Empowering Scientific Discovery

Shanghai Pinche Precision Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnritsu Meter
OriginJapan
ModelHD-1100E / HD-1100K
Measurement RangeE-type: −200 to +800°C
K-type−200 to +1370°C
Accuracy±(0.05% of reading + 0.2°C) at 0°C (0.1°C resolution range)
Resolution0.1°C (−104.9 to +504.9°C for both E & K), otherwise 1°C
Waterproof RatingIPX5
DisplayLarge LCD
Power4 × AA alkaline batteries (300 h typical life)
Data LoggingUp to 9999 records, 9 programmable intervals, manual trigger, playback & PC transfer via AMS-100 software
ComplianceCE, RoHS
Operating Environment0–40°C, 0–80% RH (non-condensing)
Dimensions76 × 167 × 36 mm (W×H×D)
Weight~350 g (incl. batteries)
InputSingle-channel thermocouple (E or K type), integrated cold-junction compensation, max input resistance 500 Ω
Sampling Rate~300 ms
LinearizationDigital, compliant with IEC 60584-1:2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnritsu Meter
OriginJapan
ModelAR-6500H / AR-6501H
Measurement PrincipleRadiation-based (Infrared) + Contact (Thermocouple)
Measurement ModesNon-contact IR + K-type thermocouple contact
Temperature Range (IR)–50.0 to 500.0 °C (AR-6500H), 0 to 1200 °C (AR-6501H)
Temperature Range (Contact)–50.0 to 500.0 °C (K-type, ≤500 Ω)
Resolution0.1 °C (–50.0 to 525.0 °C display range), 1 °C (up to 1250 °C)
Accuracy (IR, AR-6500H)±3 °C (<0 °C), ±2 °C (0–250 °C), ±0.8% of reading +1 digit (250–500 °C)
Accuracy (Contact, K-type)±(0.05% of reading + 0.1 °C) ±1 digit
Emissivity Adjustment Range0.10–2.00 (0.01 step)
Spectral Response8–14 µm
DetectorThermopile
Response Time≈300 ms
Laser TargetingIntegrated Class II red laser (650 nm)
Repeatability±0.4% of reading +1 digit
Reference Junction Compensation Accuracy±0.2 °C (at 25 °C ±10 °C)
Temperature Coefficient±0.01% / °C of measured range
Analog Output–1 mV/°C (optional, sensor sold separately)
Output Accuracy±(0.15% FS + 1 mV) at 25 °C ±5 °C
PowerRechargeable Ni-Cd battery
Operating Time>30 hours per full charge (varies with usage)
Operating Environment0–40 °C, 0–80% RH (non-condensing)
Storage Environment–20–50 °C, 0–85% RH (non-condensing)
DimensionsAs per manufacturer’s mechanical drawing
WeightApprox. 400 g
ComplianceIEC 60584-1:2013 (K-type linearization), CE marking, RoHS compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnritsu Meter
OriginJapan
ModelHD-1350E / HD-1350K
Temperature Range (E-type)−200 to 800 °C
Temperature Range (K-type)−200 to 1370 °C
Resolution1 °C or 0.1 °C (auto-switching)
Accuracy (0.1 °C mode)±(0.05% of reading + 0.2 °C) from 0 °C
Reference Junction Compensation Accuracy±0.2 °C at 25 °C ±10 °C
Sampling Rate~300 ms
InputSingle-channel thermocouple (E or K standard
DisplayBacklit LCD
Power4 × AA alkaline batteries (300 h typical life) or optional AC adapter
IP RatingWaterproof housing (IEC 60529 IP54 equivalent)
ComplianceCE, RoHS
Dimensions76 × 167 × 36 mm (W×H×D, excl. protrusions)
Weight~350 g (incl. batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnritsu Meter
OriginJapan
ModelHD-1250E / HD-1250K
Temperature Range (E-type)−200 to 800 °C
Temperature Range (K-type)−200 to 1370 °C
Accuracy (0 °C, 0.1 °C resolution)±(0.05% of reading + 0.2 °C)
Accuracy (0 °C, 1 °C resolution)±(0.1% of reading + 1 °C)
Reference Junction Compensation Accuracy±0.2 °C at 25 °C
Temperature Coefficient±0.01% F.S./°C
IP RatingIPX5
DisplayBacklit LCD
Power4 × AA alkaline batteries (300 h typical life)
Dimensions76 × 167 × 36 mm (W × H × D)
Weight~350 g (incl. batteries)
ComplianceCE, RoHS
InputSingle-channel thermocouple (E or K type), ANP connector
LinearizationDigital, compliant with IEC 60584-1:2013
Sampling Rate~300 ms
Data LoggingUp to 9999 records, programmable interval (9 options), manual trigger, peak/valley hold, playback, PC transfer via AMS-100 software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnritsu Meter
OriginJapan
ModelHD-1150E / HD-1150K
Temperature Range (E-type)−200 to +800 °C
Temperature Range (K-type)−200 to +1370 °C
Resolution0.1 °C (−104.9 to +504.9 °C), 1 °C elsewhere
Accuracy (0.1 °C range, ≥0 °C)±(0.05% of reading + 0.2 °C)
Accuracy (0.1 °C range, <0 °C)±0.5 °C
Reference Junction Compensation Accuracy±0.2 °C (at 25 °C ±10 °C)
IP RatingIPX5
DisplayBacklit LCD
Battery LifeUp to 300 hours (4 × AA alkaline)
Dimensions76 × 167 × 36 mm (W×H×D)
Weight~350 g (including batteries)
ComplianceCE, RoHS, IEC 60584-1:2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnritsu Meter
OriginJapan
ModelAP-400 / AP-450
Input Channels1 (Thermocouple)
Thermocouple Types SupportedAP-400 — E or K only
Measurement RangeE: −200 to +800 °C
K−200 to +1370 °C
J−200 to +1100 °C
T−200 to +400 °C
R0 to +1760 °C
Resolution0.1 °C (within specified ranges), auto-switches to 1 °C outside
Accuracy±(0.05% of reading + 0.2 °C) for E/K/J/T at 0–100 °C
Reference Junction Compensation Accuracy±0.2 °C at 25 ±10 °C
Temp. Coefficient±0.01% of range per °C outside 25 ±10 °C
Operating Environment0–40 °C, 0–80% RH (non-condensing)
Storage−20 to +50 °C, 0–85% RH (non-condensing)
Sampling Rate2 Hz (no print), down to 1 sample/min (interval modes)
Battery LifeUp to 120 hours (1-min interval, no print)
Power4 × AA alkaline batteries (included) or optional AC adapter (AD-100/115/220-500-HR-R)
DisplayLCD
PrinterThermal line printer, 2.5 mm character height, 37 mm paper width, 1000 lines per roll
Memory Capacity100 data records
Data OutputAbsolute timestamp (HH:MM:SS), sequential numbering, batch print
LinearizationDigital, compliant with IEC 60584-1:2013
Dimensions~68 × 201 × 42 mm (W×H×D, excl. protrusions)
Weight~350 g (incl. batteries)
Backup PowerRechargeable lithium cell (real-time clock only)
Accessories IncludedCarrying pouch, 4 × AA alkaline batteries, paper holder, user manual, ACAP4 thermal paper (1 roll), calibration report, registration card