| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Accuracy | ±0.5 µL (20 mL burette) |
| Titration Control | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant architecture with audit trail, 3-tier user access control, FDA 21 CFR Part 11–ready data integrity framework |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM Series |
| Heating Method | Halogen Lamp |
| Measurement Principle | Loss-on-Drying (LOD) via Halogen Radiant Heating |
| Weighing Range | 110 g |
| Weighing Resolution | 0.0001 g to 0.005 g (model-dependent) |
| Temperature Range | Ambient to 199 °C |
| Drying Modes | Standard / Rapid / Gentle |
| Preheating Time | < 60 s to 50–180 °C |
| Data Storage | 15 measurement records |
| Programs Stored | Up to 16 user-defined methods |
| Interface | RS-232 serial port |
| Compliance | GLP/GMP/GCP, ISO/IEC 17025-aligned operation, meets JJG 1084–2013 (Chinese National Metrological Verification Regulation for Moisture Analyzers) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-C2 |
| Titration Method | Fully Automatic Coulometric Titration |
| Water Content Range | 3 µg – 199 mg (as H₂O mass) |
| Resolution | 0.1 µg |
| Measurement Precision | ±1 mV |
| Repeatability | ≥99% RSD |
| Linearity Correlation Coefficient | ≥0.995 |
| Polarization Voltage Adjustment Range | ±10 mV |
| Electrode Configuration | Dual-electrode Coulometric Cell (Generator & Indicator) |
| Current Control Accuracy | ±1 mA |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 10 test records |
| External Power Option | 12 V DC input compatible with vehicle power systems and rechargeable Li-ion batteries |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Dedicated for Ibuprofen Capsules |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 3 µg – 30 mg H₂O |
| Measurement Accuracy | ≤ 0.3% (relative) |
| Minimum Dispensing Resolution | 1/2000 of burette volume |
| Electrolysis Current | Auto-controlled, up to 400 mA |
| Detection Sensitivity | 1 µg H₂O |
| Typical Quantitation Range | 10 µg – 10 mg H₂O |
| Maximum Titration Rate | 0.6 mg H₂O/min |
| Endpoint Detection | Visual LED indicator + audible buzzer + automatic stop |
| Display | 5-digit LED |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Moisture Range | 0.001–100% w/w |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispense Volume | 1/2000 of burette capacity |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Generator/Electrolysis Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Heating Oven |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Titration Control Precision | 0.01 µg H₂O |
| Electrode Type | Electrolytic Electrode |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 1 ppm – 100% water content |
| Resolution | ±0.1 µA |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 1/2000 of burette volume |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Titration Control Precision | 0.1 mA |
| Polarization Voltage | Not applicable (coulometric mode) |
| Electrolysis Electrode | Integrated dual-platinum electrode system |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage | Internal non-volatile memory with timestamped records |
| Sample Positioning | 8-position automated rotary sample carousel |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 0.001–100.00% (10 ppm – 100% w/w) |
| Resolution | 1 ppm |
| Measurement Precision | ±1 mV (endpoint detection) |
| Minimum Dispensing Volume | 1 µL |
| Repeatability | RSD ≤ 0.5% (at 20 mg H₂O) |
| Linearity of Titration Response | ≥ 0.998 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette | 20 mL Long-Life Automatic Burette |
| Burette Accuracy | ±0.001 mL |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Data Storage Capacity | 100 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 µL |
| Moisture Content Range | 0.001–100% w/w |
| Accuracy | ≤0.15% RSD |
| Minimum Dispensing Volume | 0.2 µL |
| Titration Control Precision | 1.0 µL |
| Electrode Configuration | Dual Platinum Electrode |
| Endpoint Detection | Bipotentiometric (Double-Pt) |
| Average Analysis Time | <3 min per sample |
| Data Storage Capacity | 10 method/sample records |
| Operating Ambient Humidity | ≤80% RH |
| Power Supply | 110–220 V AC, 50 Hz |
| Dimensions (L×W×H) | 320 × 240 × 410 mm |
| Net Weight | 5.5 kg |
| Auxiliary Functions | Titration Delay, Endpoint Hold Delay |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AKF-V6 Lactose-Specific |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Precision | ±0.5 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Moisture Range | 1 ppm to 100% (w/w) |
| Resolution | 1 µV (electrochemical detection) |
| Accuracy | >99.7% at 1000 µg water |
| Repeatability | >99.7% at 1000 µg water |
| Linearity (R²) | 0.999 |
| Polarization Voltage Range | ±10 mV |
| Electrode System | Dual Platinum Electrolysis Electrodes |
| Current Control Precision | 0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |
| Compliance | Designed for GMP/GLP environments with audit trail, user-level access control, and 21 CFR Part 11–ready software architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer with Integrated Sample Evaporator |
| Water Content Range | 3 µg – 199 mg H₂O (0.01 µg resolution) |
| Measurement Accuracy | ≥99.7% at 1000 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity Correlation Coefficient | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrolysis Electrode Configuration | Dual-electrode coulometric cell |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 220 V / 50 Hz, 300 W |
| Data Storage | Internal non-volatile memory with timestamped method and result logging |
| Sample Introduction | Heated headspace evaporation with dry carrier gas (N₂ or air), dual-mode sampling (puncture-seal + screw-cap vial) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 100 ppm – 100% w/w |
| Titration Resolution | 0.05 mL |
| Burette Capacity | 10 mL (user-supplied) |
| Electrode | Dual Platinum Electrode |
| Polarization Voltage | −40 mV |
| Current Sensitivity | 1 µA |
| Endpoint Detection | Amperometric (fixed-current threshold with 10–15 s delay) |
| Stirring | Built-in infinitely variable-speed electromagnetic stirrer |
| Valve System | 3-way solenoid-driven bidirectional valve |
| Tubing Material | Chemically resistant polymer |
| Operating Temperature | 5–35 °C |
| Relative Humidity Limit | ≤80% RH |
| Waste Disposal | Integrated automatic waste ejection system |
| Compliance | Designed for GLP-compliant environments |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | 11521.1310.100 |
| Price | USD 105 (ex-works) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT Series Karl Fischer Online Moisture Analyzer |
| Pricing | Upon Request |
| Titration Mode | Fully Automated |
| Instrument Type | Coulometric & Volumetric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 1 ppm to 100% w/w water content |
| Measurement Resolution | Potentiometric: ±0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH) |
| Photometric | ±0.003 Abs (0–1 Abs) |
| Titration Accuracy | Volumetric dosing precision ≤1 µL (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3 µg – 199 mg (H₂O mass) |
| Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg pure water) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Repeatability | ±0.3% (for samples containing >1 mg H₂O) |
| Linearity Correlation Coefficient | 0.999 |
| Electrolysis Electrode | Membrane-separated dual-platinum coulometric electrode |
| Titration Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–62 Hz |
| Data Storage Capacity | Unlimited (internal flash memory with timestamped audit trail) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator (with Coulometric option support) |
| Moisture Range | 10 ppm – 100% H₂O (0.001–100 wt%) |
| Resolution | 0.1 ppm |
| Precision | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Burette Delivery Accuracy | ±0.5 µL (20 mL burette) |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | GLP-compliant data handling, 21 CFR Part 11–ready audit trail, ISO/IEC 17025–aligned operation |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Moisture Range | 0.001–100% w/w |
| Measurement Resolution | 0.01 µg |
| Accuracy | >99.7% (at 1000 µg water) |
| Minimum Dispensing Volume | 1/2000 of burette capacity |
| Titration Control Precision | 0.01 µg |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Analyzer |
| Measurement Principle | Microcoulometric Titration (Electrolytic Bromine Generation) |
| Bromine Number Range | 0–300 g Br/100 g sample |
| Bromine Index Range | 1–1000 mg Br/100 g sample |
| Resolution | 0.01 mg Br |
| Accuracy | ±3% (±0.3 mg Br when bromine index < 1 mg Br/100 g) |
| Repeatability | ±3% |
| Titration Control Precision | ±3% (±0.3 mg Br at low-level detection) |
| Power Supply | 220 V AC / 50 Hz |
| Data Storage Capacity | Internal memory supporting >1000 test records |
| Compliance Standards | SH/T 0630, GB/T 11136, ASTM D1492 |
| Endpoint Detection | Potentiometric (dual-platinum electrode system) |
| Electrolyte Compatibility | Benzene-free electrolyte formulations |
| Display | 7-inch color TFT touchscreen interface |
| Average Analysis Time | ≤60 seconds per sample |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.01 µg H₂O |
| Water Content Range | 3 µg – 199 mg H₂O |
| Accuracy | ≥99.7% (at 1000 µg H₂O) |
| Minimum Sample Injection | 3 µg H₂O |
| Repeatability | ≤0.3% RSD |
| Linearity (r²) | ≥0.998 |
| Polarization Voltage Adjustment Range | ±10% |
| Electrode Type | Electrolytic Electrode |
| Titration Control Precision | 0.01 µg H₂O |
| Power Supply | 300 W, 220 V / 50 Hz |
| Data Storage | Supported |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 1.0 µL |
| Moisture Range | 0.001–100% w/w |
| Accuracy (RSD) | ≤1.0% |
| Minimum Dispensing Volume | 5 µL (20 mL High-Precision Burette) |
| Repeatability | ±3.0% RSD |
| Linearity (r²) | ≥0.99 |
| Polarization Voltage Adjustment Range | 0–120 mV |
| Burette Capacity | 20 mL |
| Titration Control Precision | ±5.0 µL |
| Power Supply | 110–240 V AC, 50–63 Hz |
| Data Storage | Internal Memory with Auto-Save Function |
| Brand | HOGON |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm to 100% (0.001–100% H₂O) |
| Resolution | 0.1 ppm |
| Accuracy | RSD ≤ 0.3% (at 1500 µL reagent consumption) |
| Minimum Dispensing Volume | 0.5 µL (20 mL burette) |
| Repeatability | ±0.3% |
| Linearity (r²) | ≥0.999 |
| Polarization Voltage Range | 0–120 mV |
| Burette Options | 20 mL / 10 mL |
| Titration Precision | ±0.5 µL (20 mL burette) |
| Power Supply | 110–240 V AC, 50–65 Hz |
| Data Storage Capacity | 200 test records |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | AKF-3N |
| Titration Mode | Fully Automatic |
| Resolution | 0.01 µg (H₂O mass) |
| Water Content Range | 3 µg – 100 mg |
| Measurement Accuracy | 0.01 µg |
| Minimum Dispensing Volume | 10 µL |
| Repeatability | 99.7% |
| Linearity (R²) | 0.999 |
| Electrode Type | Electrolytic Electrode |
| Current Control Precision | ±0.1 mA |
| Power Supply | 110–240 V AC, 50–61 Hz |
| Data Storage Capacity | 200 test records |