Empowering Scientific Discovery

Tianjin Tianhe Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSMC 30FD
Measurement Range0–3000 mOsmol/kg H₂O
Sample Capacity1–20 positions
Sample Volume60 µL (50–100 µL typical)
Test Time< 1.5 min per sample
Pre-cooling Time≤ 3 min
Resolution1 mOsmol/kg
RepeatabilityRSD ≤ ±1% at 300 mOsmol/kg
Accuracy±2 mOsmol/kg (≤400 mOsmol/kg)
Linearity< 1% deviation from linear fit
Operating Environment5–35°C, 5–80% RH
Power SupplyAC 220 V ±10%, 50 Hz, <80 W
Dimensions280 × 443 × 434 mm
Language SupportEnglish & Chinese
ConnectivityRS232, USB, Barcode Scanner Interface
ComplianceDesigned to support pharmacopeial testing per Chinese Pharmacopoeia (ChP) requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSMC 30FS
Measurement PrincipleFreezing Point Depression
Temperature Control SystemDual-stage Peltier Cooling
Sample Volume50–100 µL
CalibrationMulti-point, User-defined Calibration Curves
Operating SystemAndroid-based Embedded OS
Data StorageInternal SSD with >100,000 Test Record Capacity
Compliance FeaturesAudit Trail, Electronic Signature (21 CFR Part 11 Ready), Role-Based Access Control
ConnectivityRS232, USB Host (for keyboard/mouse/scanner), Built-in Thermal Printer
Noise Level<45 dB(A)
Pharmacopeia IntegrationPreloaded Chinese Pharmacopoeia (ChP) Monographs for >300 Injectable Products
MaintenanceDry-Cooling Architecture (No Heat Transfer Fluid Required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSMC 30C-1
Measurement PrincipleFreezing Point Depression
Range0–3000 mOsmol/kg H₂O
Sample Volume50–70 µL
Test Time< 2 min
Pre-cooling Time≤ 3 min
RepeatabilityRSD ≤ ±1% (at 300 mOsmol/kg)
Accuracy±2 mOsmol/kg (≤ 400 mOsmol/kg)
Resolution1 mOsmol/kg
Linearity< 1% deviation from linear fit
Ambient Temp.10–30 °C
Ambient Humidity5–80% RH
Power SupplyAC 220 V ±10%, 80 W
Dimensions220 × 210 × 360 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTJtianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSMC 30F
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSMC 30D
Measurement PrincipleFreezing Point Depression
Measurement Range0–3000 mOsmol/kg H₂O
Sample Volume50–100 µL
Analysis Time< 90 s
Pre-cooling Time≤ 3 min
RepeatabilityRSD ≤ ±1% at 300 mOsmol/kg
Accuracy±2 mOsmol/kg (≤400 mOsmol/kg)
Resolution1 mOsmol/kg
Linearity< 1% deviation from linear fit
Operating Environment10–30 °C, 5–80% RH
Power SupplyAC 220 V ±10%, 50 Hz, <80 W
Compliance SupportChinese Pharmacopoeia (ChP) injection database built-in
Data InterfaceRS232
Software FeaturesUser permission management, audit-trail-capable data storage, configurable pass/fail criteria, multi-format print output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSMC 30DS
Measurement Range0–3000 mOsmol/kg H₂O
Sample Volume50–100 µL
Analysis Time< 1.5 min
Pre-cooling Time≤ 3 min
RepeatabilityRSD ≤ ±1% at 300 mOsmol/kg
Resolution1 mOsmol/kg
Linearity< 1% deviation from linear fit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSMC 30C
Measurement PrincipleFreezing Point Depression
Range0–3000 mOsmol/kg H₂O
Sample Volume50–100 µL
Test Time< 2 min
Pre-cooling Time≤ 3 min
Resolution1 mOsmol/kg
RepeatabilityRSD ≤ ±1% (at 300 mOsmol/kg)
Accuracy±2 mOsmol/kg (≤400 mOsmol/kg), ±1% (>400 mOsmol/kg)
Linearity< 1% deviation from linear fit
Operating Temperature10–30 °C
Operating Humidity5–80% RH
Power SupplyAC 220 V ±10%, 80 W
Regulatory StatusCertified Medical Device per Chinese NMPA Class II requirements
ComplianceMeets pharmacopoeial specifications in Chinese Pharmacopoeia (2020 Edition), including for injectables, ophthalmic preparations, and osmotic diuretics