Spectroscopy Instruments
Filter
Showing 2461–2490 of 2535 results
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Elements | Holographic Grating + Bandpass/Notch Filters |
| Excitation Sources | CW Laser Diode, Pulsed Laser (ns–ps range), Electrical Probe Station (for e-pumped lasing) |
| Detection Mode | Confocal Micro-Spectroscopy with Back-Illuminated CCD or EMCCD |
| Spatial Resolution | Diffraction-Limited (~300 nm lateral at 532 nm) |
| Spectral Range | 200–1100 nm (configurable) |
| Temporal Resolution | Down to <100 ps (with TCSPC option) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MiniPL 5.0 eV |
| Excitation Wavelengths | 224 nm (5.5 eV) or 248.6 nm (5.0 eV) |
| Spectral Range (Standard) | 190–650 nm |
| Spectral Range (Optional) | 190–850 nm |
| Resolution (Standard) | 0.2 nm @ 1200 g/mm grating |
| Resolution (Optional) | 0.07 nm @ 3600 g/mm grating |
| Detector | High-sensitivity PMT |
| Signal Processing | Built-in boxcar averager for pulsed signal integration |
| Sample Stage | Manual XYZ adjustment, max. 50 mm diameter |
| Optional | Motorized XY scanning stage for PL mapping |
| Dimensions | 15 × 18 × 36 cm |
| Weight | < 8 kg |
| Software Platform | LabVIEW-based control & spectral analysis suite |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MiRass DUV |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–5,000 cm⁻¹ (325 nm excitation) |
| Spectral Resolution | ≤1 cm⁻¹ (@585.25 nm) |
| Spatial Resolution | ≤1 µm (diffraction-limited, with 100× objective) |
| Minimum Detectable Wavenumber | 15 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Excitation Lasers (Standard) | 325 nm (≥30 mW, TEM₀₀), 532 nm (≥100 mW, TEM₀₀) |
| Excitation Lasers (Optional) | 244 nm, 266 nm, narrow-linewidth tunable UV–NIR laser |
| Detector | Deep-cooled back-illuminated scientific CCD |
| Detector Quantum Efficiency | >40% @ 250–400 nm |
| Pixel Array | 2048 × 512 |
| Pixel Size | 13.5 × 13.5 µm |
| Spectral Response Range | 200–1000 nm (UV-enhanced) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Excitation Sources | 808 nm, 980 nm, 1064 nm, 1550 nm, 1940 nm CW lasers |
| Detection Range | 1–5.5 μm (InSb), 2–12 μm (MCT), 800–2600 nm (TE-InGaAs), 300–1700 nm (LN-PMT) |
| Spectral Resolution | ≤0.1 nm (with 320 mm Czerny-Turner monochromator & 68 mm × 68 mm gratings) |
| Fluorescence Lifetime Range | μs to seconds (with TCSPC or oscilloscope synchronization) |
| Optical Platform | Damped vibration-isolation table (1800 × 1200 × 800 mm) |
| Brand | ZOLIX |
|---|---|
| Model | Lifetime Aging Test System |
| Type | Integrated Automated OLED Degradation Monitoring Platform |
| Origin | Beijing, China |
| Power Supply | 5 kW / 380 V AC |
| Temperature Range Options | −40 °C to 150 °C, −20 °C to 150 °C, or 0 °C to 150 °C |
| Heating Rate | 2–4 °C/min (nonlinear, no-load) |
| Cooling Rate | 0.7–1.0 °C/min (nonlinear, no-load) |
| Temp. Resolution | ±0.01 °C |
| Humidity Range | 20–98% RH (within 25–85 °C) |
| Humidity Resolution | ±0.1% RH |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.0% RH |
| Humidity Deviation | ±3% RH (at >75% RH) |
| Channel Configurations | Up to 128 independent current/voltage monitoring channels |
| Control Interface | Touchscreen HMI with programmable temperature/humidity profiles |
| Compliance | Designed for GLP-aligned operational traceability and ASTM D7602-22 (Standard Practice for Accelerated Aging of Organic Light-Emitting Diode Devices) support |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-fs-TA |
| Instrument Type | Transient Absorption Spectrometer |
| Temporal Resolution | 1.5 × Laser Pulse Width |
| Sensitivity | 0.1 ΔmOD (broadband), 0.01 ΔmOD (single-wavelength) |
| Pump Wavelength Ranges | 240–480 nm, 475–1160 nm, 1160–1600 nm, 1600–2600 nm |
| Probe Wavelength Ranges | 300–700 nm |
| Detection Time Window | 4 ns / 8 ns |
| Laser Sources | 800 ± 10 nm, 1030 ± 3 nm |
| Sample Formats | Liquid, Powder, Thin Film |
| Measurement Modes | Transmission, Reflection, Back-Excitation |
| Software Features | Probe Stability Monitoring, Real-Time Spectral Preview, Spectral Calibration, Smoothing, Global & Target Data Fitting |
| Optional Modules | Micro-area Spectroscopy, Wide-field Transient Absorption Imaging, TCSPC (2 ps min. time step, 100 ps min. lifetime range, 0.08 nm spectral resolution), Femtosecond Kerr-Gated Time-Resolved Fluorescence (400–900 nm, 50 fs pulse width, 4 ns window) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-Imager |
| Price Range | USD 70,000 – 140,000 |
| Operating Principle | Push-broom scanning |
| Imaging Method | Filter-based |
| Deployment Mode | Ground-based and airborne compatible |
| Spectral Resolution | 2.8 nm @ 30 µm slit, 2 nm @ 18 µm slit |
| Detector Types | CCD (1392×1040), sCMOS (2048×2048), EMCCD (512×512), InGaAs (320×256 / 640×512) |
| Spectral Ranges | 400–1000 nm (Vis-NIR), 900–1700 nm (NIR) |
| Numerical Aperture | f/2.4 (Vis-NIR), f/2.0 (NIR) |
| Slit Dimensions | 30 µm × 14.2 mm (standard), 18 µm × 14.2 mm (optional) |
| Data Depth | 12-bit / 16-bit |
| Interface | USB 2.0 / USB 3.0 |
| Lens Mount | C-mount |
| Cooling | Air-cooled to −0 °C (CCD/sCMOS), TE-cooled to −80 °C (EMCCD), TE3-cooled (InGaAs) |
| Software | Proprietary acquisition & analysis suite with ENVI/Evince/SpecSight export compatibility |
| Optional Onboard Processing | Intel Core i7, 16 GB RAM, 256 GB SSD |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Omni-iSpecT Fiber-Coupled Raman Spectroscopy System |
| Laser Options | 532 nm (100 mW), 785 nm (350 mW) |
| Raman Shift Range | 200–4000 cm⁻¹ (532 nm) |
| Spectral Resolution | <10 cm⁻¹ (typical, @50 µm slit) |
| CCD Detector | Back-illuminated deep-depletion CCD, 2000 × 256 pixels, 15 µm pixel size, -60 °C cooling, read noise <5 e⁻/pixel |
| Probe Working Distance | 3 mm / 7 mm (standard), customizable |
| Operating Temperature | 0–325 °C (customizable up to 400 °C) |
| Max Pressure Rating | 6000 psi |
| Probe Material | Hard-anodized aluminum + 316 stainless steel |
| Sealing | Perfluoroelastomer (FFKM) O-rings standard |
| Fiber Core | 100/100 µm (standard), SMA/MPO/10 mm cylindrical interface |
| Optical Throughput | F/1.8 (532 nm), F/2.3 (785 nm) |
| Grating | 1800 l/mm VPH (532 nm), 1200 l/mm VPH (785 nm) |
| Weight | 5.0 kg (spectrometer), 5.8 kg (full system) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-LIBS Integrated LIBS System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Omni-LIBS Series |
| Spectrometer Architecture | Czerny-Turner (C-T) |
| Focal Length Options | 200 mm / 320 mm / 500 mm / 750 mm |
| Grating Options | up to 1200 grooves/mm |
| Spectral Resolution | down to 0.03 nm (at 750 mm focal length with 1200 g/mm grating) |
| Detection Compatibility | ICCD, sCMOS, CCD, PMT |
| Input Interface | SMA905 fiber-coupled |
| Output Interface | Standard C-mount or F-mount for detector integration |
| Laser Compatibility | Nanosecond (532 nm / 1064 nm) and femtosecond pulsed lasers |
| Timing Control | External TTL synchronization support for laser–detector delay (ns–µs range) |
| Software Platform | ZOLIX SpectraMaster™ v4.2 with spectral calibration, peak identification (NIST database), and semi-quantitative analysis modules |
| Compliance | ASTM E2926-21 (Standard Practice for LIBS Analysis), ISO/IEC 17025:2017 compatible workflow architecture |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Laser Flash Photolysis Instrument |
| Spectral Range | Application-Dependent (UV–NIR, configurable via OPA) |
| Spectral Resolution | <5 nm (typical, OPA-tunable) |
| Temporal Resolution | 500 fs (with 100-fs pump pulse) |
| Spatial Resolution | 500 nm |
| Carrier Localization Accuracy | 30 nm |
| Optical Delay Range | 0–4 ns / 0–8 ns (motorized precision delay line) |
| Detection | sCMOS camera with >95% quantum efficiency at 500–900 nm |
| Microscopy Platform | Inverted microscope with open-top design for cryostat, electrical biasing, magnetic field, and probe station integration |
| Operating Modes | Point Pump / Wide-Field Probe |
| Sample Illumination | Reflectance & Scattering Configurations Supported |
| Compliance | GLP-compliant data acquisition architecture |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-V200 |
| Price | USD 42,000 (FOB Beijing) |
| Spectral Resolution | 0.1 nm |
| Wavelength Range | 80–300 nm |
| Optical Design | Aberration-Corrected Imaging S-N System |
| Incidence Angle | 32° |
| Focal Length | 200 mm |
| Wavelength Accuracy | ±0.1 nm (@1200 g/mm grating) |
| Wavelength Repeatability | ±0.1 nm (@1200 g/mm grating) |
| Operating Vacuum | ≤1×10⁻⁶ Torr |
| Grating Groove Density | 1200 lines/mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Omni-λ |
| Pricing | Upon Request |
| Focal Length Options | 150 mm, 300 mm, 500 mm, 750 mm |
| Optical Design | Czerny–Turner (C-T) |
| Grating Mount | Dual-grating turret (Omni-λ150/300), Triple-grating turret (Omni-λ500/750) |
| Grating Size | 68 × 68 mm (standard for ≥300 mm models) |
| Wavelength Range | UV-VIS-NIR (190–2500 nm, dependent on grating and detector selection) |
| Resolution (with 1200 g/mm grating) | 0.4 nm (Omni-λ150) to 0.03 nm (Omni-λ750) |
| Wavelength Accuracy | ±0.25 nm (Omni-λ150) to ±0.2 nm (Omni-λ300+) |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Scan Step | 0.005 nm |
| Entrance/Exit Configuration | Motorized dual-input/dual-output port selection |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Slit Options | Manual (0.01–3 mm width, 2/4/10/14 mm height) or motorized automatic slit |
| Optional Accessories | Motorized filter wheel, electronic shutter, CCD array or single-point detector integration |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ |
| Instrument Type | Laboratory Benchtop Spectrometer |
| Operating Principle | Grating Scanning Monochromator |
| Wavelength Range | 300–2600 nm |
| Scan Speed | 400 nm/min |
