Thermal Analysis Instruments
Filter
Showing 211–240 of 922 results
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | HSC-1 |
| Sample Capacity | Single |
| Temperature Range | Ambient to 680 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0 to ±500 mW |
| DSC Minimum Resolution | ±0.1 µW |
| DSC Power Noise | ±0.1 µW |
| DSC Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow-controlled gas system (10–200 mL/min), auto-switchable |
| Standard Crucibles | Al₂O₃, high-purity Al |
| Optional Crucibles | Sealed Al (liquid/solid), ZrO₂, quartz, graphite, Pt/Rh |
| Crucible Volume | 0.06 mL |
| Cooling Method | Forced-air |
| Display | Large-character LCD with dual thermocouples (sample + furnace) |
| Interface | RS232 + USB |
| Software Features | Auto-baseline correction, calibration with certified standards (In, Sn, Pb, Zn, Al), automated report generation (Tg, Tm, ΔH, OIT), remote diagnostics & parameter tuning via Internet |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSC-2 / HSC-3 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −30 °C to 680 °C (HSC-2, mechanical cooling) / −100 °C to 680 °C (HSC-3, liquid nitrogen cooling) |
| Programmable Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| DSC Sensitivity (Minimum Detectable Heat Flow) | ±0.1 μW |
| Baseline Noise | ±0.1 μW |
| Power Accuracy | ±0.1 μW |
| Standard Crucibles | Alumina (Φ5 mm × 4 mm) or Aluminum (Φ5 mm × 4 mm) |
| Optional Crucibles | Hermetic aluminum crucibles (with crimping tool for solids/liquids) |
| Atmosphere Control | Dual-channel mass flow controllers (corrosion-resistant variants available on request) |
| Heated Zone Temperature Range | 0–400 °C |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | HSC-2 |
| Sample Capacity | Single |
| Temperature Range | −30 °C to 680 °C (with optional mechanical cryo-cooling unit) |
| Programmable Temperature Control Accuracy | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Repeatability) | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Heating, Isothermal, Cooling |
| DSC Signal Range | ±500 mW |
| DSC Minimum Resolution | ±0.1 µW |
| DSC Power Noise | ±0.1 µW |
| DSC Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow-controlled gas system (10–200 mL/min), software-switchable |
| Standard Crucibles | Al₂O₃, high-purity Al (0.06 mL capacity) |
| Optional Crucibles | Sealed Al (liquid/solid), ZrO₂, quartz, graphite, Pt/Rh |
| Display | Large-character Chinese LCD with dual thermocouples (sample + furnace) |
| Connectivity | RS232, USB interface |
| Software Features | Automated baseline correction, thermal event annotation (Tg, Tm, Tc, OIT), enthalpy integration, calibration with certified standards (In, Sn, Pb, Zn, Al), auto-report generation (DSC & OIT), remote diagnostics and parameter tuning via internet |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Heat-Flow DSC |
| Model | HSC-3 |
| Sample Capacity | Single |
| Temperature Range | −100 °C to 680 °C (with manual liquid nitrogen cooling) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | 0 mW to ±500 mW |
| Temperature Stability | ±0.1 °C |
| DSC Resolution | ±0.1 µW |
| Power Noise | ±0.1 µW |
| Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controlled (10–200 mL/min, auto-switchable) |
| Crucible Options | Al₂O₃, high-purity Al (standard) |
| Calibration Standards Included | In, Sn, Pb, Zn, Al |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | HSC-4 |
| Sample Capacity | Single |
| Temperature Range | –100 °C to 680 °C (with automated liquid nitrogen cooling) |
| Programmable Temperature Control Accuracy | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Repeatability) | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Isothermal, Heating Scan, Cooling Scan |
| DSC Signal Range | 0 to ±500 mW |
| DSC Minimum Detectable Heat Flow | ±0.1 µW |
| DSC Power Noise Level | ±0.1 µW |
| DSC Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controlled gas system (10–200 mL/min), auto-switchable |
| Standard Crucibles | Al₂O₃, high-purity aluminum (0.06 mL capacity) |
| Optional Crucibles | Sealed aluminum (solid/liquid), ZrO₂, quartz, graphite, Pt/Rh |
| Display | Large-character LCD with dual thermocouple readout (sample + furnace) |
| Connectivity | RS232, USB interface |
