| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UNIEX-7700PLUS |
| Pricing | Upon Request |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EasySep®3050PLC |
| Instrument Category | Conventional HPLC System |
| Application Scope | General-Purpose Preparative Chromatography |
| Flow Rate Range | 0–50 mL/min |
| Maximum Pressure | 42 MPa |
| Flow Accuracy | < 0.06% RSD |
| Autosampler Capacity | 24 positions (10 mL vials) |
| Injection Volume Range | 0–10 mL |
| Column Oven Temperature Range | 5 °C above ambient to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | EasySep®-1050 |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0–50 mL/min |
| Pump Pressure Range | 0–35 MPa |
| Refractive Index Detector Drift | ≤2.5 nRIU |
| RI Detector Flow Cell Volume | 8 µL |
| UV Detector Wavelength Range | 190–700 nm |
| UV Detector Noise | ≤1.0 × 10⁻⁵ AU |
| Column Oven Temperature Range | Ambient to 100 °C |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AutoCE-3000 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Application | Organic Analysis |
| Voltage Range | 0 to ±30 kV (adjustable) |
| Cooling Method | Liquid-based Cooling |
| Sample Temperature Control | Water-cooled Thermostatic Module |
| Detector | UV-Vis Photodiode Array Detector (190–600 nm, adjustable wavelength) |
| Operation Modes | Constant Voltage, Constant Current, or Constant Power |
| Injection Mode | Electrokinetic Injection |
| Pressure Range | 0–95 psi |
| Thermal Management System | Closed-loop Liquid Cooling Circuit |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EasySep-3220/3248 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium- to Low-Pressure Preparative LC System |
| Flow Rate Range | 0.1–200 mL/min |
| Maximum Operating Pressure | 200 psi |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–120 °C/min |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Maximum Operating Temperature | 4 °C to 450 °C |
| Detection Options | FID, TCD, ECD, FPD, NPD (up to three detectors simultaneously) |
| Electronic Flow Control (EFC) & Electronic Pressure Control (EPC) | Standard |
| Data Acquisition | 24-bit low-noise ADC with baseline storage and subtraction capability |
| Communication Protocol | MODBUS/TCP compliant |
| User Interface | 7-inch full-color capacitive touchscreen (hot-swappable, handheld operation supported) |
| System Architecture | Multi-processor parallel control firmware |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | EasySep®-5010 |
| Instrument Type | Conventional UHPLC System |
| Application Scope | General-purpose analytical chromatography |
| Maximum Operating Pressure | 68 MPa |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | MMT-3000 |
| Pricing | Available Upon Request |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EasySep-1020 HPLC |
| Instrument Category | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | <0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV/Vis Wavelength Range | 190–600 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Yamazen |
|---|---|
| Origin | Japan |
| Model | W-Prep 2XY |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–80 mL/min |
| Flow Accuracy | RSD ≤ 1% (n = 6) |
| Flow Precision | RSD ≤ 1% (n = 6) |
| Maximum Operating Pressure | 1.0 MPa |
| Wavelength Range Options | 254 nm fixed / 190–380 nm / 190–600 nm |
| Wavelength Reproducibility | ≤ 0.1 nm |
| Baseline Noise | ≤ 1 × 10⁻⁵ AU |
| Data Acquisition Rate | 20 Hz |
| Brand | Yamazen |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor (Global) |
| Product Category | Imported Instrument |
| Model | AI-580S |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Low Pressure Preparative HPLC System |
| Flow Rate Range | 0–80 mL/min |
| Flow Accuracy | RSD ≤ 1% (n = 6) |
| Flow Precision | RSD ≤ 1% (n = 6) |
| Maximum Operating Pressure | 1.0 MPa |
| Wavelength Range (UV Detector Options) | 254 nm fixed, or 190–380 nm / 190–600 nm variable |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Baseline Noise | ≤ 1 × 10⁻⁵ AU |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Model | EasySep®-3050 |
| Flow Rate Range | 0–50 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | 0–5 mL |
| Column Oven Temperature Range | –100 °C (requires optional cryogenic module) |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 20 Hz |
| Detector Options | UV-Vis, Diode Array (DAD), Fluorescence (FLD), Evaporative Light Scattering (ELSD), Mass Spectrometry (MS) interfaces |
| Software Control | Unimicro ChromStation (full bidirectional control) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Model | EasySep-1010 |
| Pump Types | Analytical (10 mL stainless steel head) & Semi-Preparative (50 mL stainless steel head) |
| Flow Range (Analytical) | 0.01–9.99 mL/min |
| Max Pressure (Analytical, SS) | 42 MPa |
| Flow Range (Semi-Prep) | 0.1–49.9 mL/min |
| Max Pressure (Semi-Prep, SS) | 30 MPa |
