| Brand | Agilent Technologies |
|---|---|
| Model | Cary Eclipse Fluorescence Spectrophotometer |
| Light Source | Pulsed Xenon Lamp |
| Wavelength Scan Speed | 24,000 nm/min |
| Data Acquisition Rate | Up to 80 points/sec (steady-state) |
| Detection Range | Extended to 900 nm |
| Detector | Red-Sensitive Photomultiplier Tube (PMT) |
| Excitation/Emission Modes | Fluorescence, Phosphorescence, Chemiluminescence/Bioluminescence, Time-Resolved Phosphorescence |
| Sample Compartment | Ambient-light-immune design (open-lid operation supported) |
| Optional Accessories | Microplate Reader (384-well), Rapid Mixing Unit, BioMelt Thermal Denaturation System |
| Minimum Sample Volume | < 0.5 mL (sub-picomolar fluorescein detection) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Excitation & Emission Wavelength Range | 200–900 nm |
| Wavelength Accuracy | ±1.5 nm |
| Spectral Bandwidth (Excitation/Emission) | 1.5, 2.5, 5, 10, 20 nm (including 10 nm round) |
| Light Source | Pulsed Xenon Lamp (80 Hz) |
| Detector | High-Sensitivity PMT |
| Scan Speed | Up to 24,000 nm/min |
| Data Acquisition Interval | As fast as 12.5 ms per point |
| Dimensions (W × D × H) | 608 × 644 × 271 mm |
| Weight | 30 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Software | Cary WinFLR |
| Warranty | 10-year lamp lifetime guarantee (applies to new systems purchased from Agilent or authorized partners) |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Cobalt Insight100 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Regulatory Compliance | ECAC Standard 3 (Type A & B) |
| False Alarm Rate | ~2.5% across container types |
| Scan Time | ≤5 seconds per sample |
| Upgrade Path | Field-upgradable to Insight100M |
| Software Platform | Cobalt Overview Management Server |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Cobalt Insight200M |
| Instrument Type | Grating-Based Raman Spectrometer |
| Certification | ECAC Type A & Type B Certified LEDs |
| Laser Class | Class 1 |
| Power Supply | 90–264 VAC, 50–60 Hz |
| Power Consumption | 200 W continuous |
| Dimensions (W × D × H) | 562 mm × 417 mm × 536 mm |
| Weight | 25 kg |
| Sample Throughput Time | ≤6 seconds per container |
| False Alarm Rate | <2.5% (validated in operational deployment) |
| Container Compatibility | Aerosols, cardboard/paper, transparent/colored/frosted/opaque glass, aluminum beverage cans, foil pouches, food tins, Tetra Pak®, sorbent tubes |
| Max Container Size | 38 cm height × 20 cm diameter |
| Volume Range | 10 mL to 3 L |
| Regulatory Compliance | CE-marked, UK Department for Transport approved |
| Origin | USA |
|---|---|
| Instrument Type | Portable |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Detector Options | DTGS or Thermoelectrically Cooled MCT |
| Weight | 2.2 kg (4.9 lb) |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −25–75 °C |
| Battery | Rechargeable Li-ion, 10.8 V, 4400 mAh (4 units included) |
| Interface | Integrated PDA touchscreen terminal with wireless PC connectivity |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | RapID |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Discontinued Date | 1 August 2025 |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Resolve |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| IP Rating | IP67 |
| Laser Wavelength | 830 nm |
| Maximum Laser Power | 475 mW |
| Dimensions (W × H × D) | 155 mm × 290 mm × 73 mm |
| Weight | 2.2 kg |
| Power Supply | Rechargeable Lithium-ion Battery with AC Adapter |
| Connectivity | USB 2.0, Optional Wi-Fi Module |
| Operating Modes | Through-Packaging SORS, Surface Raman, Glass Bottle Mode |
| Analysis Time (Typical) | ~60 s for Solids, Powders, Liquids, and Mixtures |
| Supported Languages | English, Korean, German, Chinese, French, Portuguese, Japanese, Spanish, Czech |
| Onboard Library Tiers | Standard, Toxic & Hazardous Materials, Comprehensive |
| Library Update Frequency | Biannual |
| Software Platform | Agilent Command Instrument Group Management Software |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin Category | Imported Instrument |
| Model | TRS100 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 50–2300 cm⁻¹ |
| Laser Wavelength | 830 nm |
| Laser Power | 650 mW |
| Calibration Standards | NIST SRM 706a (polystyrene), NIST SRM 2246 (green glass), Mercury-Argon Light Source Calibration Tray |
| Detection Limit | 0.1% w/w (API in solid dosage forms) |
| Regulatory Compliance | US FDA 21 CFR Part 11, EU Annex 11, USP <858>, USP <1858>, EP <2.2.48> |
| Sustainability Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 350–2000 cm⁻¹ |
| Spectral Resolution | 12–20 cm⁻¹ |
| Minimum Wavenumber | 350 cm⁻¹ |
| Spectral Repeatability | < ±0.2 cm⁻¹ |
| Laser Wavelength | 830 nm |
| Laser Power | 450 mW (Class 3B) |
| Battery Life | Up to 4 hours |
| Weight | 1.62 kg |
| Dimensions (W × D × H) | 127 mm × 257 mm × 60 mm |
| Regulatory Compliance | USP <1120>, <1058>, <858>, <1225>, <1858>, EP 2.2.48, 21 CFR Part 11, EU Annex 11 |
| Software Features | Guided method development & validation, audit trail, electronic signatures, LIMS integration, QR/barcode scanning, Wi-Fi & Ethernet connectivity |
| Accessories Included | Dual rechargeable Li-ion batteries, bottle adapter head, NIST-traceable system verification test slide, wrist strap, glass vial stand, shoulder strap, five sample vials |
| Language Support | English, French, Portuguese, Chinese, German, Italian, Korean, Spanish, Japanese |
| Sustainability Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agiltron |
|---|---|
| Origin | USA |
| Model | PeakSeeker Pro |
| Excitation Wavelength | 785 nm |
| Laser Power | 5–300 mW |
| Spectral Range | 200–3000 cm⁻¹ |
| Spectral Resolution | ≈12 cm⁻¹ |
| Wavelength Stability | <1 cm⁻¹ over 12 h |
| Photometric Stability | <4% over 12 h |
| Numerical Aperture | NA = 0.22 |
| Sample Spot Size | 0.1–0.3 mm |
| Dimensions (W×D×H) | 36 × 29 × 11 cm |
| Weight | <3.6 kg |
| Operating Temperature | −25°C to +45°C |
| Power Input | 100–240 VAC, 50/60 Hz → 15 VDC adapter |
| Brand | Agiltron |
|---|---|
| Origin | USA |
| Model | PinPointer |
| Instrument Type | Handheld Raman Spectrometer |
| Excitation Wavelength | 785 nm |
| Laser Power | 5–500 mW |
| Raman Spectral Range | 200–2400 cm⁻¹ |
| Spectral Resolution | ~10 cm⁻¹ |
| Raman Shift Stability | < 1 cm⁻¹ over 12 h |
| Photometric Stability | < 4% over 12 h |
| Collection Numerical Aperture | 0.28 |
| Working Distance | 5 mm |
| Spot Size | < 0.2 mm |
| Power Supply | Rechargeable Li-ion battery + universal AC adapter (100–240 V, 50/60 Hz) |
| Dimensions | 216 × 109 × 64 mm |
| Weight | 1.36 kg |
| Operating Temperature | −25 °C to +70 °C |
| Brand | KPM Bruins |
|---|---|
| Origin | USA |
| Model | Agricheck XL/Plus |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 730–2500 nm |
| Scan Time | 10–60 s |
| Data Sampling Interval | 1 nm |
| Application Domain | Agricultural Commodities, Feed & Food Processing, Research & Academia |
| Compliance | Designed for ISO 12099, ASTM D6342, and AOAC Official Methods alignment |
| Brand | Agrowing |
|---|---|
| Origin | Israel |
| Model | AMS-10 |
| Spectral Channels | 10 (405, 430, 450, 550, 560, 570, 650, 685, 710, 850 nm) |
| Resolution per Channel | 12 MP |
| Sensor Architecture | Monolithic CMOS with integrated bandpass filter array |
| Optical Distortion | <1% |
| Pixel-Level Spatial Registration | Native, hardware-aligned across all bands |
| Video Capability | 4K-resolution multispectral video (10-channel synchronized) |
| Housing | All-metal and optical-glass construction |
| Dynamic Range | >65 dB (typical) |
| Compliance | CE, RoHS, ISO 9001-manufactured supply chain |
| Brand | AIRSENSE |
|---|---|
| Origin | Imported |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Model | MI10 |
| Wavenumber Range | 500–5000 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Compliance | Designed for field-deployable chemical identification in accordance with ISO 17025-aligned operational workflows |
| Software | Embedded real-time spectral acquisition and library-matching interface |
| Data Handling | On-device storage with USB export and optional cloud-sync capability |
| Environmental Rating | IP54-rated enclosure for dust and splash resistance |
| Power Supply | Rechargeable Li-ion battery (≥4 h continuous operation) |
| Dimensions & Weight | 320 × 240 × 120 mm |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | AISA Eagle, AISA Hawk, AISA Dual |
| Spectral Range | 400–970 nm (Eagle), 970–2450 nm (Hawk), 400–2450 nm (Dual) |
| Spatial Pixels | 512 or 1024 (Eagle), 320 (Hawk and Dual) |
| Spectral Bands | 488 (Eagle), 256 (Hawk), 500 (Dual) |
| Frame Rate | 160 Hz (Eagle), 100 Hz (Hawk and Dual) |
| Weight | < 12 kg (system total) |
| Integration | GPS/INS-aided georeferencing module included |
| Data Acquisition | Real-time onboard storage with lossless compression |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AisaFENIX |
| Pricing | Upon Request |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3400 Series |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AGT-LIBS |
| Pricing | Upon Request |
| Instrument Form Factor | Benchtop |
| Integration Level | Fully Integrated System |
| Laser Pulse Energy | ≤ 100 mJ |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | LMHJ.B02 |
| Instrument Type | Handheld |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LMKS |
| Pricing | Upon Request |
| Instrument Type | Handheld |
| Integration | Fully Integrated Unit |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LMKS.A01 |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | 0.2 mJ |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LT.D00 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Pulse Energy | 100 mJ |
| Spectral Range | 185–340 nm (expandable to 180–960 nm) |
| Optical Resolution | 0.10–0.45 nm |
| Sample Analysis Time | 1–60 s (user-configurable) |
| Sample Stage | Motorized 3D Positioning + Automatic Rotation |
| Imaging System | Integrated HD Camera + Real-time Video Feed |
| Operating System | Embedded Windows-based Industrial PC |
| Display | Color Touchscreen Interface |
| Cooling Method | Air-Cooled Laser |
| Dimensions (L×W×H) | 405 × 510 × 430 mm (screen closed) |
| Weight | 43 kg |
| Operating Voltage | AC 220 V |
| Ambient Temperature Range | 10–40 °C (optimal at 20 °C) |
| Relative Humidity | <60% RH (non-condensing) |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PJ-10 |
| Pricing | Available upon Request |
| Excitation Source | Microwave-induced Plasma (MIP) |
| Optical Range | 190–1100 nm |
| Spectral Resolution | 0.10–0.25 nm |
| Detection Limit (Cd) | 0.01 ppm |
| Analysis Time | <60 s |
| Sample Form | Direct Solid Analysis |
| Sample Preparation | Minimal—homogenization and pelletization only (no acid digestion) |
| Power Supply | 110–260 VAC |
| Dimensions (Closed) | 400 × 410 × 427 mm (L×W×H) |
| Dimensions (Open) | 400 × 410 × 662 mm |
| Weight | 32 kg |
| Power Consumption | 200 W |
| Display | 12-inch capacitive touchscreen |
| Storage | 128 GB SSD |
| Data Interfaces | 4× USB, 1× Ethernet |
| Warm-up Time to Stability | 15 min |
| Detectable Elements | Cd, Cr, Cu, Pb, Zn, Ca, Fe, and others |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Nano-100 |
| Optical Design | Single-beam |
| Detector | 2048-pixel linear CCD array |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | <0.5 nm |
| Spectral Bandwidth | ≤3 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Sample Volume | 0.5–2.0 µL |
| Pathlength Options | 0.2 mm (high-concentration mode), 1.0 mm (standard mode) |
| Absorbance Accuracy | ±1% at 7.332 A (260 nm) |
| Absorbance Precision | ±0.003 A |
| Absorbance Range (10-mm equivalent) | 0.04–90 A |
| dsDNA Quantification Range | 2–4500 ng/µL |
| Measurement Time | <5 s |
