisture Analyzer / Electrochemical Instrument / Karl Fischer Titrator |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 3 µg – 30 mg H₂O |
| Measurement Accuracy | ≤ 0.3% (relative) |
| Minimum Dispensing Resolution | 1/2000 of burette volume |
| Electrolysis Current | Auto-controlled, up to 400 mA |
| Detection Sensitivity | 1 µg H₂O |
| Typical Quantitation Range | 10 µg – 10 mg H₂O |
| Maximum Titration Rate | 0.6 mg H₂O/min |
| Endpoint Detection | Visual LED indicator + audible buzzer + automatic stop |
| Display | 5-digit LED |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MT-V6 Non-Aqueous Titrator |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000, Resolution: 0.001 pH |
| Meter Accuracy | ±0.1 mV |
| Meter Resolution | 0.1 mV |
| Burette Precision | 20 mL standard burette / 1 µL, 10 mL optional burette / 0.5 µL |
| Potential Range | ±2000 mV, Resolution: 0.1 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Universal Automatic Potentiometric Titrator |
| Application Scope | General-purpose with HF-optimized colorimetric endpoint detection |
| pH Measurement Range | 1–14 |
| Potentiometer Display Accuracy | ±0.2 mV |
| Potentiometer Resolution | 0.1 mV (range: ±2000 mV) |
| Titration Precision | 0.001 mL (standard 20 mL burette) |
| Titration Resolution | 0.0005 mL (optional 10 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Model | MT-V6 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Range | 0.000–14.000 (Resolution: 0.001 pH) |
| Potential Range | ±2000.0 mV (Resolution: 0.1 mV) |
| Potential Accuracy | ±0.1 mV |
| Burette Precision | 1 µL (20 mL burette, standard), 0.5 µL (10 mL burette, optional) |
| Data Storage Capacity | 1000 sample records with timestamp, temperature, ID, and audit trail |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Type | Coulometric Moisture Analyzer |
| Detection Limit | 0.01 µg H₂O |
| Water Content Range | 0.001–100% |
| Electrolysis Current Range | 1–400 mA (resolution: 0.1 mA) |
| Compliance | Fully GMP/GLP-Compliant Software Architecture |
| User Access Control | Three-Tier Role-Based Authentication |
| Data Integrity | Full Audit Trail, Electronic Signature Support, 21 CFR Part 11 Ready |
| Sample Forms | Liquids, Solids, Gases, and Insoluble Matrices (with optional accessories) |
| Method Storage | Unlimited Customizable Titration Methods |
| Drift & Blank Management | Adaptive Algorithms for High-Accuracy Background Compensation |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Model | CT-1Plus (Fully Automated) |
| Measurement Range | Potential: ±1024 mV |
| pH | 0–14 pH |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.01 mV (potential), 0.001 pH (pH) |
| Titration Precision | (±0.3 mV ±1 digit) over 3 h |
| Burette Precision | 0.001 mL (20 mL standard burette), 0.0005 mL (10 mL optional burette) |
| Temperature Range | 0–100 °C (±0.1 °C) |
| Display | 7.0″ TFT LCD touchscreen with real-time titration and first-derivative curve overlay |
| Compliance | GLP/GMP-compliant data handling, audit-trail-capable user management, electrode & burette calibration history logging |
| Interfaces | RS-232C, USB, Ethernet, stirrer control port |
| Ambient Conditions | 5–35 °C, <85% RH (non-condensing) |
| Power | AC 100–240 V, 50/60 Hz, ~30 W |
| Dimensions (Main Unit) | 250 × 360 × 330 mm (W×D×H) |
| Stirrer Unit | 120 × 200 × 230 mm |
| Weight | 10 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | AT-1 Advanced |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55.0 to +125.0 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.8 mV/h |
| Titration Resolution | 0.1 mV |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Model | CT-1P |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | Potential: ±2000 mV |
| pH | 0–14 |
| Temperature | −5 to 125 °C |
| Meter Accuracy | ±0.3% of full scale |
| Meter Resolution | Potential: 0.1 mV |
| pH | 0.001 |
| Temperature | 0.1 °C |
| Titration Accuracy | (±0.3 mV ±1 digit) over 3 h |
| Titration Resolution | ±2000 mV range, 0.1 mV resolution, ±0.2 mV absolute accuracy |
| Minimum Dispensing Volume | 10 µL |
| Maximum Dispensing Volume | 100 µL |
| Stirring Speed | 200 rpm |
| Drop Interval | 1000 ms |
| Endpoint Detection Mode | First Derivative (dE/dV), Threshold Set at 200 mV/mL |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame–Graphite Furnace Hybrid AAS |
| Monochromator | Fixed-grating with selectable slits |
| Optical System | Double-beam |
| Detector | Solid-state CCD array |
| Background Correction | Simultaneous D₂-lamp and Self-reversal (SR) correction |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Resolution | 0.2 nm |
| Cu Detection Limit (Flame) | ≤0.004 µg/mL |
| Cu Characteristic Concentration (Flame) | ≤0.025 µg/mL per 1% absorption |
| Precision (RSD, Cu, A > 0.8) | ≤0.5% |
| Baseline Drift | ≤0.002 A / 30 min |
| Graphite Furnace Max Ramp Rate | ≥3000 °C/s |
| Graphite Furnace Temp Range | Ambient to 3000 °C |
| Cd Characteristic Mass | ≤1 pg |
| Cu Characteristic Mass | ≤10 pg |
| Graphite Furnace Precision (RSD) | ≤3% (Cd, Cu) |
| Lamp Turret | 6-position automatic |
| Auto-sampler Options | 45- or 85-position |
| Gas Control | Dual-path (in-tube / out-tube) inert gas regulation |
| Safety Systems | Real-time flame status monitoring, gas pressure sensors (air, acetylene, N₂O), auto-shutdown on flame failure/flashback, power-interruption cutoff, overtemperature/coolant-flow interlock |
| Dimensions | 700 × 550 × 440 mm |
| Weight | 80 kg |
| Power Requirement | 220 V AC, 6000 W nominal, transient peak up to 8 kW |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RI201H |
| Instrument Type | Refractive Index Detector (RID) |
| Refractive Index Range | 1.00–1.75 |
| Detection Sensitivity | 1/4 RIU/FS to 512 × 10⁻⁶ RIU/FS |
| Linear Range | 6 × 10⁻⁴ RIU |
| Zero Adjustment | Digital auto-zero with optical zero compensation |
| Auto-Zero Range | ≥ ±1 × 10⁻⁴ RIU |
| Auto-Zero Resolution | ≥ 1 × 10⁻⁸ RIU |
| Drift Adjustment Range | 0–6 × 10⁻⁶ RIU |
| Drift Resolution | 3 × 10⁻⁸ RIU |
| Response Time Settings | 3 modes (Fast / Standard / Slow) |
| Noise Level | ≤ 2.5 × 10⁻⁹ RIU (Standard response) |
| Integrator Output | 0–1.024 V (Sensitivity: 2 mV per 1 × 10⁻⁶ RIU) |
| Recorder Output | 0–10 mV/FS |
| Input Signals | Flush / Zero / Mark / Polarity |
| Output Alarms | Intensity Alert / Overflow Alert / Mark Pulse |
| Thermostatic Control | 35 °C (±0.1 °C) |
| Flow Cell Volume | 8 µL |
| Max. Flow Rate | 10 mL/min (with aqueous mobile phase) |
| Max. Operating Pressure | 0.05 MPa |
| Total System Dead Volume | ~590 µL (pre-cell: ~60 µL |
| post-cell | ~520 µL) |
| Wetted Materials | Stainless Steel (316), PTFE (Teflon®), Fused Silica |
| Power Supply | 100–220 V AC, 50/60 Hz |
| Power Consumption | 60 W |
| Dimensions (W×D×H) | 400 × 260 × 150 mm |
| Weight | 13 kg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | CT-1Plus |
| Instrument Type | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 1–14 |
| Meter Display Accuracy | ±0.1 mV |
| Meter Resolution & Range | ±2000 mV, 0.1 mV resolution |
| Titration Accuracy | 0.001 mL (20 mL burette, standard) |
| Titration Resolution | 0.0005 mL (10 mL burette, optional) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Moisture Range | 0.001–100% w/w |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispense Volume | 1/2000 of burette capacity |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Generator/Electrolysis Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TCL-1B |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Cement Chloride Ion Analysis Dedicated |
| Measurement Range | mV: −2000 to +2000 mV |
| pH | 0.000–14.000 |
| Temperature | −55.0 to +125.0 °C |
| Meter Accuracy | ±0.5% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Precision | ≤0.8 mV/h |
Show next