- All
- Favorite
- Popular
- Most rated
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | ZRS-8G |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 |
| Temperature Range | 5.0 °C (ambient) to 45.0 °C |
| Temperature Accuracy | ≤ ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotational Speed Range | 25–200 rpm |
| Speed Resolution | 1 rpm |
| Speed Stability Error | ≤ ±4% |
| Paddle Wobble Amplitude | ≤ 0.5 mm |
| Basket Wobble Amplitude | ≤ 1.0 mm |
| Shaft-to-Vessel Axis Offset | ≤ 2.0 mm |
| Timer Duration | Up to 99 h 59 min (forward count) |
| Sampling Cycles | Up to 9 programmable cycles |
| Sampling Interval per Cycle | Up to 9 h 59 min (countdown) |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Model | RC-806 |
| Dissolution Vessels | 8 |
| Temperature Range | 5.0 (ambient)–45.0 °C |
| Temperature Accuracy | ±0.3 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FD |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Capacity | 1–20 positions |
| Sample Volume | 60 µL (50–100 µL typical) |
| Test Time | < 1.5 min per sample |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 5–35°C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Dimensions | 280 × 443 × 434 mm |
| Language Support | English & Chinese |
| Connectivity | RS232, USB, Barcode Scanner Interface |
| Compliance | Designed to support pharmacopeial testing per Chinese Pharmacopoeia (ChP) requirements |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30FS |
| Measurement Principle | Freezing Point Depression |
| Temperature Control System | Dual-stage Peltier Cooling |
| Sample Volume | 50–100 µL |
| Calibration | Multi-point, User-defined Calibration Curves |
| Operating System | Android-based Embedded OS |
| Data Storage | Internal SSD with >100,000 Test Record Capacity |
| Compliance Features | Audit Trail, Electronic Signature (21 CFR Part 11 Ready), Role-Based Access Control |
| Connectivity | RS232, USB Host (for keyboard/mouse/scanner), Built-in Thermal Printer |
| Noise Level | <45 dB(A) |
| Pharmacopeia Integration | Preloaded Chinese Pharmacopoeia (ChP) Monographs for >300 Injectable Products |
| Maintenance | Dry-Cooling Architecture (No Heat Transfer Fluid Required) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-8JA |
| Pricing | Available Upon Request |
| Principle | Light Obscuration (LO) with Laser Detection |
| Compliance | Fully Aligned with Chinese Pharmacopoeia (ChP) 2020 Edition, General Chapter 0903 |
| Sample Types | Sterile Injectable Solutions, Lyophilized Powders, Concentrated Injection Solutions |
| Detection Range | 1–500 µm (Configurable Channel Segments) |
| Channel Settings | ≥2 µm, 4–6 µm, ≥5 µm, ≥8 µm, ≥10 µm, ≥12 µm, ≥25 µm, ≥100 µm |
| Count Range | 0–9,999,999 particles per sample |
| Max. Particle Concentration | <10,000 particles/mL |
| Sample Volume | 0.2–1000 mL (5 mL accuracy: ±0.5%) |
| Flow Rate | 5–80 mL/min (adjustable) |
| Measurement Accuracy | ±10% of reference value |
| Channel Resolution | >95% |
| RSD | <2% (for standard latex particles ≥1000 particles/mL) |
| Stirring Speed | 0–2000 rpm (propeller-type, frictionless, programmable) |
| Operating Temperature | 10–40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤100 W |
| Display | Large LCD with Chinese GUI |
| Data Handling | Onboard storage, USB export, LAN connectivity, optional integration with LIMS or ELN platforms |
| Preloaded Drug Library | >300 ChP-listed injectables |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-A2 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-7JA |
| Pricing | Available Upon Request |
| Light Source | High-Performance Laser |
| Detection Principle | Light Obscuration (LO) |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Formulations |
| Sample Volume Range | 1–6000 mL (0.1 mL incremental step) |
| Volume Accuracy | ≤ ±0.5% (2–1000 mL) |
| Syringe Options | 5 mL, 10 mL, 25 mL |
| Flow Rate | 5–160 mL/min (user-adjustable) |
| Particle Size Channels | 2–3 µm, 3–4 µm, 4–6 µm, 5–6 µm, ≥5 µm, ≥10 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm, 20 µm |
| Customizable Channel Range | 1–500 µm (segmented selection) |
| Count Range | 0–999,999 particles per sample |
| Counting Accuracy | < ±5% of certified reference value |
| RSD | < 1.5% (for standard particles ≥1000 counts) |
| Coincidence Error | < 5% at 10,000 particles/mL |
| Stirring Mechanism | Frictionless Propeller-Type Agitator, 0–2000 rpm (adjustable) |
| Display | Large Backlit LCD with Multi-Channel Real-Time Data & Histogram Overlay |
| Preloaded Database | >300 USP/ChP-Listed Pharmaceuticals & Medical Devices |
| Compliance | GB 8368–2018, Chinese Pharmacopoeia (2020 Edition), ISO 21501-4, USP <788>, USP <789>, EP 2.9.19 |
| Connectivity | RS232 Interface for LIMS/Lab Platform Integration |
| Power Supply | AC 220 V ±10%, 50 Hz, <100 W |
| Operating Temperature | 10–40 °C |
| Wetted Materials | 316L Stainless Steel + PTFE (for syringe, slit, and fluidic path) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C-1 |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–70 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤ 400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Ambient Temp. | 10–30 °C |
