- All
- Favorite
- Popular
- Most rated
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EasySep®3050PLC |
| Instrument Category | Conventional HPLC System |
| Application Scope | General-Purpose Preparative Chromatography |
| Flow Rate Range | 0–50 mL/min |
| Maximum Pressure | 42 MPa |
| Flow Accuracy | < 0.06% RSD |
| Autosampler Capacity | 24 positions (10 mL vials) |
| Injection Volume Range | 0–10 mL |
| Column Oven Temperature Range | 5 °C above ambient to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | EasySep®-5010 |
| Instrument Type | Conventional UHPLC System |
| Application Scope | General-purpose analytical chromatography |
| Maximum Operating Pressure | 68 MPa |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EasySep-1020 HPLC |
| Instrument Category | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | <0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient +10 °C to 60 °C |
| UV/Vis Wavelength Range | 190–600 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Model | EasySep®-3050 |
| Flow Rate Range | 0–50 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | 0–5 mL |
| Column Oven Temperature Range | –100 °C (requires optional cryogenic module) |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 20 Hz |
| Detector Options | UV-Vis, Diode Array (DAD), Fluorescence (FLD), Evaporative Light Scattering (ELSD), Mass Spectrometry (MS) interfaces |
| Software Control | Unimicro ChromStation (full bidirectional control) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Model | EasySep-1010 |
| Pump Types | Analytical (10 mL stainless steel head) & Semi-Preparative (50 mL stainless steel head) |
| Flow Range (Analytical) | 0.01–9.99 mL/min |
| Max Pressure (Analytical, SS) | 42 MPa |
| Flow Range (Semi-Prep) | 0.1–49.9 mL/min |
| Max Pressure (Semi-Prep, SS) | 30 MPa |
| Flow Accuracy (Analytical) | RSD ≤ 0.5% at 1 mL/min |
| Flow Precision (Analytical) | RSD ≤ 0.1% at 1 mL/min |
| Flow Accuracy (Semi-Prep) | RSD ≤ 2% at 1 & 10 mL/min |
| Flow Precision (Semi-Prep) | RSD ≤ 0.5% at 1 & 10 mL/min |
| UV-VIS Detector | Wavelength Range 190–360 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Spectral Bandwidth | 8 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Light Source | DX2 Dual-Life Deuterium Lamp |
| Detector Cell Options | Analytical & Semi-Preparative Flow Cells |
| Display | 320×240 dot-matrix LCD |
| System Protection | Soft-start/stop, programmable pressure limits, auto data backup |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | EasySep®-3030 Binary/Quaternary HPLC System |
| Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | 96 positions |
| Injection Volume Range | 0–100 µL |
| Column Oven Temperature Range | Ambient to 100 °C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | EasySep®-3030 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 42 MPa |
| Sample Tray Capacity | 108 positions (2 mL vials) |
| Injection Volume Range | 0–100 µL |
| Column Oven Temperature Range | Ambient to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 20 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EasySep-1050 Semi-Preparative |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 10–20 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Positions | 120 |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Prep EasySep-1050 |
| Flow Rate Range | 0.001–9.999 mL/min |
| Max Operating Pressure | 42 MPa |
| Autosampler Positions | 120 |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Rate | 100 Hz |
| Pump Flow Accuracy | ±2% |
| Pump Flow Precision | < 0.2% RSD |
| Pressure Pulsation | ≤0.2 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | < 0.1 nm |
| Baseline Noise | ≤±1×10⁻⁵ AU (MeOH, 1 mL/min, 254 nm, 1 s) |
| Baseline Drift | ≤2×10⁻⁴ AU/h (MeOH, 1 mL/min, 254 nm, 1 s) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TriSep®-3000 High-Efficiency Microfluidic Electro-HPLC System |
| Instrument Type | Nanoflow Liquid Chromatograph |
| Application Profile | Specialized Analytical Instrument |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Pressure | 40 MPa |
| Flow Precision | <0.06% RSD |
| Sample Tray Capacity | 1.5 mL vials (105 positions) or 5 mL vials (10 positions) |
| Injection Volume Range | 20 nL, 50 nL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Unimicro Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | 2100 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC)-compatible pCEC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–250 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detection Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |