- All
- Favorite
- Popular
- Most rated
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | LineGene Mini |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 16 × 0.2 mL tubes (flat, optically transparent caps) or 8 × 0.2 mL tubes (flat, optically transparent caps) |
| Reaction Volume | 10–100 μL |
| Dynamic Range | 1–10¹⁰ copies |
| Temperature Range | 0–100 °C (0.1 °C increment) |
| Temperature Control Accuracy | ≤ ±0.1 °C |
| Max Heating/Cooling Rate | 5 °C/s |
| Thermal Lid Temperature | 30–110 °C (adjustable, default 105 °C) |
| Fluorophore Channels | F1: FAM, SYBR Green I |
| F2 | VIC, HEX, TET, JOE, TAMRA, CY3 |
| F3 | ROX, Texas Red |
| F4 | CY5, Quasar-670 |
| Power Input | DC 24 V, 180 W |
| Dimensions (L×W×H) | 280 × 220 × 240 mm |
| Net Weight | 6.5 kg |
| Safety Features | Short-circuit/open-circuit detection for module/thermal lid/heat sink temperature sensors |
| Interface | USB |
| Preheat Time | None required |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Sample Capacity | 96 × 0.2 mL tubes |
| Temperature Range | 4–105°C (0.1°C resolution) |
| Max Heating Rate | 6°C/s |
| Max Cooling Rate | 5.5°C/s |
| Temperature Uniformity | ≤ ±0.2°C |
| Temperature Accuracy | ≤ ±0.1°C (measured 30 s after reaching 55°C, 72°C, or 95°C) |
| Heat Lid Temperature | 30–110°C |
| Gradient Range | 1–30°C |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temperature Increment/Decrement | 0.1–9.9°C |
| Program Storage | Unlimited (2000 onboard + USB/LAN/WiFi expansion) |
| Connectivity | USB, LAN, Wi-Fi |
| Power Input | 100–240 VAC, 50–60 Hz, 600 W |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Net Weight | 10.5 kg |
| Heat Lid Actuation | Single-step mechanical lock |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96 × 0.2 mL (compatible with single tubes, 8-tube strips, and 96-well plates) |
| Heating Rate | 6.5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ≤ ±0.2 °C |
| Temperature Range | 4–105 °C (0.1 °C increment) |
| Fluorophore Channels | 6-channel detection (FAM/SYBR Green I, VIC/HEX/TET/JOE/TAMRA/Cy3 NED, ROX/Texas Red, Cy5, Cy5.5) |
| Dynamic Range | 1–10¹⁰ copies/L |
| Reaction Volume | 10–100 µL |
| Thermal Control Mode | Block control & simulated tube control |
| Heat Lid Temperature | 30–110 °C (default 105 °C) |
| Power Input | 100–240 V, 50/60 Hz, 1000 VA |
| Interface | USB, Bluetooth |
| Dimensions | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Safety Certifications | CE, RoHS 2 compliant |
| Brand | bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | LineGene K Plus |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 48 × 0.2 mL (compatible with individual tubes and 8-tube strips) |
| Reaction Volume | 5–100 µL |
| Detection Channels | 4 |
| Excitation Sources | High-intensity LEDs (FAM/SYBR Green I |
| Block Temperature Range | 4–105 °C (0.1 °C resolution) |
| Max Heating Rate | 5 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Inter-well Uniformity | ≤ ±0.1 °C |
| Heat Lid Temperature Range | 30–110 °C (default 105 °C, auto-lift mechanism) |
| Independent Three-Zone Thermal Control | Adjustable gradient range 0.1–6 °C per zone |
| Operating System Compatibility | Windows XP / 7 / 8 / 10 |
| Interface Options | USB, RS232, Bluetooth |
| Power Input | 100–240 V AC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Weight | 28 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Sample Capacity | 96-well plate / 12×8 strip tubes / 96×0.2 mL single tubes (bottom-transparent) |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.1°C |
| Fluorescence Channels | 6 (FAM/SYBR Green I |
| Dynamic Range | 1–10¹⁰ copies |
| Excitation Source | Long-life LED |
| Detection Mode | Bottom-scanning optical system |
| Thermal Block Control Modes | Block mode & Simulated Tube mode |
| Gradient Range | 1–36°C |
| Thermal Lid Temp Range | 30–110°C (auto-adjusting) |
| Power Input | 100–240 VAC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Certifications | CE, RoHS 2, MEC, MET, PICC Product Liability Insurance, China NMPA Registration No. 20153400273 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | LineGene Mini S |
| Sample Capacity | 16 × 0.2 mL tubes or 2 × 8-tube strips (0.2 mL) |
| Power Input | 100–240 V, 50/60 Hz |
| Communication Interfaces | Ethernet port (for PC connectivity), Bluetooth 4.2 |
| Dimensions (L×W×H) | 240 mm × 180 mm × 160 mm |
| Net Weight | 4.0 kg |
| Regulatory Compliance | CE-IVD compliant per EN ISO 13485:2016 |
| Brand | Forevergen |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MicroDrop-100 |
| Instrument Type | Droplet Digital PCR System |
| Sample Volume | 20 µL |
| Microdroplets per Reaction | 100,000 |
| Droplet Generation Time | 2 min/chip |
| Throughput (Prep) | 1–8 samples/chip |
| Throughput (Detection) | 1–96 samples/run |
| Linear Dynamic Range | 6 logs |
| Sensitivity | 0.01% (1 in 10,000) |
| Detection Channels | FAM, HEX (VIC) |
| Dimensions (MicroDrop-100A) | 300 × 400 × 145 mm |
| Dimensions (MD Detector) | 700 × 500 × 325 mm |
| Software | QuantDrop Analysis Suite |
Show next