| Ambient Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Dimensions | 220 × 210 × 360 mm |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GWF-8JDS |
| Pricing | Upon Request |
| Brand | TJtianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SMC 30F |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | GWF-6JA |
| Particle Detection Principle | Laser Light Obscuration (LO) |
| Measurement Channels | 20 µm, 15–25 µm, ≥25 µm, 25–50 µm, 51–100 µm, >100 µm |
| Sizing Range | 5–200 µm |
| Count Range | 0–65,535 particles per sample |
| Sample Volumes | 5 mL, 100 mL, 475 mL, 500 mL, or full-volume aspiration |
| Accuracy | ±10% of specified value |
| Relative Standard Deviation (RSD) | ≤2% (for standard latex particles ≥1500 particles/mL) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤45 W |
| Stirring Speed | 0–2000 rpm, paddle-type, non-contact |
| Operating Temperature | 10–40 °C |
| Dimensions | 325 × 320 × 460 mm |
| Weight | 22 kg |
| Compliance | Designed to meet Chinese Pharmacopoeia (ChP) General Chapter 0903, USP <788>, and ISO 8573-1 (particulate contamination in compressed gases—adapted for liquid-phase validation) |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30D |
| Measurement Principle | Freezing Point Depression |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 90 s |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg) |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Operating Environment | 10–30 °C, 5–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, <80 W |
| Compliance Support | Chinese Pharmacopoeia (ChP) injection database built-in |
| Data Interface | RS232 |
| Software Features | User permission management, audit-trail-capable data storage, configurable pass/fail criteria, multi-format print output |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | GWF-8JD |
| Pricing | Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | GWF-A1 |
| Pricing | Available Upon Request |
| Light Source | High-Stability Laser Diode with Optical Power Compensation Circuit |
| Sample Compatibility | Colorless & Colored Clear Liquids, Organic Solvents, Oil-Based Matrices, Weakly Acidic/Alkaline Solutions |
| Fluidic Path Materials | Imported 316L Stainless Steel & PTFE |
| Particle Size Range | 1–500 µm |
| Channel Resolution | >95% |
| Counting Accuracy | ±5% of Reference Value |
| Relative Standard Deviation (RSD) | <1.5% (for standard particles ≥1000 particles/mL) |
| Minimum Detectable Concentration | 18,000 particles/mL |
| Adjustable Sampling Volume | 0.2–1000 mL (0.1 mL resolution, accuracy <±0.5%) |
| Flow Rate Control | 5–80 mL/min (programmable) |
| Stirring Speed | 0–1000 rpm |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, <80 W |
| Data Interfaces | RS232, USB Storage, Thermal Printer Port |
| Software Platform | Embedded Android OS with Multi-Tier User Authentication & Audit Trail Support |
| Calibration Standards | USP <788>, USP <789>, ChP (Chinese Pharmacopoeia) Vol. IV, ISO 21510, EP 2.9.19 |
| Data Storage | Local SQLite Database with Statistical Analysis Engine |
| Compliance Features | Electronic Signature Support, User Access Logs, Data Integrity Controls per ALCOA+ Principles |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | YB-2A |
| Light Source | 20 W tri-phosphor fluorescent lamp with electronic ballast |
| Illuminance Range | 1000–6000 lx |
| Timing Range | 1–79 s (adjustable) |
| Power Consumption | 30 W |
| Digital Illuminance Meter | Integrated, direct-read, stable output |
| Visual Inspection System | Single-sided, operator-optimized optical path with anti-glare and flicker-free illumination |
| Compliance | Designed per Chinese Ministry of Health Standard WB1-362(B-121)-91 for clarity testing of injectables and large-volume parenterals |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GWF-9DW |
| Pricing | Available Upon Request |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30DS |
| Measurement Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Analysis Time | < 1.5 min |
| Pre-cooling Time | ≤ 3 min |
| Repeatability | RSD ≤ ±1% at 300 mOsmol/kg |
| Resolution | 1 mOsmol/kg |
| Linearity | < 1% deviation from linear fit |
| Brand | Tianhe |
|---|---|
| Origin | Tianjin, China |
| Model | SMC 30C |
| Measurement Principle | Freezing Point Depression |
| Range | 0–3000 mOsmol/kg H₂O |
| Sample Volume | 50–100 µL |
| Test Time | < 2 min |
| Pre-cooling Time | ≤ 3 min |
| Resolution | 1 mOsmol/kg |
| Repeatability | RSD ≤ ±1% (at 300 mOsmol/kg) |
| Accuracy | ±2 mOsmol/kg (≤400 mOsmol/kg), ±1% (>400 mOsmol/kg) |
| Linearity | < 1% deviation from linear fit |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 5–80% RH |
| Power Supply | AC 220 V ±10%, 80 W |
| Regulatory Status | Certified Medical Device per Chinese NMPA Class II requirements |
| Compliance | Meets pharmacopoeial specifications in Chinese Pharmacopoeia (2020 Edition), including for injectables, ophthalmic preparations, and osmotic diuretics |
Show next