- All
- Favorite
- Popular
- Most rated
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-UM4800 |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Compatible Systems | HPLC (all major brands) |
| Detector Type | Evaporative Light-Scattering Detector (ELSD) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PCD-3000 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–9.999 mL/min |
| Reaction Coil Material | Chemically Inert (e.g., PEEK, Hastelloy, or fused silica) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EasySep®-3030FLD |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 200–800 nm |
| Light Source | Xenon Lamp |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Easysep-1020 |
| Price Range | USD 2,800 – 7,000 (FOB Shanghai) |
| Pump Type | Binary Gradient Pump |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | UM5800Plus |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Light Source | Solid-State Laser |
| Detection Principle | Light Scattering of Nebulized and Dried Analyte Particles |
| Wavelength | Fixed-Wavelength Laser (Typical 650 nm) |
| Signal Output | Dual-Mode — Digital (USB/RS-232) and Analog (±2.4 V DC) |
| Gain Adjustment | 7-Step Programmable Gain Control |
| Method Storage Capacity | 100 Predefined Methods |
| Display | Integrated High-Resolution TFT Screen with Real-Time Chromatogram Rendering |
| Control Architecture | Fully Software-Reverse-Controlled (Temperature, Nebulizer Gas Flow, Gain, Detection Threshold) |
| Compliance | GLP-Ready with Audit Trail Logging, Password-Protected Access, Error Log Archiving |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UM5000 |
| Price Range | USD 7,000 – 14,000 (FOB Shanghai) |
| Compatible Instrument | High-Performance Liquid Chromatography (HPLC) Systems |
| Detector Type | Evaporative Light-Scattering Detector (ELSD) |
| Light Source | Laser Diode |
| Wavelength | 650 nm |
| Detection Principle | Light Scattering of Nebulized and Evaporated Analyte Particles |
| Operating Mode | Beam Transmission Method |
| Evaporation Temperature Range | Up to 130 °C (adjustable, low-temperature optimized) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | TriSep-2100 |
| Compatible Instrument | HPLC Systems |
| Detector Type | Laser-Induced Fluorescence (LIF) Detector |
| Excitation Wavelength | 488 nm |
| Optical Configuration | Dual-Beam Design |
| Light Source | Solid-State Semiconductor Laser |
| Detection Limit | 1 × 10⁻¹¹ mol/L |
| Photomultiplier Tube (PMT) | High-Sensitivity, Wide Dynamic Range, Single-Photon Counting Capable |
| Optical Path Design | Patented Modular Flow Cell with Precision Window Positioning Mechanism |
| Software | Integrated Data Acquisition and Quantitative Analysis Suite Supporting Baseline Correction, Peak Integration, Calibration Curve Fitting, and Audit-Trail Logging |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DAD-2000 |
| Instrument Type | Diode Array Detector (DAD) |
| Wavelength Range | 200–800 nm |
| Detection Method | Simultaneous Multi-Wavelength Photodiode Array |
| Light Source | Deuterium Lamp + Tungsten Lamp |
| Output Interfaces | Digital (USB/Ethernet) and Analog (0–1 V, 0–5 V, 0–10 V) |
| Compatible Systems | HPLC, UHPLC, and Modular LC Platforms |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Bischoff GmbH |
| Model | RI-8120 (Analytical), RI-8120P (Preparative) |
| Detection Principle | Differential Refractive Index |
| Wavelength | 950 nm LED |
| Optical Sensor | Silicon Photodiode |
| Temperature Control | Integrated Heat Exchanger System |
| Compatibility | HPLC & Prep-LC Systems |
| Compliance | Designed for GLP/GMP environments with stable baseline performance per ISO 17025-relevant operational principles |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | AS1020 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | 120 × 1.8 mL vials (2 × 60-position racks) |
