| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | KLS-411 |
| Pricing Range | USD 570 – 2,850 (based on current exchange rate ~¥4000–¥20,000) |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg to 20 mg |
| Measurement Accuracy | ≤ ±3% RSD |
| Electrolysis Current Settings | 10 mA, 20 mA, 50 mA, 100 mA |
| Polarization Current Error | ±0.2 µA |
| Electrolysis Current Basic Error | ±0.5% of reading |
| Indication Error | ±(5% of calibration point + 3) µg |
| Repeatability | ≤3% RSD |
| Power Supply | (220 ± 22) V AC, (50 ± 1) Hz |
| Dimensions (L×W×H) | 300 × 235 × 100 mm |
| Net Weight | 3 kg |
| Interface | RS-232 serial port for printer connectivity |
| Electrode Configuration | Membrane-type dual-platinum electrode |
| Reagent Compatibility | Leici low-toxicity, low-odor, reusable KF reagent (coulometric anolyte/catholyte system) |
| Reagent Standardization | Not required (pre-calibrated reagent system) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SFK-506VC |
| Pricing | ¥88,900 CNY |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3.0 μg – 200 mg (Coulometric), 100 μg – 250.0 mg (Volumetric) |
| Resolution | 0.1 μg (Coulometric), 1 μg (Volumetric) |
| Accuracy | ±0.3% |
| Repeatability | ≤0.3% |
| Polarization Current Range | (1–200) μA |
| Titration Control Precision | 0.1 μg |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Data Storage | 2000 records per method (volumetric & coulometric) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Method | Fully Automatic |
| Moisture Measurement Range | 10.0 µg – 200 mg |
| Resolution | 0.1 µg |
| Repeatability | ≤1% |
| Electrolysis Current Stability | ±0.2% / 10 min |
| Polarization Current Error | ±3% |
| Polarization Current Stability | ±2.5% / 30 min |
| Potential Measurement Range | 0–2000 mV |
| Potential Resolution | 0.1 mV |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Dimensions (L×W×H) | 240 × 370 × 270 mm |
| Weight | ~3 kg |
| Data Storage Capacity | 200 measurement records |
| Interface Support | RS-232 (printer), USB (scanner, moisture control software, U-disk export), optional KF oven coupling |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Range | 3.0 µg – 200 mg H₂O |
| Resolution | 0.1 µg |
| Repeatability | ≤0.3% |
| Titration Method | Fully Automated Coulometric Titration |
| Dimensions (L×W×H) | 240 mm × 370 mm × 270 mm |
| Weight | ~4 kg |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Electrolysis Current Accuracy | ±0.5% |
| Electrolysis Current Stability | ±0.2%/10 min |
| Polarization Current Range | 1–200 µA |
| Polarization Current Error | ±3% |
| Polarization Current Stability | ±2.5%/30 min |
| Potential Measurement Range | 0–2000 mV |
| Potential Resolution | 0.1 mV |
| Data Storage Capacity | 2000 test records |
| Connectivity | RS-232, USB (for balance, barcode scanner, printer), WLAN/WiFi, U disk export |
| Compliance | GLP-compliant architecture, GMP-ready audit trail, 21 CFR Part 11–compatible data management framework |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ZDY-501 |
| Pricing Range | USD 570 – 2,850 |
| Titration Mode | Fully Automatic |
| Method Type | Volumetric and Coulometric Karl Fischer |
| Moisture Measurement Range | 0.1 mg – 250 mg |
| Measurement Accuracy | ±3% |
| Polarization Current | 1 µA |
| Endpoint Detection Range | 40–120 mV |
| Sample Temperature Range | 5–30 °C |
| Dimensions (L×W×H) | 280 × 210 × 120 mm |
| Weight | 5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | ZDY-504 |
| Pricing | USD 5,300 (FOB Shanghai) |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 mg |
| Moisture Content Range | Volumetric: 0.1–250.0 mg H₂O |
| Coulometric | 10 µg–20 mg H₂O |
| Accuracy | Volumetric: ≤0.5% RSD |
| Coulometric | ≤3% RSD at 100 µg H₂O |
| Minimum Dispensing Volume | 0.005 mL |
| Repeatability | Volumetric: ≤0.5% RSD |
| Coulometric | ≤3% RSD at 100 µg H₂O |
| Polarization Current Settings | 10.722 mA, 20 mA, 53.61 mA, 107.22 mA |
| Burette Capacity | 10 mL |
| Titration Control Precision | 1/12,000 |
| Power Supply | (220 ± 22) V AC, (50 ± 1) Hz |
| Data Storage Capacity | 200 measurement records |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SFK-506V |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 100 µg – 250.0 mg |
| Measurement Resolution | 1 µg |
| Repeatability | ≤0.3% |
| Potentiometric Range | 0–2000 mV |
| Potentiometric Resolution | 0.1 mV |
| Polarization Current Range | 1–200 µA |
| Polarization Current Accuracy | ±3% |
| Polarization Current Stability | ±2.5% / 30 min |
| Power Supply | 80–305 VAC, 47–63 Hz |
| Dimensions (W×D×H) | 240 × 370 × 270 mm |
| Weight | ~4 kg |
| Data Storage Capacity | 2000 test records |
| Communication Interfaces | RS-232, USB (for balance, barcode scanner, heating oven), WLAN/WiFi |
| Output Options | PDF report export, thermal/USB printer support, U-disk data export |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | 0.1–250.0 mg |
| Resolution | 1 µg |
| Accuracy | ±7% |
| Repeatability | ≤0.5% (for samples containing >10 mg water) |
| Titration Mode | Fully Automatic |
| Electrode Potential Range | 0–2000 mV |
| Potential Resolution | 1 mV |
| Polarization Current Error | ±3% |
| Polarization Current Stability | ±2.5% over 30 min |
| Power Supply | 80–305 VAC, 47–63 Hz |
| Dimensions (W×D×H) | 240 × 370 × 270 mm |
| Weight | ~4 kg |
| Data Storage Capacity | 200 methods/results |
| Interface | RS-232, USB, U-disk export support |
| Compliance | GLP-compliant data traceability, multi-level user authentication |