Empowering Scientific Discovery

Shenzhen Angwei Electronics Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADOS
OriginGermany
ModelTOX 592
Instrument TypeSingle-Channel Electrochemical Gas Transmitter
Measurement PrincipleAmperometric Electrochemistry
Measurable GasesCO (0–300 ppm), NH₃ (0–200 ppm), NO₂ (0–30 ppm), SO₂ (0–50 ppm), H₂S (0–20 ppm), O₃ (0–5 ppm)
Zero Error<10 ppm CO
Baseline Drift<2% per year
Accuracy±3% of full scale
Linearity<2% of full scale
Response Time (t₉₀)<60 s
Cross-Sensitivity<2% with integrated filter
Output0–4–20 mA (2-wire) or LON® (4-wire, 78 kbps)
Supply Voltage15–30 V DC (max. load 100–500 Ω)
Operating Temperature–10°C to +40°C (with sensor temperature compensation)
Humidity Range10–99% RH (non-condensing)
Sensor Lifetime~2 years
Sensor DimensionsØ80 mm × H80 mm
Weight600 g
ComplianceVDI 2053 (Germany), EN 45544-1/-2, IEC 60079-29-1 (for hazardous area variants, optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADOS
OriginGermany
ModelGTR210 / GTR210 MED
Instrument TypeSingle-Channel Intrinsically Safe Gas Transmitter
Explosion ProtectionII 2G Ex db e ia mb IIC T4 Gb
ATEX CertificateDEKRA 11 ATEX 0257 X
IECEx CertificateIECEx DEK 11.0090 X
MED CertificationDirective 2014/90/EU, Approval No. MEDB00006EV
Power Supply24 V DC (+10% / −25%) / 230 V AC 50 Hz / 115 V AC 60 Hz (optional)
Output Signal4–20 mA (3-wire), LON (4-wire optional)
Relay Outputs4 dry-contact alarm/fault relays + 1 reset input
Enclosure RatingIP66/IP67 (standard), IP54 (optional)
Operating Temperature−25 °C to +60 °C
Weight2.3 kg (GTR210 EX), 1.8 kg (GTR210 standard), 2.0 kg (GTR210 MED)
Sensor TechnologiesSemiconductor (TGS), Catalytic Bead (VQ), Thermal Conductivity (GOW), Electrochemical (TOX), Infrared (IR), Photoionization (PID), Paramagnetic (O₂)
Typical Response Times30–120 s depending on sensor type
Full-Scale Accuracy±2 % to ±5 % FS
Temperature Drift≤2 % to 5 % of reading per 10 K
Pressure Influence≤1 % FS per bar
Sensor Lifetime12 months (PID) to 7 years (electrochemical, IR, catalytic)
Mounting OptionsWall-mount, pipe-mount, flange-mount (vacuum or explosion-proof variants available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandADOS
OriginGermany
ModelGTR196
Instrument TypeSingle-Channel Fixed Gas Transmitter
Explosion ProtectionII 2G Ex d e mb [ia] IIC T6 (KEMA 03 ATEX 2403 X)
Enclosure RatingIP54
Dimensions100 × 180 × 80 mm (O₂ version: 100 × 200 × 80 mm)
Weight1.1 kg
Power Supply15–30 V DC
Output Signal4–20 mA (3-wire) or galvanically isolated 4-wire interface
Data Transfer Rate78 kB/s
Operating Temperature−20 °C to +45 °C
Sensor PrinciplesMetal Oxide Semiconductor (TGS), Catalytic Bead (VQ), Electrochemical (TOX), Non-Dispersive Infrared (NDIR), Photoionization Detection (PID)
Measurable GasesO₂, CO, NH₃, NO₂, SO₂, H₂S, CH₄ (vol% & LEL), C₃H₈ (LEL), CO₂ (0–5 vol%), VOCs (e.g., C₇H₈, C₈H₁₀, CHCl₃), PH₃
Full-Scale Accuracy±2–5% FS depending on sensor type
Response Time (T₉₀)45–120 s
Zero/Full-Scale Drift<2% FS/year
Linearity<2% FS
Temperature Influence≤2–5% of reading
Pressure Influence≤1%
Cross-Sensitivity<2% with integrated particulate filter
Show next