- All
- Favorite
- Popular
- Most rated
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PCR 3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | Stainless Steel |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PCR2 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–5.00 mL/min |
| Reaction Coil Material | PEEK |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo AS |
| Instrument Type | Liquid Chromatography Autosampler |
| Compliance | Designed for ASTM D4790, USP <621>, and ISO 17025-accredited laboratories |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8170 |
| Instrument Type | Differential Refractometer Detector (RID) |
| Wavelength Range | 190–900 nm |
| Detection Method | Dual-Beam |
| Light Source | Deuterium Lamp |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 2000 |
| Instrument Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–900 nm |
| Optical Design | Dual-Beam |
| Light Source | Deuterium Lamp |
| Spectral Scanning Capability | Yes |
| Flow Cell Options | Stainless Steel & Kel-F (Chemically Inert, Biocompatible) |
| Programmable Peak Detection | Yes |
| Baseline Correction Algorithm | Adaptive |
| Lamp Access | Side-Mounted for Quick Replacement |
| Flow Cell Access | Side-Mounted for Tool-Free Exchange |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8110 Plus |
| Instrument Type | Quaternary Pump (Note: “Six-solvent pump” in source is inconsistent with “quaternary” specification |
| Price Range | USD 7,000 – 14,000 (converted at ~¥7.2/USD) |
| Brand | LABA |
|---|---|
| Model | SeriesII |
| Type | Isocratic Pump |
| Flow Rate Range | Up to 40 mL/min |
| Drive Mechanism | Microstepping Stepper Motor |
| Control Interface | LED Display + Keypad |
| Warranty | 3 Years |
| Origin | USA |
| Category | HPLC Accessory / Isocratic Solvent Delivery System |
| Compliance | Designed for GLP-compliant laboratories, compatible with ASTM D5279 and ISO 13877 workflows for liquid chromatographic method validation |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Model | Q-Grad |
| Pump Type | Quaternary High-Pressure Gradient Pump |
| Flow Range | 1 µL/min – 20 mL/min |
| Gradient Composition | Up to 4 Solvents, Independently Controlled |
| Mixing Architecture | High-Pressure Binary/Quaternary Blending (No Low-Pressure Mixer or Online Degasser Required) |
| Dead Volume | Minimized via Integrated Direct High-Pressure Mixing |
| Bubble-Free Operation | Achieved through Positive-Displacement Plunger Design and Solvent Compressibility Compensation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECADE II |
| Pricing | Upon Request |
| Detector Type | Electrochemical Detector (ED) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHEODYNE 7725i |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFC-24 |
| Price Range | USD 2,800 – 7,000 |
| Pump Type | Single-Channel High-Pressure Pump |
| Operating Modes | Constant Flow & Constant Pressure |
| Temperature Control | Peltier-based Active Cooling System |
| Communication Interface | RS-232 |
| Remote Control | Start/Stop via TTL or Dry Contact |
| Pressure Monitoring | Real-time Digital Readout with Setpoint Adjustment |
| Compliance | Designed for SFC Method Development per ASTM D7042 & ISO 16063 |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | OV3000 |
| Temperature Control | Active Cooling & Heating |
| Capacity | ≥6 analytical columns (e.g., 4.6 × 250 mm) or ≥2 semi-preparative columns (up to 300 mm length) |
| Safety | Leak-activated automatic power cutoff |
| Control System | Dual 3-digit microprocessor-based PID controller with independent setpoint and display |
| Construction | Insulated stainless-steel chamber with optimized thermal conduction architecture |
| Compliance | Designed for GLP-compliant chromatography workflows |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-2 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | PEEK |
| Brand | LABA (Tianjin Lanbo) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DDL301 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 190–900 nm |
| Detection Method | Photomultiplier Tube (PMT) |
| Light Source | High-Intensity Halogen Lamp |
| Evaporation Principle | Low-Temperature Nebulization & Drift Tube Evaporation |
| Compatibility | HPLC, UHPLC, and LC-MS Coupling |
| Detection Sensitivity | Mass-sensitive, independent of chromophore, fluorophore, or electrochemical activity |
| Gradient Compatibility | Fully compatible with gradient elution |
| Baseline Stability | High resistance to flow rate and temperature fluctuations |
| Physical Footprint | Compact benchtop design (W × D × H: 240 × 450 × 320 mm) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LB8131 |
| Price Range | USD 2,800 – 7,000 |
| Temperature Control | Active Cooling & Heating via Thermoelectric (Peltier) Module |
| Brand | SSI |
|---|---|
| Origin | USA |
| Model | SeriesIII |
| Pump Type | Isocratic (Single-Solvent) HPLC Pump |
| Construction | Stainless Steel Flow Path with Optional PEEK Fittings |
| Pressure Protection | Dual High/Low-Pressure Limit Shutdown |
| Control Interface | Front-Panel Keypad + LED Display + RS-232 Serial Port |
| Self-Cleaning Capability | Integrated Pump Head Flush Function + Quick-Release Drain Valve |
| Flow Path Design | Dual Check Valve Architecture |
| Seal Maintenance | Tool-Free Seal Ring Replacement |
| Operational Duty | Continuous Duty Rated for Stable Flow Delivery |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Fract R1 |
| Instrument Type | Gas-Phase-Compatible Fraction Collector |
| Control Modes | Time-Based, Drop-Count-Based, Peak-Triggered (UV/Analog Signal Input) |
| Collection Capacity | Up to 96 Tubes (Standard Rack Configuration) |
| Dimensions | 320 × 300 × 280 mm |
| Weight | 8.2 kg |
| Brand | Laba (Tianjin Laba Co., Ltd.) |
|---|---|
| Origin | USA |
| Model | PCR3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Pump Type | High-Precision Syringe-Type Piston Pump |
| Control Interface | Front-panel Keypad + PC via USB/RS-232 |
| Safety Features | Overpressure Shutdown, Leak Detection, Thermal Overload Protection |
| Reagent Delivery | Pressurized N₂-driven with Adjustable Flow Regulation and Splitting |
| Reactor Options | Modular, Customizable Volume (Standard: 0.5–5 mL), Multi-directional Mixing Geometry |
| Fluidic Path | Fully Chemically Inert (PEEK, Sapphire, Hastelloy C-276) |
| Cleaning | Integrated On-Line Solvent Flush Routine |
| Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lanbo |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Capacity | 120 vials (3 trays), 105 vials under refrigeration |
| Injection Precision | <0.1% RSD @ 5 µL and @ 10 µL |
| Injection Volume Range | 0.1–100 µL (standard 250 µL loop) |
| Sample Temperature Control | Peltier-based cooling/heating, 0–60 °C in 1 °C increments |
| Vial Mixing/Heating | Pneumatic vortex mixer + heater per vial, 1 °C resolution |
| Dilution Accuracy | <1.0% RSD for 1:1000 dilution (10 µL → 1 mL) |
| Dispensing Accuracy | <0.2% RSD when adding 1 mL solvent externally |
| Method Storage | Protected memory file system |
| Communication Interface | RS-232 |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions | 14.5" H × 16" W × 19.5" D |
| Weight | 35.2 lbs (base unit) |
| Power Supply | 220 V, 50/60 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 6000 |
| Instrument Type | Ultraviolet-Visible (UV-Vis) Diode Array Detector |
| Detection Limit | 0.1 µg/L (typical, based on caffeine in methanol/water, 254 nm) |
| Precision | ≤0.2% RSD (retention time and peak area, n=6) |
| Flow Rate Compatibility | 1 µL/min to 20 mL/min |
| Optical Path Length | 50 mm LightPipe flow cell (patented) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RI2001 |
| Price Range | USD 7,000–14,000 |
| Detector Type | Differential Refractometer (RID) |
| Wavelength Range | 160–1100 nm |
| Measurement Principle | Dual-Beam Optical Null Method |
| Light Source | Deuterium Lamp |
| Temperature Compensation | Automatic Real-Time |
| Data Output | Analog (±1 V, ±5 V, ±10 V) + Digital (RS-232/USB) |
| A/D Resolution | 16-bit |
| Zero Calibration | Motorized Auto-Zero with Solvent Flush Sequence |
| Reference Cell | Self-Cleaning Flow-Through Design |
| Thermal Stability | Integrated Isothermal Enclosure with Active Temperature Control (±0.01 °C) |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | PCR3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Compliance | Fully compatible with all HPLC platforms (Agilent, Waters, Shimadzu, Thermo Fisher, etc.) |
| Control Interface | Dual-mode (front-panel keypad + PC via USB/RS-232) |
| Safety Features | Overpressure shutdown, leak detection, thermal overheat protection |
| Fluidic Architecture | Chemically inert, self-cleaning pump head, pressurized reagent reservoirs with N₂ blanket control |
| Reactor Options | Interchangeable, customizable volume reaction coils (standard: 0.5–5 mL internal volume) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 502 |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelengths | Dual-Programmable |
| Spectral Range | Broad (Typical UV-Vis, e.g., 200–700 nm) |
| Bandwidth Options | Multiple Fixed and Variable Slit Widths |
| Sensitivity | High (Sub-picomolar Detection Limit for Standard Fluorophores) |
| Noise Level | Ultra-Low (RMS < 0.5 mV at 1 s time constant) |
| Scan Mode | Point-Scan Fluorescence Acquisition |
| Spectral Storage Capacity | ≥64 Predefined Method-Linked Spectral Profiles |
| Dynamic Range | >4 Orders of Magnitude (Linear Response from 10⁻¹² to 10⁻⁸ M for quinine sulfate equivalent) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OV2001 / OV2000 |
| Temperature Control | Active Cooling & Heating |
| Safety Features | Over-Temperature Protection |
| Capacity | Accommodates 3–4 Standard HPLC/GC Columns |
| Control Algorithm | Dual-Mode Fuzzy Logic + PID Auto-Tuning |
| Uniformity | ±0.3 °C across column center zone |
| Monitoring | Real-Time Internal Temperature Tracking |
Show next