| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PCR 3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | Stainless Steel |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PCR2 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–5.00 mL/min |
| Reaction Coil Material | PEEK |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo AS |
| Instrument Type | Liquid Chromatography Autosampler |
| Compliance | Designed for ASTM D4790, USP <621>, and ISO 17025-accredited laboratories |
| Brand | Lab-Antech (formerly LABA Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 0.1–500 µL |
| Autosampler Temperature Control | 4–40 °C |
| Post-Column Reactor Temperature Range | Ambient to 200 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | 10 µL |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8170 |
| Instrument Type | Differential Refractometer Detector (RID) |
| Wavelength Range | 190–900 nm |
| Detection Method | Dual-Beam |
| Light Source | Deuterium Lamp |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | WA2002SF |
| Pricing | Available Upon Request |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 2000 |
| Instrument Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam |
| Light Source | Deuterium Lamp |
| Spectral Scanning Capability | Yes |
| Flow Cell Options | Stainless Steel & Kel-F (Chemically Inert, Biocompatible) |
| Programmable Peak Detection | Yes |
| Baseline Correction Algorithm | Adaptive |
| Lamp Access | Side-Mounted for Quick Replacement |
| Flow Cell Access | Side-Mounted for Tool-Free Exchange |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8110 Plus |
| Instrument Type | Quaternary Pump (Note: “Six-solvent pump” in source is inconsistent with “quaternary” specification |
| Price Range | USD 7,000 – 14,000 (converted at ~¥7.2/USD) |
| Brand | LABA |
|---|---|
| Model | SeriesII |
| Type | Isocratic Pump |
| Flow Rate Range | Up to 40 mL/min |
| Drive Mechanism | Microstepping Stepper Motor |
| Control Interface | LED Display + Keypad |
| Warranty | 3 Years |
| Origin | USA |
| Category | HPLC Accessory / Isocratic Solvent Delivery System |
| Compliance | Designed for GLP-compliant laboratories, compatible with ASTM D5279 and ISO 13877 workflows for liquid chromatographic method validation |
| Brand | LABA |
|---|---|
| Model | PC2001 |
| Origin | USA |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.01–100.00 mL/min |
| Maximum Pressure | 0–6000 psi |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–80 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Model | SeriesIII |
| Flow Rate Range | 0.01–100 mL/min (typical for preparative constant-flow pumps) |
| Pressure Rating | Up to 400 bar |
| Power Supply | 100/110 V or 220 V, 50/60 Hz |
| Interface | RS-232 |
| Pump Head | Sapphire-plated plunger with auto-cleaning mechanism |
| Pulse Damping | Patented low-dead-volume pulse damping technology |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC4006 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 10,000 psi |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient +10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Model | Q-Grad |
| Pump Type | Quaternary High-Pressure Gradient Pump |
| Flow Range | 1 µL/min – 20 mL/min |
| Gradient Composition | Up to 4 Solvents, Independently Controlled |
| Mixing Architecture | High-Pressure Binary/Quaternary Blending (No Low-Pressure Mixer or Online Degasser Required) |
| Dead Volume | Minimized via Integrated Direct High-Pressure Mixing |
| Bubble-Free Operation | Achieved through Positive-Displacement Plunger Design and Solvent Compressibility Compensation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-4000 |
| Pricing | Upon Request |
| Flow Rate | 0.01–20 mL/min |
| Maximum Pressure | 0.0–6000 psi |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Baseline Drift | ≤2 × 10⁻⁴ AU/h |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECADE II |
| Pricing | Upon Request |
| Detector Type | Electrochemical Detector (ED) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC2001 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–20.000 mL/min (configurable for 10 mL/min or 80 mL/min total flow via pump head interchange) |
| Maximum Pressure | 6000 psi |
| Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Pressure Accuracy | ±1% of full-scale pressure |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Baseline Noise | <±1.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/hr |
| Wavelength Accuracy | ±1.0 nm |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | G5 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Temperature Control Range | Ambient to 850 °C |
| Oven Ramp Rate | 0.01–500 °C/min |
| Oven Cool-down Rate | ~1 min (850 °C → 0 °C) |
| Carrier Gas Flow Range & Control | 0–25,000 mL/min |
| Carrier Gas Pressure Range & Control | 0.001–100,000 psi |
| Injector Maximum Operating Temperature | 850 °C |
| Injector Pressure Setting Range | 0.001–100,000 psi |
| Injector Total Flow Setting Range | 0.0001–10,000 mL/min |
| Detector Sensitivity (ECD) | ≤10⁻¹⁵ g/s (for γ-HCH) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UP2000 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) with Online Solid-Phase Extraction (SPE) |
| Flow Rate Range | 0.001–20 mL/min |
| Maximum System Pressure | 25,000 psi |
| Autosampler Tray Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +10 °C to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHEODYNE 7725i |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFC-24 |
| Price Range | USD 2,800 – 7,000 |
| Pump Type | Single-Channel High-Pressure Pump |
| Operating Modes | Constant Flow & Constant Pressure |
| Temperature Control | Peltier-based Active Cooling System |
| Communication Interface | RS-232 |
| Remote Control | Start/Stop via TTL or Dry Contact |
| Pressure Monitoring | Real-time Digital Readout with Setpoint Adjustment |
| Compliance | Designed for SFC Method Development per ASTM D7042 & ISO 16063 |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | OV3000 |
| Temperature Control | Active Cooling & Heating |
| Capacity | ≥6 analytical columns (e.g., 4.6 × 250 mm) or ≥2 semi-preparative columns (up to 300 mm length) |
| Safety | Leak-activated automatic power cutoff |
| Control System | Dual 3-digit microprocessor-based PID controller with independent setpoint and display |
| Construction | Insulated stainless-steel chamber with optimized thermal conduction architecture |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-2 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | PEEK |
| Brand | Labo (Tianjin Labo / LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QLABPro |
| Price Range | USD $26,000–$39,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 12 or 20 vessels |
| Microwave Source | Magnetron |
| Max Temperature | 230 °C (standard mode) / 400 °C (high-temp mode) |
| Max Pressure | 500 psi |
| Exhaust Flow Rate | 150 CFM |
| Output Power | Up to 1200 W |
| Safety Features | Spring-loaded interlocked door, overpressure venting, real-time per-vessel T/P monitoring, thermal runaway detection, PTFE-coated cavity |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | Series 8000 |
| HPLC Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | 9000 psi |
| Flow Precision | <0.1% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–3 mL |
| Column Oven Temperature Range | (Ambient + 20°C) to 200°C |
| UV/Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |