Surface & Interface Property Testing
Filter
Showing 181–210 of 741 results
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JB-5 Series |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Low-Temperature Nitrogen Adsorption with Helium Carrier Gas) |
| Number of Analysis Stations | 4 |
| Measurement Range | 0.0005 m²/g to unlimited |
| Calibration Standard | ISO 9277 & GB/T 19587–2004 |
| Accuracy | ≤ ±1% (verified using certified reference materials) |
| Sample Tube Material | High-Temperature-Resistant GG Glass U-Tube |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Adsorbate Gas | Ultra-High-Purity Nitrogen (≥99.999%) |
| Test Modes | Single-Point, Multi-Point BET, Comparative Analysis |
| Cycle Time per Sample | 5–7 minutes |
| Software Platform | Windows XP/7/10 Compatible |
| Dimensions (L×W×H) | 700 × 300 × 600 mm |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JB-50 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow (Carrier Gas Chromatographic) Method |
| Measurement Range | 0.0005 m²/g to unlimited |
| Theoretical Basis | Gas Adsorption BET Theory with Gaseous Chromatography Detection |
| Repeatability | >99% |
| Standards Compliance | ISO 9277, GB/T 19587–2017 |
| Sample Throughput | 4 independent stations |
| Analysis Time per Sample | 5–7 minutes |
| Calibration | Certified Reference Materials (e.g., NIST-traceable SiO₂ or α-Al₂O₃) |
| Detector | Low-Temperature High-Sensitivity Thermal Conductivity Detector (TCD) |
| Carrier Gas | Ultra-High-Purity Helium (≥99.999%) |
| Adsorbate | Ultra-High-Purity Nitrogen (≥99.999%) |
| Sample Tube | U-shaped GG-glass (borosilicate), high-temp resistant |
| Cryogenic System | 500 mL Dewar flask with vacuum-insulated double-wall glass |
| Flow Control | Precision Mass Flow Regulators & Pressure-Stabilized Valves |
| Software | Windows XP/7/10 compatible |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Specific Surface Area Analyzer |
| Principle | Dynamic Flow Method (Low-Temperature Nitrogen Adsorption) |
| Analysis Stations | 1 |
| Measurement Range | 0.1–3500 m²/g |
| Pressure Control Range | 1–5 (arbitrary unit, calibrated via standard gas pulses) |
| Theoretical Basis | BET Theory |
| Repeatability | ≤ ±3% |
| Sample Tube Material | High-Temperature-Resistant GG Glass (U-Shaped) |
| Calibration Standard | GBW(E)130275 Certified Reference Material |
| Test Gases | Ultra-High-Purity Helium (carrier) and Nitrogen (adsorbate) |
| Software Compatibility | Windows 7 / Windows 10 |
| Dimensions | 700 × 360 × 710 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% |
| Test Duration per Sample | ~3 minutes |
| Data Output | Exportable reports with storage, query, comparison, editing, and deletion functions |
| Measurement Modes | Single-Point, Multi-Point BET, Comparative Analysis |
| Brand | CIQTEK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | H-Sorb 4600 |
| Measurement Method | Static Volumetric Method |
| Temperature Range | –196 °C to 350 °C (standard heating jacket |
| Pressure Range | Ultra-High Vacuum (≤5×10⁻⁶ Pa with extended molecular pump) to 200 bar |
| Sample Tube Material | Electropolished 316L Stainless Steel with Micro-Welded Construction |
| Sealing | VCR Metal-to-Metal Face Seal |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Costech KELVIN Sorptometer 1042 |
| Quotation | Upon Request |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | DIPP-Strain |
| Type | Standalone DIC Software (2D & 3D) |
| Supported Configurations | Single-camera 2D DIC, Dual-/Multi-camera Stereo DIC |
| Input Formats | AVI, WMV, MPEG, CINE, JPEG, BMP, GIF, TIFF, PNG |
| Output Formats | AVI, WMV, MP4, JPEG, BMP, PNG |
