Surface & Interface Property Testing
Filter
Showing 181–203 of 203 results
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | SMT-2000 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Compliance Standards | ASTM E2546, ASTM B933, ASTM D785, ASTM E140, ISO 14577, ISO 6508, ISO 6507, ISO 4516, DIN 50359, DIN 55676, JIS B7734 |
| Actuation | Piezoelectric ceramic drive |
| Sensing Technology | Capacitive displacement sensing |
| Load Range | Nanonewton to 10 N (full-scale) |
| Vertical Resolution | Sub-nanometer |
| Lateral Sample Dimensions | Up to 500 mm × 500 mm |
| Maximum Sample Weight | 10 kg |
| Tip Options | Berkovich, Vickers, spherical, cube-corner, Knoop |
| In-situ 3D topography mapping | Yes |
| Active vibration isolation | Integrated platform |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | SMT-5000 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 500 µm |
| Effective Load Range | 0.1–200 N |
| Load Resolution | 0.1 N |
| Displacement Range | 100 mm |
| Displacement Resolution | 1 nm |
| Maximum Friction Force | 100 N |
| Indenter Type | Diamond |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | Infrasorb |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic (Flow) Method |
| Number of Analysis Stations | 12 |
| Pressure Range | Ambient (1 bar) |
| Measurement Gas | n-Butane, CO₂ (optional: NH₃, H₂S, VOCs e.g., methanol, ethanol) |
| Sample Volume | 0.1 mL or ≤30 mg |
| Gas Flow Rate | up to 500 mL/min (N₂-equivalent) |
| Analysis Time | <5 min (typ. 3 min) |
| Temperature | 298 K |
| Detection Method | Non-contact, disturbance-free infrared thermography |
| Repeatability | High (validated per ISO 9277 and ASTM D3663 protocols for comparative adsorption screening) |
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | RuboSORP 50 / 150 / 350 / 700 |
| Measurement Principle | Magnetic Suspension Balance (Gravimetric) |
| Temperature Range | −196 °C to 500 °C |
| Pressure Range | 0–700 bar |
| Ultimate Vacuum | 1 × 10⁻⁷ mbar |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SCI300C2 |
| Price Range | USD 14,000 – 28,500 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate (ISO 6295, ASTM D971) |
| Trough Material | PTFE (fully fluorinated) |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upstroke & Downstroke |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temp. | Ambient (compatible with external thermostatic bath) |
| RH Range | 30–85% |
| Optional Configurations | Dual-trough, multi-trough, or custom-area troughs |
| Brand | SETARAM |
|---|---|
| Origin | USA |
| Model | PCT Pro E&E |
| Instrument Type | Physical & Chemical Sorption Analyzer |
| Temperature Range | –269 °C to 500 °C |
| Pressure Range | Vacuum to 200 bar |
| Pressure Accuracy | ±1% FS |
| Detection Limit | 3 µg (equivalent to 0.3 wt% gas uptake on 1 mg sample) |
| Integrated Pressure Sensors | 4 (auto-switching dual-range) |
| Gas Compatibility | H₂, CO₂, CH₄, NH₃ |
| Sample Cell Options | 6 types (standard, high-temp, liquid, thin-film, cryogenic, micro-dosing) |
| Safety Systems | Combustible gas detection, multi-point T/P monitoring, inert-gas purged transfer pathway |
| Software Platform | LabVIEW-based with real-time data acquisition, automated sequence execution, and audit-trail-capable operation |
| Brand | Setaram |
|---|---|
| Origin | USA |
| Model | PCTPro-Evo |
| Temperature Range | –269 °C to 500 °C |
| Pressure Range | Vacuum to 200 bar |
| Pressure Accuracy | ±1% |
| Detection Limit | 3 µg (equivalent to 0.3 wt% gas uptake on 1 mg sample) |
| Gas Compatibility | H₂ only |
| Sensor Configuration | Four auto-switching pressure transducers with dual-range capability |
| Sample Cell Options | Six interchangeable cells (standard, high-temperature, liquid, thin-film, cryogenic, micro-dosing) |
| Safety Systems | Integrated combustible gas detection, multi-point temperature/pressure monitoring, inert-gas purged transfer pathway |
| Software Platform | LabVIEW-based real-time control and analysis suite |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Shengtai Instruments Co., Ltd. |
| Model | SH107 |
| Measurement Range | 2–200 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Accuracy | ±0.1 °C |
| Test Method | Du Noüy Ring Method (GB/T 6541) |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤80% RH |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Power Consumption | 20 VA |
| Dimensions (L×W×H) | 185 × 290 × 360 mm |
| Weight | 15 kg |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SH126 |
| Applicable Standards | GB/T 12579, ASTM D892, JIS K2518 |
| Temperature Control Range | 0 °C to 99.9 °C |
| Temperature Accuracy | ±0.5 °C |
| Low-Temp Bath Setting | 24 °C ±0.5 °C |
| High-Temp Bath Setting | 93.5 °C ±0.5 °C |
| Air Flow Rate | 16–160 mL/min (adjustable via rotameter) |
| Built-in Air Source | 3 L/min |
| Gas Diffuser Capacity | 3000–6000 mL/min at 2.45 kPa |
| Timer Range | 0–99.99 h |
| Timer Accuracy | ±1 s |
| Sample Cylinder | 1000 mL calibrated glass cylinder (dedicated) |
| Dimensions | 680 × 380 × 550 mm |
| Weight | 35 kg |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DVS Discovery |
| Instrument Type | Dynamic Vapor Sorption Analyzer |
| Temperature Range | 10–70 °C |
| Brand | Spectro Scientific |
|---|---|
| Model | InfraCal 2 |
| Origin | USA |
| Detection Principle | Infrared Absorption (C–H Stretch Band at ~2960 cm⁻¹) |
| Compliance | ASTM D7066 (Transmission Method), EPA Method 1664 (Reflectance Mode Equivalent) |
| Power | Rechargeable Lithium-ion Battery |
| Interface | Touchscreen Display |
| Calibration | Multi-curve Internal Library |
| Data Management | Onboard Storage & USB Export |
| Security | Password-Protected User Settings & Calibration Curves |
| Alarm | Configurable Threshold Alerts |
| Environmental Rating | Industrial-Grade Enclosure for Workshop & Cleanroom-Adjacent Use |
| Brand | Starwood |
|---|---|
| Model | SDW-18CS |
| Type | Research-Grade Fully Automated Optical Contact Angle Analyzer |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Power Supply | 220 V, 50–60 Hz |
| Power Consumption | 10 W |
| Dimensions (W × L × H) | 655 × 180 × 520 mm |
| Weight | ~16 kg |
| Sample Stage Travel (X/Y/Z) | 30/50/30 mm (manual, 0.1 mm resolution) |
| Leveling | Full-system + camera-level XY precision leveling (included professional-grade XY level) |
| Sample Platform Size | 130 × 150 mm (customizable) |
| Max Sample Size | 200 (W) × ∞ (L) × 30 (H) mm |
| Dispensing System Y/Z Travel | 40/35 mm (0.1 mm resolution) |
| Dropping Stroke | 60 mm (0.01 mm resolution) |
| Droplet Volume Precision | 0.01 µL |
| Syringe Capacity | 500 µL (auto liquid-level detection) |
| Standard Needles | 0.5 mm stainless steel (20 pcs), 0.25 mm superhydrophobic needle (20 pcs) |
| Camera | Japan Sony industrial-grade CMOS (Onsemi global shutter), 1/1.8″ progressive scan, 1280 × 1024 resolution |
| Lens Magnification | 0.7×–4.5×, focus adjustment ±2.5 mm |
| Max Frame Rate | 80 fps |
| Light Source | US-sourced industrial white cold LED (400–760 nm), quartz diffuser for uniform illumination, 50,000 h lifetime, PWM + software brightness control |
| Contact Angle Methods | Sessile drop, pendant drop, captive bubble, tilting plate (dynamic) |
| Static CA Fitting Algorithms | Circle, Oblique Circle, Ellipse, Oblique Ellipse, B-Snake, concave/convex surface fitting |
| Dynamic CA Analysis | Advancing, receding, hysteresis angles (batch image & video-based analysis) |
| Baseline Detection | Auto/manual |
| Angular Range | 0° < θ < 180° |
| Angular Accuracy | ±0.1° |
| Angular Resolution | 0.001° |
| Surface Energy Models | Fowkes, OWRK, Zisman, EOS, Acid-Base Theory, Wu Harmonic Mean, Extended Fowkes (37 preloaded liquids |
| Surface Tension Range | 0.1–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Work of Adhesion / Spreading Coefficient / Adhesion Tension | Auto-calculated, resolution 0.001 mN/m |
| Software | CA V2.0 (static/dynamic CA + surface energy + interfacial tension modules) |
| OS Requirement | Windows 10 (64-bit) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super-Pig |
| Pricing | Upon Request |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DVS Adventure |
| Temperature Range | 5–85 °C |
| Relative Humidity Range | 0–98% RH |
| Sample Mass Capacity | 1–5000 mg |
| In-situ Heating/Drying Capability | up to 300 °C |
| Humidity Generation Method | Dual-gas mixing (dry carrier gas + saturated vapor) with digital mass flow control |
| Compatibility | Raman spectroscopy (via optical fiber), color video microscopy, NIR spectroscopy |
| Modularity | Upgradable to organic vapor sorption |
| Construction | Anti-static stainless steel |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Spec&Scan 2000 |
| Pricing | Upon Request |
| Brand | Teclis Scientific (France) |
|---|---|
| Origin | France |
| Model | FOAMSCAN |
| Gas Flow Range | 20–500 mL/min (mass flow controlled) |
| Stirring Speed | 500–6000 rpm (software-controlled) |
| Temperature Measurement | Pt100 sensor (ambient or optional water bath coupling) |
| Dual-Camera Imaging System | Primary foam height + secondary bubble structure |
| Modular Foaming Methods | Gas injection (via sintered glass frit), Mechanical stirring, External foam introduction |
| Automated Cleaning System | Dual-fluid (water + optional cleaning agent), integrated waste pump |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TIAST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TI-DZ Series |
| Pricing | Available Upon Request |
| Measurement Current Options | 3 A, 5 A, 15 A (user-configurable) |
| Channel Capacity | Multi-channel, Group-assignable |
| Data Interface | RS232/RS485/Ethernet (protocol provided upon request) |
| Software | Proprietary Windows-based Control & Analysis Suite |
| Environmental Integration | Compatible with climate chambers (temperature/humidity logging, time-scheduled testing, alarm monitoring) |
| Compliance Support | GLP-compliant audit trail (optional), ISO/IEC 17025 traceability-ready |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | PSM-165 |
| Measurement Principle | Capillary Flow Porometry (CFP) |
| Pore Size Range | 0.25–130 µm |
| Max Test Pressure | 6 bar |
| Operating Fluid | TOPOR® wetting liquid (custom-formulated fluorinated inert fluid) |
| Power Supply | 110–230 V AC |
| Dimensions (W×H×D) | 480 × 390 × 310 mm |
| Weight | 12 kg |
| Compliance | ASTM E1294-89, ASTM F316-03 |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-1510 |
| Measurement Range | 2–200 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–40 °C |
| Temperature Display Precision | ±0.1 °C |
| Measurement Method | Du Noüy Ring Method |
| Repeatability | ≤0.2% RSD |
| Power Consumption | ≤20 W |
| Operating Environment | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 270 × 185 × 360 mm |
| Weight | 7.5 kg |
| Compliance Standard | GB/T 6541 (Petroleum Products — Determination of Interfacial Tension Between Oil and Water — Du Noüy Ring Method) |
| Brand | YDWO (Yidian Woguang) |
|---|---|
| Model | WBL Series |
| Measurement Principle | Static Volumetric Nitrogen Physisorption at 77 K |
| Adsorption Gas | High-Purity N₂ (99.999%), optional He |
| P/P₀ Range | 1×10⁻⁶ to 0.998 |
| Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Size Analysis Range | 0.35–500 nm (3.5–5000 Å) |
| Pressure Sensors | 3–6 × high-accuracy absolute transducers (0–133 kPa, ±0.12% FS) |
| Temperature Sensor | PT-100 (±0.1 °C) |
| Cryostat | 2 L metal Dewar, >80 h hold time |
| Ultimate Vacuum | ≤1.0×10⁻⁴ Torr |
| Vacuum Pump | Imported dual-stage rotary vane pump |
| Sample Capacity | 1–3 stations (model-dependent) |
| Compliance | ISO 9277, ISO 15901, GB/T 119587 |
| Software | Integrated analysis suite for BET, Langmuir, BJH, t-plot, D-A, H-K, NLDFT, GCMC, and true density calculation |
| Output | Printable reports & Excel export (isotherms, surface area, pore volume/area distribution, cumulative metrics) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-600A |
| Measurement Range | 2–500 mN/m |
| Accuracy | ±0.4 mN/m |
| Sensitivity | 0.1 mN/m |
| Detection Method | Du Noüy Ring Method |
| Power Supply | AC 220 V ±5%, 50 Hz ±2.5% |
| Power Consumption | 50 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Temperature Control | PID Auto-Tuning |
| Sample Capacity | 3 positions |
| Display | High-Resolution Color Touchscreen |
| Data Output | Auto-printing & Real-time Dynamic Tension Curve Visualization |
| Calibration | Single-Point Calibration Protocol |
| Brand | ZEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZD-180D Steam Condensation & Fog Removal Unit |
| Instrument Type | Static Vapor Adsorption System |
| Temperature Range | 5–55 °C |
| Humidity Range | 10–99 % RH |
| Humidity Accuracy | ±5 % RH |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GEST-126 |
| Measurement Principle | Four-Probe DC Resistivity Method with Controlled Compaction |
| Compliance Standards | YS/T 587.6–2006, GB/T 24525–2009, GB/T 24521–2009, GB/T 3782–2016 |
| Resistivity Range | 10⁻⁶ – 10⁵ Ω·cm |
| Resolution | 10⁻⁸ Ω·cm |
| Voltage Ranges | 2 mV / 20 mV / 200 mV / 2 V |
| Current Output | 10 μA – 10 A (8 ranges) |
| Electrode Material | High-Purity Copper |
| Inter-Electrode Spacing | 10 mm |
| Powder Compaction Cylinder ID | 16 mm (optional 30 mm) |
| Stroke | 50 mm |
| Loading Capacity | 10 kN |
| Loading Control | Stepper-Motor-Driven Automatic Constant-Load Application |
| Force & Pressure Display | Real-Time Digital Readout |
| Sample Height Measurement | Integrated Linear Encoder |
| Data Output | Volume Resistivity (Ω·cm), Resistance (Ω), Applied Pressure (MPa), Compaction Time (s) |
| Interface | 7-inch Capacitive Touchscreen HMI |
| Data Export | USB Storage |
| Thermal Drift Stability | <0.05% per hour |
| Measurement Repeatability | ±0.3% at fixed density and temperature |