- All
- Favorite
- Popular
- Most rated
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | WA2002SF |
| Pricing | Available Upon Request |
| Brand | LABA |
|---|---|
| Model | PC2001 |
| Origin | USA |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.01–100.00 mL/min |
| Maximum Pressure | 0–6000 psi |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–80 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Detector Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC4006 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 10,000 psi |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient +10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-4000 |
| Pricing | Upon Request |
| Flow Rate | 0.01–20 mL/min |
| Maximum Pressure | 0.0–6000 psi |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Baseline Drift | ≤2 × 10⁻⁴ AU/h |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC2001 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–20.000 mL/min (configurable for 10 mL/min or 80 mL/min total flow via pump head interchange) |
| Maximum Pressure | 6000 psi |
| Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Pressure Accuracy | ±1% of full-scale pressure |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Baseline Noise | <±1.0×10⁻⁵ AU |
| Baseline Drift | <2.0×10⁻⁴ AU/hr |
| Wavelength Accuracy | ±1.0 nm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UP2000 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) with Online Solid-Phase Extraction (SPE) |
| Flow Rate Range | 0.001–20 mL/min |
| Maximum System Pressure | 25,000 psi |
| Autosampler Tray Capacity | 120 positions |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +10 °C to 150 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | Series 8000 |
| HPLC Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | 9000 psi |
| Flow Precision | <0.1% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0–3 mL |
| Column Oven Temperature Range | (Ambient + 20°C) to 200°C |
| UV/Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–19.98 mL/min |
| Gradient Accuracy | ±0.1% |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Baseline Drift | 2 × 10⁻⁴ AU/hr |
| Detector | SSI Model 500 UV-Vis Variable Wavelength Detector |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Pricing | Available Upon Request |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–9.99 mL/min |
| Flow Accuracy | ±0.1% |
| Baseline Noise (UV-VIS) | 0.2 × 10⁻⁵ AU |
| Baseline Drift (UV-VIS) | 2 × 10⁻⁴ AU/hr |
| Pump Technology | SSI III Dual-Piston Positive Displacement with Patented Online Self-Cleaning Mechanism |
| Upgrade Path | Compatible with Second Pump for Binary Gradient Configuration |
| Detector Standard | Model 500 UV-Vis Variable Wavelength Detector (190–700 nm) |
| Software | LabAlliance Chromatography Data System (CDS) with Audit Trail & Electronic Signature Support per FDA 21 CFR Part 11 |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–40 mL/min |
| Maximum Pressure | 6000 psi |
| Sample Injection Positions | 120 |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 99 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 100 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lanbo |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cathodeon |
| Pricing | Available Upon Request |
Show next