| Injection Modes | Full-loop, Partial-loop, and Needle-Over-Loop (NOL) / Zero-dead-volume injection |
| Minimum Injection Volume | 0.1 µL (with 250 µL syringe pump) |
| Syringe Pump Volume | 250 µL (standard) |
| Loop Volume | 100 µL (standard) |
| Injection Valve Switching Time | <100 ms |
| Positioning Accuracy | <0.3 mm |
| Motion Architecture | XYZ three-axis Cartesian coordinate system |
| Needle Wash | Dual internal/external wash with programmable unlimited rinse cycles |
| Carryover | <0.01% |
| Precision (RSD) | <0.5% |
| Linearity (r²) | >0.999 |
| Dimensions (W×D×H) | 300 × 505 × 230 mm |
| Power Supply | AC 220 V, 50 Hz |
| Operating Temperature Range | 10–40 °C |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | URI-3000 RID |
| Detection Principle | Differential Refractive Index (dRI) |
| Wavelength Range | 0.25–512 µRIU |
| Light Source | Tungsten Halogen Lamp |
| Compatible Systems | HPLC (Universal Analog Output + Optional Digital Interface) |
| Compliance | Designed for GLP/GMP-aligned QC environments |
| Software Integration | Unimicro ChromaControl™ (Optional) |
| Brand | Shodex |
|---|---|
| Origin | Japan |
| Model | RI-201H |
| Detection Principle | Differential Refractive Index (dRI) |
| Compatible Systems | HPLC & GPC Platforms |
| Detector Type | Universal Bulk Property Detector |
| Temperature Control | Built-in Thermostatic Cell Housing |
| Output Signal | Analog Voltage (0–1 V) & Digital RS-232 Interface |
| Noise Level | ≤ 2.5 × 10⁻⁹ RIU (RMS, 1 sec time constant) |
| Drift | ≤ 2 × 10⁻⁷ RIU/h (at 40 °C, stabilized) |
| Flow Cell Volume | 8 µL |
| Maximum Flow Rate | 10 mL/min |
| Solvent Compatibility | All HPLC-grade solvents except strong halogenated organics (e.g., chloroform, carbon tetrachloride) |
| Compliance | CE Marked, RoHS Compliant, Designed per IEC 61010-1 for Laboratory Equipment Safety |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PD-1000 |
| Temperature Range | Ambient |
| Derivatization Reagent Flow Rate | 3 mL/min |
| Reaction Tubing Material | Inert (e.g., PFA or FEP) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | UM5800 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Principle | Evaporative Light Scattering |
| Light Source | Semiconductor Laser |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 460 × 330 × 220 mm |
| Operating Temperature | 15–40 °C |
| Relative Humidity | <90% RH |
| Evaporation Temperature Range | Ambient to 130 °C |
| Temp. Increment | 1 °C |
| Temp. Accuracy | ±1 °C |
| Carrier Gas | Nitrogen or Compressed Air |
| Gas Input Pressure | 2–5 bar |
| Pressure Sensing Accuracy | 0.01 bar |
| Gas Flow Rate | 1–4 L/min |
| Flow Accuracy | ≤1% or ±0.02 L/min |
| Liquid Flow Compatibility | 10 μL/min – 3 mL/min |
| Baseline Noise | <0.03 mV |
| Baseline Drift | <0.3 mV/h |
| Limit of Detection (LOD) | <1 ng (on-column, glucose) |
| Typical Quantitative Range | 0.1–30 μg (glucose) |
| Precision (RSD₆) | <2% (glucose) |
| Signal Output | 0–1 V DC |
| Interface | RS-232 |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | UV-Vis Absorbance Detector |
| Model | Trisep®-2100 |
| Light Sources | Deuterium Lamp & Tungsten-Halogen Lamp |
| Wavelength Range | 190–600 nm |
| Spectral Bandwidth | 8 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Drift | ≤5 × 10⁻⁴ AU/h |
| Baseline Noise | ≤6 × 10⁻⁶ AU (RMS, 1 s time constant) |
| Absorbance Range | 0.0001–2.56 AU Full Scale (AUFS) |
| D₂ Lamp Lifetime | ≥2000 h |
| Operating Temperature | 4–35 °C |
| Dimensions (W×H×D) | 260 × 140 × 430 mm |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Easysep-1050 |
| Instrument Type | Binary Pump |
| Flow Mode | Dual-Piston Reciprocating in Series |
| Flow Rate Range | 0.001–9.999 mL/min |
| Flow Resolution | 0.001 mL/min |
