Thermal Analysis Instruments
Filter
Showing 241–270 of 922 results
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | STA300 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy | ±0.2 K |
| Temperature Precision | ±0.07 °C |
| Heating/Cooling Rate | 0.01–150 K/min |
| Maximum Sample Mass | 0.2 g |
| Brand | Hitachi |
|---|---|
| Origin | Imported |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 °C to 600 °C |
| Frequency Range | Sinusoidal mode: 0.01–200 Hz |
| Composite waveform mode | simultaneous 5 frequencies |
| Compliance | ASTM D4065, ISO 6721, ISO 11357-4, USP <1031>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | Hitachi |
|---|---|
| Model | DSC600 / DSC200 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Throughput | Multi-sample simultaneous measurement |
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Application Scope | Polymer, Pharmaceutical, Chemical, Petrochemical, Food, and Metallic Materials Characterization |
| RealView® Imaging System | Integrated 20-MP camera with 50× digital zoom and 1.2 µm pixel resolution |
| Polarized Light Capability | Optional polarized optical module for birefringence and crystalline orientation analysis |
| Data Export Formats | CSV, Excel (.xlsx), plain text |
| Barcode Integration | Supported for automated method and sample metadata ingestion |
| Software Compliance | Audit-trail enabled |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model Variants | STA7200, STA7200RV, STA7300 |
| Heating Rate | 0.01–150 °C/min |
| Temperature Range | Ambient to 1100 °C |
| Temperature Stability | ±0.1 °C over full range |
| Maximum Sample Capacity | ±400 mg |
| Atmosphere Options | Ambient air, inert gas (N₂, Ar), optional gas flow control via mass flow meter |
| Real-Time Sample Imaging | Up to 1000 °C with RV-3TG optical module |
| Autosampler Compatibility | AS-3T (50-position) |
| Control Architecture | Digital horizontal differential balance with active drift compensation |
| Cooling Method | FRONT-STREAM low-thermal-mass design |
| Brand | Hitachi |
|---|---|
| Model | TMA7100 / TMA7300 |
| Temperature Range | TMA7100: −170 °C to 600 °C |
| TMA7300 | Ambient to 1500 °C |
| Displacement Range | ±5 mm |
| RMS Noise / Sensitivity | 0.005 μm / 0.01 μm |
| Load Range (Resolution) | ±5.8 N (9.8 μN) |
| Heating Rate | 0.01–100 °C/min |
| Sample Max Dimensions | Ø10 mm × 25 mm (TMA7100/TMA7300) |
| Probe Mounting | Cantilever-type |
| Atmosphere Control | Ambient air, inert gas, vacuum (~1.3 Pa) |
| Load Control Modes | Fixed load, constant-rate loading (9.8×10⁻²–9.8×10⁶ mN/min), frequency sweep (0.001–1 Hz), multi-step program (up to 40 steps) |
| Displacement Control Modes | Fixed displacement (±5000 μm), constant-rate displacement (0.01–10⁶ μm/min), frequency sweep (0.001–1 Hz), multi-step program (up to 40 steps) |
| Optional Accessories | Automated liquid nitrogen cooling system (−150 °C to 600 °C), electronic cooler (−60 °C to 450 °C), fan-assisted ambient cooling (RT to 600 °C or 1500 °C), LN₂ Dewar kit (−170 °C to 600 °C), mass flow controller, humidity control module, expansion/compression/penetration/tensile/bending probes (quartz or alumina), sapphire dilatometry fixture |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | TMA7100 / TMA7300 |
| Temperature Range | –170 °C to 600 °C (TMA7100) |
| Displacement Range | ±5 mm |
| Sensitivity (RMS Noise) | 0.005 µm / Resolution: 0.01 µm |
| Load Range | ±5.8 N (Resolution: 9.8 µN) |
| Heating Rate | 0.01–100 °C/min |
| Sample Max Dimensions | Ø10 mm × 25 mm (cylindrical) or 5 mm × 1 mm × 25 mm (film) |
| Probe Mounting | Cantilever-type |
| Atmosphere Control | Ambient, inert gas, vacuum (~1.3 Pa), optional humidity & swelling modules |
