Empowering Scientific Discovery

Shenzhen Angwei Electronics Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMKS
OriginUSA
ModelMG6030
Instrument TypeOnline FTIR Spectrometer
Wavenumber Range10 ppb to 100% (gas-phase concentration)
Spectral Resolution0.5–128 cm⁻¹
Scan Speed5 scans/sec at 0.5 cm⁻¹
DetectorLiquid-nitrogen-cooled or thermoelectrically cooled MCT (HgCdTe)
Optical Path Length5.11 m
Purge GasDry N₂ or CO₂-free air (dew point < −70 °C), flow rate 0.2 L/min
Pressure SensorMKS Baratron® capacitance manometer
Sample Temperature RangeAmbient to 200 °C
Sample Flow Rate0.2–10 L/min
Sample Pressure Range0.01–4 atm
Enclosure MaterialNickel-plated aluminum or 316 stainless steel
Weight50 kg
Dimensions445 mm (W) × 318 mm (H) × 648 mm (D)
Power110/220 VAC, 50/60 Hz, 3 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelUYI-U800
Response Time10–30 s (for CH₄, CO₂, O₂)
Explosion Protection RatingEx d IIC T6 Gb
Enclosure OptionsFlameproof (Ex d) or Non-Flameproof Cabinet
Measurement Channels1–8 configurable sampling points
Operating Temperature−5 °C to +50 °C
Power Supply220 VAC ±5%, 1 A
DisplayIndustrial-grade capacitive touch screen
Output4–20 mA analog + RS485 Modbus RTU
Flow Rate500 mL/min (typical)
FilterReplaceable fiber filter cartridge
Weight~45 kg
Dimensions (standard)600 × 600 × 250 mm (W × D × H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMichell Instruments
OriginUnited Kingdom
Model SeriesEA2, DMT143, DMT152
ApplicationLaboratory & Process-Grade Dew Point Measurement
Accuracy±2 °Cdp
CertificationsATEX, IECEx, UKCA, cQPSus
Sensor TechnologyCeramic Alumina (EA2), Vaisala DRYCAP® Polymer (DMT143/DMT152)
Output Options4–20 mA, 0–10 V, RS-485 Modbus RTU
Electrical InterfaceMiniDIN 43650 (EA2), M12 (DMT143/DMT152)
Process Connections5/8″ UNF, 3/4″ UNF, G 1/2″, KF40 Flange
Materials316 Stainless Steel Wetted Parts
CalibrationNPL/NIST-Traceable Certificate Supplied
Typical Response Time<10 s (t₉₀, DMT143/DMT152)
Operating Ambient−40 to +60 °C
IP RatingIP65 (EA2), IP66 (DMT143/DMT152)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD NMHC
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Analyzer
Measurement Range0–10,000 ppmC₁ (as methane equivalent)
Response Time1 s (T₉₀)
Detector Temperature190 °C
Filter Temperature300 °C
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Warm-up Time15 min
Analog Output0–20 mA / 0–10 V
Digital InterfaceEthernet, RS232
Data StorageUSB
Remote AccessVNC/PC
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Ambient Temperature0–45 °C
Enclosure RatingIP40
Dimensions19″ Rack, 133 × 482 × 420 mm
Weight15 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Zero GasN₂ or synthetic air
Calibration GasC₃H₈
Combustion AirInternally pumped
Fuel Consumption70 mL/min H₂ or 400 mL/min He/H₂
Calibration Gas Flow1 L/min
Pressure Compensation Range−150 to +500 hPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMCQ
OriginItaly
ModelGB15K
Inlet Channels3
Outlet Channels1
Flow Range per Channel0–15,000 mL/min
Dilution Ratio1–1000
Third-Party Software CommunicationYes
Compatible GasesN₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂ (custom gases available upon consultation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGermany
ModelCONTHOS 3E PMD
Measurement PrincipleTemperature-Controlled Paramagnetic (Dumbbell-Type) Sensor
Response Time<5 s (gas-flow- and configuration-dependent, configurable integration time)
Measuring RangesUp to 3 independently configurable, switchable ranges (standard: 0–100% O₂ or 0–25% O₂
min. range0–5% O₂
max. range0–100% O₂)
Detection Limit<1% of span
Repeatability<±0.03% O₂
Inherent Linearity / Accuracy±0.1% O₂ (full scale)
Zero Drift<±0.1% O₂/week
Temperature EffectZero shift <±0.5% O₂ per 10 K
Tilt SensitivityBaseline shift of 0.02% O₂ per 1° deviation from horizontal