| Flow Accuracy (Analytical) | RSD ≤ 0.5% at 1 mL/min |
| Flow Precision (Analytical) | RSD ≤ 0.1% at 1 mL/min |
| Flow Accuracy (Semi-Prep) | RSD ≤ 2% at 1 & 10 mL/min |
| Flow Precision (Semi-Prep) | RSD ≤ 0.5% at 1 & 10 mL/min |
| UV-VIS Detector | Wavelength Range 190–360 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Spectral Bandwidth | 8 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Light Source | DX2 Dual-Life Deuterium Lamp |
| Detector Cell Options | Analytical & Semi-Preparative Flow Cells |
| Display | 320×240 dot-matrix LCD |
| System Protection | Soft-start/stop, programmable pressure limits, auto data backup |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | EasySep®-3030 Binary/Quaternary HPLC System |
| Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | 0–100 µL |
| Column Oven Temperature Range | Ambient to 100 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Yamazen |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AI-700X |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Options | 150 mL/min, 200 mL/min, 350 mL/min, 400 mL/min |
| Flow Accuracy | RSD₆ ≤ 1% |
| Flow Precision | RSD₆ ≤ 1% |
| Maximum Operating Pressure | 1.5 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Frequency | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | EasySep®-3030 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 42 MPa |
| Sample Tray Capacity | 108 positions (2 mL vials) |
| Injection Volume Range | 0–100 µL |
| Column Oven Temperature Range | Ambient to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EasySep-1050 Semi-Preparative |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 10–20 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Positions | 120 |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Instrument |
| Model | TriSep™-2100 |
| Instrument Type | High-Voltage Power Supply for Capillary Electrophoresis |
| Output Mode | Bipolar / Positive-only / Negative-only |
| Voltage Range | 0 to ±30 kV |
| Current Range | 0 to 100 µA |
| Max Output Power | 4 W |
| Weight | 12 kg |
| Display | Digital Voltage & Current Readout |
| Control | Front-panel Programmable Timing Ramp & Manual Setpoint |
| Protection | Integrated Overvoltage/Overcurrent Alarm and Shutdown |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Application | Organic Analysis |
| Voltage Range | 0–30 kV |
| Cooling Method | Liquid Cooling |
| Capillary Temperature Control | Liquid-Cooled Thermostatic Module |
| Detector | UV-Vis Absorbance Detector |
| Injection Mode | Manual Pressure/Voltage-Assisted |
| Pressure Range | ±30 kV Equivalent Driving Force |
| Thermal Stability | ±0.1 °C (Typical under Steady-State Liquid Cooling) |
| Brand | Yamazen |
|---|---|
| Origin | Japan |
| Model | AKROS |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–80 mL/min |
| Flow Accuracy | RSD₆ ≤ 1% |
| Flow Precision (Repeatability) | RSD₆ ≤ 1% |
| Maximum Operating Pressure | 1.0 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Prep EasySep-1050 |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | 42 MPa |
| Autosampler Positions | 120 |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Rate | 100 Hz |
| Pump Flow Accuracy | ±2% |
| Pump Flow Precision | < 0.2% RSD |
| Pressure Pulsation | ≤0.2 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | < 0.1 nm |
| Baseline Noise | ≤±1×10⁻⁵ AU (MeOH, 1 mL/min, 254 nm, 1 s) |
| Baseline Drift | ≤2×10⁻⁴ AU/h (MeOH, 1 mL/min, 254 nm, 1 s) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TriSep®-3000 High-Efficiency Microfluidic Electro-HPLC System |
| Instrument Type | Nanoflow Liquid Chromatograph |
| Application Profile | Specialized Analytical Instrument |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Pressure | 40 MPa |
| Flow Precision | <0.06% RSD |
| Sample Tray Capacity | 1.5 mL vials (105 positions) or 5 mL vials (10 positions) |
| Injection Volume Range | 20 nL, 50 nL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | qSep™-3010 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Application | Organic Analysis |
| Voltage Range | 0 to ±30 kV |
| Cooling Method | Liquid Cooling |
| Capillary Temperature Control | Semiconductor-Based Peltier |
| Detector Options | UV/Vis (μUV/Vis), Laser-Induced Fluorescence (μLIF), Evaporative Light Scattering (μELSD), Electrochemical (μECD), Mass Spectrometry (MS) Interface |
| Injection Mode | Pressure- or Electrokinetic-Driven |
| Injection Volume Precision | 4 nL or 10 nL via Patented Loop Valve |
| Pressure Range | Low-Pressure Pneumatic |
| Column Oven Temperature Range | 4–50 °C |
| Compliance | GLP-ready software with audit trail, 21 CFR Part 11–compatible configuration available |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | 2100 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC)-compatible pCEC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detection Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |