| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZPY-16 |
| Plate Positions | 16 |
| Pipetting Accuracy | 0.1 mL |
| Pipetting Range | 0.1–999 mL |
| Sample Throughput | 16 samples |
| Pipetting Error | <1% at 5 mL |
| Dispensing Volume Range | 0.1–8000 mL |
| Flow Rate | 5–80 mL/min |
| Power Supply | 100–240 VAC, 50–60 Hz, 75 W |
| Operating System | Android-based HMI |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | ZRS-8G |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 |
| Temperature Range | 5.0 °C (ambient) to 45.0 °C |
| Temperature Accuracy | ≤ ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotational Speed Range | 25–200 rpm |
| Speed Resolution | 1 rpm |
| Speed Stability Error | ≤ ±4% |
| Paddle Wobble Amplitude | ≤ 0.5 mm |
| Basket Wobble Amplitude | ≤ 1.0 mm |
| Shaft-to-Vessel Axis Offset | ≤ 2.0 mm |
| Timer Duration | Up to 99 h 59 min (forward count) |
| Sampling Cycles | Up to 9 programmable cycles |
| Sampling Interval per Cycle | Up to 9 h 59 min (countdown) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | KKJ-100 |
| Instrument Type | Optical Airborne Particle Counter |
| Channel Configuration | 8 configurable channels |
| Particle Size Range | 20–640 µm |
| Maximum Sample Concentration | 100,000 particles/L |
| Accuracy | ≤ ±20% |
| Repeatability | RSD ≤ 5% |
| Sampling Flow Rate | 20–50 L/min (±5%) |
| Standard Flow Rate | 28.3 L/min (1.0 CFM) |
| Sampling Duration | 1–600 min |
| Zero Count Time | ≤ 10 min |
| Internal Data Storage | 3,000 measurement records |
| Display | 7-inch IPS touchscreen |
| Interfaces | USB, RS232 |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤120 W |
| Operating Environment | 0–35 °C, 10–90% RH |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Model | RC-806 |
| Dissolution Vessels | 8 |
| Temperature Range | 5.0 (ambient)–45.0 °C |
| Temperature Accuracy | ±0.3 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | GWF-D1 |
| Instrument Type | Optical Particle Counter |
| Operating System | Android-based embedded platform |
| Compliance Standards | Chinese Pharmacopoeia (ChP) 2020 Edition, USP <788> & <789>, ISO 21510:2018, GB 8368–2018 |
| Particle Detection Principle | Light Blockage (Obscuration) with Dual-Beam Laser Compensation |
| Sample Compatibility | Aqueous & non-aqueous solutions, oils, organic solvents, acidic/alkaline formulations |
| Material Contact Path | 316L stainless steel + PTFE fluidic pathway |
| Sample Volume Range | 0.2–1000 mL (±0.1 mL resolution) |
| Volumetric Accuracy | < ±0.5% |
| Flow Rate | 5–80 mL/min |
| Particle Size Channels | 64 fixed channels + user-definable up to thousands |
| resolution | 0.1 µm |
| Size Range | 1–500 µm |
| Counting Range | 0–9,999,999 particles per sample |
| Counting Accuracy | ±5% of reference value |
| Channel Resolution | >95% |
| RSD | <1.5% (for ≥1000 particles/mL standard suspension) |
| Max Detectable Concentration | 18,000 particles/mL |
| Stirring Speed | 0–1000 rpm |
| Ambient Operating Temperature | 10–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, <80 W |
| Data Interfaces | RS232, USB host/device, thermal printer port |
| Data Storage | Onboard SQLite database with statistical analysis engine |
| Security | Role-based user authentication with audit trail logging |
| Enclosure | Sealed optical chamber with dust-proof sliding access door |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FD |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Capacity | 1–20 positions |
| Sample Volume | 60 µL (50–100 µL typical) |
| Test Time | < 1.5 min per sample |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 5–35°C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Dimensions | 280 × 443 × 434 mm |
| Language Support | English & Chinese |
| Connectivity | RS232, USB, Barcode Scanner Interface |
| Compliance | Designed to support pharmacopeial testing per Chinese Pharmacopoeia (ChP) requirements |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GWF-9D |
| Instrument Type | Optical Particle Counter |
| Price | Upon Request |
| Key Specifications | Particle Size Range: 1–500 µm |
| Counting Channels | 64 displayed (customizable up to thousands, resolution 0.01 µm) |
| Sample Volume | 0.2–6500 mL (±0.5% accuracy) |
| Flow Rate | 5–80 mL/min |
| Counting Accuracy | ±5% of specified value |
| Channel Resolution | >95% |
| RSD | <1.5% (for standard particles ≥1000 particles/mL) |
| Max Detection Concentration | 18,000 particles/mL |
| Sample Capacity | 1–20 vials |
| Stirring Speed | 0–1000 rpm (step-adjustable) |
| Operating Temperature | 10–40 °C |
| Power | 100–240 VAC, 50/60 Hz, <80 W |
| Data Output | Dot-matrix printer, RS232, USB storage |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FS |
| Measurement Principle | Freezing Point Depression |
| Temperature Control System | Dual-stage Peltier Cooling |
| Sample Volume | 50–100 µL |
| Calibration | Multi-point, User-defined Calibration Curves |
| Operating System | Android-based Embedded OS |
| Data Storage | Internal SSD with >100,000 Test Record Capacity |
| Compliance Features | Audit Trail, Electronic Signature (21 CFR Part 11 Ready), Role-Based Access Control |
| Connectivity | RS232, USB Host (for keyboard/mouse/scanner), Built-in Thermal Printer |
| Noise Level | <45 dB(A) |
| Pharmacopeia Integration | Preloaded Chinese Pharmacopoeia (ChP) Monographs for >300 Injectable Products |
| Maintenance | Dry-Cooling Architecture (No Heat Transfer Fluid Required) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-R |
| Instrument Type | Optical Particle Counter |
| Operating System | Android-based embedded platform |
| Compliance | USP <788>, USP <789>, ChP 2025 (General Chapter 0903), ISO 21510, FDA 21 CFR Part 11 |
| Calibration Standards | NIST-traceable latex particle suspensions |
| Sample Compatibility | Aqueous & non-aqueous injectables, sterile powders, infusion devices, lipid emulsions |
| Detection Principle | Light Blockage (Light Obscuration) |
| Particle Size Channels | 64 fixed + user-definable (down to 0.1 µm resolution) |
| Size Range | 1–500 µm (segmented sensor configuration) |
| Count Range | 0–9,999,999 particles per sample |
| Sample Volume | 0.2–1000 mL (±0.1 mL resolution) |
| Volume Accuracy | < ±0.5% |
| Flow Rate | 5–80 mL/min |
| Counting Accuracy | ±5% of reference value |
| Channel Resolution | >95% (per ISO 21501-4) |
| RSD | <1.5% (for ≥1000 particles/mL standard suspension) |
| Max Detectable Concentration | 18,000 particles/mL |
| Stirring Speed | 0–1000 rpm |
| Ambient Operating Temperature | 10–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, <80 W |
| Data Interfaces | RS232, USB host/device, thermal printer port |
| Storage | Internal database with timestamped audit trail, GLP-compliant metadata tagging |
| Software Features | Batch management, statistical reporting (mean, SD, CV, histogram, cumulative distribution), trend analysis, electronic signature support |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-8JA |
| Pricing | Available Upon Request |
| Principle | Light Obscuration (LO) with Laser Detection |
| Compliance | Fully Aligned with Chinese Pharmacopoeia (ChP) 2020 Edition, General Chapter 0903 |
| Sample Types | Sterile Injectable Solutions, Lyophilized Powders, Concentrated Injection Solutions |
| Detection Range | 1–500 µm (Configurable Channel Segments) |
| Channel Settings | ≥2 µm, 4–6 µm, ≥5 µm, ≥8 µm, ≥10 µm, ≥12 µm, ≥25 µm, ≥100 µm |
| Count Range | 0–9,999,999 particles per sample |
| Max. Particle Concentration | <10,000 particles/mL |
| Sample Volume | 0.2–1000 mL (5 mL accuracy: ±0.5%) |
| Flow Rate | 5–80 mL/min (adjustable) |
| Measurement Accuracy | ±10% of reference value |
| Channel Resolution | >95% |
| RSD | <2% (for standard latex particles ≥1000 particles/mL) |
| Stirring Speed | 0–2000 rpm (propeller-type, frictionless, programmable) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤100 W |
| Display | Large LCD with Chinese GUI |
| Data Handling | Onboard storage, USB export, LAN connectivity, optional integration with LIMS or ELN platforms |
| Preloaded Drug Library | >300 ChP-listed injectables |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-A2 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | SKJ-A |
| Instrument Type | Optical Particle Counter |
| Particle Size Channels | 64 (0.001 µm resolution) |
| Size Ranges (Selectable) | 0.5–25 µm, 1–150 µm, 2–150 µm, 5–200 µm, or 10–500 µm |
| Count Range | 0–9,999,999 particles per sample |
| Sample Volume | 0.2–6500 mL (0.1 mL resolution) |
| Sampling Volume Error | ≤ ±3% at 5 mL |
| Flow Rate | 5–80 mL/min |
| Counting Accuracy | ≤ ±20% of reference value |
| Relative Standard Deviation (RSD) | ≤ 2% (for standard particles ≥1000 particles/mL) |
| Maximum Detectable Concentration | 18,000 particles/mL |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V, 50/60 Hz, ≤80 W |
| Material Compatibility | 316L stainless steel + PTFE wetted path |
| Data Interface | RS232, USB |
| Compliance Features | Audit trail, user permission management, automated calibration & cleaning |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-7JA |
| Pricing | Available Upon Request |
| Light Source | High-Performance Laser |
| Detection Principle | Light Obscuration (LO) |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Formulations |
| Sample Volume Range | 1–6000 mL (0.1 mL incremental step) |
| Volume Accuracy | ≤ ±0.5% (2–1000 mL) |
| Syringe Options | 5 mL, 10 mL, 25 mL |
| Flow Rate | 5–160 mL/min (user-adjustable) |
| Particle Size Channels | 2–3 µm, 3–4 µm, 4–6 µm, 5–6 µm, ≥5 µm, ≥10 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm, 20 µm |
| Customizable Channel Range | 1–500 µm (segmented selection) |
| Count Range | 0–999,999 particles per sample |
| Counting Accuracy | < ±5% of certified reference value |
| RSD | < 1.5% (for standard particles ≥1000 counts) |
| Coincidence Error | < 5% at 10,000 particles/mL |
| Stirring Mechanism | Frictionless Propeller-Type Agitator, 0–2000 rpm (adjustable) |
| Display | Large Backlit LCD with Multi-Channel Real-Time Data & Histogram Overlay |
| Preloaded Database | >300 USP/ChP-Listed Pharmaceuticals & Medical Devices |
| Compliance | GB 8368–2018, Chinese Pharmacopoeia (2020 Edition), ISO 21501-4, USP <788>, USP <789>, EP 2.9.19 |
| Connectivity | RS232 Interface for LIMS/Lab Platform Integration |
| Power Supply | AC 220 V ±10%, 50 Hz, <100 W |
| Operating Temperature | 10–40 °C |
| Wetted Materials | 316L Stainless Steel + PTFE (for syringe, slit, and fluidic path) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C-1 |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–70 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤ 400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Ambient Temp. | 10–30 °C |
| Ambient Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Dimensions | 220 × 210 × 360 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-8JDS |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SKJ-1 |
| Instrument Type | Optical Particle Counter |
| Particle Size Range | 0.1–2 µm / 0.2–5 µm / 0.5–25 µm |
| Number of Detection Channels | 8 |
| Default Channel Sets (µm) | [0.1, 0.15, 0.2, 0.25, 0.3, 0.5, 1.0, 2.0] |
| Sample Flow Rate | 10–80 mL/min |
| Test Duration (Online Mode) | 1–999 s |
| Sample Volume (Offline Mode) | 1–999 mL |
| Maximum Particle Concentration | 20,000 particles/mL |
| Maximum Operating Pressure (Online) | 0.7 MPa |
| Connection Thread | 1/4-28 UNF |
| Electrostatic Discharge Protection | ≥2 kV |
| Internal Data Storage Capacity | 10,000 measurement records |
| Power Supply | AC 80–305 V, ≤30 W |
| Display | 7-inch TFT LCD |
| Dimensions (L×W×H, excluding protrusions) | 285 × 280 × 293 mm |
| Weight | 6 kg |
| Operating Temperature | 10–50 °C |
| Operating Humidity | 10–90 % RH (non-condensing) |
| Interface Options | USB, RS-232, TCP/IP |
| Compliance | CE-marked design principles |
| compatible with ISO 11171 | 2016 reference calibration protocols |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Model | SKJ-FS/F |
| Operating System | Android-based Embedded Platform |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Particle Channel Resolution | 0.1 µm |
| Size Range Options | 1–150 µm, 2–150 µm, 5–200 µm, or 25–500 µm (sensor-dependent selection) |
| Counting Channels | 64 user-configurable bins |
| Counting Range | 0–9,999,999 particles per sample |
| Sample Volume | 0.2–1000 mL (0.1 mL resolution) |
| Volume Accuracy | ±3% |
| Flow Rate | 5–80 mL/min |
| Counting Accuracy | ±20% of reference value |
| Precision (RSD) | ≤2% (for standard latex particles ≥1000 particles/mL) |
| Maximum Detectable Concentration | 18,000 particles/mL |
| Stirring Speed | 0–1000 rpm (step-adjustable) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V, 50/60 Hz, ≤80 W |
| Sample Path Materials | 316L stainless steel + PTFE |
| Data Integrity Features | Audit Trail, Role-Based Access Control (RBAC), Electronic Signature Support |
| Connectivity | RS232, USB host/device |
| Storage | Internal database with statistical analysis engine |
| Enclosure | Dust-protected transparent access door |
| Calibration | Fully automated on-board calibration routine |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | KKJ-01/03 |
| Instrument Type | Optical Particle Counter |
| Measurement Range | 0.1–5 μm or 0.3–10 μm |
| Channel Count | 8 |
| Maximum Sample Concentration | 100,000 particles/L |
| Counting Efficiency | 50±20% at 0.1 μm |
| Repeatability | ≤10% |
| Size Distribution Error | ≤±30% at 0.5 μm and 5 μm |
| Timing Accuracy | ≤1 s over 6 min |
| Particle Concentration Indication Error | ≤30% at 0.5 μm |
| Clean-up Time | ≤10 min (three consecutive zero counts with 95% confidence) |
| Sampling Flow Rate | 1.0 CFM (28.3 L/min) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤120 W |
| Interfaces | Ethernet, RS232 |
| Internal Data Storage | 3,000 sample records |
| Dimensions | 305 × 315 × 385 mm |
| Operating Environment | 0–35 °C, 10–90% RH |
| Display | 7-inch IPS touchscreen |
| Compliance | JJF 1190–2008, ISO 21501-4 / GB/T 29024.4 |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SMC 30F |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKJ-W |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Particle Size Range | 1–500 µm (selectable sub-ranges) |
| Channel Count | 256 |
| Counting Accuracy | ±5% of certified reference value |
| Sample Volume Range | 0.2–6500 mL (0.1 mL resolution) |
| Sampling Flow Rate | 5–80 mL/min |
| Volume Error | <±3% |
| Channel Resolution | ≥90% |
| RSD | ≤1.5% (for standard particles ≥1000 particles/mL) |
| Max Detectable Concentration | 18,000 particles/mL |
| Stirring Speed | 0–1000 rpm (magnetic, stepwise adjustable) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 5–80 %RH |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤120 W |
| Data Interfaces | RS232, USB storage, Wi-Fi, LAN |
| Software | Windows-based with 21 CFR Part 11-compliant audit trail, multi-level user accounts, customizable reporting, and embedded database |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | WCP-1 |
| Instrument Type | Optical Particle Counter |
| Particle Detection Principle | Light Obscuration (LO) |
| Counting Channels | 64 programmable channels |
| Adjustable Size Range | 10–100 µm (resolution down to 0.1 µm) |
| Sample Volume | 2–500 mL |
| Volume Accuracy | ±0.5% at 500 mL |
| Counting Accuracy | ±10% |
| Relative Standard Deviation (RSD) | ≤2% (for standard particle suspension ≥1000 particles/mL) |
| Maximum Detectable Concentration | 10,000 particles/mL |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | General Distributor |
| Product Origin | Domestic (China) |
| Model | ZFY |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | ZPY-4A |
| Dispensing Accuracy | ±1% (at 5 mL, metering pump) |
| Dispensing Range | 100 µL – 9999 mL |
| Sample Throughput | 1–3 independent metering pump channels + 1 peristaltic pump channel |
| Dispensing Volume Resolution | 10 µL |
| Pump Speed | Metering Pump: 0.5–200 mL/min |
| Peristaltic Pump | 100–500 mL/min |
| Power Supply | 100–240 VAC, 50/60 Hz, 75 W |
| Operating Temperature | 10–40 °C |
| Fluid Compatibility | Organic and inorganic solvents (compatible with PTFE, PVDF, 316L stainless steel, and zirconia ceramic wetted materials) |
| System OS | Android-based embedded interface |
| Wetted Materials | PTFE, PVDF, 316L SS, zirconia ceramic |