| Software Features | Automated baseline correction, thermal event identification (Tg, Tm, Tc, OIT), enthalpy integration, calibration with certified standards (In, Sn, Pb, Zn, Al), GLP-compliant report generation, remote diagnostics and parameter adjustment via internet |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laser Flash Method |
| Sample Capacity | Single or 6-position auto-rotating sample holder (configurable) |
| Operating Environment | High-Temperature, Controlled Atmosphere |
| Thermal Conductivity Range | 0.1 – 2000 W/(m·K) |
| Accuracy | ±2.4% (thermal diffusivity) |
| Repeatability | ±1.9% (thermal diffusivity) |
| Laser Source | Nd:YAG, 1064 nm, 25 J/pulse, Class 1 safety |
| Pulse Width | 0.05–5 ms (software-adjustable) |
| Temperature Range | RT to 1600 °C |
| Atmosphere Options | Inert, oxidizing, reducing, dynamic/static gas, vacuum (down to 10⁻² mbar) |
| Sample Forms | Solid bulk, thin film, fiber, powder, composite, and liquid media |
| Standard Sample Dimensions | Ø6–25.4 mm discs or 6×6–10×10 mm squares |
| Detector | Liquid-nitrogen-cooled InSb or MCT |
| Data Interface | USB & TCP/IP |
| Cooling | Dual-mode — closed-loop water + forced-air |
| Compliance | ASTM E1461, ISO 22007-4, DIN 30905, GB/T 22588, GJB 1201.1-91 |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HT-1700 |
| Configuration | TG-DSC Coupled System |
| Temperature Range | Ambient to 1700 °C |
| Heating/Cooling Rate | 0.1–200 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 200 mg (extendable to 5 g with optional support rods) |
| Balance Sensitivity | 0.1 µg |
| Thermogravimetric Noise | <0.1 µg |
| DSC Range | ±500 mW |
| DSC Precision | ±0.1 µW |
| DSC Response Ratio | >100 mW/K |
| Enthalpy Accuracy | ±0.1% (using In calibration) |
| DTA Range | ±2000 µV |
| DTA Resolution | 0.01 µV |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum, Steam |
| Standard Crucibles | Al₂O₃ (0.06 mL and 0.12 mL) |
| Optional Crucibles | Al, Graphite, Quartz, Pt |
| Vacuum & Gas Purge | Integrated automated vacuum/purge system with programmable gas switching |
| Temperature Calibration | Multi-point non-linear calibration using certified reference materials (In, Zn, Sn, Pb, Al, Cu) |
| Control Program | Up to 64 segments, 999 cycles, power-fail data retention |
| Data Export | ASCII, MS Excel-compatible CSV, real-time multi-curve overlay, differential analysis, kinetic modeling (e.g., Kissinger, Ozawa-Flynn-Wall) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Temperature Range | −150 to 1550 °C (with liquid nitrogen cooling) |
| Programmable Temperature Control | Heating, Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min (user-definable) |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Pressure Range | 0.1–10.0 MPa |
| Pressure Accuracy | ±0.002 MPa |
| Pressure Control Mode | Dynamic Pressure Regulation |
| Calorimetric Accuracy | ±1% (vs. certified metal standards) |
| Calibration Method | Multi-point Nonlinear Temperature Calibration |
| Atmosphere Options | Oxidizing, Reducing, Inert, Steam |
| Measurement Modes | Static, Dynamic, Variable Pressure & Gas Flow |
| Sensor Configurability | Interchangeable sensor modules |
| Software | Windows-based bilingual (EN/CN) control & analysis suite |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HTF |
| Price Range | USD 70,000–110,000 |
| Sample Capacity | Single sample per run |
| Instrument Type | Dedicated TGA platform |
| Temperature Range | Ambient to 950 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 K |
| Dynamic Weighing Range | 1 mg–200 mg or 0–5 g (selectable) |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–30 K/min |
| Maximum Sample Mass | 5 g |
| Pressure Control Range | 0.1–5 MPa (at elevated temperature) |
| Pressure Control Precision | ±0.02 MPa |
| Steam Generation Range | 0.01–1000 mL/min (saturated water vapor, computer-controlled) |
| Atmosphere Control | Triple independent mass flow-controlled gas lines with automated switching and stabilization |
| Crucible Options | Standard ceramic crucible (Ø80 mm × H70 mm), compatible with sample masses up to 50 g |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HTF-50 |
| Price Range | USD 70,000–112,000 (FOB Beijing) |
| Test Environment | High-Pressure Atmosphere |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Dedicated TGA platform |
| Temperature Range | Ambient to 950 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Accuracy | ±0.1 K |
| Dynamic Weighing Range | 1 mg–200 mg or 0–5 g (user-selectable) |