| Light Source | Pulsed xenon flash lamp (rated lifetime ≥1×10⁹ flashes, ~10 years) |
| Power Supply | DC 24 V, 2 A |
| Power Consumption | 20 W (operational), 5 W (standby) |
| Dimensions (W×D×H) | 200×250×166 mm |
| Weight | 2.6 kg |
| Software Compatibility | Windows XP/7/8 |
| Data Export | CSV, PDF, Excel-compatible formats |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Nano-300 |
| Instrument Architecture | Single-beam |
| Detector | 2048-element linear CCD array |
| Wavelength Range | 200–800 nm |
| Wavelength Automation | Motorized scanning |
| Spectral Bandwidth | 1.5 nm (100 µm slit) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Stray Light | <0.05 % at 400 nm |
| OD600 Mode | LED source at 600 ± 8 nm, Absorbance Range: 0–4 A |
| Sample Volume | 0.5–2.0 µL |
| Optical Path Lengths | 0.2 mm (high-concentration), 1.0 mm (standard) |
| Absorbance Accuracy | ±1 % (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.003 A |
| Absorbance Range (10-mm equivalent) | 0.04–90 A |
| dsDNA Detection Range | 2–4500 ng/µL |
| Measurement Time | <5 s |
| Light Source | Pulsed xenon lamp (OD600 mode: high-stability LED) |
| Data Interface | USB 2.0 |
| Operating System | Custom Android OS (v8.1), 7-inch capacitive touchscreen |
| Power Supply | DC 24 V, 2 A |
| Max Power Consumption | 25 W |
| Standby Power | 5 W |
| Dimensions (W×D×H) | 210 × 268 × 181 mm |
| Weight | 2.8 kg |
| Brand | Alpao |
|---|---|
| Origin | France |
| Model | DMM Series |
| Surface Roughness (RMS) | <15 Å |
| Max. Stroke per Mode | ±100 µm |
| Coating | Protected Silver |
| LIDT (1064 nm, 12 ns, 10 Hz) | 880 mJ/cm² |
| LIDT (CW, 1064 nm) | 50 W |
| Control Interface | Ethernet (Web-based API) / USB (via dongle) |
| Zernike Mode Support | Yes |
| Enclosure | Standard Cylindrical Mount |
| Brand | Alpes Lasers |
|---|---|
| Origin | Switzerland |
| Model | GLIDER |
| Tuning Range | 6.7–33 µm (≈300–1500 cm⁻¹, max. ~850 cm⁻¹ per module) |
| Output Mode | Pulsed (standard), CW-capable under specific conditions |
| Interface | Web-based GUI, Linux-based embedded controller, RJ45 Ethernet |
| Data Acquisition | Dual 16-bit synchronized analog input channels |
| Beam Control | Full motorized beam steering |
| Optical Interface | Standard kinematic mounts (e.g., SM1, C-mount compatible) |
| Purge Capability | Full-system gas purge port (N₂ or dry air) |
| Wavelength Monitoring | 12-bit analog real-time wavelength output |
| Fiber Coupling | Optional multimode fiber output (e.g., ZrF₄ or Chalcogenide, core Ø ≥ 400 µm) |
| Brand | Oxford Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | alphaCART |
| Instrument Type | Portable Confocal Raman Microscope |
| Laser Options | 532 nm, 633 nm, 785 nm (custom wavelengths available) |
| Spectral Range | ~90–3500 cm⁻¹ (laser-dependent) |
| Spatial Resolution | Diffraction-limited |
| Spectral Resolution | High across full range |
| Detector | Scientific-grade low-noise CCD spectrometer camera |
| Brand | ASI |
|---|---|
| Origin | USA |
| Model | Alphachron He-1 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Wavelength | 915 nm (Diode Laser) |
| Laser Energy | 200 mJ/pulse (typical, configurable) |
| Vacuum System | Hybrid — Dry Diaphragm Roughing Pump + Turbo-Molecular Pump with Controller + Ion Pump with Controller |
| Heating Options | Primary: Nd:YAG or Fiber-Coupled Diode Laser Ablation |
| Optional | Quartz-Halogen Resistive Heating Module |
| Software Platform | LabVIEW-Based Custom Control Suite with Sequence Editor, Audit Trail, and GLP-Compliant Data Logging |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SEC2020 |
| Spectral Range | 200–1025 nm |
| Detector Type | Custom CMOS Array (Optimized for UV-VIS-NIR) |
| Optical Resolution (FWHM) | 1.3 nm |
| Sensitivity Range | 200–1025 nm |
| Signal-to-Noise Ratio | 1000:1 (at full integration time, 60 s) |
| Dynamic Range | 7.5 × 10⁹ (system-level, 16-bit digitization with multi-exposure synthesis) |
| Stray Light | < 0.09% at 500 nm |