Thermal Analysis Instruments
Filter
Showing 31–60 of 922 results
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | TIM1300 / TIM1400 |
| Test Method | ASTM D5470 |
| Sample Diameter | 1.3 in (33 mm) |
| Thickness Range | 0–20 mm |
| Temperature Range | 20–65°C (TIM1300), 20–130°C (TIM1400) |
| Contact Pressure Range | 5–380 psi (34–2600 kPa) |
| Thickness Measurement Accuracy | ±1% + 0.001 in (±25 µm) |
| Thermal Resistance Range | 0.005–8 K/W |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Cooling Requirement | 6 L/min @ 10–35°C, ±0.1°C stability |
| Compressed Air | ≥90 psi (600 kPa), 10 µm filtration |
| Dimensions (H×W×D) | 58×41×43 cm |
| Weight | 19 kg (TIM1300), 21 kg (TIM1400) |
| Brand | ANALYSIS TECH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | TIMTester 1300, TIMTester 1400 |
| Pricing | Upon Request |
| Brand | AnalysisTech |
|---|---|
| Origin | USA |
| Model | Phase12B |
| Heating Current Capacity | 100 A (max) |
| Max Heating Voltage | 20 V |
| Thermocouple Accuracy | ±0.15°C (typ.), ±0.3°C (max.) |
| Tj Measurement Resolution | ±0.007°C (typ.) |
| Tj Absolute Accuracy | ±0.2–±0.5°C (typ.) |
| Sampling Rate | 1 MHz |
| Dimensions | 17" × 17" × 7.5" H, 25 lb |
| PC Requirements | Windows 7/10 Pro (64-bit), 3 GHz CPU, 2 GB RAM, 500 GB HDD, 4+ USB ports |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Julia DSC 300/500 |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible operation) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | –170 °C to 700 °C |
| Programmable Temperature Control | Dynamic and Isothermal modes |
| Temperature Accuracy | <0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C (peak-to-peak, over 30 min) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Julia DSC |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | < 0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C |
| Control Modes | Dynamic & Isothermal |
| Measurement Principle | Heat-Flux Differential Scanning Calorimetry |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | MCR 703 MultiDrive |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −160 °C to +1000 °C |
| Frequency Range | 2 × 10⁻⁸ Hz to 200 Hz |
| Brand | AOE Tech |
|---|---|
| Origin | Shanghai, China |
| Model | HawkIR 340 |
| Infrared Resolution | 352 × 264 (SR-enhanced to 704 × 528) |
| NETD | ≤30 mK |
| FOV | 25° × 19° (standard) |
| optional lenses | 44° × 34° (0.1 m), 12° × 9° (1.0 m), 7° × 5° (3.0 m) |
| IFOV | 1.24 mrad |
| Focal Length | f/15 |
| Min. Focus Distance | 0.1 m |
| Thermal Range | −20 °C to 650 °C (dual-range: −20–120 °C / 0–650 °C) |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater, at 25 °C ambient) |
| Visible Camera | 13 MP industrial-grade CCD |
| Display | 5″ IPS LCD, 1280 × 720, Gorilla Glass protective cover |
| Frame Rate | 30 Hz |
| Battery | 7.4 V, 3500 mAh Li-ion (≥4 h continuous operation) |
| Weight (excl. lens) | <1.0 kg |
| IP Rating | IP54 |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Compliance | GB 4943.1-2011 / IEC 60950-1, GB/T 2423.5-2019 / IEC 60068-2-27, RoHS Directive |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Upon Request |
| Measurement Range | 0.1–0.8 mm (0.004–0.032 in) |
| Resolution | 0.1 µm |
| Precision | 0.5 µm |
| Brand | ASTR/ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DM3300 |
| Price | USD 3,500 (FOB Shanghai) |
| Measurement Range | 1,000–40,000 kJ/kg |
| Accuracy | Relative Standard Deviation ≤0.2% |
| Temperature Resolution | 0.0001 K |
| Test Duration | ~15 min per sample |
| Power Consumption | ≤60 W |
| Dimensions | 650 mm × 390 mm × 450 mm |
| Operating Ambient | 10–35 °C, RH ≤80%, 220 V ±10% AC |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Model 400 |
| Pricing | Available Upon Request |
| Brand | AYAO Instruments |
|---|---|
| Origin | Hubei, China |
| Model | OPA |
| Type | Optical Power-Based Thermal Dilatometer & Phase Transition Analyzer |
| Measurement Principle | Optical Interferometry (for thermal expansion) + Reflectance Power Monitoring (for phase transition) |
| Sample Form | Free-standing films, substrate-supported thin films, bulk materials |
| Minimum Film Thickness | 1 nm |
| Non-Destructive Testing | Yes |
| Dual-Parameter Output | Coefficient of Thermal Expansion (CTE) and Phase Transition Temperature (e.g., crystallization, melting, glass transition) |
| Compliance Context | Designed for R&D environments requiring traceable, repeatable thermal property data in accordance with ISO 11359 (thermomechanical analysis), ASTM E831 (linear thermal expansion), and GLP-aligned data integrity practices |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1 |
| Temperature Range | 50–320 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.3, 4.5 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.2 °C/min), ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±0.8 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Temperature Resolution | 0.1 °C |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | M-560 / M-565 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.1, 0.2, 0.5, 1, 1.5, 2, 2.5, 3, 5, 10, 20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Dimensions | 80 mm length × 1 mm diameter |
| Sample Capacity | 3 samples for melting point determination (M-565: automated & visual) |
| Temperature Resolution | 0.1 °C |
| Display | 3.5″ color TFT (320 × 240) |
| Heating Time | ~4 min (50 → 350 °C) |
| Cooling Time | ~10 min (350 → 50 °C) |
| Power Consumption | 150 W |
| Certifications | CE, UL |
| Dimensions (W × D × H) | 190 × 200 × 370 mm |
| Weight | 4.5 kg |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP10 |
| Pricing | Available Upon Request |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Trident Film |
| Instrument Type | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Compliance | ISO 22007-2, ASTM D7984, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident HotDisk |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | Better than 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | Better than 1% |
| Standards Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident MTPS |
| Measurement Principle | Modified Transient Plane Source (MTPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | < 1% |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2, ASTM D7984, ASTM D5334, ASTM D5930, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Model | TCi |
| Measurement Principle | Transient Plane Source (TPS) – Multi-Method Platform (MTPS, Flex TPS, Needle TLS) |
| Origin | Canada |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Repeatability | < 1% |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Thermal Diffusivity Range | 0–1200 mm²/s |
| Specific Heat Capacity Range | up to 5 MJ/m³·K |
| Effusivity Range | 5–40,000 W·s⁰·⁵/m²·K |
| Standards Compliance | ASTM D7984, ASTM D5334, ASTM D5930, ISO 22007-2.2, GB/T 32064, IEEE 442 |
| Brand | C-Therm |
|---|---|
| Model | Trident |
| Measurement Principle | Integrated Modified Transient Plane Source (MTPS), Flexible Transient Plane Source (Flex TPS), and Transient Line Source (TLS Needle) |
| Thermal Conductivity Range | 0–2000 W/m·K |
| Accuracy | <5% |
| Repeatability | <1% |
| Operating Temperature Range | –50°C to +500°C |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Compliance | ASTM D7984, ISO 22007-2.2, ASTM D5334, ASTM D5930, IEEE 442, GB/T 32064 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Flex TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Repeatability | < 1% |
| Standards Compliance | ASTM D7984, ISO 22007-2.2, GB/T 32064, ASTM D5334, ASTM D5930, IEEE 442 |
| Brand | C-Therm |
|---|---|
| Origin | Canada |
| Model | Trident TPS |
| Measurement Principle | Transient Plane Source (TPS) |
| Dimensions (L×W×H) | 40 × 40 × 40 cm |
| Accuracy | < 5% |
| Thermal Conductivity Range | 0 – 2000 W/m·K |
| Thermal Diffusivity Range | 0 – 1200 mm²/s |
| Specific Heat Capacity Range | 0 – 5 MJ/m³·K |
| Effusivity Range | 0 – 40,000 W·s⁰·⁵/m²·K |
| Repeatability | < 1% |
| Test Duration | 0.8 – 180 s |
| Compliance | ISO 22007-2:2015, GB/T 32064-2015 |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Trident |
| Price Range | USD 65,000–105,000 |
| Instrument Type | Transient Plane Source (TPS) / Flexible TPS / Transient Line Source (TLS) |
| Dimensions (L×W×H) | 300 × 300 × 212 mm |
| Accuracy | ±1% |
| Thermal Conductivity Range | 0–500 W/(m·K) |
| Repeatability | High |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XRY-1C |
| Measurement Mode | Isoperibol (Constant-Temperature Jacket) |
| Instrument Type | Oxygen Bomb Calorimeter |
| Intelligence Level | Fully Automated with PC Control |
| Temperature Range | 5°C to 35°C |
| Temperature Detection Threshold | 0.001°C – 0.01°C |
| Temperature Resolution | 0.0001°C |
| Temperature Stability | ≤0.001°C per 30 min |
| Temperature Tracking Rate | ~0.01°C/s – 0.05°C/s |
| Single-Sample Test Duration | ~8 min (Standard Mode), ~3 min (Rapid Mode) |
| Bomb Pressure Rating | 20 MPa |
| Pressure Resolution | 0.001 MPa |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M3000 |
| Temperature Range | 30–360 °C |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±0.3 °C (30–200 °C), ±0.5 °C (200–360 °C) |
| Heating Time | ~4.0 min to 300 °C, ~7.5 min to 360 °C |
| Heating Rate | 1 °C/min |
| Sample Positions | 3 |
| Capillary Diameter | 1.4 mm |
| Interface | RS-232 |
| IP Rating | IP20 |
| Power Supply | 90–264 V AC |
| Dimensions | 210 × 360 × 230 mm |
| Weight | 4.3 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Heating Time to 300 °C | 4 min |
| Heating Time to 400 °C | 7.5 min |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Diameter | 1.4 mm |
| Capillary Measurement Port | 1 |
| Interface | RS232 |
| Ingress Protection Rating | IP20 |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Dimensions (L×W×H) | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Brand | Concept |
|---|---|
| Origin | United Kingdom |
| Model | Microscale Combustion Calorimeter |
| Standard | ASTM D7309 |
| Heating Rate Range | 0.2–5 K/s (±5% accuracy) |
| Temperature Range | 0–1000 °C |
| Detection Limit | 5 mW |
| Repeatability | ±2% (for 5 mg sample) |
| Oxygen Measurement | Paramagnetic sensor, 0–100% O₂, accuracy ±0.1% |
| Gas Flow Control | High-precision mass flow controllers for N₂ (80 cm³/min, max 100 cm³/min) and O₂ (20 cm³/min, max 50 cm³/min) |
| Sample Mass Range | 0.5–10 mg |
| Furnace | 10 mm alumina tube with dual Kanthal heating elements |
| Power Supply | 230 V AC, 50 Hz, 10 A |
| Dimensions (W×H×D) | 600 mm × 1025 mm × 500 mm |
| Weight | 42 kg |
| Operating Ambient | 10–35 °C |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Model | AURORA |
| Construction | Monolithic Aluminum Extrusion with Integrated NEOcore Phase-Change Thermal Channel |
| Thermal Load Capacity | Up to Multi-kilowatt Passive Dissipation |
| Mounting Flexibility | Horizontal or Vertical Integration |
| Compliance | Designed for ISO 9001–certified manufacturing |
| Certifications | CE-marked for industrial equipment integration |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Model | COMET |
| Core Technology | NEOcore® Integrated Heat Channel |
| Max Power Handling | 840 W (COMET Matrix configuration) |
| Material | High-Purity Aluminum |
| Working Fluid | Water-based Hydroxide Compound |
| Length Options | 150 mm (standard), custom lengths available |
| Diameter Options | 50 mm or 70 mm |
| Weight | 260 g (150 mm, Ø70 mm) |
| Mounting Angle Tolerance | ±85° |
| Thermal Resistance | 0.12 K/W (natural convection, 12-module COMET Matrix, Ø70 mm) |
| Lightness | 50% weight reduction vs. conventional aluminum heatsinks |
| Tooling | No mold cost — rapid prototyping from standard modules |
| Design Flexibility | Fully modular platform for iterative thermal architecture development |
| Production Scalability | Direct transition from prototype to volume manufacturing |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIRIUS |
| Pricing | Upon Request |
| Thermal Resistance | 0.44–0.77 K/W |
| Max Thermal Channel Length | 500 mm |
| Material | Monolithic Aluminum NEOcore Structure |
| Cooling Mechanism | Passive Two-Phase Heat Transfer (Evaporation–Condensation Cycle) |
| Weight Class | Ultra-Lightweight |
| Design Flexibility | Customizable Fin Angle & 3D Geometry |
| Power Handling Capacity | Hundreds of Watts (Application-Dependent) |
| Compliance | Designed for ISO 9001-certified manufacturing |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Model | ULTIMA |
| Heat Sink Material | Aluminum |
| Working Fluid | Hydrocarbon-based Phase-Change Medium |
| Weight | 2.7 kg |
| Mounting Angle | 0° ±5° |
| Thermal Resistance | 0.028 K/W |
| Max Operating Temperature | 150 °C |
| Operating Temperature Range | −20 °C to +150 °C |
| Ambient Temperature Range | −20 °C to +60 °C |
| Storage Temperature Range | −50 °C to +90 °C |