| Load/Displacement Control Modes | Constant force, constant rate, oscillatory (0.001–1 Hz), multi-step sequences (up to 40 steps) |
| Optional Cooling | Automated LN₂ cooling (–150 °C to 600 °C), electronic cooler (–60 °C to 450 °C), forced-air cooling (RT–600 °C), LN₂ Dewar kit (–170 °C to 600 °C) |
| Sample Tube Materials | Quartz (TMA7100), Alumina (TMA7300) |
| Probe Types | Expansion/compression quartz, penetration (standard & conical), tensile (quartz & metal), bending, sapphire dilatometry |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | TMA7100/TMA7300 |
| Heating Rate | 0.01–100 °C/min |
| Temperature Range | –170 to 600 °C (standard) |
| Temperature Stability | ±0.1 °C over –170 to 600 °C |
| Maximum Sample Mass | ±400 mg |
| Atmosphere Control | Ambient air, inert gas (N₂, Ar), vacuum (~13 Pa)*² |
| Cooling Options | Liquid nitrogen (40% reduced consumption vs. prior models), optional Peltier-based electronic cooling |
| Gas Flow Control | Integrated mass flow controller for automated gas switching and precise atmosphere regulation |
| Humidity Capability | Optional high-temperature/humidity module for swelling and hygrothermal testing |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | 2500S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–2000 W/m·K |
| Temperature Range | 30 K to 1000 °C |
| Accuracy | ±3% |
| Repeatability | <1% |
| Sample Forms | Solids, Liquids, Powders, Pastes, Thin Films, Coatings, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Dimensions (L×W×H) | 500 × 450 × 320 mm |
| Probe Diameter Options | 2–29.4 mm |
| Additional Outputs | Thermal Diffusivity (±5%), Volumetric Heat Capacity (±7%) |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | TPS 1500 |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–20 W/m·K |
| Temperature Range | −50 to 750 °C |
| Accuracy | < ±3% |
| Repeatability | < ±1% |
| Sample Forms | Solids, Powders, Pastes, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Dimensions (L×W×H) | 50 × 40 × 30 cm |
| Probe Sizes | 2–29.4 mm |
| Compliance | ISO 22007-2 |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | TPS 2500S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–2000 W/m·K |
| Temperature Range | 30 K to 1000 °C |
| Accuracy | < 3% |
| Repeatability | < 1% |
| Sample Forms | Solids, Liquids, Powders, Pastes, Thin Films, Coatings, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Dimensions (L×W×H) | 500 × 450 × 320 mm |
| Compatible Modules | Basic, Thin-Film, Plate, Anisotropy, Single-Sided, Specific Heat |
| Brand | Hot Disk |
|---|---|
| Origin | Sweden |
| Model | TPS3500 |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.005–2000 W/(m·K) |
| Thermal Diffusivity Range | 0.01–1200 mm²/s |
| Volumetric Heat Capacity Range | up to 5 MJ/(m³·K) |
| Temperature Range | 30 K to 1000 °C |
| Minimum Test Duration | 0.1 s |
| Accuracy | < 3% |
| Repeatability | < 1% |
| Sample Forms | Solids, Liquids, Powders, Pastes, Thin Films, Coatings, Anisotropic & Composite Materials |
| Test Atmosphere | Air, Vacuum, or Inert Gas |
| Sample Dimensions (Min) | 2 mm diameter × 0.5 mm thickness (bulk), 8 mm diameter × 0.1 mm thickness (thin films) |
| Dimensions (L×W×H) | 600 × 460 × 330 mm |
| Compliance | ISO 22007-2:2008 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HPA-300 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Heat Flow Method |
| Dimensions (L×W×H) | 750 × 650 × 1100 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.015–100 W/(m·K) |
| Repeatability | ±1% |
| Maximum Test Temperature | 300 °C |
| Applied Load Range | 0–1000 N (adjustable) |
| Specimen Size | φ50 × 100 mm or φ37.5 × 100 mm |
