- All
- Favorite
- Popular
- Most rated
| Brand | ATLANTEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 400 |
| Pricing | Available Upon Request |
| Printing Method | Direct Thermal Printing |
| Print Resolution | 300 dpi |
| Print Width | 53 mm |
| Sample Width Capacity | 100 mm |
| Print Head Technology | Thin-Film Resistive (Corner-Type) |
| Print Speed Options | 10 in/s (programmable at three discrete settings) |
| Adjustable Parameters | Print Head Pressure, Print Head Position |
| Interface | RS-232 Serial |
| Power Supply | 115 V / 60 Hz or 220 V / 50 Hz |
| Test Patterns | Checkerboard, Solid Fill, UPC-A Barcode, User-Defined Patterns |
| Test Modes | Dynamic Reaction Sequence (10 energy steps), Full-sequence or single-step execution, repeat counts per step: 1×, 5×, or 10× |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1100E / HD-1100K |
| Measurement Range | E-type: −200 to +800°C |
| K-type | −200 to +1370°C |
| Accuracy | ±(0.05% of reading + 0.2°C) at 0°C (0.1°C resolution range) |
| Resolution | 0.1°C (−104.9 to +504.9°C for both E & K), otherwise 1°C |
| Waterproof Rating | IPX5 |
| Display | Large LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Data Logging | Up to 9999 records, 9 programmable intervals, manual trigger, playback & PC transfer via AMS-100 software |
| Compliance | CE, RoHS |
| Operating Environment | 0–40°C, 0–80% RH (non-condensing) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (incl. batteries) |
| Input | Single-channel thermocouple (E or K type), integrated cold-junction compensation, max input resistance 500 Ω |
| Sampling Rate | ~300 ms |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AR-6500H / AR-6501H |
| Measurement Principle | Radiation-based (Infrared) + Contact (Thermocouple) |
| Measurement Modes | Non-contact IR + K-type thermocouple contact |
| Temperature Range (IR) | –50.0 to 500.0 °C (AR-6500H), 0 to 1200 °C (AR-6501H) |
| Temperature Range (Contact) | –50.0 to 500.0 °C (K-type, ≤500 Ω) |
| Resolution | 0.1 °C (–50.0 to 525.0 °C display range), 1 °C (up to 1250 °C) |
| Accuracy (IR, AR-6500H) | ±3 °C (<0 °C), ±2 °C (0–250 °C), ±0.8% of reading +1 digit (250–500 °C) |
| Accuracy (Contact, K-type) | ±(0.05% of reading + 0.1 °C) ±1 digit |
| Emissivity Adjustment Range | 0.10–2.00 (0.01 step) |
| Spectral Response | 8–14 µm |
| Detector | Thermopile |
| Response Time | ≈300 ms |
| Laser Targeting | Integrated Class II red laser (650 nm) |
| Repeatability | ±0.4% of reading +1 digit |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| Temperature Coefficient | ±0.01% / °C of measured range |
| Analog Output | –1 mV/°C (optional, sensor sold separately) |
| Output Accuracy | ±(0.15% FS + 1 mV) at 25 °C ±5 °C |
| Power | Rechargeable Ni-Cd battery |
| Operating Time | >30 hours per full charge (varies with usage) |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage Environment | –20–50 °C, 0–85% RH (non-condensing) |
| Dimensions | As per manufacturer’s mechanical drawing |
| Weight | Approx. 400 g |
| Compliance | IEC 60584-1:2013 (K-type linearization), CE marking, RoHS compliant |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1350E / HD-1350K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Resolution | 1 °C or 0.1 °C (auto-switching) |
| Accuracy (0.1 °C mode) | ±(0.05% of reading + 0.2 °C) from 0 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C ±10 °C |
| Sampling Rate | ~300 ms |
| Input | Single-channel thermocouple (E or K standard |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) or optional AC adapter |
| IP Rating | Waterproof housing (IEC 60529 IP54 equivalent) |
| Compliance | CE, RoHS |
