Thermal Shock Test Chamber
Filter
Showing 331–360 of 495 results
| Brand | Qingji |
|---|---|
| Model | QJCLR8731 |
| Temperature Range (High Zone) | 60–200 °C |
| Temperature Range (Low Zone) | –10 to –65 °C (standard), optional –75 °C |
| Test Chamber Operating Range | –10 to –60 °C |
| Temperature Stability | ±1 °C |
| Temperature Uniformity | ±2 °C |
| Recovery Time | ≤5 min |
| Heating Rate (Typical) | 40 min (from –40 °C to +150 °C) |
| Cooling Rate (Typical) | 60–90 min (from +150 °C to –40 °C) |
| Controller | 7.5″ color LCD touchscreen with bilingual (English/Chinese) interface, 256-color display, adjustable backlight, direct-key operation |
| Safety Protections | Fuseless circuit breaker, compressor high-pressure/overheat/overcurrent protection, chamber overtemperature cutoff, fan overload protection |
| Standard Accessories | Two sample racks, one 50 mm diameter cable port |
| Compliance | GB/T 2423.1–2021, GB/T 2423.2–2001, GJB 150.5A–2009, GB 10592–2008 |
| Brand | Sciteq |
|---|---|
| Origin | Denmark |
| Model | TC-micro |
| Configuration Options | TC50 (2ר50 mm or 4ר32 mm) / TC63 (2ר63 mm or 4ר32 mm) |
| Pressure Control | Constant-pressure hydraulic circuit |
| Thermal Range | 5–95 °C (adjustable setpoints) |
| Water Reservoirs | Dual 500 L pressurized tanks (hot & cold) |
| Flow Monitoring | Integrated inline flow sensors per test channel |
| Minimum Flow Velocity | ≥0.5 m/s (automatically maintained) |
| Test Chamber Architecture | Four independent, sealed micro-chambers with individual leak detection |
| Control Interface | 15-inch industrial touchscreen HMI with PLC-based logic |
| Safety Compliance | EN 61000-6-2/6-4, EN ISO 13857, integrated emergency stop circuits |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -65°C to +180°C |
| Thermal Transition Time | ≤15 s (typical between chambers) |
| Control System | TEMI880 Color Touchscreen Controller (English/Chinese Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Refrigeration | Twin-Stage or Single-Stage Hermetic Compressor (Original Tecumseh or Copeland) |
| Insulation | Rigid Polyurethane Foam (≥100 mm) + Ultra-Fine Glass Fiber |
| Interior Material | SUS304 Stainless Steel |
| Exterior Finish | Electrostatic Powder-Coated Cold-Rolled Steel or Optional Brushed SUS304 |
| Air Circulation | Wide-Band Forced Convection with Centrifugal Blower |
| Compliance | ASTM D5229, MIL-STD-883 Method 1010, JESD22-A104, IEC 60068-2-14 |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SET-B31 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −65 °C |
| Thermal Shock Range | −65 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 30 °C/min |
| Cooling Rate | 30 °C/min |
| Brand | SETH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SET-K |
| Price | Upon Request |
| High-Temperature Range | +60 °C to +200 °C |
| Low-Temperature Range | +20 °C to −80 °C |
| Thermal Shock Range | +60 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 3.5 °C/min |
| Cooling Rate | 1.5 °C/min |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -70°C to +180°C |
| Shock Transition Time | ≤5 min (typical, 150°C ↔ -70°C) |
| Internal Volume | Standard 100 L / 200 L / 400 L options |
| Control System | TEMI880 Color Touchscreen Programmable Controller (English/Chinese UI) or TEMI300 Keypad-Based Controller (English-only) |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.5, GB/T 2423.22 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Switching Mechanism | Pneumatic damper–actuated air door, static test specimen |
| Preheating Time (RT→150 °C) | ~30 min |
| Precooling Time (RT→−70 °C) | ~85 min |
| Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Refrigeration System | Dual-stage cascade refrigeration with semi-hermetic compressors (Germany-sourced), R404A/R23 refrigerants |
| Inner Chamber Material | SUS#304 mirror-finish stainless steel |
| Outer Chamber Material | SUS#304 stainless steel or powder-coated steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m cable |
| Accessories | One Φ50 mm cable port |
| Brand | SuYing |
|---|---|
| Origin | Shanghai, China |
| Model | LRCJ-100 / LRCJ-200 / LRCJ-500 |
| Temperature Range (A/B/C) | -20°C to 200°C / -40°C to 200°C / -60°C to 200°C |
| Temperature Transition Time | ≤15 s |
| Temperature Recovery Time | ≤5 min |
| Sample Zone Temp. Uniformity | ±0.5°C (at steady state) |
| Sample Load Capacity | 20 kg / 30 kg / 50 kg |
