Add to compare
BrandAnalab
OriginFrance
Device TypeSub-boiling Distiller
Capacity12 × 125 mL
ConstructionPFA-coated (400 µm thickness)
ComplianceISO Class 1 Cleanroom Certified
Heating Uniformity±0.5 °C across surface
Operating PrincipleControlled sub-boiling evaporation with condensate isolation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAir Science
OriginUSA
ModelPurair Basic
Cabinet TypeSingle-Face Ductless Fume Hood
ConstructionSteel-and-Wood (Epoxy-Coated Steel Frame with Optional Polypropylene Interior)
Voltage Options110 V, 60 Hz or 220 V, 50 Hz
Filter TechnologyAerocell™ Multi-Stage Filtration System
Pre-Filter Efficiency91% for 1–3 µm particles
Optional Safety FiltersActivated Carbon, HEPA, or ULPA
Airflow MonitoringContinuous Low-Airflow Alarm with Visual Indicator
LightingEnergy-Efficient LED
Work Surface OptionsStainless Steel or Polypropylene (White/Black)
Mobility OptionLocking Casters (Optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDevea
OriginFrance
ModelPhileas® 285
Sterilization Volume Capacity50–1665 m³
Hydrogen Peroxide Dose Capacity20 L (2 × 10 L tanks)
Air Flow Rate4.2 L/h
Power Consumption120 W
Dimensions (L×W×H)839 × 450 × 813 mm
Weight25 kg
ConstructionFull Stainless Steel (AISI 316L-compatible surfaces)
Regulatory ComplianceEN 17272:2020, MA No. FR-2019-0071 (validated biocidal efficacy for HPV/machine combination)
CompatibilityO₂SAFE 7.4 & Phileasafe® bioindicator systems
Safety FeaturesLiquid inlet fault detection, automatic cycle termination on tank depletion
Max. Consecutive Cycles5
Droplet Size Distribution5–10 µm
Typical Cycle Time for 400 m³68 min @ 12 mL/m³ dosage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErreDue
OriginItaly
ModelGEMINI T6
Oxygen Purity90–95%
Oxygen Flow Rate5.25–7.5 NL/min
Output Pressure0.1–10 bar
Operating Temperature4–40 °C
Dimensions (W×H×D)370 × 710 × 590 mm
Power Supply110–120 V / 60 Hz or 220–240 V / 50 Hz
InterfaceEthernet & RS-485
Display3.5-inch touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCELLINK
OriginSweden
ModelBIO MDX
Maximum Microplate Capacity27 standard microplates or 140 microscope slides
Droplet Volume Resolution (with sciDROP PICO)<200 pL
Nozzle Temperature Range0–350 °C
Build Platform Temperature Range−10–80 °C
Ambient ControlHEPA-filtered laminar airflow, programmable humidity, temperature, and dew point
Positioning Accuracy≤1 µm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCELLINK
OriginSweden
ModelBIONOVA X
XY Resolution10 µm
Z-Axis Precision (Motor-Driven)4 µm
LED Wavelength405 nm (FWHM ±7.5 nm)
Light Intensity Range4–16 mW/cm²
Heater Temperature RangeAmbient to 60 °C
Compatible Well Plate Formats24-well, 12-well, and 6-well plates
Build Volume (per well)24-well: 63.6 mm² × 6.5 mm (X×Y×Z)
12-well9.0 × 9.0 × 9.0 mm
6-well19.2 × 10.8 × 9.0 mm
Connectivity1× USB-A port
Supported File Formats.stl, .png, .bmp, .jpg
Dimensions515 × 380 × 441 mm (W×D×H)
Weight41 kg
Power Input100–240 VAC, 50–60 Hz, 200 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDevea
OriginFrance
ModelPhileas®25
Sterilization Volume1–40 m³
Hydrogen Peroxide Dose500 mL
Air Flow Rate700 mL/h
Droplet Size5–10 µm
Cycle Duration (for 20 m³)20 min @ 12 mL/m³
Power Consumption30 W
Dimensions (L×W×H)475 × 193 × 222 mm
Weight5 kg
ComplianceEN 17272, MA FR-2019-0071
Power Input100–240 VAC, 50/60 Hz, 1.8 A
Material CompatibilityO₂SAFE 7.4 & Phileasafe® compatible