Empowering Scientific Discovery

Shenbei Scientific Instruments (Suzhou) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
Brand1124123/13213112
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Instrument TypeConventional HPLC System
Application ScopeGeneral-Purpose Analytical Use
Pump ConfigurationReciprocating Dual-Piston Isocratic or Binary High-Pressure Gradient Capable
DetectorUV-Vis with Variable Wavelength (VWL) Capability
Column OvenPID-Controlled Temperature Regulation
Data Acquisition24-bit ADC, Low-Drift Preamp, Integrated Touchscreen Workstation (Audit Trail Optional)
Compliance ReadinessGLP/GMP-Aligned Architecture, FDA 21 CFR Part 11–Ready Software Framework
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent
OriginUSA
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range8 °C to 425 °C
Maximum Ramp Rate75 °C/min
Cooling Time999.99 min (maximum runtime)
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Control0–970 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setpoint Range0–970 psi
Injector Total Flow Setpoint Range0–1200 mL/min
Column Oven Dimensions28.0 × 30.5 × 16.5 cm
Retention Time Reproducibility< 0.06% RSD
Peak Area Reproducibility< 2% RSD
Power Requirement220 V (±10%), 47.5–63 Hz, 1500 W (100 V: 2250 W)
Weight50 kg
ComplianceIEC/EN 61010, UL 61010, CSA C22.2 No. 61010, CISPR 11/EN 55011 Class A, ISO 9001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent
OriginUSA
Model7890B
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range400 °C
Oven Ramp Rate0.1–120 °C/min
Cooling MechanismLow Thermal Mass (LTM) module enables rapid column heating and cooling
Carrier Gas Flow Range & Control0–1200 mL/min
Carrier Gas Pressure Range & Controlup to 970 kPa
Injector Maximum Operating Temperature400 °C
Injector Pressure Setting Rangeup to 970 kPa
Total Injector Flow Setting Range0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He)
Added to wishlistRemoved from wishlist 0
Add to compare
Brand1124123/13213112
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory Benchtop System
Application ScopeGeneral-Purpose Ion Analysis
Maximum Operating Pressure42 MPa
Fluidic Path MaterialFull-PEEK & PTFE/PEEK/PP Non-Metallic Construction
Pump ConfigurationIntegrated Quaternary Gradient Pump with Electrolytic Eluent Generation
Detector OptionsConductivity, Pulsed Amperometric (PAD), UV-Vis, Fluorescence
Compliance SupportASTM D4327, ISO 10304-1/-3, USP <645>, EPA Methods 300.0/317.0/321.8
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0