| Controller | OYO dual-loop LCD touch-panel temperature controller |
| Compliance | GB/T 2423.1–2, GB 10592–1989, GJB 150A–2009 |
| Refrigerants | R404A (high-stage), R23 (low-stage) |
| Cooling Method | Air-cooled binary cascade refrigeration system |
| Brand | SuYing |
|---|---|
| Origin | Shanghai, China |
| Model | WDCJ-100 / WDCJ-250 / WDCJ-500 |
| Temperature Range (A/B/C) | -20/-40/-60 ℃ to 200 ℃ |
| Transfer Time (Hot ↔ Cold) | ≤15 s |
| Temperature Recovery Time | ≤5 min |
| Sample Zone Temp. Uniformity | ±0.5 ℃ (at steady state) |
| Sample Load Capacity | 20–50 kg |
| Compressor System | Dual-stage cascade refrigeration (R404A/R23) |
| Controller | OYO 9882 dual-loop touch-screen PID controller |
| Compliance | GB/T 2423.1–2, GB 10592–1989, GJB 150A–2009 |
| Power Consumption | 5.7–16 kW (model-dependent) |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | Temptronic TP04300 |
| Temperature Range | −80 °C to +225 °C |
| Cooling Medium | Non-ozone-depleting refrigerant (no LN₂ or LCO₂ required) |
| Airflow Output | 4–18 SCFM (1.8–8.5 L/s) |
| Ramp Rate | <10 s from −55 °C to +125 °C and vice versa |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Control Interfaces | IEEE-488, RS232, Ethernet |
| Display | Touchscreen Windows®-based HMI |
| Defrosting | Automatic hot-gas defrost |
| Electrostatic Protection | ESD-safe enclosure design |
| Compliance | Designed for GLP/GMP environments |
| Brand | inTEST–Temptronic |
|---|---|
| Origin | USA |
| Model | TP04310 |
| Temperature Range | −80 °C to +225 °C |
| Airflow Output | 4–18 scfm (1.8–8.5 L/s) |
| Transition Rate | <10 s from −55 °C to +125 °C and vice versa |
| Temperature Accuracy | ±1 °C (NIST-traceable calibration) |
| Temperature Resolution | 0.1 °C |
| Sensor Type | T-type or K-type thermocouple |
| Remote Interface | IEEE-488 (GPIB), RS-232 |
| Dimensions (W×D×H) | 61 × 72.4 × 108 cm |
| Weight | 236 kg |
| Operating Height Range | 69.1–130.3 cm (extendable to 81.3–188 cm) |
| Sound Pressure Level | <65 dBA |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -40°C to +150°C (empty load) |
| Humidity Range | 20–98% RH |
| Temperature Stability | ±0.3°C |
| Humidity Accuracy | +2 / -3% RH |
| Temperature Uniformity | ±2.0°C |
| Heating Rate | ~10 min (20°C → 150°C) |
| Cooling Rate | ~30 min (20°C → -20°C) |
| Internal Dimensions | 1000 × 1000 × 1000 mm (L×W×H) |
| External Dimensions | 1700 × 1450 × 1850 mm (L×W×H) |
| Inner Liner | Mirror-finish SUS#304 stainless steel |
| Outer Casing | Brushed-finish SUS#304 stainless steel |
| Insulation | High-density rigid PU foam + 24K glass wool |
| Refrigeration System | Hermetically sealed French Tecumseh compressor |
| Refrigerant | Eco-friendly R-404A or equivalent |
| Control System | Touchscreen HMI with bilingual (EN/CN) interface, 120 programs × 1200 segments, PID + BTHC (Balance Thermal & Humidity Control) algorithm |
| Sensor | Dual PT-100 platinum resistance thermometers |
| Resolution | 0.1°C / 0.1% RH |
| Data Logging | Built-in runtime counter, fault diagnostics, and event-triggered alarm history |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±1.5°C |
| Temp. Stability | ±0.5°C |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2% RH |
| Heating Rate | ~3°C/min (avg.) |
| Cooling Rate | ~1°C/min (avg.) |
| Internal Dimensions | 50 × 60 × 50 cm (W×H×D) |
| External Dimensions | 102 × 147 × 108 cm (W×H×D) |
| Construction | SUS304 Stainless Steel Interior |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration System | Dual-Stage Cascade (R404A/R23) |
| Control System | TEMI Programmable PID+SSR Microprocessor Controller |
| Compressor Type | Hermetic or Semi-Hermetic (Imported OEM Units) |
| Critical Components | Sporlan Expansion Valves & Filters, Castel Solenoid Valves, Alco Oil Separators, Ranco Pressure Controls |
| Cooling Method | Air-Cooled or Water-Cooled (Optional for High-Capacity Units) |
| Defrost Mode | Automatic & Manual Cycles |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Standards Compliance | IEC 60068-2-14, MIL-STD-810G Method 503.5, ASTM D6987, GB/T 2423.22–2022, GJB 150.5A–2009, QC/T 17–1992, EIA-364-32 |
| Cooling System | Dual-Stage Cascade Refrigeration (Water-Cooled) |
| Temperature Range | –65 °C to +180 °C |
| Transition Time (Typ.) | ≤30 s (–65 °C ↔ +180 °C) |
| Internal Volume Options | 150 L, 300 L, 500 L, 800 L |
| Control Accuracy | ±0.5 °C (Steady State), ±2.0 °C (Transition) |
| Humidity Control | Not Applicable (Dry Thermal Shock Only) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Dual-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Temperature Range | −65°C to +200°C |
| Transition Time (Typical) | ≤15 s between Chambers |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −65 °C to +180 °C |
| Transition Time (Typical) | ≤15 s between chambers |
| Shock Cycle Count | 1–9999 programmable |
| Dwell Time per Zone | 0.1–999.9 h |
| Data Logging Interval | 3 s to 1 h |
| Storage Capacity | 120 days @ 60 s sampling |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Twin-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Compliance | GB/T 2423.1/2/22, GJB 150.3–150.5, IEC 60068-2-14, US MIL-STD-810G Method 503.5, ASTM D648, ISO 11359-2 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | –70°C to +180°C |
| Shock Transition Time (5%–95%) | ≤15 s (between zones) |
| Cycle Count Range | 1–9999 cycles |
| Dwell Time per Zone | 0.1–999.9 h |
| Control System | PID-based LED Touch HMI with Real-Time Curve Display |
| Compliance | ASTM D573, ISO 16750-4, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Cooling System | Twin-stage cascade refrigeration (R404A/R23), equipped with French Tecumseh compressors |
| Defrost Mode | Automatic or Manual, programmable frequency |
| Structural Design | Explosion-proof ergonomic handles, insulated stainless-steel chamber walls, dual- or tri-zone configuration (selectable) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Cooling Medium | Eco-Friendly R404A/R23 Cascade Refrigerant |
| Control Interface | LCD Touchscreen with Dialog-Based UI |
| Construction | Stainless Steel + Pre-Painted Galvanized Steel Panels |
| Air Circulation | Horizontal Centrifugal Forced-Air System with Vertical Heat Exchange |
| Safety Features | Over-Temperature/Over-Current Protection, Power-Fail Memory, Real-Time Fault Logging & Diagnostic Guidance |
| Refrigeration Architecture | Dual-Stage Cascade Cryogenic System with Zone-Specific Compressor Optimization |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Cooling System | Two-Stage Cascade Refrigeration with Imported Semi-Hermetic Compressor (Germany) |
| External Cooling Requirement | 10 m³/h Recirculating Cooling Tower (User-Supplied) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Compliance | GB/T 2423.22-2002, IEC 60068-2-14, GJB 150.5-2009, MIL-STD-810H Method 503.5, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Cooling System | Twin-Stage Cascade Refrigeration (German Semi-Hermetic Compressors) |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.3–150.5, GJB 360.7, GJB 367.2, IEC 60068-2-14, SJ/T 10186–10187, QC/T 17, EIA-364-32 |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Temperature Range | −65 °C to +150 °C |
| Transition Time (−65 °C ↔ +150 °C) | ≤15 min (typical, per chamber-to-chamber transfer) |
| Key | Temperature Range: -40 °C to +100 °C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±5% RH |
| Ramp Rate (Heating) | ~4.0 °C/min |
| Ramp Rate (Cooling) | ~1.0 °C/min |
| Construction | Interior & Exterior – SUS304 Stainless Steel, Matte Finish |
| Insulation | High-Density Polyisocyanurate Foam (HFO-blown, Low-GWP) |
| Cooling System | Air-Cooled, Single-Stage Compressor (for -20 °C), Dual-Stage Compressor (for -40 °C to -70 °C) |
| Door Configuration | Dual-Facing Front & Rear Access Doors |
| Sample Mounting | LCD-Adjustable Tilt Fixture |
| Sensor Placement | Directly in Test Zone (Not in Air Duct) |
| Compliance Support | JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, AEC-Q200, IPC-9701, IPC-J-STD-020 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control Interface | 7-inch LCD with Bilingual (English/Chinese) UI |
| Program Storage | 120 user-defined profiles |
| Max Cycles | 9,999 |
| Max Segment Duration | 999 hrs 59 min |
| Communication | RS-232 with PC software for remote programming, data logging, and real-time monitoring |
| Temperature Transition Mode | Dual-chamber (hot/cold) or single-chamber with air flap switching |
| Recovery Time | ≤5 min (from −40 °C to +150 °C or vice versa) |
| Airflow Actuation | ≤10 s |
| Analog Output | 4–20 mA or 0–10 V DC for external recorder integration |
| Refrigeration | Twin-circuit cascade system with HFC-404A/HFC-134a eco-friendly refrigerant |
| Compressor | Imported semi-hermetic units (Europe/USA) |