Empowering Scientific Discovery

Shanghai Tongwei Analytical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelELSD-UM4800
Price RangeUSD 7,000–14,000 (FOB Shanghai)
Compatible SystemsHPLC (all major brands)
Detector TypeEvaporative Light-Scattering Detector (ELSD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginDomestic (China)
ModelPCD-3000
Temperature RangeAmbient to 150 °C
Derivatization Reagent Flow Rate0.001–9.999 mL/min
Reaction Coil MaterialChemically Inert (e.g., PEEK, Hastelloy, or fused silica)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelEasySep®-3030FLD
Instrument TypeFluorescence Detector (FD)
Wavelength Range200–800 nm
Light SourceXenon Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelEasysep-1020
Price RangeUSD 2,800 – 7,000 (FOB Shanghai)
Pump TypeBinary Gradient Pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelUM5800Plus
Instrument TypeEvaporative Light Scattering Detector (ELSD)
Light SourceSolid-State Laser
Detection PrincipleLight Scattering of Nebulized and Dried Analyte Particles
WavelengthFixed-Wavelength Laser (Typical 650 nm)
Signal OutputDual-Mode — Digital (USB/RS-232) and Analog (±2.4 V DC)
Gain Adjustment7-Step Programmable Gain Control
Method Storage Capacity100 Predefined Methods
DisplayIntegrated High-Resolution TFT Screen with Real-Time Chromatogram Rendering
Control ArchitectureFully Software-Reverse-Controlled (Temperature, Nebulizer Gas Flow, Gain, Detection Threshold)
ComplianceGLP-Ready with Audit Trail Logging, Password-Protected Access, Error Log Archiving
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUM5000
Price RangeUSD 7,000 – 14,000 (FOB Shanghai)
Compatible InstrumentHigh-Performance Liquid Chromatography (HPLC) Systems
Detector TypeEvaporative Light-Scattering Detector (ELSD)
Light SourceLaser Diode
Wavelength650 nm
Detection PrincipleLight Scattering of Nebulized and Evaporated Analyte Particles
Operating ModeBeam Transmission Method
Evaporation Temperature RangeUp to 130 °C (adjustable, low-temperature optimized)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Product OriginDomestic (China)
ModelTriSep-2100
Compatible InstrumentHPLC Systems
Detector TypeLaser-Induced Fluorescence (LIF) Detector
Excitation Wavelength488 nm
Optical ConfigurationDual-Beam Design
Light SourceSolid-State Semiconductor Laser
Detection Limit1 × 10⁻¹¹ mol/L
Photomultiplier Tube (PMT)High-Sensitivity, Wide Dynamic Range, Single-Photon Counting Capable
Optical Path DesignPatented Modular Flow Cell with Precision Window Positioning Mechanism
SoftwareIntegrated Data Acquisition and Quantitative Analysis Suite Supporting Baseline Correction, Peak Integration, Calibration Curve Fitting, and Audit-Trail Logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginJiangsu, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelDAD-2000
Instrument TypeDiode Array Detector (DAD)
Wavelength Range200–800 nm
Detection MethodSimultaneous Multi-Wavelength Photodiode Array
Light SourceDeuterium Lamp + Tungsten Lamp
Output InterfacesDigital (USB/Ethernet) and Analog (0–1 V, 0–5 V, 0–10 V)
Compatible SystemsHPLC, UHPLC, and Modular LC Platforms
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginGermany
ManufacturerBischoff GmbH
ModelRI-8120 (Analytical), RI-8120P (Preparative)
Detection PrincipleDifferential Refractive Index
Wavelength950 nm LED
Optical SensorSilicon Photodiode
Temperature ControlIntegrated Heat Exchanger System
CompatibilityHPLC & Prep-LC Systems
ComplianceDesigned for GLP/GMP environments with stable baseline performance per ISO 17025-relevant operational principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelAS1020
Instrument TypeHPLC Autosampler
Sample Capacity120 × 1.8 mL vials (2 × 60-position racks)
Injection ModesFull-loop, Partial-loop, and Needle-Over-Loop (NOL) / Zero-dead-volume injection
Minimum Injection Volume0.1 µL (with 250 µL syringe pump)
Syringe Pump Volume250 µL (standard)
Loop Volume100 µL (standard)
Injection Valve Switching Time<100 ms
Positioning Accuracy<0.3 mm
Motion ArchitectureXYZ three-axis Cartesian coordinate system
Needle WashDual internal/external wash with programmable unlimited rinse cycles
Carryover<0.01%
Precision (RSD)<0.5%
Linearity (r²)>0.999
Dimensions (W×D×H)300 × 505 × 230 mm
Power SupplyAC 220 V, 50 Hz
Operating Temperature Range10–40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (PRC)
ModelURI-3000 RID
Detection PrincipleDifferential Refractive Index (dRI)
Wavelength Range0.25–512 µRIU
Light SourceTungsten Halogen Lamp
Compatible SystemsHPLC (Universal Analog Output + Optional Digital Interface)
ComplianceDesigned for GLP/GMP-aligned QC environments
Software IntegrationUnimicro ChromaControl™ (Optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShodex
OriginJapan
ModelRI-201H
Detection PrincipleDifferential Refractive Index (dRI)
Compatible SystemsHPLC & GPC Platforms
Detector TypeUniversal Bulk Property Detector
Temperature ControlBuilt-in Thermostatic Cell Housing
Output SignalAnalog Voltage (0–1 V) & Digital RS-232 Interface
Noise Level≤ 2.5 × 10⁻⁹ RIU (RMS, 1 sec time constant)
Drift≤ 2 × 10⁻⁷ RIU/h (at 40 °C, stabilized)
Flow Cell Volume8 µL
Maximum Flow Rate10 mL/min
Solvent CompatibilityAll HPLC-grade solvents except strong halogenated organics (e.g., chloroform, carbon tetrachloride)
ComplianceCE Marked, RoHS Compliant, Designed per IEC 61010-1 for Laboratory Equipment Safety
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelPD-1000
Temperature RangeAmbient
Derivatization Reagent Flow Rate3 mL/min
Reaction Tubing MaterialInert (e.g., PFA or FEP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelUM5800
Instrument TypeEvaporative Light Scattering Detector (ELSD)
Wavelength650 nm
Detection PrincipleEvaporative Light Scattering
Light SourceSemiconductor Laser
Power Supply220 V, 50 Hz
Dimensions (W×D×H)460 × 330 × 220 mm
Operating Temperature15–40 °C
Relative Humidity<90% RH
Evaporation Temperature RangeAmbient to 130 °C
Temp. Increment1 °C
Temp. Accuracy±1 °C
Carrier GasNitrogen or Compressed Air
Gas Input Pressure2–5 bar
Pressure Sensing Accuracy0.01 bar
Gas Flow Rate1–4 L/min
Flow Accuracy≤1% or ±0.02 L/min
Liquid Flow Compatibility10 μL/min – 3 mL/min
Baseline Noise<0.03 mV
Baseline Drift<0.3 mV/h
Limit of Detection (LOD)<1 ng (on-column, glucose)
Typical Quantitative Range0.1–30 μg (glucose)
Precision (RSD₆)<2% (glucose)
Signal Output0–1 V DC
InterfaceRS-232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeUV-Vis Absorbance Detector
ModelTrisep®-2100
Light SourcesDeuterium Lamp & Tungsten-Halogen Lamp
Wavelength Range190–600 nm
Spectral Bandwidth8 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.1 nm
Baseline Drift≤5 × 10⁻⁴ AU/h
Baseline Noise≤6 × 10⁻⁶ AU (RMS, 1 s time constant)
Absorbance Range0.0001–2.56 AU Full Scale (AUFS)
D₂ Lamp Lifetime≥2000 h
Operating Temperature4–35 °C
Dimensions (W×H×D)260 × 140 × 430 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Product CategoryDomestic
ModelEasysep-1050
Instrument TypeBinary Pump
Flow ModeDual-Piston Reciprocating in Series
Flow Rate Range0.001–9.999 mL/min
Flow Resolution0.001 mL/min
Max Operating Pressure42 MPa (pressure upper/lower limit programmable with auto-alarm)
