Surface & Interface Property Testing
Filter
Showing 151–180 of 741 results
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Compliance | ASTM D971, IEC 62961 |
| Density Measurement Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Sample Stage Speed | 0.01–500 mm/min |
| Positional Accuracy | ±0.26 µm |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −20 to +200 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Weight | 11 kg |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 320 mm |
| Maximum Sample Size (L×W×H) | 763 × 230 × 435 mm |
| Stage Load Capacity | 26 kg |
| Imaging System | USB 3.0 Digital Camera with 8× Zoom, High-Intensity Monochromatic LED Illumination |
| Image Resolution | 1936 × 1216 (optional Theta Flow high-speed camera available) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow with 3D Topography Module |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited (L) × 100 mm (W) × 320 mm (D) |
| Max Sample Size | Unlimited (L) × 320 mm (W) × 22 mm (H) |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow HPC High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited × 100 mm × 320 mm |
| Maximum Sample Size | 765 mm × 230 mm × 435 mm |
| Stage Load Capacity | 29 kg |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Pressure Control | Automated via integrated precision pump |
| Temperature Range | Ambient to elevated temperatures (optional sub-ambient cooling available) |
| Chamber Design | Piston-driven high-pressure cell with corrosion-resistant wetted materials (e.g., Hastelloy C-276, sapphire windows) |
| Fluid Handling | Dual-path intelligent injection valve for direct syringe-based dispensing and in-line cleaning without pump priming |
| Surface Activity Preservation | Piston displacement maintains constant bulk-phase surfactant concentration during pressure ramping |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow |
| Instrument Type | Benchtop Dynamic Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Imaging System | USB 3.0 Digital Camera with 8× Optical Zoom & High-Power Monochromatic LED Illumination |
| Sample Stage Dimensions | 765 mm × 230 mm × 435 mm (W × D × H) |
| Maximum Sample Weight | 29 kg |
| Environmental Monitoring | Integrated Temperature & Humidity Sensors |
| Software Platform | OneAttension v4.x with Audit Trail, CFR 21 Part 11 Compliance Options |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | Contact angle, surface tension, interfacial tension, surface free energy |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Sizes | 2", 3", 4", 5", 6", 8", 12" wafers |
| Image Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (derived via pendant/sessile drop analysis) |
| Maximum Sample Diameter | 12-inch silicon wafer |
| Stage Load Capacity | 500 g |
| Automated Functions | Motorized XYZ translation + programmable rotation (0–360°), four independent software-controlled dispensers with disposable tips |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-precision mode) |
| Surface & Interfacial Tension Range | 0.01–2000 mN/m |
| Surface & Interfacial Tension Accuracy | ±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode) |
| Camera Resolution | 1936 × 1216 pixels |
| Sample Stage Dimensions (L×W×H) | 495 × 130 × 310 mm |
| Max. Sample Weight Capacity | 5 kg |
| Image Magnification | Fixed optical path with high-magnification telecentric lens system |
| Measurement Modes | Static CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA |
| Software | OneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | BOROSA |
|---|---|
| Origin | Germany |
| Model | L 800 |
| Operating Temperature Range | −20 °C to 200 °C |
| Maximum Pressure | 75 MPa (optional) |
| Compliance | DIN 55660-3 |
| Chamber Material | Titanium Alloy |
| Window Material | Sapphire |
| Measurement Principle | Pendant Drop Method |
| Pressure Range (Standard) | 0.1–20 MPa |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CETR-UMT |
| Instrument Type | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 75 mm |
| Effective Load Range | 1 mN to 1000 N |
| Load Resolution | 1 µN |
| Displacement Range | ±75 mm |
| Displacement Resolution | 0.1 nm |
| Maximum Friction Force | 1000 N |
| Indenter Types | Conical, Berkovich, Spherical, Cube-Corner, Flat Punch, Custom Tips |
| Thermal Drift | <0.1 nm/min (at 25 °C, stabilized) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GEST-20042F |
| Compliance | GB/T 20042.6–2011, GB/T 20042.7–2014 |
| Measurement Modes | Through-plane (2-probe) & In-plane (4-probe) |
| Electrode Diameter | 50 mm gold-plated |
| Control Interface | 10-inch industrial touchscreen HMI |
| Loading Actuation | Servo-motor-driven precision force application |
| Data Output | Real-time pressure, compressive strain, voltage, current, resistance, resistivity (mΩ·cm, Ω·cm, kΩ·cm), conductivity (S/cm, S/m) |