| Dimensions | 76 × 167 × 36 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1250E / HD-1250K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Accuracy (0 °C, 0.1 °C resolution) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0 °C, 1 °C resolution) | ±(0.1% of reading + 1 °C) |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C |
| Temperature Coefficient | ±0.01% F.S./°C |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Dimensions | 76 × 167 × 36 mm (W × H × D) |
| Weight | ~350 g (incl. batteries) |
| Compliance | CE, RoHS |
| Input | Single-channel thermocouple (E or K type), ANP connector |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Sampling Rate | ~300 ms |
| Data Logging | Up to 9999 records, programmable interval (9 options), manual trigger, peak/valley hold, playback, PC transfer via AMS-100 software |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1150E / HD-1150K |
| Temperature Range (E-type) | −200 to +800 °C |
| Temperature Range (K-type) | −200 to +1370 °C |
| Resolution | 0.1 °C (−104.9 to +504.9 °C), 1 °C elsewhere |
| Accuracy (0.1 °C range, ≥0 °C) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0.1 °C range, <0 °C) | ±0.5 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Battery Life | Up to 300 hours (4 × AA alkaline) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (including batteries) |
| Compliance | CE, RoHS, IEC 60584-1:2013 |
| Brand | ACL Staticide |
|---|---|
| Origin | USA |
| Model | 350 |
| Display | 3.5-digit LCD with polarity indication |
| Battery | 9 V alkaline (included) |
| Measurement Ranges | 1″ (0–20 kV, 100 V resolution) |
| Accuracy | ±10% of reading |
| Operating Temperature | 10–40 °C |
| Humidity Range | ≤80% RH non-condensing |
| Dimensions | 107 mm × 61 mm × 23 mm |
| Weight | 5 oz (142 g) |
| Calibration | NIST-traceable certificate included |
| Warranty | 1 year (voided if case opened) |
| Housing | Conductive antistatic polymer with built-in grounding path |
| Sample Distance Dependency | Explicitly defined per probe-to-surface spacing |
| Compliance | Meets ANSI/ESD S20.20 and IEC 61340-5-1 recommended practices for electrostatic field measurement |
| Brand | ACL Staticide |
|---|---|
| Origin | USA |
| Model | 780/781 |
| Test Range | 10⁵ – 10⁸ Ω (standard) |
| Accuracy | ±10% |
| Power Supply | 9 V DC battery or AC adapter |
| Operating Environment | 0–38 °C, 15–95% RH |
| Compliance | ESD Association ANSI/ESD S20.20 & STM97.1 |
| Display | Dual-color LED (red/green) with audible tone |
| Test Modes | Simultaneous wrist strap + bilateral footwear |
| Auto-ranging | Yes |
| Certifications | Factory calibration certificate included |
| Brand | ACL Staticide |
|---|---|
| Origin | USA |
| Model | ACL-800 |
| Impedance Range | 10³–10¹² Ω/□ (Surface) / 10³–10¹² Ω (Resistance) |
| Voltage Test Options | 10 V / 100 V |
| Relative Humidity Range | 10–90 %RH |
| Temperature Range | 0–37.8 °C (32–100 °F) |
| Electrodes Included | Two 2.5″ 5-lb RTT/RTG circular electrodes |
| Display | LCD digital |
| Power | 9 V alkaline battery |
| Compliance | ASTM F150, EOS/ESD S4.1, S7.1, S11.11, CECC 000500, UL 817 |
| Weight | 425 g |
| Enclosure | Protective molded plastic case |
| Brand | KURASHIKI |
|---|---|
| Origin | Japan |
| Model | EST-58-450 |
| Type | 6-DOF Active Vibration Isolation Platform |
| Compliance | Cleanroom-Compatible (ISO Class 5–7), No Compressed Air Required |
| Control Interface | USB 2.0 |
| Display | Integrated LCD for Real-Time Acceleration Time-Waveform & FFT Spectrum |
| Leveling Mode | Motorized Auto-Leveling with Transport Lock Toggle |
| Construction | Sealed Anodized Aluminum Enclosure & Top Plate |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AP-400 / AP-450 |
| Input Channels | 1 (Thermocouple) |
| Thermocouple Types Supported | AP-400 — E or K only |
| Measurement Range | E: −200 to +800 °C |
| K | −200 to +1370 °C |
| J | −200 to +1100 °C |
| T | −200 to +400 °C |
| R | 0 to +1760 °C |