| Data Sampling Interval | 0.1 nm |
| Sample Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | ZolixScanBasic V4 |
| Focal Length Options | 150 mm / 300 mm |
| Optical Design | Czerny-Turner |
| Grating Mount | Dual- or Triple-Grating Turret |
| Grating Sizes | 32×32 mm / 68×68 mm |
| IR-Optimized Optics | Gold-Coated Mirrors for >1 µm |
| Entrance/Exit Port Configuration | Motorized Dual Input/Dual Output |
| Slit Width Adjustment | 0.01–3 mm (manual), optional motorized |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Resolution (1200 g/mm) | 0.4 nm (Omni-λ150) / 0.1 nm (Omni-λ300) |
| Wavelength Accuracy | ±0.25 nm (Omni-λ150) / ±0.2 nm (Omni-λ300) |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Step Size | 0.01 nm (Omni-λ150) / 0.005 nm (Omni-λ300) |
| Focal Plane Dimensions | 25×10 mm (Omni-λ150) / 27×14 mm (Omni-λ300) |
| Optical Axis Height | 137.5 mm |
| Interface | Standard USB 2.0 (RS-232 optional) |
| Weight | 5 kg (Omni-λ150) / 15 kg (Omni-λ300) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ Series |
| Application Systems | Transmission & Reflection Spectroscopy |
| Number of Gratings | Dual-grating turret |
| Spectral Resolution | 0.4 nm (FWHM, @1200 g/mm grating, 10 µm slit) |
| Linear Dispersion | 3.68 nm/mm |
| Wavelength Range | 400–1000 nm (standard configuration) |
| F-number | f/4.2 |
| Wavelength Accuracy | ±0.25 nm |
| Stray Light Level | ≤0.1% (typical), down to 1×10⁻⁵ with optimized gratings and baffling |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model Series | Omni-λ Imaging Monochromator Series |
| Pricing | Available Upon Request |
| Focal Length Options | 180 mm, 320 mm, 500 mm, 750 mm |
| Optical Design | Czerny-Turner with Aspheric Image Correction |
| Grating Mount | Dual- or Triple-Grating Turret |
| Grating Sizes | 40×40 mm, 68×68 mm (or 68×84 mm) |
| Wavelength Range | UV–VIS–NIR (190–2500 nm), Optimized for IR (>1 µm) with Gold-Coated Optics |
| Stray Light Suppression | ≤1×10⁻⁵ |
| Control Interface | USB 2.0 (standard), RS-232 (optional) |
| Drive System | DSP-Based Motorized Control |
| Slit Options | Manual (0.01–3 mm width, 2/4/10/14 mm height) or Motorized Adjustable Slit |
| Detector Compatibility | PMT, CCD (26 µm pixel pitch), InGaAs, MCT |
| Entrance/Exit Port Configuration | Single or Dual Input/Output (software-selectable) |
| Typical Resolution (1200 g/mm grating) | 0.028–0.35 nm (CCD/PMT dependent) |
| Wavelength Accuracy | ±0.1–±0.2 nm |
| Wavelength Repeatability | ±0.01–±0.1 nm |
| Scan Step Size | 0.0025–0.01 nm |
| Focal Plane Dimensions | 30 mm (w) × 10–14 mm (h) |
| Optical Axis Height | 146.5 mm |
| Relative Aperture | f/4 to f/9.7 |
| Brand | ZOLIX |
|---|---|
| Model | Omni-λ Series |
| Type | Triple-stage grating monochromator |
| Focal Length | 500 mm per stage |
| Configuration | Two-stage subtractive dispersion + one-stage additive dispersion |
| Spectral Range | 200–800 nm |
| Wavenumber Range (at 325 nm excitation) | 50–18,000 cm⁻¹ |
| Resolution | 3 cm⁻¹ |
| Repeatability | ±5 cm⁻¹ |
| Imaging Range (single acquisition) | 700 cm⁻¹ |
| Grating Mounts | Three gratings per stage (9 total) |
| Grating Options | 1800, 1200, 600, 3600, and 2400 grooves/mm |
| Blaze Wavelengths | 250 nm, 300 nm, 500 nm |
| Grating Size | 68 × 68 mm |
