| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Charge-Coupled Device (CCD) |
| Spectral Range | Configurable (130–700 nm) |
| Optical Design | Paschen-Runge Mount with Long Focal Length |
| Temperature Control Stability | ±0.1 °C |
| Software Platform | iAPS Intelligent Alloy Identification System, OMVR Calibration Engine, ASR Spark Filtering Algorithm |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Spectral Range | Configurable (130–700 nm) |
| Optical Design | Paschen-Runge Mount with Long Focal Length |
| Gas Environment | Argon-Flushed Optical Chamber |
| Temperature Control Accuracy | ±0.1 °C |
| Software Compliance | Supports 21 CFR Part 11 Audit Trail & GLP/GMP Data Integrity Requirements |
| Sample Handling | Open-Design Spark Stand with Gravity-Driven Electrode, 32 kg Max Load |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Charge-Coupled Device (CCD) |
| Spectral Range | Configurable from 130 nm to 700 nm |
| Optical Design | Paschen–Runge mounting with extended focal length |
| Temperature Control Stability | ±0.1 °C |
| Software Platform | iAPS Intelligent Alloy Identification System, OMVR Optimized Multi-Variable Regression, ASR Aberrant Spark Removal Algorithm |
| Compliance Ready | ASTM E415, ASTM E1086, ISO 11577, ISO 17025-aligned workflows, FDA 21 CFR Part 11 optional audit trail module |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Model | ARTUS 8 U |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | High-Resolution CCD Array |
| Focal Length | 400 mm |
| Grating Line Density | 2400 l/mm (Visible), 3600 l/mm (UV) |
| Wavelength Range | 140–680 nm |
| Spectral Acquisition Mode | Full-Spectrum Direct Reading |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Calibus 3B |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Pulse Energy | Not Specified (Nanosecond-Pulsed Solid-State Laser) |
| Wavelength Range | 190–700 nm |
| Detector | CMOS Array |
| Cooling | Active PID-Controlled Thermal Stabilization |
| Gas Purge | Argon Circulation System |
| Operating Temperature Range | −10 °C to +40 °C |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Calibus Al |
| Instrument Type | Handheld |
| Integration | Fully Integrated |
| Laser Energy | 1 mJ (typical, single-pulse) |
| Laser Pulse Width | Nanosecond-range |
| Wavelength Coverage | 190–700 nm |
| Detection Detector | CMOS-based spectrometer array |
| Operating Temperature Range | –10 °C to +40 °C |
| Argon Consumption | ~5 mL per shot |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Optical System | Full-Spectrum Holographic Grating |
| Vacuum Requirement | None |
| Wavelength Range | Configurable (typically 130–800 nm) |
| Resolution | High spectral resolution enabled by optimized optical path and CCD pixel density |
| Sample Handling | Open-type spark stand with X-Y motorized sample stage |
| Compliance | Designed to support ISO/IEC 17025, ASTM E415, ASTM E1086, and GB/T 4336 workflows |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Model | MERLIN 4 |
| Excitation | Spark Source |
| Optical System | Paschen-Runge Mount with Holographic Concave Grating |
| Detector | High-Resolution CCD Array |
| Spectral Range | 130–800 nm |
| Resolution | ≤ 10 pm at 200 nm |
| Sample Stage | Motorized X-Y Translation with Open Spark Stand |
| Compliance | ASTM E415, ISO 11577, GB/T 4336 |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Optical Design | Full-Spectrum Holographic Grating |
| Sample Handling | Open-Style Horizontal/Vertical Translational Spark Stand |
| Compliance | Designed for ISO/IEC 17025-aligned laboratories, supports ASTM E415, E1086, and ISO 6892-1 elemental analysis workflows |
| Software | ARUN SpectraSuite with audit trail, user access levels, and data export compliant with FDA 21 CFR Part 11 requirements |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Optical Design | Full-Spectrum Holographic Grating |
| Sample Handling | Open-Type Adjustable Spark Stand with X-Y Translation |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, supports ASTM E415, E1086, and ISO 6892-2 traceable analysis workflows |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TDLA-8000 |
| Pricing | Available Upon Request |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UVF Series Total Sulfur Analyzer |
| Price | Upon Request |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Hi-Res NG |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs (SWIR 1 & 2), Si Array (VNIR) |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 3 nm @ 700 nm |
| SNR | VNIR: 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm |
| SWIR 1 | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm |
| SWIR 2 | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Dynamic Range | 16-bit |
| Stray Light | VNIR: 0.02% |
| SWIR 1 & 2 | 0.01% |
| Sampling Interval | 1.4 nm (350–1000 nm) |
| Scan Time | 100 ms |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Max Radiance | VNIR: 2× solar |
| SWIR | 10× solar |
| Channels | 2151 |
| FOV | 25° (standard 1.5 m fiber optic cable) |
| Calibration Traceability | NIST-traceable reflectance, radiance, and irradiance (radiometric calibration optional) |
| Weight | 5.44 kg |
| Warranty | 12 months comprehensive coverage including technical support |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec 4 Hi-Res NG |
| Spectral Range | 350–2500 nm |
| Detector Configuration | Si (350–1000 nm), TE-cooled InGaAs (1001–1800 nm), TE-cooled InGaAs (1801–2500 nm) |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400 nm & 2100 nm |
| Sampling Interval | 1.4 nm (350–1000 nm), 1.1 nm (1001–2500 nm) |
| Stray Light | <0.02% (VNIR), <0.01% (SWIR 1 & 2) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Integration Time | 100 ms typical |
| NEΔL (VNIR) | 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm |
| NEΔL (SWIR 1) | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm |
| NEΔL (SWIR 2) | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Radiance Dynamic Range | Up to 2× solar (VNIR), 10× solar (SWIR) |
| Calibration Traceability | NIST-traceable radiometric, reflectance, irradiance, and colorimetric calibrations available |
| Fiber Input | 1.5 m, 25° FOV (lens options available) |
| Channels | 2151 spectral bands |
| Weight | 5.44 kg |
| Warranty | 12 months comprehensive coverage with technical support |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FieldSpec HandHeld 2 |
| Instrument Type | Portable |
| Application Domain | Academic & Research (Universities, Earth Observation Labs, Environmental Monitoring) |
| Operating Principle | Fixed Grating with Linear CCD Array Detector (Non-scanning) |
| Wavelength Range | 325–1075 nm |
| Spectral Sampling Interval | 1.5 nm |
| Scan Speed | 10 spectra/sec |
| Measurement Mode | Reflectance (with optional irradiance calibration) |
| Calibration Software | RS3™ |
| Drift Compensation | DriftLock™ Baseline Stabilization Technology |
| Detector Type | Back-thinned Si CCD |
| FOV | 25° (Full Angle) |
| NEdL | 5×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| Spectral Resolution | <3.0 nm FWHM @ 700 nm |
| Wavelength Accuracy | ±1 nm |
| Integration Time Range | 8.5 ms to 10 s (programmable) |
| Onboard Storage | Up to 2000 spectra |
| Display | 2.7-inch tilt-adjustable color LCD (6.8 cm diagonal) |
| Power Supply | 4× AA batteries (rechargeable NiMH or alkaline) or 5 V / 1.5 A AC/DC adapter |
| Battery Life | Up to 5 h (Li-ion), 2.5 h (NiMH), ~1.5 h (alkaline) |
| Dimensions (H×W×D) | 90 × 140 × 215 mm |
| Weight | 1.2 kg (incl. batteries) |
| Operating Temperature | 0–40 °C |
| Targeting Aid | Integrated Class 2 IR laser pointer (650 nm, visible alignment optional) |
| Connectivity | Mini-B USB, mini-TRS remote trigger port, dual Type-A USB expansion ports |
| Software Suite | RS3™ real-time acquisition & configuration, ViewSpecPro™ spectral analysis & chemometric modeling, HH2 Sync Interface for external GNSS/IMU synchronization |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec® 4 HI-RES |
| Detector Type | PDA |
| Wavelength Range | 300–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 8 nm @ 1400/2100 nm |
| Scan Time | 100 ms |
| SNR | VNIR: 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm, SWIR1: 1.4 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm, SWIR2: 2.2 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Stray Light | VNIR: 0.02%, SWIR1/2: 0.01% |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Number of Channels | 2151 |
| Communication | 10/100 Base-T Ethernet, IEEE 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (battery included: +1.2 kg) |
| Battery Life | 6 h (NiMH, 12 V, 9 Ah) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC, 50/60 Hz or 12 VDC, 5 A |
| Certifications | CE (EN61010-1:2001), EU Directives 2006/95/EC & 2004/108/EC, NIST-traceable calibration, WEEE compliant |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec® HandHeld 2™ |
| Detector Type | PDA |
| Wavelength Range | 325–1075 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Resolution | <3.0 nm @ 700 nm |
| NEdL | 5×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| FOV | 25° |
| Integration Time | 8.5 ms (min, adjustable) |
| Memory Capacity | Up to 2000 spectra |
| Display | 2.7″ tilting color LCD |
| Power | 4×AA batteries (rechargeable or alkaline) or 5 V / 1.5 A AC/DC adapter |
| Battery Life | up to 5 h (Li-ion), 2.5 h (NiMH), ~1.5 h (alkaline) |
| Dimensions (H×W×D) | 90 × 140 × 215 mm |
| Weight | 1.2 kg (incl. batteries) |
| Operating Temperature | 0–40 °C |
| Mounting | 1/4″-20 tripod thread |
| Software | RS3™, ViewSpecPro™, HH2 Sync Interface |
| Brand | ASD |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized General Distributor |
| Import Status | Imported |
| Model | FSA (FieldSpec Assistant) Smart Handle |
| Pricing | Available Upon Request |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | LabSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 6 nm @ 1400/2100 nm (Hi-Res) / 10 nm @ 1400/2100 nm (Standard) |
| Scan Time | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Detector Configuration | 512-pixel Si array (350–1000 nm) + dual TE-cooled InGaAs arrays (1000–1800 nm & 1800–2500 nm) |
| Certifications | CE (EN 61010-1:2001), EU Directive 2006/95/EC & 2004/108/EC, NIST-traceable calibration |
| Software Compatibility | Indico® Pro, GRAMS (Thermo Scientific), The Unscrambler® (Camo) |
| Connectivity | 10/100Base-T Ethernet, IEEE 802.11g Wi-Fi (up to 300 m line-of-sight) |
| Power | 12 VDC NiMH battery (6 h typical operation), AC/DC adapter (90–240 VAC, 50/60 Hz) |
| Dimensions | 12.7 × 35.6 × 29.2 cm |
| Weight | 5.2 kg (with battery) |
| Brand | ASD |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QualitySpec Trek |
| Price | Upon Request |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 mm × 250 mm × 750 mm |
| Weight with Battery | 2.5 kg (5.5 lbs) |
| Weight without Battery | 2.0 kg (4.3 lbs) |
| Operating Languages | English, Spanish, Chinese |
| Integrated GPS | Yes |
| Voice Memo Function | Yes |
| Display | Integrated LCD |
| Connectivity | Wireless (Wi-Fi/Bluetooth) |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400/2100 nm |
| Scan Speed | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Stray Light | VNIR 5000:1 (0.02%), NIR 10000:1 (0.01%) |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | 512-pixel Si array (350–1000 nm), TE-cooled InGaAs gradient-index arrays (1001–1800 nm & 1801–2500 nm) |
| Interface | 10/100 Base-T Ethernet, 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (instrument), +1.2 kg (battery) |
| Battery Life | ~6 h (standalone) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC / 50–60 Hz or 12 VDC / 60 W |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 75 photons/count |
| SNR | VNIR 9000:1 @ 700 nm |
| SWIR1 9000 | 1 @ 1400 nm |
| SWIR2 4000 | 1 @ 2100 nm |
| Dynamic Range | 7.5×10⁹ |
| Stray Light | VNIR 5000:1 (0.02%) |
| NIR 10000 | 1 (0.01%) |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TerraSpec Halo |
| Pricing | Upon Request |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Halo |
| Instrument Type | Portable |
| Application Field | General (Universities, Research Institutes) |
| Operating Principle | Grating-Based Array Detector (Non-Scanning) |
| Wavelength Range | 350–2500 nm |
| Scan Speed | 10 spectra/sec |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | ASD Halo Manager |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 × 250 × 750 mm |
| Weight (with battery) | 2.5 kg (5.5 lbs) |
| Weight (without battery) | 2.0 kg (4.3 lbs) |
| Supported Languages | English, Spanish, Chinese |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aurora |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Benchtop |
| Integration Level | Fully Integrated |
| Laser Pulse Energy | 200 mJ (at 1064 nm, 5 ns FWHM) |
| Repetition Rate | Up to 100 Hz |
| Spectral Range | 190–1000 nm |
| Optical Resolution | ≤ 0.07 nm (FWHM at 300 nm) |
| Detector | Back-illuminated, deep-depletion CCD with thermoelectric cooling to −60 °C |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Pulse Energy | 200 mJ per pulse at 1064 nm |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200-1 |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Pulse Energy | 200 µJ (at 800 nm, 1 kHz) |
| Motion Stage | X-Y travel range 100 mm × 100 mm, positioning resolution 0.2 µm |
| Spectrometer | Czerny–Turner optical design |
| Detector | Intensified CCD (ICCD) |
| Certification | CE |
| Optional Upgrade | Tandem LA Configuration |
| Power Supply | 110–240 VAC, 50/60 Hz, 5 A (10 A fuse) |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200-2 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Pulse Energy | 200 µJ (at 800 nm, 1 kHz) |
| Laser Pulse Duration | <500 fs |
| Repetition Rate | 1–1000 Hz (software-adjustable) |
| Wavelength | 800 nm (fundamental), optionally tunable via OPA |
| Imaging | Wide-field optical view + high-magnification telecentric microscope (up to 100×) |
| Gas Control | Digital mass flow controllers (MFCs) for Ar, He, and auxiliary gases |
| Compatibility | Quadrupole ICP-MS, multi-collector ICP-MS, and time-of-flight ICP-MS |
| Brand | ASI |
|---|---|
| Origin | USA |
| Model | J200-3 |
| Form Factor | Benchtop |
| Integration | Fully Integrated |
| Laser Wavelength | 213 nm (Q-switched Nd:YAG) |
| Pulse Energy | 200 mJ (adjustable) |
| Dual-Spectrometer Capability | LIBS + Optional ICP-MS Interface |
| Depth Profiling Resolution | Sub-micron per pulse (dependent on ablation rate and matrix) |
| Sample Chamber | Flex™ Modular Vacuum-Compatible Chamber with Interchangeable Liners |
| Gas Control | Dual High-Precision Digital Mass Flow Controllers (MFCs) |
| Imaging | Co-registered Dual-Camera System (High-Magnification Microscope + Wide-Field Surface View) |
| Brand | ASI |
|---|---|
| Origin | USA |
| Type | Benchtop |
| Configuration | Modular |
| Laser Wavelength | 193 nm (Excimer) |
| Pulse Energy | 200 mJ (typical, at laser output) |
| Fluence | >20 J/cm² |
| Sample Stage Travel Range | 155 mm × 105 mm |
| Sample Capacity | 20 × 1-inch targets or 6 thin sections |
| Dimensions (W×D×H) | 119 × 89 × 195 cm |
| Weight | 750 kg (1600 lbs.) |
| Flush Time | Optimized for rapid washout (<30 s typical for standard ablation cells) |