| Resolution | 0.1 °C (within specified ranges), auto-switches to 1 °C outside |
| Accuracy | ±(0.05% of reading + 0.2 °C) for E/K/J/T at 0–100 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 ±10 °C |
| Temp. Coefficient | ±0.01% of range per °C outside 25 ±10 °C |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage | −20 to +50 °C, 0–85% RH (non-condensing) |
| Sampling Rate | 2 Hz (no print), down to 1 sample/min (interval modes) |
| Battery Life | Up to 120 hours (1-min interval, no print) |
| Power | 4 × AA alkaline batteries (included) or optional AC adapter (AD-100/115/220-500-HR-R) |
| Display | LCD |
| Printer | Thermal line printer, 2.5 mm character height, 37 mm paper width, 1000 lines per roll |
| Memory Capacity | 100 data records |
| Data Output | Absolute timestamp (HH:MM:SS), sequential numbering, batch print |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Dimensions | ~68 × 201 × 42 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Backup Power | Rechargeable lithium cell (real-time clock only) |
| Accessories Included | Carrying pouch, 4 × AA alkaline batteries, paper holder, user manual, ACAP4 thermal paper (1 roll), calibration report, registration card |
| Brand | KURASHIKI |
|---|---|
| Origin | Japan |
| Model | MINI560F |
| Type | 6-DOF Active Vibration Isolation Platform |
| Design | Compact Desktop Form Factor |
| Compliance | Cleanroom-Compatible (Sealed Aluminum Enclosure, No Compressed Air Required) |
| Control Interface | USB Communication with Real-Time Acceleration Time-Waveform & FFT Spectrum Display |
| Operation Modes | Auto-Leveling Mode / Transport Lock Mode |
| Typical Applications | Atomic Force Microscopy (AFM), Scanning Probe Microscopy (SPM), Laser Confocal Microscopy, Microhardness Testers, Interferometers |
| Brand | ChemInstruments |
|---|---|
| Origin | USA |
| Model | BP-2000 |
| Load Cell Capacity | 25 lbf (standard), optional 2, 5, 10, and 50 lbf |
| Force Resolution | 0.1% of full scale |
| Maximum Test Force | 50 lbf (222.4 N) |
| Test Speed Range | 0.5–25 IPM (1–64 CPM), adjustable in 0.5 IPM increments |
| Data Acquisition Rate | 1,000–5,000 points/second |
| Test Length Range | 0.25–1.5 in (0.5–3.5 cm), adjustable in 0.25 in (0.5 cm) increments |
| Operating Temperature | 0–70 °C (32–150 °F) |
| Power Input | 85–265 VAC, 50/60 Hz |
| Dimensions (H×W×D) | 63 × 46 × 25 cm |
| Weight | 20 kg |
| Display | 5.7-inch integrated touchscreen interface |
| Data Export | USB to EZ Data software |
| Compliance | Designed for TLMI-1G and PSTC test methods |
| Load Cell Options | 2, 5, 10, 25, and 50 lbf capacities available |
| Brand | James Heal |
|---|---|
| Origin | USA |
| Model | Gyrowash |
| Capacity | 8 or 20 test cups (selectable small/large cup configuration) |
| Standards Compliance | AATCC 61, 86, 132 |
| Temperature Control | Programmable digital controller |
| Sealing System | Chemically resistant PTFE-encapsulated elastomer O-rings |
| Cup Loading Mechanism | Push-and-rotate rotor interface |
| Accessories Compatibility | Multifiber fabric, single-fiber adjacent fabrics, AATCC/ECE detergents, stainless steel balls/balls, PTFE rods, grey scales for staining and color change assessment |
| Brand | Tablestable |
|---|---|
| Origin | Switzerland |
| Model | AVI-200 |
| Vibration Isolation Range | Active: 1–200 Hz |
| Passive | >200 Hz |
| Transmission Loss | < –35 dB above 10 Hz |
| Module Dimensions (W×D×H) | 130 × 600 × 110 mm (AVI-200 M) |
| Module Mass | 20 kg |
| Vertical Compliance | ~1.75 µm/N |
| Horizontal Compliance | ~3.5 µm/N |
| System Noise Floor | < 50 nG/√Hz |
| Power Consumption | 9 W typical |
| Input Voltage | 90–125 VAC / 200–250 VAC, 50–60 Hz |
| Controller Dimensions | 48 × 13 × 25 cm |
| Performance Monitoring | Multiplexed analog output for oscilloscope-based real-time vibration assessment |
Show next