| Reflectivity (peak) | ~70% across UV–Vis |
| Input/Output | Stage 1 & 2 — side-entry dual-output |
| Detector Compatibility | CCD array detectors, PMT, and other single-channel photodetectors |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Beijing Zolix Instruments Co., Ltd.) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ180D |
| Application System | Universal |
| Spectral Resolution | 0.25 nm |
| Linear Dispersion | 3.7 nm/mm |
| Wavelength Accuracy | ±0.2 nm |
| F-number | F/3.9 |
| Stray Light Level | <1×10⁻⁹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic |
| Model | Omni-λ180D |
| Price Range | USD 1,400 – 7,000 |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.25 nm (at 1200 g/mm grating) |
| Dispersion | 3.7 nm/mm (linear dispersion, at 1200 g/mm grating) |
| Wavelength Range | 190–1100 nm (dependent on grating selection) |
| F-number | F/3.9 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light Level | <1×10⁻⁹ |
| Brand | ZOLIX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | Omni-λ2002i |
| Application Systems | Transmission/Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Stray Light Level | 5 × 10⁻⁵ |
| Focal Length | 200 mm |
| f-number | f/3.5 |
| Optical Design | Czerny–Turner with Toroidal Imaging Correction |
| Entrance/Exit | Side-mounted entrance, side-mounted CCD exit |
| Grating Size | 50 × 50 mm |
| Slit Width Range | 0.01–3 mm (manual, motorized optional) |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| 焦 Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Wavelength Accuracy | ±0.1 nm (@1200 g/mm, 435.83 nm) |
| Wavelength Repeatability | 0.05 nm (@1200 g/mm, 435.83 nm) |
| Minimum Scan Step | 0.005 nm (@2400 g/mm) |
| Spectral Resolution (PMT) | 0.08 nm (@2400 g/mm, 435.83 nm) |
| Spectral Resolution (15-µm-pixel CCD) | 0.106 nm (@2400 g/mm, 435.83 nm) |
| CCD Single-Capture Spectral Range | 42 nm (@2400 g/mm, 30-mm CCD) |
| Mechanical Scan Range | 0–19,200 nm (dependent on grating) |
| Stray Light Suppression Ratio | 5 × 10⁻⁵ |
| Power Requirement | 100 W peak @ 24 V DC |
| Standard Interface | USB 2.0 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | Omni-λ200i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Number of Gratings | Triple-grating turret mount |
| Spectral Resolution (CCD, 26 µm pixel) | 0.28 nm |
| Linear Dispersion | 3.6 nm/mm |
| Wavelength Range | 400–1000 nm |
| F-number | f/3.5 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light Level | 1×10⁻⁵ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Laboratory-grade Infrared Spectral Analyzer |
| Model | Omni-λ300i |
| Wavenumber Range | 4000–25000 cm⁻¹ |
| Spectral Resolution | 0.08 nm (with 1200 g/mm grating) |
| Signal-to-Noise Ratio | 8000:1 |
| Stray Light Level | ≤1×10⁻⁵ |
| Focal Length | 320 mm |
| f-number | f/4.2 |
| Optical Design | Czerny-Turner with Aspheric Image Correction |
| Grating Size | 68×68 mm |
| Grating Tower | Triple-grating turret |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Slit Width Adjustment | 0.01–3 mm (manual or motorized option) |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Wavelength Accuracy | ±0.15 nm |
| Wavelength Repeatability | ±0.08 nm |
| Minimum Scan Step | 0.005 nm |
| Dispersion | 2.3 nm/mm (at 435.8 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Omni-λ300i |
| Application System | Universal |
| Grating Capacity | Triple-Grating Turret |
| Focal Length | 320 mm |
| Optical Design | Czerny-Turner with Toroidal Imaging Correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Options | Side or Dual Input/Output Configurable |
| Slit | Manual (0.01–3 mm width, 2/4/14 mm height), Motorized Slit Optional |
| Detector Interface | Dual CCD Output Standard |
| Control Interface | USB 2.0 (RS-232 Optional) |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.04–1.28 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.069–3.05 nm |
| Linear Dispersion (@435.83 nm) | 0.91–40.43 nm/mm |
| Scan Range | 0–19,200 nm (grating-dependent) |
| Scan Step | 0.0025–0.08 nm |
| F/# | f/4.2 |
| Image Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Dimensions | 420 × 295 × 232 mm |
| Weight | 16 kg |
| Max Power Consumption | 100 W @ 24 V DC |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Omni-λ500i |
| Application System | Universal |
| Number of Gratings | Triple-grating turret |
| Focal Length | 500 mm |
| Optical Design | Czerny-Turner with toroidal imaging correction |
| Stray Light Level | 1×10⁻⁵ |
| Grating Size | 68×68 mm (or 68×84 mm optional) |
| Entrance/Exit Configuration | Side entrance, dual出口 (CCD + slit), configurable multi-port options |
| Slit Width Range | 0.01–3 mm (manual standard |
| Slit Height Options | 2 mm, 4 mm, or 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Weight | 22 kg |
| Power Consumption | ≤100 W @ 24 V DC |
| Communication Interface | USB 2.0 (standard), RS-232 (optional) |
| Control Architecture | DSP-based motorized turret & port selection |
| Wavelength Accuracy | ±0.1 nm to ±3.2 nm (dependent on grating) |
| Wavelength Repeatability | 0.015–0.8 nm (grating-dependent) |
| Spectral Resolution (with point detector) | 0.03–0.8 nm |
| Spectral Resolution (with 15 µm-pixel CCD) | 0.045–1.97 nm |
| Linear Dispersion (@435.83 nm) | 0.6–26.05 nm/mm |
| Mechanical Scan Range | 0–19,200 nm (grating-dependent) |
| Minimum Step Size | 0.0025–0.08 nm (grating-dependent) |
| CCD Single-Capture Spectral Range (@30 mm sensor) | 18–781.5 nm (grating-dependent) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ750i |
| Application System | Universal |
| Number of Gratings | Triple-grating turret |
| F/# | F/9.7 |
| Focal Length | 750 mm |
| Optical Design | Czerny-Turner with toroidal imaging correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Grating Size | 68×68 mm (optional 68×84 mm) |
| Slit Width Range | 0.01–3 mm (manual standard |
| Slit Height Options | 2 mm, 4 mm, or 14 mm |
| Entrance/Exit Configuration | Side entrance |
| Wavelength Accuracy | ±0.1–±3.2 nm (dependent on grating) |
| Wavelength Reproducibility | 0.015–0.8 nm |
| Spectral Resolution (PMT) | 0.02–0.36 nm |
| Spectral Resolution (15 µm-pixel CCD) | 0.033–1.329 nm |
| Linear Dispersion (@435.83 nm) | 0.43–17.58 nm/mm |
| Mechanical Scan Range | 0–19,200 nm (grating-dependent) |
| Minimum Step Size | 0.0025 nm |
| CCD Single-Capture Span (@30 mm sensor) | 12.9–527.4 nm |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Control Architecture | Embedded DSP-based motion and port logic |
