Surface & Interface Property Testing
Filter
Showing 31–60 of 203 results
| Brand | Asida |
|---|---|
| Model | JK3200, JK3600 |
| Detectable Hole Diameter Range | 0.15–10 mm |
| PCB Size Range | 100 × 150 mm to 630 × 650 mm |
| PCB Thickness Range | 0.3–10 mm |
| Max. Hole Count per Board | 150,000 |
| Inspection Speed | 3.5–12.5 m/min (adjustable) |
| Hole Position Repeatability | ±40 µm |
| Hole Dimension Tolerance | ±40 µm |
| Minimum Hole-to-Hole Edge Distance | 0.15 mm |
| Detection Method | CIS Contact Image Sensor (Close-Range Linear Array Imaging) |
| Light Source | Diffuse Long-Strip LED Illumination |
| Power Supply | AC 220 V, 50 Hz |
| Compressed Air Requirement | 0.5–0.7 MPa |
| Dimensions (L×W×H) | 3550 × 1200 × 1100 mm |
| Weight | 450 kg |
| Origin | Guangdong, China |
| Distribution Type | Authorized Distributor |
| Brand | ASIDA |
|---|---|
| Model | ZK2130 |
| Origin | Guangdong, China |
| Type | Domestic |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Accuracy at 50 Ω | ±1% |
| Test Length Range | 0.05–2 m |
| Horizontal Resolution | 0.2 mm |
| Vertical Resolution | 0.05 Ω |
| Bandwidth | 3 GHz |
| Compliance | IPC-TM-650, IPC-2141 |
| Test Modes | Single-Ended & Differential Impedance, Differential Pair Delay |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α Series |
| Measurement Principle | Critical Angle Refractometry |
| Measuring Range (Brix) | 0.00–80.0% |
| Temperature Range | −15 to 160°C |
| Brix Resolution | 0.01% (0.00–9.99%), 0.1% (10.0–80.0) |
| Brix Accuracy | ±0.1% |
| Temperature Accuracy | ±1°C |
| Temperature Compensation Range | 5–100°C |
| Output Signals | DC 4–20 mA & RS-232C |
| Prism Material | Synthetic Sapphire |
| Prism Cell Material | SUS316L Stainless Steel |
| Response Time | ~1 second |
| Power Supply | DC 24 V (optional AC 100 V with AD-32 adapter) |
| Enclosure Rating | IP67 |
| Dimensions (H×W×D) | 160 × 167 × 110 mm |
| Weight | 2.4 kg (main unit only) |
| Optional Configurations | CM-800α-EG (ethylene glycol), CM-800α-PG (propylene glycol), CM-800α-SW (brine) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PAL-EC DEC-2 Series |
| Price Range | USD 310 – 440 (FOB) |
| Measurement Range | 0–19.9 mS/cm |
| Resolution | 0.1 mS/cm |
| Accuracy | ±0.2 mS/cm |
| Measurement Method | Drop-in (Contact Electrode) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PAL-pH |
| Price | USD 495 (FOB Yokohama) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.10 |
| Temperature Compensation Range | 10.0–40.0 °C (ATC) |
| Temperature Accuracy | ±0.5 °C |
| Sensor Type | Flat-Surface Glass Electrode with Integrated Reference System |
| Power Supply | 2 × AAA Alkaline Batteries |
| Dimensions | 55 × 31 × 109 mm |
| Weight | 100 g (instrument only) |
| Connectivity | NFC (Android-compatible only) |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration protocols |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 700 |
| Measurement Range | Surface/Interfacial Tension (0.01–2000 mN/m), Dynamic Contact Angle (0°–180°), CMC Detection, Solid Surface Free Energy, Powder Wettability, Sedimentation Rate, Liquid Density |
| Resolution | 0.001 mN/m (tension), 0.01° (contact angle) |
| Balance Capacity | 210 g |
| Temperature Control | –20 °C to +200 °C (with jacketed cell or air bath) |
| Compliance | ASTM D971, ISO 1409, ISO 6295, USP <1046>, GLP/GMP-ready data audit trail |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Maximum Sample Weight | 5.0 g |
| Resolution | 0.001 mg |
| Surface Tension Range | 0–1000 mN/m |
| Surface Tension Resolution | 0.001 mN/m |
| Stage Vertical Speed | 0.01–500 mm/min |
| Standard Sample Vessel Diameter | 50 mm or 70 mm |
| Temperature Range | −10 to +100 °C (standard), optional −30 to +130 °C or ambient to +250 °C |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Principle | Wilhelmy Plate / Du Noüy Ring Method (Force-Based Gravimetric) |
| Compliance | ASTM D971 (Oil-Water Interfacial Tension), ISO 1409, ISO 6295, USP <1058> (for instrument qualification) |
| Temperature Control Options | Circulating bath jacket, integrated temperature probe, vapor-phase temperature control |
| Key Measurables | Surface Tension (mN/m), Interfacial Tension (mN/m), Critical Micelle Concentration (CMC), Dynamic Contact Angle (°), Solid Surface Free Energy (mJ/m²), Powder Wettability (via Washburn method), Sedimentation Rate (mg/s), Liquid Density (g/cm³) |
| Display | Integrated high-resolution LCD with real-time force and tension readout |
| Data Output | USB interface, optional direct thermal printer connection, bundled Attension OneTouch™ software for data logging, CMC curve fitting, and ASTM D971 report generation |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | 703D |
| Measurement Principle | Wilhelmy Plate/Ring Method (Force Balance) |
| Display | Integrated High-Resolution Digital Screen |
| Operation Mode | Standalone Manual Operation (PC Optional) |
| Temperature Control Support | Yes (via Jacketed Cell, Immersion Probe, Vapor Phase Chamber) |
| Compliance Standards | ASTM D971, ISO 1409, ISO 6295, USP <1046>, EN 14370 |
| Data Output | Real-time on-screen display, USB export, optional printer interface |
| Accessories Included | Platinum Plate, Platinum Ring, Density Sphere, Calibration Kit, Ring Correction Tool, Glass Beakers |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Principle | Wilhelmy Plate / Du Noüy Ring Method (Force-Based Gravimetric) |
| Temperature Control Options | Thermostatted Jacket, Immersion Probe, Vapor-Phase Chamber |
| Compliance Standards | ASTM D971, ISO 6295, ISO 1409, USP <1058> (for instrument qualification), GLP/GMP-ready data traceability |
| Data Output | Real-time digital display + USB/RS-232 export + optional printer interface |
| Accessories Included | Platinum plate, platinum ring, density sphere, calibration kit, ring correction tool, standard glass beakers |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | 3D Topography Module |
| Instrument Type | Benchtop Dynamic Contact Angle & Surface Topography System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-resolution mode) |
| Sample Stage Dimensions | 75 × 75 mm |
| Optical Magnification | 0.7×–4.5× |
| Surface Tension Range | 0–2000 mN/m |
| Z-Range Measurement | 1–60 µm |
| Lateral Sampling Area | 1.41 mm × 1.06 mm (single frame) |
| XY Pixel Resolution | 1.1 µm × 1.1 µm |
| Working Distance | 18 mm |
| Max Sample Height | 22 mm |
| Max Sample Width | 180 mm |
| Measurement Time per Point | 5–30 s (at 1280 × 960 resolution) |
| Roughness Parameters Compliant With | ISO 4287, ISO 4288, ISO 11562 |
| Required Hardware Interface | FireWire (IEEE 1394) or PCI slot |
| Sample Requirement | Diffusely reflective surface |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 10 × 10 mm |
| Image Resolution | 782 × 582 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Max Operating Pressure | 400 bar |
| Temperature Range | 1–200 °C |
| Chamber Volume | 77 mL (without piston), 45 mL (with piston) |
| Pressure Control Method | Precision Piston Actuation or Gas/Liquid Injection |
| Construction Material | Certified Stainless Steel (CE Compliant) |
| Dimensions (Theta + Chamber) | 74 × 25 × 61 cm (L×W×H) |
