Spectroscopy Instruments
Filter
Showing 31–60 of 2603 results
| Brand | AECC (Aviation Engine Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Model | LPG-2000 |
| Light Source | DC-pulsed hollow cathode discharge (low-pressure) |
| Optical Chamber | Evacuated vacuum chamber |
| Wavelength Range | 170–430 nm |
| Grating | Holographic concave grating, focal length 750 mm, 2400 grooves/mm |
| Spectral Resolution | < 0.024 nm |
| Detector | Hamamatsu high-sensitivity, low-noise photomultiplier tube (PMT) |
| Elemental Coverage | Ag, As, Au, B, Ba, Be, Bi, Ca, Cd, Ce, Cu, Ga, Ge, Hg, In, La, Mg, Mn, P, Pb, Pd, Pt, Rh, Ru, Sb, Se, Si, Sn, Sr, Te, Tl, Y, Zn, Zr (including sub-190 nm lines for B and P) |
| Detection Limits | 1×10⁻⁵% to 1×10⁻⁷% (e.g., Bi ≤ 0.00001%, As ≤ 0.0005%, P ≤ 0.001%, B ≤ 0.001%) |
| Precision | RSD < 20% for 10 replicate excitations on homogeneous samples |
| Temperature Control | Thermostabilized optical chamber, ±0.1 °C stability |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AFX1000-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based & UAV-mounted |
| Spectral Range | 400–1000 nm (HSI) + 8–14 µm (LWIR) |
| Thermal Imaging Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Frame Acquisition Rate | ≥300 Hz (full spectral cube acquisition) |
| Total Field of View (TFOV) | 30.5° |
| Instantaneous Field of View (IFOV) | 2.7 mrad |
| RGB Camera | 26 MP synchronized capture |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFX1700-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and UAV-mounted |
| Spectral Range | 900–1700 nm (VNIR/SWIR HSI) + 8–14 µm (LWIR thermal) |
| Thermal Spatial Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Maximum Data Acquisition Rate | ≥500 Hz across full spectral bands |
| Total Field of View (TFOV) | 35.5° |
| Instantaneous Field of View (IFOV) | 3.5 mrad |
| RGB Camera Resolution | 26 MP |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Hyper-Cam |
| Pricing | Available Upon Request |
| Operating Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Imaging Architecture | Dispersive (Grating-Based) |
| Deployment Mode | Ground-Based & Airborne Compatible |
| Spectral Range | 7.7–12.5 µm (MWIR) |
| Spectral Resolution | Up to 0.25 cm⁻¹ |
| Spatial Resolution (IFOV) | 0.45 mrad (typical, lens-dependent) |
| Detector Format | 320 × 256 HgCdTe FPA |
| Field of View (TFOV) | 6.4° × 5.1° |
| Frame Rate | Up to 60 Hz (full-frame, binning-dependent) |
| Calibration | Onboard Blackbody + Ambient Reference |
| Compliance | ISO/IEC 17025-aligned calibration traceability, GLP-compliant data acquisition workflow |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RedEdge-P |
| Pricing | Available Upon Request |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | X20P-IR |
| Spectral Range | 350–1000 nm (VNIR) + 7.5–13.5 µm (LWIR) |
| Spectral Resolution | 164 bands (VNIR), 640 × 512 pixels (LWIR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Field of View (TFOV) | 35° |
| Instantaneous Field of View (IFOV) | < 1.5 mrad (typ.) |
| Imaging Modality | Snapshot-based dispersive hyperspectral imaging with concurrent uncooled microbolometer LWIR imaging |
| Platform Compatibility | Ground-based tripod mounting and UAV-integrated operation (multirotor & fixed-wing) |
| Integrated Stabilization | Brushless gimbal with SkyPort digital interface |
| Onboard Storage | Embedded solid-state storage |
| Data Synchronization | Hardware-triggered, frame-locked VNIR/LWIR acquisition |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LIR |
| Spectral Range | 350–1000 nm (VIS-NIR) + 905 nm (LiDAR) + 7.5–13.5 µm (MWIR/LWIR) |
| Spectral Resolution | ≥2 cubes/s (1886 × 1886 pixels per cube) |
| Spatial Resolution (IFOV) | ≤0.008° |
| Field of View (TFOV) | 0.008° |
| Frame Rate | ≥2 hyperspectral cubes per second |
| Image Format | 1886 × 1886 pixels per spectral cube |
| Thermal Imaging | 640 × 512 uncooled microbolometer, radiometrically calibrated |
| LiDAR Range | 450 m (@80% reflectivity) |
| Platform Compatibility | UAV-mounted (ground & airborne operation) |
| Onboard Systems | Integrated IMU, real-time georeferencing engine, solid-state storage, embedded control unit |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LV |
| Spectral Range | 350–1000 nm (hyperspectral) + 905 nm (LiDAR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Spectral Channels | 164 (expandable) |
| LiDAR Range | 450 m (@ 80% reflectivity) |