| Balance Sensitivity | 10 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–30 K/min |
| Maximum Sample Mass Capacity | 500 g |
| Baseline Drift | ≤0.01% (full-scale) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | HTG |
| Pricing | Available Upon Request |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-1 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-2 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Vacuum Option | Up to 2.5 × 10⁻² Pa (with optional vacuum unit) |
| Standard Crucibles | Al₂O₃ (Φ5×4 mm, Φ5×8 mm, Φ8×10 mm, Φ18×8 mm, Φ18×15 mm, Φ18×20 mm) |
| Optional Crucibles | Aluminum, Graphite, Quartz, Platinum |
| Dual Thermocouples | Furnace Temp + Sample Temp Monitoring |
| Isothermal Hold Capability | Up to 72 h at any temperature within range |
| Data Output Modes | TG, DTG, DDTG, % Mass Loss, Kinetic Parameter Derivation, Multi-Curve Overlay & Differential Analysis |
| Software Calibration Support | Temperature & Mass calibration using certified reference materials |
| Optional Accessories | Isothermal Controller, GC/MS Transfer Interface (heated, 200 °C max), Heated Transfer Line, Corrosion-Resistant MFC Atmosphere System |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-3 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-4 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTS-1400 |
| Temperature Range | Ambient to 1400 °C (High-Temp Zone), –20 °C to 100 °C (Liquid Quench Zone) |
| Max Ramp Rate | 40 °C/min |
| Control Precision | ±0.5 °C (Furnaces), ±0.1 °C (Water Bath) |
| Transfer Time | ≤2 s |
| Vacuum System | ≤10 Pa (4 L/s pumping speed) |
| Gas Control | 3-channel MFC (0–100 mL/min, N₂/Ar/He) |
| Sample Capacity | ≤30 mm cube, any geometry, compatible up to 1400 °C |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HWD-50g/500g |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.1 K |
| Dynamic Weighing Range | 10–50 g |
| Balance Sensitivity | 1000 µg |
| Mass Accuracy | 0.01% (100 ppm) |
| Heating/Cooling Rate | 0.1–40 K/min |
| Maximum Sample Mass | 500 g |
| Baseline Drift | ≤0.01% over 60 min |
| Weight Resolution | 1 mg |
| Weight Noise | <1 mg |
| Gas Control | Triple Mass Flow Controllers (MFCs) |
| Crucible Dimensions | Ceramic, Ø80 mm × H70 mm |
| Water Vapor Generator Output | 0.01–1000 mL/min (±0.01 mL/min resolution) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Henven Scientific Instrument Co., Ltd. |
| Type | Differential Scanning Calorimeter (DSC) |
| Model | HYD |
| Sample Capacity | 1 |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| DSC Signal Range | 0 to ±500 mW |
| DSC Resolution | ±0.1 µW |
| DSC Accuracy | ±0.1 µW |
| Crucible Volume | 0.06 mL or 0.12 mL |
| Atmosphere Control | Dual-gas (N₂/O₂) with Mass Flow Controllers (MFCs) |
| Programmable Thermal Profiles | Isothermal hold, linear ramp, gas-switch-triggered transition |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Model | TMA-101 |
| Temperature Range | Ambient to 950 °C |
| Temperature Accuracy | ±0.1 °C |
| Static Force Range | 0.1–3 N |
| Displacement Range | ±1000 µm |
| Displacement Resolution | 150 nm–1 µm |
| Sensitivity | 0.1 µm |
| Heating Rate | 0.1–10 °C/min (programmable) |
| Sample Height | 1–3 mm (solid) |
| Test Atmosphere | Optional inert gas purge |
| Power Supply | 220 V ±10% |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature (20–30 °C) |
| Dimensions (L×W×H) | 450 × 385 × 165 mm |
| Accuracy | ±3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ≤3% |
| Test Atmosphere | Ambient air (no purge required) |
| Sample Forms | Solids, powders, liquids, pastes, granules, gels, coatings, thin films, and insulating materials |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Transient Plane Source Method |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature (20–30 °C) |
| Dimensions (L×W×H) | 450 × 385 × 165 mm |
| Accuracy | ≤3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ≤3% |
| Probe Options | 7.5 mm and 15 mm diameter dual-spiral probes |
| Measurement Time | 5–160 s (user-configurable) |
| Max. Sample Temperature Rise | <15 °C |
| Power Supply | 220 V AC, <500 W |
| Compatible Sample Forms | Solid blocks, powders, pastes, gels, liquids, coatings, films, foams, and insulating materials |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Precision | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability (Drift) | ±0.01 °C |
| DSC Resolution | 0.001 mW |
| Temperature Resolution | 0.01 °C |
| Gas Flow Control | Dual-channel automatic switching, 0–300 mL/min (customizable) |
| Calibration Standards Included | Indium, Tin, Lead |
| Thermocouple Configuration | Triple thermocouples (sample, furnace ambient, overheat safety) |
| Power Supply | AC 220 V / 50 Hz |
| Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±600 mW |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| DSC Resolution & Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), Flow Range: 0–300 mL/min |
| Calibration Standards Included | Indium, Tin, Lead |
| Compliance | GB/T 41873–2022, GB/T 19466.3–2004 |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-STA-002 |
| Coupling Technique | Thermogravimetry–Differential Scanning Calorimetry (TG-DSC) |
| Heating Rate | 0.1–80 °C/min |
| Temperature Range | Ambient to 1150 °C |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 2 g (expandable to 30 g) |
| Atmosphere Control | Dual-gas channel with automatic switching (N₂ standard) |
| Flow Rate | 0–300 mL/min |
| TG Resolution | 10 µg |
| TG Dynamic Range | 1 mg–2 g |
| DSC Range | ±700 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy & Repeatability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | 15 min |
| Control Modes | Programmable heating, isothermal hold, and cooling |
| Data Interface | Standard USB |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 470 × 580 × 460 mm |
| Display | 7-inch 24-bit color LCD touchscreen |
| Core Processor | 32-bit ARM Cortex-M3 |
| ADC | 24-bit, 4-channel synchronous sampling for TG, DSC, and T signals |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS-STA-002 (Simultaneous TGA-DTA Analyzer) |
| Temperature Range | Ambient to 1150 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 2 g |
| Atmosphere | Nitrogen (dual-gas auto-switching, 0–300 mL/min, ≤0.5 MPa) |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HS-STA-302 |
| Price | Upon Request |
| Temperature Range | RT to 1300 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 3 g |
| Atmosphere | Nitrogen (dual-gas automatic switching, 0–300 mL/min, ≤0.5 MPa) |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | RT to 1150 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 10 µg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 2 g |
| Baseline Drift | ≤10 µg |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-302 |
| Test Environment | Ambient Pressure |
| Sample Capacity | 1 sample per run |
| Instrument Type | General-purpose |
| Temperature Range | RT to 1300 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0–100 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤10 µg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP-DST Series |
| Temperature Range | Ambient to 150 °C |
| Temperature Control Accuracy | ≤ ±0.2 °C |
| Maximum Pressure Rating | 16 MPa |
| Pressure Monitoring Range | 0–600 kPa |
| Sample Basket Volume | 50 mL |
| Gas Purification Method | Vacuum-assisted absorption into chemical scrubbing solution |
| Alarm System | Multi-modal (audible buzzer, visual LED, GUI color flash & pop-up alert) |
| Control Architecture | ARM-based embedded system with integrated touchscreen HMI |
| Data Acquisition | Synchronized sampling of bath temperature, sample temperature, pressure, and alarm status |
| Online Gas Sampling Interface | Dedicated port for real-time effluent gas transfer to external analytical instruments (e.g., MS, GC-MS, FTIR) |
| Construction Material | 304 stainless steel (pressure vessel, heating chamber, gas path components) |
| Power Supply | 220 V AC, 2000 W |
| Compliance | Designed per GB/T 29875–2013 (Chinese standard for propellant thermal stability testing), compatible with ASTM E2070 and ISO 11270 methodologies for energetic material aging assessment |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | DSC7000 |
| Heating Rate | 0.01–100 °C/min |
| Temperature Range | –150 to 725 °C |
| Baseline Stability | ±5 µW |
| Sensitivity | <0.1 µW |
| Maximum Sample Power Capacity | ±350 mW |
| Atmosphere Options | Ambient Air, Inert Gas (N₂, Ar) |
| Cooling Options | Integrated Peltier Cooling (–80 to 500 °C), Optional Automated Liquid Nitrogen Cooling (–150 to 725 °C) |
| Optional Modules | Mass Flow Controlled Gas Delivery System, Auto Sampler Unit, UV Irradiation Unit (with Intensity Meter & Wavelength-Selective Filters), Real-Time Sample Observation Unit |