CalibrationManual 2-point (zero/span)
Pressure CompensationOptional, 800–1200 mbar abs (extendable on request)
Interference CompensationStatic and dynamic correction supported (requires proportional selectivity signal for dynamic mode)
Operating Detector Temperature55 °C
Enclosure RatingIP65 (per EN 60529)
Output InterfacesRS-485 (Modbus RTU), optional digital I/O panel for external range switching and threshold logic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMADUR
OriginItaly
ModelNOVO
Instrument TypePortable Flue Gas Analyzer
Accuracy≤ ±0.5% FS
Dimensions270 × 93 × 68 mm
Weight0.9 kg
Operating Temperature+5 °C to +45 °C
Storage Temperature+5 °C to +45 °C
Power SupplyRechargeable Li-ion battery (6–8 h runtime)
Display7-inch capacitive touchscreen
ConnectivityBluetooth 4.2, USB 2.0
ComplianceEN 50379-1 & EN 50379-2
Sensor TechnologiesElectrochemical (O₂, CO, NO, NO₂, SO₂, H₂, H₂S, NH₃), Catalytic Combustion (CxHy), NDIR (CH₄, CO₂)
Max Simultaneous Gases4 sensor channels (configurable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSensors
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNGM
Price RangeUSD 2,600 – 3,900
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD NMHC mobile
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Detection Range0–100,000 ppmC₁
Response Time1 s (T₉₀)
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Detector Temperature190 °C
Hot Filter Temperature300 °C
Preheat Time15 min
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Temperature0–45 °C
Enclosure RatingIP40
Dimensions178 × 370 × 420 mm
Weight12 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Calibration GasesC₃H₈, CH₄, C₂H₆
Zero GasN₂ or synthetic air
Burner AirBuilt-in pump
Fuel Consumption30 mL/min (H₂)
Calibration Gas Flow1 L/min
Pressure Compensation Range−150 to +500 hPa
Analog Output0–20 mA / 0–10 V
Digital InterfacesEthernet, RS232
Data StorageInternal via USB
Remote ControlVNC-compatible (PC/iFiD host)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelUE2040
Instrument TypePortable
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Target GasCH₄ (Methane)
Measurement Range0–100 ppm (FS) and 0–40,000 ppm (FS)
LOD (2σ)≤0.4 ppm (standard), ≤0.15 ppm with 10-s averaging
Accuracy (2σ)≤0.8 ppm (low range), ≤0.25 ppm/10 s (low range), ≤250 ppm (high range), ≤100 ppm/10 s (high range)
Sampling Frequency2 Hz
Response Time (T90)≤1.8 s at 2 L/min
Resolution0.01 ppm
Linearity & RepeatabilityIncluded in accuracy specification
Cross-InterferenceApplication- and gas matrix-dependent
Output SignalsRS485, 4–20 mA
Operating Temperature−10 to +65 °C
Operating Humidity0–99% RH (non-condensing)
Operating Pressure800–1100 mbar
Storage Temperature−40 to +80 °C
Storage Humidity0–99% RH (non-condensing)
Power Supply10–30 VDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelsCS31, CS-1, UE30
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGeotech (UK)
OriginUSA
ModelG100/G110/G150
Instrument TypePortable
Detection TargetMulti-component (CO₂, optional O₂)
CO₂ Range0–20% (G100), 0–100% (G110), 0–10,000 ppm (G150)
O₂ Range (optional)0–100%
CO₂ Accuracy±1% FS
O₂ Accuracy±1.0% FS
Resolution0.1 ppm (for G150)
Repeatability±1%
Response Time (T90)≤20 s (CO₂), ≤60 s (O₂)
Zero Drift<5% FS/yr
Span Drift<1% FS/yr
Linearity Error<2% FS
Operating Temperature0–50 °C
Relative Humidity0–95% RH (non-condensing)
Pressure Range800–1200 mbar
Display128×64 pixel backlit LCD
Data Storage1,000 readings + 270 event logs (with optional software)
BatteryRechargeable Li-ion, 12 h typical life (8 h with pump active)
Weight495 g
Dimensions165 × 100 × 155 mm
Enclosure MaterialABS
IP RatingIP40
Flow Rate100 mL/min
Measurement PrincipleDual-wavelength non-dispersive infrared (NDIR) for CO₂
CalibrationFactory-calibrated at 20 °C, 1000 mbar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelUE55