Flow Accuracy≤ ±0.3%
Flow Precision≤ 0.075% RSD
Pressure Pulsation≤ 0.1 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelUNIEX-7700
Compatible InstrumentLiquid Chromatography (LC) Systems
Detector TypeEvaporative Light Scattering Detector (ELSD)
Wavelength650 nm
Detection ModeDual-Beam
Light SourceSemiconductor Laser Diode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
ManufacturerYes
Instrument TypeEvaporative Light-Scattering Detector (ELSD)
ModelUM5000A
Detection PrincipleNebulization–evaporation–light scattering
Light Source650 nm semiconductor laser diode
DetectorPhotomultiplier tube (PMT)
Evaporation Zone Temperature RangeAmbient to 130 °C (±1 °C control accuracy)
Nebulizing GasNitrogen or compressed air (2–5 bar, ±0.01 bar pressure accuracy
Solvent Flow Rate Compatibility10 µL/min – 3 mL/min
Detection Limit<1 ng (glucose, direct injection)
Baseline Noise<0.05 mV (at 1 mL/min)
Baseline Drift<0.5 mV (at 1 mL/min)
Quantitative Range0.1–30 µg (glucose, HPLC)
Quantitative RepeatabilityRSD₆ < 2% (glucose, 1 mL/min)
Signal Output0–10 mV DC or 0–1 V DC
InterfaceRS232
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeEvaporative Light Scattering Detector (ELSD)
ModelUM4800
Evaporation Zone Temperature RangeAmbient to 130 °C
Nebulizing GasNitrogen or Compressed Air
Gas Flow Rate1–4 L/min
Baseline Drift<1.0 mV/h (under specified conditions: 1 mL/min flow, 10% methanol mobile phase, 40 °C evaporation temperature, 3 L/min gas flow)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeEvaporative Light Scattering Detector (ELSD)
Compatible SystemLiquid Chromatography (HPLC/UHPLC)
Light SourceLaser Diode
Detection PrincipleLaser-based light scattering after nebulization and solvent evaporation
WavelengthFixed laser wavelength (typical 635–650 nm)
Noise Level< 0.01 mV
Baseline Drift< 0.1 mV
Detection Limit (LOD)< 1 × 10⁻⁷ g on-column (for typical non-volatile analytes)
Signal GainMulti-step adjustable (6–8 discrete gain levels)
Temperature ControlDual-zone heated drift tube (ambient to 120 °C, ±0.5 °C stability)
Operating ModesHigh-Temp Mode & Low-Temp Mode (user-selectable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUM 5800
Instrument TypeEvaporative Light Scattering Detector (ELSD)
Power Supply220 V, 50 Hz
Dimensions (L×W×H)460 × 330 × 220 mm
Operating Environment15–40 °C, RH < 90%
Nebulizer GasNitrogen or compressed air
Gas Pressure Range2–5 bar
Gas Flow Rate1–4 L/min
Gas Flow Accuracy≤1% or ±0.02 L/min
Gas Pressure Detection Resolution0.01 bar
Evaporation Temperature RangeAmbient to 130 °C
Temperature Increment1 °C
Temperature Control Accuracy±1 °C
Liquid Flow Rate Compatibility10 μL/min – 3 mL/min
Baseline Noise<0.03 mV
Baseline Drift<0.03 mV/h
Minimum Detectable Mass<1 ng
Typical Quantitative Range0.1 μg – 30 μg
Quantitative Reproducibility (RSD₆)<2%
Light Source650 nm semiconductor laser
Detection ElementPhotomultiplier tube (PMT)
Signal Output0–1 V DC
InterfaceRS-232
Alarm FunctionsReal-time temperature, gas pressure, and flow rate monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUnimicro Technologies
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelTriSep®-3000LIF
Detection PrincipleLaser-Induced Fluorescence (LIF)
Excitation Wavelengths375 nm, 488 nm, 532 nm, 638 nm (custom wavelengths available)
Detection ModeDual-Beam
Light SourceSemiconductor Laser Diode
Compatible SystemsCapillary Electrophoresis (CE), Capillary Electrochromatography (CEC), Microbore HPLC, Capillary LC, Microfluidic Chips, Conventional HPLC
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0