| Weight | 16 kg |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | Unlimited (W) × 50 mm (D) × 200 mm (L) |
| Image Resolution | 744 × 480 pixels |
| Magnification | 744 pixel/mm × 480 pixel/mm |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Brand | Attension |
|---|---|
| Origin | Finland |
| Model | Theta Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Measurement Capabilities | Contact Angle, Surface Tension, Interfacial Tension, Surface Free Energy |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5 MP) |
| Maximum Sample Size | 12-inch wafer |
| Sample Stage Load Capacity | 500 g |
| Rotational Range | 0–360° |
| Maximum Rotation Speed | 180°/s |
| Angular Resolution | 0.005° |
| Vacuum Interface | Yes |
| Automated Positioning | Yes |
| Camera Frame Rate | Up to 3422 fps |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoAFM/attoMFM/attoSHPM |
| Temperature Range | mK to 373 K |
| Magnetic Field Compatibility | up to 15 T |
| Scan Range (4 K) | 30 µm × 30 µm |
| Lateral Resolution (MFM) | < 11 nm |
| Lateral Resolution (SHPM) | 250 nm |
| Z-bit Resolution (4 K, full range) | 7.6 pm |
| Z-bit Resolution (4 K, scan range) | 0.12 pm |
| RMS Z-noise (4 K) | 0.05 nm |
| Vacuum/Atmosphere | 1×10⁻⁶ mbar to 1 bar (He exchange gas) |
| Compatible Cryostats/Magnets | Quantum Design PPMS (1″ & 2″ bore), custom dilution refrigerators |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoAFM/attoMFM/attoSHPM |
| Temperature Range | mK to 373 K |
| Magnetic Field Compatibility | Up to 15 T |
| Scan Range (4 K) | 30 µm × 30 µm |
| Lateral Resolution (MFM) | <11 nm |
| Lateral Resolution (SHPM) | 250 nm (high-res mode) |
| Z-Noise (4 K) | 0.05 nm RMS |
| Z-Bit Resolution (full range) | 7.6 pm |
| XY-Bit Resolution (4 K, 12 µm scan) | 0.18 nm |
| Vacuum/He Atmosphere | 1×10⁻⁶ mbar to 1 bar |
| Compatible Cryostats | Quantum Design PPMS, 1″ & 2″ bore systems |
| Modular Functionality | AFM, MFM, SHPM, c-AFM, EFM, STM, SNOM, Confocal Microscopy |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Model | attoCSFM |
| Operating Temperature Range | 1.5 K – 300 K |
| Magnetic Field Range | 0 – 15 T |
| Optical Spectral Range | 400 – 1600 nm |
| Objective Lens | Cryogenic Confocal Objective (NA = 0.82, Working Distance = 4 mm) |
| Scan Range | 30 × 30 µm (at 4 K) |
| Spatial Resolution | < 50 nm (lateral), < 5 nm (z-height control) |
| Magnetic Field Sensitivity | ≤ 3 nT/√Hz (100 s integration) |
| NV-center-based Diamond Nanosensor Integration | Yes |
| AFM Platform | Tuning-Fork-Based Non-Contact AFM |
| ESR Detection Method | Spin-Dependent Fluorescence via Confocal Microscopy |
| Drift Stability | < 10 nm over 1 h (room-temperature base stability reference) |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| [Brand | Beidou Instruments / HOKUTOcn |
|---|---|
| Origin | Dongguan, Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop Optical Contact Angle Meter |
| Measurement Principle | Digital Image Analysis (Sessile Drop, Pendant Drop, Tilting Plate) |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Angular Resolution | 0.001° |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 130 × 150 mm (customizable) |
| Max Sample Size | 200 mm (W) × ∞ (L) × 30 mm (H) |
| Imaging System | Sony 1/1.8″ Progressive Scan CMOS, 1280 × 1024 @ 80 fps, Rolling Shutter |
| Lens | 0.7×–4.5× Telecentric Contour Lens with ±2.5 mm Focus Adjustment |
| Light Source | Imported Industrial White Cold LED (400–760 nm), PWM + Software Brightness Control, >50,000 h Lifetime |
| Droplet Dispensing | Motorized Syringe Pump, 0.01–25 µL/s, 0.01 µL Precision, Programmable Multi-Point Sequencing |
| Software | CA V2.0 Static & Dynamic Contact Angle + Surface Energy Analysis Suite (Windows 10 64-bit)] |
| Brand | Beidou Instruments (HOKUTOcn) |
|---|---|
| Origin | Dongguan, Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Category | Domestic |
| Model | CA100S |
| Price | USD 5,000 (approx.) |
| Instrument Type | Video-Based Optical Contact Angle Meter |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Measurement Accuracy | ±0.1° |
| Angular Resolution | 0.001° |
| Standard Sample Stage | 130 × 150 mm (customizable) |
| Max Sample Dimensions | 200 (W) × ∞ (L) × 30 (H) mm |
| Imaging Sensor | 1/1.8″ Progressive Scan CMOS (1280 × 1024) |
| Frame Rate | 30 fps |
| Optical Zoom | 0.7×–4.5× |
| Droplet Dispensing Precision | ±0.1 µL |
| Dispensing Speed | 0.01–25 µL/s |
| Light Source | Industrial-grade white LED (400–760 nm), PWM-dimmable, >20,000 h lifetime |
| Power Supply | 220 V AC, 50–60 Hz |
| Power Consumption | 10 W |
| Dimensions (W × L × H) | 655 × 180 × 500 mm |
| Weight | 14 kg |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | BEST-121 |
| Price | USD 2,800 (approx.) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | 3H-2000PWP |
| Instrument Type | Static/Dynamic Vapor Adsorption Analyzer |
| Measurement Principle | Knudsen Effusion Mass Loss Method |
| Analysis Stations | 2 sample + 2 reference stations (4 total) |
| Sample Mass Range | 10–1000 mg |
| Mass Resolution | 1 µg |
| Vacuum System | Dual-stage mechanical pump (1×10⁻² Pa) + turbomolecular pump (1×10⁻⁶ Pa) |
| Pressure Range | 0–1 torr & 0–1000 torr (dual-range, segmented) |
| Temperature Range | –180 °C to 900 °C (accuracy ±0.1 °C, stability <0.1 °C) |
| Isothermal Control Range | Ambient to 60 °C (accuracy ±0.2 °C, stability <0.1 °C) |
| Temperature Program | 32-segment ramping with overheat protection |
| Sealing | Oil-resistant & corrosion-resistant valve and tubing system |
| Dimensions | H110 × W100 × L70 cm |
| Weight | 200 kg |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BSD-MAB |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Gas Mixture Compatibility | Binary and multicomponent gas–gas, gas–vapor, vapor–vapor systems |
| Mass Flow Controllers (MFCs) | 4–8 independently programmable channels |
| Breakthrough Columns | Standard stainless-steel columns (2 mL and 8 mL volumes) |
| Adsorption Pressure Range | Ambient to 10 MPa (optional high-pressure modules: up to 1 MPa or 3 MPa) |
| Adsorption Temperature Control | Circulating water bath (−20 °C to 80 °C, ±0.1 °C stability) |
| High-Temperature Furnace | Ambient to 600 °C (customizable beyond) |
| Detection Systems | Integrated thermal conductivity detector (TCD) |
| Detection Limits | TVOC: 5 × 10⁻¹² g/mL |
| SO₂ | 14 × 10⁻¹² g/mL |
| NH₃ | 16 × 10⁻¹² g/mL |
| Vapor Generation System | P/P₀ control range 0.1%–99.99%, accuracy ±1% |
| Vacuum Activation | <0.1 Pa base pressure |
| Corrosive Gas Compatibility | SO₂, NH₃, organic vapors (compatible with fluorocarbon-sealed components) |
| Regulatory Compliance Support | ASTM D5228, ISO 12213-2, USP <621>, GLP-compliant data audit trail (via optional software module), FDA 21 CFR Part 11-ready configuration available |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSD-MAB1 |
| Gas Range | Binary & Ternary Mixtures Including Gas/Gas, Gas/Vapor, Vapor/Vapor |
| MFC Channels | 4–8 |
| Breakthrough Columns | Standard 2 mL & 8 mL Stainless Steel or Quartz Columns (Custom Volumes Available) |
| Adsorption Pressure | Ambient to 10 MPa |
| Adsorption Temperature | Circulating Water Bath (−20 °C to 80 °C), High-Temperature Furnace (RT to 600 °C |
| Detector Options | Integrated TCD, Optional Online GC or Mass Spectrometer (MS) |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BSD-PB |
| Price Range | USD 14,000 – 42,000 |
| Pore Size Range (Gas-Liquid) | 0.02–500 µm |
| Pore Size Range (Liquid-Liquid) | 5–500 nm |
| Vacuum-Assisted Wetting | Integrated automatic system |
| Dual Pressure Sensors | 0–1 bar & 0–40 bar, ±0.05 mbar accuracy |
| Dual Flow Sensors | 0–1 L/min & 0–200 L/min, ±0.1 mL/min accuracy |
| Compliance | GB/T 32361-2015, ASTM F316-03, ASTM D6767-02, ISO 2942, DIN ISO 4003, BS 7591-4, HY/T 051, HY/T 064 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-PHC |
| Pricing Range | USD 70,000 – 140,000 (FOB) |
| Measurement Method | Static Volumetric Method |
| Temperature Range | Ambient to 80 °C (standard) |
| Pressure Range | Adsorption: 0–20 MPa (standard), 0–50 MPa / 0–69 MPa (optional) |
| Confining (Cladding) Pressure | 0–50 MPa / 0–70 MPa (optional) |
| Ultimate Vacuum | <1×10⁻⁶ mbar (equivalent to full-scale 690 bar operation) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BSD-PHD |
| Measurement Method | Volumetric (Static Capacity) Method |
| Temperature Range | –196 °C to 1100 °C |
| Pressure Range | 0–20 MPa |
| Ultimate Vacuum / Maximum Pressure | Up to 690 bar (69 MPa) |
| Repeatability Error | < ±2% |
| Pressure Sensor Accuracy | ±0.01% FS, Long-term Stability: ±0.025% FS |
| Air-Bath Temperature Control | 40.0 °C ±0.1 °C |
| Safety | Integrated combustible gas alarm, high-pressure integrity tested, optional alarm interlock system |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSD-PHU |
| Testing Method | Static Volumetric Method |
| Temperature Range | –196 °C to 80 °C (standard) |
| Pressure Range | High vacuum to 700 bar (70 MPa) |
| Ultimate Vacuum | 1×10⁻² to 1×10⁻⁶ Pa |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MAX X |
| Instrument Type | Static Vapor Adsorption Analyzer |
| Pressure Sensor Ranges | 1000 Torr / 10 Torr / 0.1 Torr |
| Temperature Control | Heated Manifold (50 °C standard, optional 80 °C), Air-Bath Sample Chamber |
| Gas Path | Electropolished Stainless Steel with Metal-Sealed Pneumatic Valves |
| Free Space Compensation | Patented Advanced Free Space Measurement (AFSM™) Technology |
| Vapor Compatibility | H₂O, Ethanol, Benzene, and other non-corrosive VOCs (up to 40 °C standard |
| Gas Inlets | Standard 3-port corrosion-resistant |
| Measurement Modes | High-Precision Mode (3 sample + 1 reference station) & Multi-Station Mode (4 sample stations + dedicated P₀ port) |
| Software | BELCONTROL OS with real-time trend logging, system diagnostics, email status alerts, and multilingual UI (English/Japanese) |
| Compliance Support | Designed for GLP/GMP-aligned workflows |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MR1 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic Gas Flow Adsorption Method |
| Analysis Stations | 1 Pre-treatment Station, 1 Analysis Station |
| Surface Area Range | >0.01 m²/g |
| Pressure Range | 0.30 (standard), 0.02–0.9 (upgraded) |
| Adsorptive Gases | He/N₂ or He/Kr mixtures |
| Pretreatment Temperature | Room Temperature to 400 °C |
| Repeatability | <±1% |
| Measurement Time per Sample | ~10 min (analysis only) |
| Compliance Option | FDA 21 CFR Part 11 & 3Q Validation Support |
| Control Interface | Integrated Touchscreen (standalone operation) |
| Dimensions | W350 × D368 × H553 mm |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BD2000 |
| Pricing | Available Upon Request |