| Max Operating Pressure | 42 MPa (pressure upper/lower limit programmable with auto-alarm) |
| Flow Accuracy | ≤ ±0.3% |
| Flow Precision | ≤ 0.075% RSD |
| Pressure Pulsation | ≤ 0.1 MPa |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | UNIEX-7700 |
| Compatible Instrument | Liquid Chromatography (LC) Systems |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Dual-Beam |
| Light Source | Semiconductor Laser Diode |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Instrument Type | Evaporative Light-Scattering Detector (ELSD) |
| Model | UM5000A |
| Detection Principle | Nebulization–evaporation–light scattering |
| Light Source | 650 nm semiconductor laser diode |
| Detector | Photomultiplier tube (PMT) |
| Evaporation Zone Temperature Range | Ambient to 130 °C (±1 °C control accuracy) |
| Nebulizing Gas | Nitrogen or compressed air (2–5 bar, ±0.01 bar pressure accuracy |
| Solvent Flow Rate Compatibility | 10 µL/min – 3 mL/min |
| Detection Limit | <1 ng (glucose, direct injection) |
| Baseline Noise | <0.05 mV (at 1 mL/min) |
| Baseline Drift | <0.5 mV (at 1 mL/min) |
| Quantitative Range | 0.1–30 µg (glucose, HPLC) |
| Quantitative Repeatability | RSD₆ < 2% (glucose, 1 mL/min) |
| Signal Output | 0–10 mV DC or 0–1 V DC |
| Interface | RS232 |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software logging |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Model | UM4800 |
| Evaporation Zone Temperature Range | Ambient to 130 °C |
| Nebulizing Gas | Nitrogen or Compressed Air |
| Gas Flow Rate | 1–4 L/min |
| Baseline Drift | <1.0 mV/h (under specified conditions: 1 mL/min flow, 10% methanol mobile phase, 40 °C evaporation temperature, 3 L/min gas flow) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Compatible System | Liquid Chromatography (HPLC/UHPLC) |
| Light Source | Laser Diode |
| Detection Principle | Laser-based light scattering after nebulization and solvent evaporation |
| Wavelength | Fixed laser wavelength (typical 635–650 nm) |
| Noise Level | < 0.01 mV |
| Baseline Drift | < 0.1 mV |
| Detection Limit (LOD) | < 1 × 10⁻⁷ g on-column (for typical non-volatile analytes) |
| Signal Gain | Multi-step adjustable (6–8 discrete gain levels) |
| Temperature Control | Dual-zone heated drift tube (ambient to 120 °C, ±0.5 °C stability) |
| Operating Modes | High-Temp Mode & Low-Temp Mode (user-selectable) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UM 5800 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 460 × 330 × 220 mm |
| Operating Environment | 15–40 °C, RH < 90% |
| Nebulizer Gas | Nitrogen or compressed air |
| Gas Pressure Range | 2–5 bar |
| Gas Flow Rate | 1–4 L/min |
| Gas Flow Accuracy | ≤1% or ±0.02 L/min |
| Gas Pressure Detection Resolution | 0.01 bar |
| Evaporation Temperature Range | Ambient to 130 °C |
| Temperature Increment | 1 °C |
| Temperature Control Accuracy | ±1 °C |
| Liquid Flow Rate Compatibility | 10 μL/min – 3 mL/min |
| Baseline Noise | <0.03 mV |
| Baseline Drift | <0.03 mV/h |
| Minimum Detectable Mass | <1 ng |
| Typical Quantitative Range | 0.1 μg – 30 μg |
| Quantitative Reproducibility (RSD₆) | <2% |
| Light Source | 650 nm semiconductor laser |
| Detection Element | Photomultiplier tube (PMT) |
| Signal Output | 0–1 V DC |
| Interface | RS-232 |
| Alarm Functions | Real-time temperature, gas pressure, and flow rate monitoring |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TriSep®-3000LIF |
| Detection Principle | Laser-Induced Fluorescence (LIF) |
| Excitation Wavelengths | 375 nm, 488 nm, 532 nm, 638 nm (custom wavelengths available) |
| Detection Mode | Dual-Beam |
| Light Source | Semiconductor Laser Diode |
| Compatible Systems | Capillary Electrophoresis (CE), Capillary Electrochromatography (CEC), Microbore HPLC, Capillary LC, Microfluidic Chips, Conventional HPLC |
Show next