Price RangeUSD 4,200 – 7,000 (FOB Shenzhen)
Linearity Error< ±2% of Full Scale
Repeatability< ±2% of Full Scale (per year)
Response Time (T90)~30 s (NDIR channels)
Ingress ProtectionIP54 / IP65
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelUE55
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypeOnline Continuous Analyzer
Measurement Range5 selectable full-scale ranges with auto-ranging capability
Response Time (T90)<1.5 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGeotech (UK)
OriginUSA
Manufacturer StatusAuthorized Distributor
Product CategoryImported
ModelEM 5K (GEM 5000)
Product TypeBiogas Analyzer
Measurement RangeCH₄ 0–100% vol, CO₂ 0–100% vol, O₂ 0–25% vol, CO 0–2000 ppm, H₂S 0–10,000 ppm (configurable), NH₃ 0–1000 ppm, H₂ 0–1000 ppm
ResolutionCH₄/CO₂ ±0.5% vol (0–70%/0–60%), O₂ ±1.0% vol (0–25%), CO ±1.0–2.0% FS, H₂S ±1.5–2.0% FS
Minimum Measurable RangeAs per sensor configuration
Response Time (T90)CH₄/CO₂ ≤10 s, O₂ ≤20 s, H₂S/CO ≤30 s, NH₃/H₂ ≤90 s
Operating PrincipleDual-channel NDIR for CH₄/CO₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGeotech (UK)
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelES 5K (Biogas 5000)
Price RangeUSD 6,800 – 13,600
CertificationATEX II 2G Ex ib IIA T1 Gb
Measurement PrincipleDual-Channel NDIR for CH₄/CO₂
Gas RangeCH₄ 0–100% vol, CO₂ 0–100% vol, O₂ 0–25% vol, H₂S 0–50/500/5,000/10,000 ppm, CO 0–500/1,000/2,000 ppm, NH₃ 0–1,000 ppm, H₂ 0–1,000 ppm
AccuracyCH₄ & CO₂ ±0.5% vol (0–70%/0–60%), ±1.5% vol (higher ranges)
Response Time (T90)CH₄/CO₂ ≤10 s, O₂ ≤20 s, H₂S/CO ≤30 s, NH₃/H₂ ≤90 s
BatteryRechargeable NiMH pack, 8 h continuous operation
Enclosure RatingIP65
Operating Temp−10 to +50 °C
Dimensions220 × 155 × 60 mm
Weight1.5 kg
Data Storage500 measurement sets across 10 user-defined IDs
ConnectivityUSB 2.0 & Bluetooth 4.2
Pressure Measurement±500 mbar (±4 mbar accuracy), atmospheric range 500–1500 mbar (±5 mbar)
Temperature Probe Option−10 to +75 °C (±0.5 °C)
Flow Rate550 mL/min (pump), fault threshold at −200 mbar, auto-restart at ≈−375 mbar
FilterReplaceable 2.0 µm PTFE hydrophobic membrane
AlarmConfigurable visual & audible alerts
Language SupportUser-selectable UI languages
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErsatec
OriginGermany
ModelSmartFID
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Typical ConfigurationComposite VOC Analyzer
Measurement Range0–100,000 ppm (as C₃H₈)
Resolution0.01 ppm
Accuracy±1.0% of reading
Response Time (T₉₀)1.5 s
Operating Temperature (Gas Path)Up to 200 °C (optional to 230 °C)
Sample Flow Rate0.8–1.0 L/min
Power Supply115–230 VAC, 48–63 Hz, 120–150 W
Dimensions420 × 470 × 310 mm
Weight16 kg
Fuel GasH₂ (Grade 5, hydrocarbon residual <0.5 ppm, 3 bar) or H₂/He mixture
Zero GasBuilt-in catalytic hydrocarbon scrubber or carbon filter
Analog OutputsTwo user-configurable 0/4–20 mA
Digital OutputsThree programmable relay contacts (250 V AC, 1 A)
Data StorageInternal XML logging, USB export to Excel-compatible format
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMCQ
OriginItaly
ModelGB 100
Flow Range (per channel)0–500 mL/min (standard), 0–200 mL/min (optional)
Accuracy±1.0% of setpoint (5–100% FS), ±0.2% of full scale (<5% FS)
Repeatability±0.1% of reading
Response Time50 ms per channel
Total Mixed FlowUp to 1.5 L/min
Channels3 inlet, 1 outlet
Operating Pressure≤25 psi
Power Supply16–36 VDC, min. 1.5 A
Operating Temperature0–50 °C
Gas CompatibilityN₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, C₃H₈, C₄H₁₀ (H₂ not supported)
CertificationsCE, TÜV, cTÜVus
InterfaceUSB PC connection, LED front-panel display
SoftwareDedicated gas mixing control software (Windows-based), no third-party API support for GB100 variant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesta
OriginGermany
ModeliFiD mobile
Detection PrincipleFlame Ionization Detection (FID)
Instrument TypePortable
Measurement Range0–30,000 ppmC₁
Response Time1 s (T₉₀)
Repeatability±1% of full scale
Zero Drift±1% FS over 24 h
Detector Temperature190 °C
Hot Filter Temperature300 °C
Warm-up Time15 min
Power Supply100–240 V AC, 50–60 Hz, 350 W
Operating Temperature0–45 °C
Enclosure RatingIP40
Dimensions178 × 370 × 420 mm
Weight12 kg
Fuel GasH₂ (Grade 5) or He/H₂ mixture
Burner AirBuilt-in pump, flow-controlled
Calibration GasesC₃H₈, CH₄, C₂H₆
Zero GasN₂ or synthetic air
Sample Flow ControlInternal pressure compensation (−150 to +500 hPa)
Analog Output0–20 mA / 0–10 V
Digital InterfaceEthernet, RS232
Data StorageUSB flash drive
Remote AccessVNC-compatible
OptionalIntegrated zero-air generator, thermal desorption cleaning cycle
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginFrance
ModelEMIR-PAS
Instrument TypeTunable Quantum Cascade Laser-Based Mid-IR Photoacoustic Spectrometer
Detection PrincipleLaser Photoacoustic Spectroscopy (LPAS)
Key GasesH₂O, NO, NO₂, CO, CO₂, NH₃, CH₄, N₂O, SF₆
Detection LimitSub-ppm (gas-dependent)
Accuracy<1% of reading or LOD
Repeatability<1% of reading or LOD
Response Time (T90)Typically <5 s
Measurement FrequencyUp to 10 Hz
Sample Flow Rate<80 mL/min
Cell Volume1 mL
Operating Pressure0.5–2 bar.a (requires integrated pressure sensor)
Power Supply24 V DC, ~10 W
CommunicationRS485, Modbus RTU
Dimensions115 × 170 × 108 mm
Weight<2 kg
Environmental Operating Range10–30 °C, 0–95% RH (non-condensing)
ComplianceDesigned for industrial integration in EPA-, ISO-, and IEC-compliant monitoring systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelUYI-U700
Linear Error≤±1% FS
Span Drift≤±1% FS
Response Time≤20 s (field-dependent)
Measurement PrincipleTDLAS
Measurable GasesCH₄, CO₂, CO, NH₃, H₂S, HF
Concentration Rangeppm to % vol
Accuracy≤±1% FS
Calibration Interval≤2 times/year
Power Supply220 VAC
Output Signals4–20 mA or RS485
Operating Temperature−20 °C to +60 °C
Sample Flow Rate20–30 L/h
Enclosure Dimensions500 × 500 × 200 mm (typical)
ComplianceDesigned for industrial process environments requiring continuous emission monitoring and safety-critical gas detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelUE242B
Price RangeUSD 4,200–7,000 (FOB)
RepeatabilitynC6, nC4+nC5 channels < 0.1 mol%
HHV, LHV & Wobbe Index (WI)< 0.3% of reading or < 0.15 MJ/m³ (whichever is greater)
Specific Gravity< 0.06% of reading
Explosion ProtectionEx d IIC T6 Gb
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMCQ
OriginItaly
ModelGB6000
Input Channels6
Output Channels1
Flow Range per Channel0–5000 mL/min
Dilution Ratio1:1 to 1:1000
Gas CompatibilityN₂, O₂, CO₂, CH₄, Air, NO, CO, Ar, C₂H₄, C₂H₆, SF₆, C₃H₈, C₄H₁₀, H₂, He, DME (C₂H₆O), N₂O, SO₂, and other custom gases upon consultation
Third-Party Software IntegrationYes
Certification StatusCE-marked, compliant with ISO/IEC 17025 traceability requirements for gas standard generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandONUEE
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelUE2030
PricingAvailable Upon Request
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Application SectorEnvironmental Monitoring
Detection GasesCH₄ (0–100 ppm), CO₂ (0–2000 ppm), CO, N₂O, H₂O
AccuracyCH₄ ±0.3 ppm
Response Time<1 s
Zero NoiseCH₄ 0.15 ppm
Precision at 80% Full ScaleCH₄ 0.3 ppm
Measurement Uncertainty±3% of reading
LODCH₄ 10 ppb
Output InterfaceRS485
Power SupplyDC 12 V
Operating Temperature−30 °C to +60 °C
Relative Humidity<95% RH (at +25 °C)
Ambient Pressure Range80–116 kPa
Dimensions25 cm × 53 cm × 54 cm
Net Weight5 kg
Enclosure2U Rack-Mountable Chassis
Internal SamplingIntegrated diaphragm pump with particulate filter and moisture trap
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0