| LiDAR Accuracy | ±2 cm (1σ @ 20 m) |
| FOV | 0.008° |
| IFOV | 2 cubes/s, 1886 × 1886 pixels/cube |
| IMU Accuracy | Heading ±0.038°, Attitude ±0.008° |
| Data Interface | 2× GigE, 2× USB, HDMI |
| Onboard Storage | 256 GB SSD + 8 GB RAM |
| Sensor Configuration | 20 MP hyperspectral CMOS + 3.5 MP panchromatic sensor + solid-state 905 nm LiDAR |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 240FS AA |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Sensitivity | Mark 7 Atomization System — Cu 5 mg/L typically yields >0.9 Abs |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 240Z AA |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Spectral Resolution | ≤0.2 nm |
| Repeatability (RSD) | <2% |
| Detection Limit (Cd) | ≤0.006 µg/L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 280FS AA |
| Instrument Type | Flame AAS |
| Monochromator Type | Fixed-grating with high-resolution etched grating |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp (D₂) |
| Lamp Capacity | 8-lamp turret with automatic selection |
| Atomization System | Mark 7 Flame Burner Assembly |
| Sensitivity | >0.9 Abs for 5 mg/L Cu |
| Sample Volume per Analysis | 10 mL |
| Multi-element Throughput | Up to 10 elements per sample in <2 minutes |
| Calibration Automation | SIPS 10/20 Integrated Sample Introduction and Dilution System |
| Software Platform | SpectrAA Method Development Suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 280Z GFAA |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer |
| Optical System | Dual-Beam |
| Background Correction | Zeeman Effect |
| Atomizer | GTA 120 Zeeman Graphite Furnace |
| Light Source Configuration | Up to 8 Fixed-Lamp Positions |
| Detector | Photomultiplier Tube (PMT) |
| Calibration Method | Polynomial Interpolation |
| Software Platform | Windows-Based Worksheet Interface |
| Optional Hydride Generation Compatibility | VGA Adapter Available |
| Temperature Control Architecture | Isothermal Zone Graphite Furnace Design |
| Lamp Technology | UltrAA Hollow Cathode Lamps (AC-Modulated) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 4210 |
| Pricing | Available upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 4300 |
| Instrument Type | Handheld |
| Instrument Class | Fourier Transform Infrared (FTIR) |
| Spectral Range | 5,200–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ (standard) |
| Detector | DTGS with Diamond ATR option |
| Sampling Modes | Diamond-ATR, Ge-ATR, Specular Reflectance, Diffuse Reflectance, Grazing Angle, Retro-reflector |
| Dimensions | 35 cm (H) × 19 cm (D) |
| Weight | 2.2 kg |
| Power Supply | Hot-swappable Li-ion battery (4 h typical runtime) / 100–240 VAC, 50/60 Hz |
| Software Platform | MicroLab Mobile, MicroLab Expert, optional MicroLab Pharma (21 CFR Part 11 & EU Annex 11 compliant) |
| Sample Types | Solids, Pellets, Liquids, Pastes, Powders, Gels |
| Library Options | Preloaded application-specific spectral libraries (ATR, geological minerals), customizable library creation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 4500 |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Spectral Range | 4000–650 cm⁻¹ |
| Dimensions (W×H×D) | 29 cm × 19 cm × 22 cm |
| Weight | 6.8 kg |
| Power Supply | Internal rechargeable battery (up to 4 h operation) / 100–240 VAC, 50/60 Hz |
| Software | MicroLab FTIR and MicroLab Expert |
| Sample Types | Solids, pellets, liquids, pastes, powders, gels |
| Sampling Interfaces (Fixed Options) | Diamond ATR (1×, 3×, or 5× reflection), Multireflection ZnSe ATR, TumblIR, DialPath |
| Library Support | Application-specific spectral libraries pre-installed |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 5500 |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Spectral Range | 4,000 to 650 cm⁻¹ |
| Dimensions (W × D × H) | 20 cm × 20 cm × 11 cm |
| Weight | 3.6 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sampling Modules | Fixed Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath |
| Software Platform | MicroLab, MicroLab Expert, MicroLab Quant, MicroLab Pharma (optional) |
| Library Support | Pre-validated application-specific spectral libraries |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 5800 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | S (180.669 nm) < 5 µg/L |
| Precision (RSD) | ≤1.0% |
| Short-Term Stability (RSD) | ≤0.5% |
| Wavelength Range | 167–785 nm |