| Coating Options | Standard Al+MgF₂ (UV-VIS), gold (IR >1 µm), enhanced UV (e.g., MgF₂ overcoat) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-λ750S |
| Application System | Universal |
| Grating Capacity | Triple-grating turret |
| Focal Length | 750 mm |
| Optical Design | Czerny-Turner with toroidal image correction |
| Stray Light Rejection | 1×10⁻⁵ |
| Entrance/Exit Options | Dual entrance, dual exit |
| Standard Interface | USB 2.0 |
| Grating Size | 68×68 mm (optional 68×84 mm) |
| Slit Width Range | 0.01–3 mm (manual), motorized slit optional |
| Slit Height Options | 2 mm / 4 mm / 14 mm |
| Focal Plane Dimensions | 30 mm (W) × 14 mm (H) |
| Optical Axis Height | 146 mm |
| Relative Aperture | f/9.7 |
| Minimum Scan Step | 0.0025 nm (with 2400 g/mm grating) |
| Wavelength Accuracy | ±0.1 nm (at 435.83 nm, 2400 g/mm) |
| Wavelength Repeatability | ±0.015 nm (at 435.83 nm, 2400 g/mm) |
| CCD Spectral Resolution (15 µm pixel) | 0.026 nm (2400 g/mm) |
| Single-shot CCD Spectral Coverage | 12.9 nm (30 mm CCD, 2400 g/mm, 435.83 nm center) |
| Infrared Optimization | Gold-coated optics for >1 µm operation |
| UV Optimization | Optional UV-enhanced coatings |
| Power Supply | 24 V DC, peak 100 W |
| Dimensions (L×W×H) | 800 × 338 × 230 mm |
| Weight | 40 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Omni-λXi |
| Application Systems | Transmission/Reflection Spectroscopy |
| Grating Configuration | Triple-Grating Turret |
| Spectral Resolution | 0.35 nm (@1200 g/mm) |
| Linear Dispersion | 3.68 nm/mm |
| Wavelength Range | 400–1000 nm |
| F-number | f/1 |
| Wavelength Accuracy | ±0.25 nm (@1200 g/mm) |
| Stray Light | ≤0.1% (1×10⁻³) |
| Brand | ZOLIX |
|---|---|
| Model | Omni-λxxxD Series |
| Type | Dual-stage grating monochromator |
| Focal Length Options | 300 mm, 500 mm, or 750 mm per stage |
| Configuration Modes | Additive dispersion (high-resolution) and subtractive dispersion (low-stray-light) |
| Grating | 1200 g/mm standard |
| Slit Width | 0.01–3 mm (manual), motorized slit optional |
| Slit Height | 2 / 4 / 10 / 14 mm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Relative Aperture | F/3.9 (300 mm), F/6.5 (500 mm), F/9.7 (750 mm) |
| Linear Dispersion (1200 g/mm) | 1.35 / 2.7 nm/mm (Omni-λ300D, additive/subtractive) |
| Resolution (1200 g/mm) | 0.05 / 0.1 nm (Omni-λ300D, additive/subtractive) |
| Interface | USB 2.0 standard, RS-232 optional |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OmniEvo |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OmniFluo |
| Price Range | USD 28,000–42,500 (FOB) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm |
| Spectral Resolution | ±0.05 nm |
| Sensitivity | >3000:1 (Water Raman S/N ≥1000:1) |
| Wavelength Accuracy | ±0.15 nm |
| Spectral Range | 200–2500 nm |
| Excitation Sources | 150 W / 500 W Xenon Arc Lamp with Monochromator (Bandwidth 0.1–30 nm) |
| Optional Lasers | 266, 325, 375, 405, 442, 532, 785, 1064 nm |
| Detector Options | Cooled CCD (2000×256, 200–1000 nm), Cooled InGaAs Array (512×1, 800–2200 nm), PMT (200–870 nm), Cooled Single-Element InGaAs (800–2500 nm) |
| Signal Processing | Photon Counting or Lock-in Amplification |
| Optional Modules | Quantum Yield Measurement, Electroluminescence (EL), Cryogenic Sample Stage (≤10 K) |
| Emission Spectrum Correction | Built-in Absolute Intensity Calibration Function |