| Key Results | 2D — εₓ, εᵧ, γₓᵧ, ε₁ |
| OS | Windows 10/11 Home or Pro (64-bit) |
| CPU | Intel Core i5 or higher (multi-core) |
| RAM | ≥8 GB |
| HDD | ≥10 GB free space |
| Display | ≥1920×1080 resolution |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSA100 |
| Price Range | USD 68,000 – 136,000 |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 100 × 100 mm (adjustable height) |
| Optical Magnification | 0.7–4.5× (motorized zoom lens) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Temperature Control Range | −30 to +400 °C (with optional thermostatted stages) |
| Humidity Control | Integrated chamber (10–95% RH, ±2% RH stability) |
| Imaging System | High-speed monochrome CMOS camera (1024 × 1024 px, 12-bit dynamic range, up to 300 fps) |
| Software Platform | ADVANCE v4.x with audit trail, user management, and 21 CFR Part 11 compliance modules |
| Brand | Ducom |
|---|---|
| Origin | USA |
| Model | TR-101 |
| Instrument Type | (Micro/Nano) Scratch Tester |
| Maximum Indentation Depth | 5 mm |
| Effective Normal Load Range | 10 mN – 200 N |
| Load Resolution | 1 µN |
| Displacement Range | 0.1 mm – 50 mm |
| Displacement Resolution | 1 µm |
| Maximum Friction Force | 200 N |
| Indenter Tip | Rockwell C Diamond Tip |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DVS Adventure |
| Instrument Type | Dynamic Vapor Sorption Analyzer |
| Mass Resolution | ±0.01 µg |
| Temperature Range | 5–85 °C |
| Relative Humidity Range | 0–98 %RH |
| Sample Mass Capacity | 1 mg to 5000 mg |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software | DVS Insight v5.x with audit trail, method validation support, and 21 CFR Part 11 optional modules |
| Brand | EMTEC |
|---|---|
| Origin | Germany |
| Model | emtec PDA.C 02 with WSD 02 Module |
| Power Supply | 230 V, 50 Hz / 115 V, 60 Hz |
| Sample Dimensions | ≥210 mm × (60 ± 0.5) mm |
| Instrument Weight | 8.5 kg |
| Measurement Resolution | ±0.013% strain |
| Reproducibility | ±0.05% absolute strain (0–3% range), ±5% relative error at low elongation |
| Time Resolution | Starts recording from first contact (t = 0 ms), data capture interval ≤100 ms |
| Max. Measurable Wet Expansion | 25% |
| Compliance | Designed for ISO 12625-9, TAPPI T 492 om-22, and ASTM D726-15 aligned test protocols |
| Brand | KRÜSS |
|---|---|
| Origin | Germany |
| Model | BPT Mobile |
| Surface Tension Range | 10–100 mN/m |
| Resolution | 0.1 mN/m |
| Surface Age Range | 10–30,000 ms |
| Temperature Measurement Range | 0–100 °C |
| Display | 5-inch IPS touchscreen (480 × 854 px) |
| Battery Life | Up to 10 hours |
| Dimensions (W × D × H) | 85 × 55 × 220 mm |
| Weight (without accessories) | 600 g |
| Measurement Principle | Bubble Pressure Method |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-20042I |
| Price | USD 1,550 (FOB Beijing) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | JC2000D |
| Pricing | Upon Request |
| Stage | Manual or Motorized 3-Axis Sample Stage |
| Dispenser | Manual Precision Syringe System (10 µL / 100 µL) |
| Camera | USB 2.0 Industrial CCD, 700 TV Lines, 25 fps |
| Optical Zoom | 0.7×–4.5× Continuous Zoom Lens (with Post-Zoom Magnification |
| Effective Pixel Resolution | 50–318 px/mm) |
| Light Source | Adjustable Monochromatic LED Cold Light |
| Tilt Platform | ±15° Manual Sample Tilting Stage (Optional) |
| Rotation Platforms | 360° Vertical & Horizontal Rotational Stages (Optional) |
| Heating Stage | Ambient to 100 °C (Optional) |
| Accessories | Fiber Holder, Fabric Stretch Frame, Insertion Plate, Sessile Drop Arrest Device (All Optional) |
| Brand | FemtoTools |
|---|---|
| Origin | Switzerland |
| Model | FT-G Series Nanotweezers (FT-G30, FT-G60, FT-G100) |
| Compatible Systems | FT-GS1000 Micro-Nano Assembler, FT-GS5000 Nano Assembly System |
| Controller | FT-GC01 Nanotweezer Controller |
| Operating Environments | Ambient air, liquid, and high vacuum (SEM-compatible) |
| Force Feedback | Integrated capacitive force sensor (FT-G30 & FT-G100) |
| Displacement Resolution | <1 nm |
| Force Resolution | <100 pN |
| Brand | SHNTI (Distributor) |
|---|---|
| Origin | Switzerland |
| Model Series | FT-RS / FT-FS / FT-S / FT-G / FT-UMS1000 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Effective Load Range | 5 nN – 10 mN |
| Load Resolution | 1 nN |
| Displacement Range | ±100 µm |
| Displacement Resolution | 5 nm |
| Maximum Friction Force | 1 mN |
| Indenter Tip Types | Berkovich, Cube-Corner, Flat Punch, Spherical (customizable) |
| Thermal Drift | <0.1 nm/s (at 25 °C, stabilized environment) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FERITSCOPE FMP30 |
| Measurement Principle | Magnetic Induction (Ferrite-Specific Permeability Detection) |
| Display | Backlit LCD, 128 × 64 pixels |
| Probe Interface | Interchangeable modular probe connector |
| Calibration | Single-point calibration across full measurement range |
| Units | % Fe (ferrite number equivalent) and vol.% Fe |
| Compliance | Designed per ISO 8249:2017, ASTM A802, EN 17068 |
| Operating Temperature | 0 °C to 50 °C |
| IP Rating | IP65 (dust- and water-resistant) |
| Power Supply | Rechargeable Li-ion battery (≥10 h continuous operation) |
| Data Output | USB 2.0, optional Bluetooth 4.2 module |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | HM500 LIGHT |
| Compliance | DIN EN ISO 14577-1, DIN EN ISO 14577-2, DIN 50359 |
| Measurement Principle | Continuous Stiffness Measurement (CSM) & Depth-Sensing Indentation |
| Load Range | 0.1 mN – 500 mN |
| Depth Resolution | ≤ 0.05 nm (50 pm) |
| Load Resolution | ≤ 0.01 mN |
| Indenter Types | Vickers (136° diamond pyramid), Berkovich (115.2° tri-pyramid), spherical WC or diamond |
| Stiffness Measurement Mode | Enhanced Stiffness Profiling (ESP) |
| Data Acquisition Rate | Up to 1 kHz |
| Zero-Point Detection | Capacitive contact sensing with sub-nm repeatability |
| Environmental Stability | Active thermal drift compensation (< 0.05 nm/s) |
| Software Platform | FISCHER FISCHERWIN v8.x (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | HM500 |
| Compliance | DIN EN ISO 14577-1, DIN EN ISO 14577-2, DIN 50359 |
| Measurement Principle | Continuous Stiffness Measurement (CSM) & Depth-Sensing Indentation |
| Load Range | 0.1 mN – 1000 mN |
| Depth Resolution | ≤ 0.05 nm (sub-pm interpolation capability) |
| Load Resolution | ≤ 10 nN |
| Indenter Types | Vickers (136° diamond pyramid), Berkovich (115.2° trihedral pyramid), spherical diamond (R = 1 µm to 100 µm) |
| Stiffness Measurement Mode | Enhanced Stiffness Profiling (ESP) |
| Data Acquisition Rate | Up to 1 kHz |
| Environmental Stability | Active temperature compensation (±0.1 °C) |
| Software Compliance | FDA 21 CFR Part 11 ready, GLP/GMP audit trail enabled |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | ST200 |
| Instrument Type | Micro- and Nano-Scratch Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Normal Load Range | 0.1–200 N |
| Load Resolution | 3.3 µN |
| Displacement Range | 130 mm |
| Displacement Resolution | 0.01 nm |
| Maximum Friction Force | 200 N |
| Indenter Type | Natural Diamond Tip |
| Thermal Drift | ≤0.05 nm/s |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | ST30 |
| Instrument Type | Micro/Nano Scratch Tester |
| Maximum Indentation Depth | 1000 µm |
| Effective Load Range | 0.01–30 N |
| Load Resolution | 0.7 µN |
| Displacement Range | 100 mm |
| Displacement Resolution | 0.01 nm |
| Maximum Friction Force | 50 N |
| Indenter Type | Rockwell Indenter |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | HM2000 |
| Instrument Type | Nanoindentation Tester |
| Max Indentation Depth | 500 µm |
| Effective Load Range | 0.1–2000 mN |
| Load Resolution | 150 nN |
| Displacement Range | 130 mm |
| Displacement Resolution | 0.01 nm |
| Max Friction Force | 50 N |
| Indenter Types | Vickers, Berkovich, Tungsten Carbide Sphere |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | HM2000_S |
| Compliance | DIN EN ISO 14577 |
| Measurement Principle | Instrumented Indentation Testing (IIT) |
| Output Parameters | Martens Hardness (HM), Indentation Hardness (HIT), Indentation Modulus (EIT), Indentation Creep (CIT), Elastic Work Ratio (ηIT = Welast/Wtotal) |
| Enhanced Stiffness Procedure (ESP) | Yes |
| Load Range | Sub-mN to 1 N (typical for micro/nano-scale IIT systems) |
| Depth Resolution | < 0.1 nm |
| Load Resolution | < 1 µN |
| Sample Height Max | ~100 mm |
| XY Stage Travel | 100 × 100 mm (motorized, optional) |
| Brand | Fluigent |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fluigent-EISP |
| Pricing | Contact for Quotation |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | TPC/TPV |
| Sampling Rate | 60 MS/s |
| Time Resolution | 18 ns |
| Frequency Range | 10 mHz – 10 MHz |
| Current Resolution | <100 pA |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (optional cryo/heating stage) | −120 °C to +150 °C |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | TMIX |
| Light Source | 880 nm NIR LED |
| Measurement Principle | Multiple Light Scattering (MLS) |
| Particle Size Range | 0.05–1000 µm |
| Max. Volume Concentration | 95% v/v |
| Temperature Control Range | RT + 5 °C to 60 °C |
| Scan Height | 55 mm |
| Spatial Resolution | 40 µm |
| Dimensions (W × D × H) | 38 × 42 × 32 cm |
| Sample Capacity | 1 tube per run |
| Data Acquisition Interval | 20 s |
| Compliance | Designed for GLP-compliant stability assessment |
| Brand | FSM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FA-2000 |
| Pricing | Available Upon Request |
| Brand | FSM |
|---|---|
| Origin | USA |
| Model | FSM-413 EC |
| Measurement Principle | Infrared (IR) Interferometric EchoProbe™ Technology |
| Substrate Compatibility | Si, GaAs, InP, SiC, Sapphire, Quartz, Glass, Polymers |
| Configurations | Single-Probe (substrate thickness only) / Dual-Probe (total thickness + topography) |
| Optional Modules | Trench/Through-Silicon Via (TSV) Depth, Film Thickness, Bump Height, Surface Roughness (Rq/Ra), Sidewall Angle |
| Compliance | Designed for ISO 9001-certified semiconductor fabrication environments |
| Brand | FSM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | VIT |
| Pricing | Available Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GearScan 3 |
| Pricing | Upon Request |
| Brand | GFM |
|---|---|
| Country of Origin | Germany |
| Model | 3D Step Height & Surface Defect Profilometer |
| Measurement Principle | Laser Stripe Phase Projection with DSP-Based Real-Time Image Processing |
| Measurement Range (X/Y/Z) | 13 × 8 × 5 mm |
| Measurement Uncertainty | (2 + L/1000) µm (L in µm) |
| Vertical Resolution | 1 µm |
| Working Distance | 107 mm |
| Scan Time per Frame | 3 s |
| Point Cloud Density | 360,000 points/frame |
| Operating Temperature | 5–40 °C |
| Light Source | Blue LED |
| Optical Path | High-Angle Illumination Design |
| Software | Dedicated Scratch & Step Analysis Suite with Polynomial/Gaussian/Mean Filtering |