| Cooling Base Temperature | 20 °C (integrated constant-temperature water bath) |
| Axial Temperature Sensors | 4 points |
| Radial Temperature Sensors | 3–6 gradient points |
| Heating Power | 60 W |
| Software | Fully Automated Acquisition & Analysis Suite with Touchscreen Interface |
| Brand | Huafeng |
|---|---|
| Origin | Hunan, China |
| Model | DIL0806A-1400 |
| Temperature Range | RT to 1400 °C |
| Heating Rate | 0–20 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Displacement Resolution | 0.1 µm |
| Atmosphere Options | Vacuum and Controlled Gas |
| Sample Holder Material | Alumina |
| Maximum Displacement Range | 5000 µm |
| Sample Dimensions | Ø5–8 mm × 25–50 mm (cylindrical or rectangular) |
| Thermal Expansion Coefficient Resolution | 0.001 × 10⁻⁶ K⁻¹ |
| System Measurement Uncertainty | ±0.1% |
| Interface | USB 2.0 |
| Compliance | ASTM E831, ASTM D696, ASTM D3386, DIN 51045 |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCYQ-STA-1550 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1550 °C |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Options | N₂, O₂ |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TGA-605 |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Mass Sensitivity | 0.01 mg |
| Mass Repeatability | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | ±0.1 °C |
| Baseline Reproducibility | ±0.1 °C |
| Sampling Frequency | 0.05–10 Hz (programmable) |
| Dual-Temperature Sensing | Furnace & Sample |
| Control Modes | FTC (Fixed Temperature Control) & STC (Sample Temperature Control) |
| Programmable Temperature Stages | Up to 12 |
| Cycle Repetition | Up to 9999 cycles with auto-data retention |
| Atmosphere Control | Two independent gas lines with software-driven switching |
| Display | 7-inch 24-bit color LCD touchscreen |
| Cooling System | Integrated capillary water-circulation furnace jacket |
| Furnace Design | Modular ceramic insulation with dual-purge gas channels |
| Optional Exhaust Interface | Dedicated port for off-gas coupling to FTIR or MS |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | PCY-SL-30 |
| Price Range | USD 1,400–7,000 |
| Temperature Range | −30 °C to 30 °C |
| Heating Rate | 5 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Sample Diameter | 6–10 mm |
| Measurement Range | 5 mm |
| Resolution | 1 µm |
| Atmosphere Options | Air, Vacuum, Inert Gas |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (PRC) |
| Model | DSC0901 |
| Pricing | Available Upon Request |
| Differential Heat Range | ±2000 µV |
| DSC Power Range | ±10, ±20, ±50, ±100, ±160, ±200 mW (auto-switching) |
| Temperature Range Options | RT–450°C, RT–1150°C, RT–1400°C, RT–1650°C |
| Heating Rate | 0.1–30 °C/min (programmable) |
| Temperature Control Modes | Ramp, Isothermal, Cooling, PID-regulated |
| Base Resolution | 2 µg |
| Sensitivity | 10 µg |
| TGA Capacity | 1–1000 mg (selectable ranges) |
| DTG Range | 0.1–10 mg/min (selectable) |
| Gas Flow Control | Dual-channel mass flow controllers (N₂, O₂), ≤200 mL/min |
| Max Sample Load | 2 g |
| A/D Resolution | 24-bit |
| Data Output | Printer, chart recorder, PC interface |
| Power Supply | 220 V AC ±1 Hz, 50 Hz |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HWX-II |
| Price | Upon Request |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Static Jacket (22 °C and 30 °C) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40 000 J |
| Cooling Medium | Tap Water |
| Cooling Flow Rate | 50–60 L/h (55 L/h at 18 °C) |
| Max Oxygen Pressure | 40 bar |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % RH |
