Thermal Analysis Instruments
Filter
Showing 91–120 of 243 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC 2+ |
| Temperature Range | −95 °C to 1,000 °C |
| Heating Rate | 6 K/min to 2,400,000 K/min |
| Cooling Rate | 6 K/min to 240,000 K/min |
| Maximum Heat Flow Signal | 20 mW |
| Heat Flow Noise | < 0.5 µW |
| Sensor Type | UFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side) |
| Measurement Principle | Dynamic power compensation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP82HT / FP84HT |
| Temperature Range | –60 to 375 °C |
| Temperature Repeatability | ±0.2 °C |
| Optical Field of View | Ø2.5 mm (FP82HT), Ø2.0 mm (FP84HT) |
| DSC Sensor | Au–Ni thermopile, 5 thermocouple pairs |
| Calorimetric Sensitivity | 13 mV/mW |
| Sample Environment | Sealed furnace chamber with inert gas compatibility |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP83/HT |
| Temperature Range | –25 to 375 °C |
| Temperature Accuracy | ±0.2 °C |
| Heating Rate | 0.1–20 °C/min |
| Dropping Point Orifice Diameter | 2.8 mm |
| Softening Point Orifice Diameter | 6.35 mm |
| Compliance | ASTM D3104-82, ASTM D3461-85, ASTM D3954, DIN 51920 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP900 |
| Temperature Range | −100 to 600 °C |
| Heating/Cooling Rate | 0–20 °C/min |
| Temperature Resolution | 0.1 °C |
| Sensor Type | PT100 |
| Display | Graphical LCD (60 × 256 pixels, 6 lines × 36 characters) |
| Method Storage | 15 preloaded + 35 user-defined methods |
| Compliance | ASTM, DIN, ISO, USP <741>, GLP/GMP-ready |
| Interface | RS232C |
| Measurement Units Support | °C, °F, K |
| Environmental Operating Range | 20–32 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC 2+ |
| Temperature Range | RT to 500 °C / 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Pressure Range | 0–10 MPa |
| Gas Flow Control | External pressure & mass flow controller supported |
| Atmosphere Compatibility | Inert, oxidizing, reducing, reactive (e.g., N₂, O₂, H₂, CO₂, C₂H₄, CH₃Br), with safety restrictions for combustible/toxic gases |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC1 |
| Temperature Range | 22–500 °C (optional to 700 °C) |
| Heating/Cooling Rate | 0.1–50 °C/min |
| Pressure Range | 0–10 MPa |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Sensor Type | FRS5 (56 thermocouple pairs, star configuration) / HSS8 (120 thermocouple pairs, triple-layer configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HS84 |
| Temperature Range | RT to 375 °C (optional cooling to –90 °C) |
| Heating/Cooling Rate | 0.1–20 K/min |
| Light Aperture | 2 mm |
| Sensor Type | DSC ceramic sensor with 56 thermocouple pairs |
| Sample Carriers | Glass slides, top cover glass, aluminum/glass/sapphire crucibles |
| Crucible Dimensions | Ø6 mm / 40 µL |
| Display | 7″ touch-sensitive VGA color screen |
| Supported Languages | English, German, French, Spanish, Chinese, Japanese, Korean, Russian |
| User Shortcuts | 12 per user |
| Compliance | ASTM F766, EN ISO 3146 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55/80 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 4 °C/min (programmable) |
| Sample Capacity | 6 positions |
| Measurement Modes | Melting Point (MP), Melting Range (MR), Sliding Melting Point (SMP), Boiling Point (BP), Cloud Point (CP) |
| Video Recording Duration | 60 minutes |
| Maximum Results Storage | 50 entries |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ASTM D1565, ISO 4625 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RC1mx |
| Instrument Type | Reaction Calorimeter |
| Temperature Range | −70 °C to 300 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Accuracy | ±0.5 K |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP/GMP-aligned process safety development and regulatory submission support (e.g., ICH Q5, Q9, Q11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1600 |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.5 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-Pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Advanced |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt-Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Standard |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Standard |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02 to 150 K/min / 0.02 to 250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Yes |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1227>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 LF (Large Furnace) / TGA2 SF (Small Furnace) |
| Temperature Range | Up to 1100 °C (LF), Up to 600 °C (SF) |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.001–100 K/min |
| Furnace Type | Dual-furnace modular architecture |
| Compliance | ASTM E1131, ISO 11358, USP <41>, FDA 21 CFR Part 11 ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | 30 °C – 1,100 °C |
| Sampling Rate | 10 data points/second |
| Atmosphere Control | Integrated Mass Flow Controller (MFC) for programmable gas switching |
| Buoyancy Correction | Automatic, model-based, no blank required |
| One-Click Method Launch | Yes |
| Optional Couplings | FTIR, MS, Micro GC, GC/MS |
| Sensor Output | Mass & Temperature |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Application Handbook – Evolved Gas Analysis |
| Compliance | Compatible with TGA-FTIR and TGA-MS coupling configurations per ISO 11358, ASTM E1131, and USP <1031> guidelines |
| Format | Printed and digital PDF (English edition) |
| Intended Use | Method development & interpretation support for thermal decomposition gas-phase characterization |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Distribution Type | Authorized Distributor |
| Product Category | Thermal Analyzer Accessory / Reference Publication |
| Model | Thermal Analysis Application Handbook Series – Thermoplastic Polymers |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Thermal Analysis Application Handbook Series – Thermosetting Resins |
| Price | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Applications Handbook – Elastomers |
| Language | English |
| Format | Printed Book + Digital PDF (upon request) |
| Compliance | Aligned with ISO 11357, ISO 11358, ASTM D3418, ASTM E1356, USP <1159> |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA 2+ IC/600 / LF/1100 / LN/600 |
| Temperature Range | –80 to 600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Range | –0.1 to 1 N |
| Displacement Resolution | 0.5 nm |
| Frequency Range | 0.01–1 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LF/1100, HT/1600, IC600, LN600 |
| Temperature Range | –150 °C to 1600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Resolution | 0.01–1 Hz (dynamic frequency range) |
| Displacement Range | 20 mm |
| Length Resolution | 0.5 nm |
| Operating Modes | Compression, Tension, Penetration, Expansion |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA840, TMA/SDTA841e |
| Temperature Range | −150–600 °C (TMA/SDTA841e), RT–1100 °C (TMA/SDTA840) |
| Temperature Accuracy | ±0.25 °C |
| TMA Resolution | 1 nm (TMA/SDTA841e), 10 nm (TMA/SDTA840) |
| Measurement Modes | Expansion, Penetration, Bending, Tension, Dynamic Load TMA (DLTMA) |
| SDTA Capability | Yes |
| Environmental Control | Hermetic sample chamber |
| Coupling Options | MS, FTIR |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TOPEM™ TMDSC |
| Category | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TT DMA |
| Temperature Range | −190 °C to 600 °C |
| Frequency Range | 0.001 Hz to 1000 Hz |
| Fixture Configurations | Dual-cantilever, single-cantilever, 3-point bending, shear, tension, compression |
| Operating Modes | Creep, constant-force (TMA), stress–strain, stress relaxation, isothermal, step-isothermal, multi-ramp thermal profiles |
| Environmental Options | Humidity chamber (up to 85 °C / 85 % RH), liquid immersion cell, gas purge (N₂, air, Ar) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |