BrandLeici
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelCOD-580
Instrument TypeOnline Analyzer
Measurement PrincipleElectrochemical Oxidation (Hydroxyl Electrode Method)
Measurement Range10.0–1000 mg/L
Resolution0.1 mg/L
Accuracy±5% of Full Scale (FS)
Repeatability≤3% FS
Zero Drift±5 mg/L per 24 h
Span Drift±10% per 24 h
Power SupplyAC 220 V ±10%, 50 Hz ±1%
Dimensions (W×D×H)600 × 455 × 720 mm
Weight50 kg
Interface OptionsRS-232 standard
Display7-inch color touchscreen with Chinese UI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeiCi
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelDGS-450
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrinciplePotassium Dichromate Digestion Method (for COD), Nesslerization (for Ammonia-N), Molybdate Blue Spectrophotometry (for Total Phosphorus), Alkaline Potassium Persulfate Digestion with Chromotropic Acid (for Total Nitrogen)
Wavelengths420 nm, 470 nm, 620 nm, 700 nm
COD Range(0.000–1500) mg/L (extendable to 15,000 mg/L)
Ammonia-N Range(0.000–10.00) mg/L (extendable to 100.0 mg/L)
Total Phosphorus Range(0.000–1.000) mg/L (extendable to 10.00 mg/L)
Total Nitrogen Range(0.000–30.00) mg/L (extendable to 300.0 mg/L)
Absorbance Range(0.000–2.000) Abs
Wavelength Accuracy±4 nm
Transmittance Error±2%
Photometric Repeatability≤0.5%
Ammonia-N Accuracy±5%
COD & Total Phosphorus & Total Nitrogen Accuracy±8% (COD & TP), ±1 mg/L (≤10 mg/L TN) or ±5% (>10 mg/L TN)
Repeatability (all parameters)≤3%
Detection LimitsAmmonia-N ≤0.03 mg/L
Cell Format25 mm cuvette / 16 mm tube
Power SupplyAC 100–240 V input, DC 20 V output
Dimensions302 × 205 × 122 mm
Weight1.33 kg
Data Storage500 records per parameter
InterfaceRS-232, USB-B, U-disk export support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeichi
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelCOD-582
Instrument TypeOnline Analyzer
Measurement PrinciplePotassium Dichromate Digestion Method (Online)
Measurement Range10.0–5000 mg/L
Accuracy±10% or ±5 mg/L (for values ≤50 mg/L)
Repeatability5% or 5 mg/L (for values ≤100 mg/L)
Resolution0.1 mg/L (≤100 mg/L), 1 mg/L (>100 mg/L)
Zero Drift±5 mg/L/24 h
Span Drift±10%/24 h
Power SupplyAC 220 V ±10%, 50 Hz
Dimensions (W×D×H)550 × 400 × 1680 mm
Weight50 kg
MTBF≥360 hours
OutputIsolated 4–20 mA DC (configurable upper/lower limits)
CommunicationRS-232 or RS-485 (selectable)
Interface7-inch color LCD touchscreen
Maintenance IntervalUp to 30 days without service
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelCOD-572
Price RangeUSD 700 – 1,400 (FOB Shanghai)
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleCoulometric Titration (ASTM D1252–04, ISO 8467:1993 compliant)
COD Range(0.0–100.0) mg/L (standard), extendable to (100.0–1000) mg/L via dilution or high-range mode
Accuracy±2 mg/L (absolute error at ≤100 mg/L)
RepeatabilityRSD ≤ 2%
Power SupplyAC 220 V ±10%, 50 Hz ±1%
Dimensions (W×D×H)300 × 235 × 100 mm
Weight3.0 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeici
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelCOD-571
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleDichromate Digestion Method (2-hour standard digestion per ISO 6060 / HJ 828–2017)
Wavelengths420 nm and 620 nm
Measurement Ranges0–150 mg/L (low-range), 0–1500 mg/L (high-range)
Accuracy±8% of reading
Repeatability≤3% RSD
Measurement Time~20 min post-digestion
ThroughputBatch analysis of multiple water samples
Absorbance Range0.000–2.000 Abs
Absorbance Accuracy±0.01 Abs or ±5%
Absorbance Repeatability≤0.005 Abs or 2%
Wavelength Accuracy±4 nm
Transmittance Error±2%
Transmittance Repeatability≤0.5%
Cuvette Compatibility10 mm square cuvettes and 16 mm round test tubes
Data Storage2000 measurement records with timestamp, sample ID, dilution factor, and calibration metadata
ConnectivityRS-232, USB-B, optional U disk export
Power SupplyAC 100–240 V input / DC 24 V output adapter
Dimensions302 × 205 × 122 mm
Weight1.33 kg