| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical Use |
| Pump Configuration | Reciprocating Dual-Piston Isocratic or Binary High-Pressure Gradient Capable |
| Detector | UV-Vis with Variable Wavelength (VWL) Capability |
| Column Oven | PID-Controlled Temperature Regulation |
| Data Acquisition | 24-bit ADC, Low-Drift Preamp, Integrated Touchscreen Workstation (Audit Trail Optional) |
| Compliance Readiness | GLP/GMP-Aligned Architecture, FDA 21 CFR Part 11–Ready Software Framework |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Linear Ion Trap |
| Application Field | General-Purpose |
| Mass Range | m/z 50–1000 |
| Sensitivity | 0.5 ng/mL (for standard test compound under defined LC-MS conditions) |
| Resolution | ≤0.5 Da (FWHM at m/z 500) |
| Dimensions | 33.3 × 23.5 × 14.6 cm |
| Weight | 8.5 kg |
| Battery Life | Up to 2 hours (integrated Li-ion power supply) |
| Vacuum System | Dual-stage non-continuous atmospheric pressure interface (DAPI) with built-in turbomolecular pump |
| Analysis Time | <3 minutes from sample introduction to report-ready output |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 1600 |
| Price | Upon Request |
| Wavelength Range | 325–1100 nm |
| Wavelength Repeatability | ≤1 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.4% T |
| Optical System | Single-Beam with 1200 lines/mm Holographic Grating |
| Display | Large Backlit LCD (Wavelength Resolution: 1 nm) |
| Data Storage | Up to 100 calibration curves and 2000 measurement records |
| Interface | RS-232, USB flash drive support, Bluetooth 4.2 (for data export, mobile app sync, and optional thermal printer) |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Time | 999.99 min (maximum runtime) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| Power Requirement | 220 V (±10%), 47.5–63 Hz, 1500 W (100 V: 2250 W) |
| Weight | 50 kg |
| Compliance | IEC/EN 61010, UL 61010, CSA C22.2 No. 61010, CISPR 11/EN 55011 Class A, ISO 9001 |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 400 °C |
| Oven Ramp Rate | 0.1–120 °C/min |
| Cooling Mechanism | Low Thermal Mass (LTM) module enables rapid column heating and cooling |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | up to 970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | up to 970 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Operating Pressure | 42 MPa |
| Fluidic Path Material | Full-PEEK & PTFE/PEEK/PP Non-Metallic Construction |
| Pump Configuration | Integrated Quaternary Gradient Pump with Electrolytic Eluent Generation |
| Detector Options | Conductivity, Pulsed Amperometric (PAD), UV-Vis, Fluorescence |
| Compliance Support | ASTM D4327, ISO 10304-1/-3, USP <645>, EPA Methods 300.0/317.0/321.8 |