| Optical Resolution | ≤0.0065 nm (at As 188.980 nm) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5900 ICP-OES |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | S (180.669 nm) < 5 µg/L |
| Repeatability | ≤1.0% RSD |
| Short-Term Stability | RSD ≤0.5% |
| Wavelength Range | 167–785 nm |
| Optical Resolution | ≤0.0065 nm (at As 188.980 nm) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8453 |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤ 0.03% T |
| Automation Level | Automatic Wavelength Scanning |
| Instrument Classification | Imported High-Performance UV-Vis Spectrophotometer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AA DUO |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator Type | Custom High-Resolution Echelle Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Zeeman Effect |
| Linear Dynamic Range | Sub-ppt to Percent-Level Concentrations |
| Automation | Fully Integrated Dual-Atomizer Control via Agilent Workstation Software |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 3500 |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.1 – 5.0 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 4000 |
| Optical Design | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–900 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 0.01–5.00 nm (variable) |
| Photometric Range | 0–8.0 Abs |
| Light Sources | Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Maximum Scan Speed | 2000 nm/min |
| Sample Compartment Z-Height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 5000 |
| Optical Design | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Photometric Range | ±8.0 Abs |
| Scan Speed | UV-Vis up to 2000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Purge | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 60 UV-Vis |
| Instrument Architecture | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.5 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Cary 60 |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤ 0.03% T |
| Automation | Automatic Wavelength Scanning |
| Import Status | Imported Instrument |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 6000i |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 175–1800 nm (UV-Vis-NIR) |
| Automation Level | Motorized wavelength scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 8.0 Abs |
| Scan Speed | UV-Vis: 2000 nm/min |
| NIR | 8000 nm/min |
| Sample Compartment Z-height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Purge Capability | Dual nitrogen purge (sample chamber & monochromator) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Cary 630 |
| Instrument Type | Benchtop Fourier Transform Infrared Spectrometer |
| Wavenumber Range | KBr beam splitter: 7,000–350 cm⁻¹ |
| ZnSe beam splitter | 5,100–600 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Dimensions (W × D × H) | 14 × 26 × 16 cm |
| Weight | 3.5 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sample Compatibility | Solids, powders, pellets, liquids, gels, pastes, gases |
| Sampling Modules | Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath, Ge ATR, Mirror Reflection (10° and 45°), Transmission, Diffuse Reflectance, Gas Cell |
| Software | Agilent MicroLab, MicroLab Expert, MicroLab Pharma (optional, 21 CFR Part 11 & EU Annex 11 compliant) |
| Brand | Agilent Technologies |
|---|---|
| Model | Cary 660 FTIR |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Spectral Range | Standard Mid-IR (4000–400 cm⁻¹) |
| Spectral Resolution | ≤ 0.25 cm⁻¹ (user-selectable down to 0.1 cm⁻¹) |
| Signal-to-Noise Ratio | ≥ 45,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Detector | High-performance DTGS or optional MCT |
| Beamsplitter | KBr or ZnSe (mid-IR optimized) |
| Interferometer | Precision-machined, dynamically aligned Michelson with HeNe laser reference |
| Scan Speed | Up to 20 kHz mirror velocity |
| Data Format | Compatible with ASTM E1421, JCAMP-DX v6.0, and ISO 14153 |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 7000 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–3300 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | UV-Vis: 0.01–5.00 nm |
| NIR | 0.04–20 nm |
| Absorbance Range | Up to 10 Abs |
| Max Scan Speed | UV-Vis 2000 nm/min, NIR 8000 nm/min |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8454 |
| Instrument Architecture | Dual-Wavelength |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | Not Specified |
| Wavelength Accuracy | Not Specified |
| Stray Light | Not Specified |