| Test Protocols | Constant-force, constant-pressure, stepwise gradient (force/pressure/strain), compression-ratio control |
| Data Export | CSV via USB |
| Auto-reset | Yes |
| Reporting | On-screen preview + thermal printout |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KF10 |
| Price Range | ¥49,800–¥60,000 CNY |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.10 mN/m |
| Accuracy | ±0.5 mN/m |
| Temperature Display Range | −40 to 460 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PI 95 |
| Instrument Type | Integrated Nanoindentation and Scratch Tester |
| Compatibility | JEOL, FEI (Thermo Fisher), Hitachi, Zeiss TEMs (excludes UHR pole-piece configurations) |
| Core Functionality | In-situ TEM-compatible nanomechanical, thermal, and electrical property characterization |
| Brand | Bruker |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Hysitron TS 77 Select Nanoindenter |
| Instrument Type | Nanoindenter |
| Maximum Indentation Depth | µm |
| Effective Load Range | 100 nN – 10 mN |
| Load Resolution | <1 nN |
| Displacement Range | 1 nm – 10 µm |
| Displacement Resolution | <0.05 nm |
| Maximum Friction Force | 10 mN |
| Indenter Tip Geometry | Berkovich (triangular pyramid), Cube-corner, Flat-punch, and Custom trapezoidal tips |
| Thermal Drift | <0.05 nm/s |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Hysitron TS 77 Select™ |
| Instrument Type | Nanoindentation and Scratch Tester |
| Compliance Standards | ISO 14577, ASTM E2546 |
| Core Technologies | Capacitive Transducer-Based Force/Displacement Sensing, Electrostatic Actuation, In Situ SPM Imaging |
| Automation Features | Auto-calibration, Multi-sample Sequential Testing, Preloaded Standard Test Protocols |
| Software Platform | Hysitron Insight™ (FDA 21 CFR Part 11–compliant audit trail, GLP/GMP-ready data management) |
| Form Factor | Benchtop |
| Application Scope | Quantitative nanoscale mechanical property mapping, tribological behavior analysis, and structure–property correlation at sub-100 nm resolution |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PI 89 |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TI 980 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Key Technology | Three-Plate Capacitive Transduction |
| Compliance | ASTM E2546, ISO 14577, ISO 20503, USP <1062> |
| Optional Modules | High-Temperature Stage, Electrical Characterization Module, Humidity Control Chamber, Cryogenic Stage, Raman Coupling Interface |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TI 980 |
| Price Range | USD $260,000 – $390,000 |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | TI 990 |
| Drive Technology | Electrostatic actuation |
| Noise Floor | <0.1 nm RMS displacement noise |
| Maximum Load Resolution | 50 nN |
| Depth Resolution | <0.01 nm |
| Active Vibration Isolation | Integrated pneumatic + electromagnetic hybrid system |
| Platform | Precision granite base with environmental enclosure |
| Control Architecture | Performech III dual-lock-in parallel processing module |
| Software Platform | Tribo iQ v4.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready reporting) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TI Premier II |
| Instrument Type | Nanoindentation and Scratch Tester |
| Measurement Principle | Capacitive Displacement Sensing with Electromechanical Actuation |
| Compliance Framework | ASTM E2546, ISO 14577, ISO 20519, USP <1062>, GLP/GMP-Ready Data Integrity Architecture |
| Brand | CDJX |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-5 |
| Instrument Category | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic (Flow) Method |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.0005 m²/g to no upper limit |
| Repeatability | ≥99% |
| Calibration Standard | Certified Reference Materials per ISO 9277 & GB/T 19587–2004 |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Adsorptive Gas | Ultra-High-Purity Nitrogen (≥99.999%) |
| Sample Tube Material | Borosilicate Glass (GG-17 U-tube) |
| Typical Analysis Time per Sample | 5–7 min |
| Operating System Compatibility | Windows XP / Windows 7 / Windows 10 |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Dimensions (L×W×H) | 700 × 300 × 600 mm |
| Software Features | Real-time data visualization, comparative analysis tools, audit-ready result export (CSV/PDF), GLP-compliant reporting templates |
| Brand | CEAJIN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China-made) |
| Model | CEL-SPS1000 |
| Price | USD 49,800 (FOB Beijing) |
| Brand | CEAULIGHT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEL-TPV355 |
| Price | USD 14,200 (FOB Beijing) |
| Laser Source | Nd:YAG, 355 nm, 6 ns pulse width, 1–20 Hz repetition rate |
| Detection Bandwidth | DC–350 MHz (preamp), 500 MHz (oscilloscope) |
| Temporal Resolution | <1 ns (system-limited) |
| Sample Configurations | Powder (sandwich cell), Thin-film/FTO-based devices (liquid-phase or solid-state), Nanomaterials |
| Data Acquisition | Real-time dual-channel synchronous capture with hardware/software noise suppression |
| Compliance | Designed for GLP-compliant labs |
| Brand | Chemplex |
|---|---|
| Origin | USA |
| Product Type | XRF Sample Support Films |
| Model | 100 |
| Thickness | 2.5 µm |
| Format | Roll (3.0" × 300') |
| Material | Mylar® Polyester Film |
| Compliance | ASTM E1361, ISO 8596, USP <233> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DCA400 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Surface/Interfacial Tension Accuracy | ±0.02 mN/m |
| Measurement Method | Wilhelmy Plate Method |
| Tension Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Maximum Sample Load | ≤110 g |
| Density Measurement Range (with optional accessories) | 0.5–2.25 g/cm³ |
| Density Readability/Repeatability | ±0.00005 g/cm³ |
| Power Supply | 230 V (−15% / +10%), 50 Hz, 10 VA |
| Dimensions (W × D × H) | 210 × 370 × 380 mm |
| Weight | 8 kg |
| Standard Accessories | Manual-adjustable motorized Z-stage, custom borosilicate glass plate (24 × 24 × 0.15 mm), platinum-iridium Wilhelmy plate, glass measurement beaker, temperature-controlled jacketed cup (optional), Du Noüy ring kit (optional) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TW 7400 |
| Pricing | Upon Request |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | JB-2020 |
| Instrument Type | Specific Surface Area Analyzer |
| Principle | Dynamic (Flow-through) Nitrogen Adsorption |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Pressure Control Range | 1–5 kPa (gauge) |
| Theoretical Basis | Dynamic nitrogen adsorption coupled with cryogenic adsorption thermodynamics and gas chromatographic response calibration |
| Operating Ambient Temperature | 10–36 °C |
| Repeatability Error | ≤ ±3% |
| Accuracy Error | ≤ ±3% |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type, U-shaped) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Ultra-high-purity nitrogen (≥99.999%) |
| Software Compatibility | Windows 7 / Windows 10 (32/64-bit) |
| Dimensions (W×D×H) | 700 × 360 × 710 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Environmental Requirements | 5–35 °C ambient temperature |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-2020 |
| Instrument Category | Specific Surface Area Analyzer |
| Operating Principle | Dynamic (Flow) Nitrogen Adsorption at Cryogenic Temperature |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited upper bound |
| Pressure Control Range | 1–5 kPa (gauge) |
| Theoretical Basis | Dynamic nitrogen adsorption coupled with thermal desorption detection and calibrated gas chromatographic response |
| Calibration Standards | GBW(E)130275 certified reference material (CRM), compliant with GB/T 19587–2017 |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type), U-shaped configuration |
| Repeatability | ≤ ±3% RSD |
| Accuracy | ≤ ±3% (vs. certified CRM) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Liquid-nitrogen-cooled high-purity nitrogen (≥99.999%) |
| Test Duration per Sample | ~3 minutes |
| Software Platform | Windows 10 / Windows 7 compatible |
| Dimensions | 700 mm × 360 mm × 710 mm (W × D × H) |
| Net Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Ambient Requirements | 5–35 °C, RH <85% non-condensing |
| Detection System | Low-temperature, high-sensitivity thermal conductivity detector (TCD) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JB-2020 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Low-Temperature Nitrogen Adsorption) |
| Number of Analysis Stations | 1 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Pressure Range | 1–5 kPa (gauge) |
| Test Theory | Dynamic nitrogen adsorption at 77 K using helium carrier gas and pulsed nitrogen dosing, based on chromatographic response integration |
| Calibration Standard | GBW(E)130275 certified reference material (CRM) per GB/T 19587–2017 |
| Repeatability Error | ≤ ±3% |
| Accuracy Error | ≤ ±3% |
| Sample Tube Material | High-temperature-resistant borosilicate glass (GG-type U-tube) |
| Carrier Gas | Ultra-high-purity helium (≥99.999%) |
| Adsorbate Gas | Ultra-high-purity nitrogen (≥99.999%) |
| Software Compatibility | Windows 7 / Windows 10 (32/64-bit) |
| Dimensions | 700 mm × 360 mm × 710 mm (W×D×H) |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% non-condensing |
| Analysis Time per Sample | ~3 minutes (single-point or multi-point BET) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic Instrument |
| Model | JB-5 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Chromatography-Based) |
| Measurement Range | 0.0005 m²/g to unlimited |
| Theoretical Basis | BET Theory via Low-Temperature Nitrogen Adsorption (Dynamic Chromatographic Mode) |
| Repeatability | >99% |