| Protection Rating | IP20 |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Compliance | DIN 51900, ISO 1928 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol (Regnault–Pfaundler isothermal principle) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40,000 J |
| Outer Water Bath Capacity | Not specified |
| Inner Water Bath Capacity | Not specified |
| Cooling Medium | Tap water |
| Min. Coolant Flow Rate | 50–60 L/h at 18 °C |
| Max. Oxygen Pressure | 40 bar |
| Protection Rating | IP20 |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Compliance | DIN 51900, ISO 1928 |
| Interfaces | RS232 (balance, printer, PC), USB |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IKA C 3000 eco Package |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibolic Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| Outer Water Jacket Volume | unspecified |
| Inner Water Jacket Volume | unspecified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C200 |
| Measurement Modes | Isothermal, Fast Dynamic, Manual, Time-Controlled |
| Standards Compliance | DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711 |
| Max Energy Range | 40,000 J |
| Operating Voltage | 24 V DC (instrument), 100–240 V AC / 50–60 Hz (external power supply) |
| Power Consumption | ≤100 W (calorimeter), ≤120 W (system) |
| Dimensions (W×D×H) | 400 × 400 × 400 mm |
| Weight | 21 kg |
| Protection Class | IP21, Class III |
| Ambient Conditions | 20–25 °C, ≤80 % RH, up to 2,000 m altitude |
| Interfaces | 1× RS-232, 1× Centronics parallel port |
| Software | Calwin C 5040 (real-time monitoring, data export to Excel/Word) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | E2K |
| Operating Temperature Range | 0–60 °C |
| Temperature Repeatability | ≤0.1% RSD |
| Temperature Resolution | 1 µK |
| Gross Calorific Value Resolution | 0.001 MJ/kg |
| Calibration | 10 stored calibration curves per smart bomb vessel, automatic standard deviation correction, integrated calibration sensors per vessel |
| Sample Throughput | Up to 10 samples/hour (standard configuration) |
| Measurement Time | 1.5–3 min per test |
| Dimensions (W×D×H) | 280×400×290 mm |
| Weight | 9 kg |
| Data Storage Capacity | >1000 test records with full metadata (operator ID, ambient conditions, calibration traceability) |
| Connectivity | Ethernet-enabled for multi-unit network (up to 7 units) |
| Ignition Control | Adjustable ignition energy, programmable high/low sample mass limits, customizable test cycle parameters |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | YND-OM4 |
| Temperature Range | RT to 500 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Up to 8 samples per run (configurable for 4/6/8) |
| DSC Range | 0 to ±500 mW |
| DSC Resolution | 0.01 mW |
| DSC Sensitivity | 0.01 mW |
| Gas Control | Dual-channel mass flow control (N₂/O₂), 0–200 mL/min, accuracy ±0.2 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Interface | Integrated USB 2.0 |
| Display | 7-inch color capacitive touchscreen |
| Compliance | GB/T 19466.3–2009 / ISO 11357-3:1999 (OIT determination) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS302 |
| Temperature Range | −190 °C to 400 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.01 °C at 100 °C |
| Max Heating Rate | +100 °C/min at 100 °C |
| Max Cooling Rate | −100 °C/min at 100 °C |
| Min Working Distance | 3.3 mm (outer window removed) |
| Operating Working Distance | 5.6 mm |
| Condenser Distance | 10.0 mm |
| Sample Area | 38 mm × 50 mm |
| Chamber Height | 2.0–12.5 mm (with optional spacers) |
| Viewing Aperture Options | 2 / 5 / 8 / 10 mm |
| Optional X-Y Micropositioner | 10 µm resolution |
| Temperature Sensor | 100 Ω Platinum RTD |
| Control Method | Switching PID (LVDC PID optional) |