Tianjin Tianhe Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelKKJ-100
Instrument TypeOptical Airborne Particle Counter
Channel Configuration8 configurable channels
Particle Size Range20–640 µm
Maximum Sample Concentration100,000 particles/L
Accuracy≤ ±20%
RepeatabilityRSD ≤ 5%
Sampling Flow Rate20–50 L/min (±5%)
Standard Flow Rate28.3 L/min (1.0 CFM)
Sampling Duration1–600 min
Zero Count Time≤ 10 min
Internal Data Storage3,000 measurement records
Display7-inch IPS touchscreen
InterfacesUSB, RS232
Power SupplyAC 220 V ±10%, 50 Hz, ≤120 W
Operating Environment0–35 °C, 10–90% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelGWF-D1
Instrument TypeOptical Particle Counter
Operating SystemAndroid-based embedded platform
Compliance StandardsChinese Pharmacopoeia (ChP) 2020 Edition, USP <788> & <789>, ISO 21510:2018, GB 8368–2018
Particle Detection PrincipleLight Blockage (Obscuration) with Dual-Beam Laser Compensation
Sample CompatibilityAqueous & non-aqueous solutions, oils, organic solvents, acidic/alkaline formulations
Material Contact Path316L stainless steel + PTFE fluidic pathway
Sample Volume Range0.2–1000 mL (±0.1 mL resolution)
Volumetric Accuracy< ±0.5%
Flow Rate5–80 mL/min
Particle Size Channels64 fixed channels + user-definable up to thousands
resolution0.1 µm
Size Range1–500 µm
Counting Range0–9,999,999 particles per sample
Counting Accuracy±5% of reference value
Channel Resolution>95%
RSD<1.5% (for ≥1000 particles/mL standard suspension)
Max Detectable Concentration18,000 particles/mL
Stirring Speed0–1000 rpm
Ambient Operating Temperature10–40 °C
Power Supply100–240 VAC, 50/60 Hz, <80 W
Data InterfacesRS232, USB host/device, thermal printer port
Data StorageOnboard SQLite database with statistical analysis engine
SecurityRole-based user authentication with audit trail logging
EnclosureSealed optical chamber with dust-proof sliding access door
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelGWF-9D
Instrument TypeOptical Particle Counter
PriceUpon Request
Key SpecificationsParticle Size Range: 1–500 µm
Counting Channels64 displayed (customizable up to thousands, resolution 0.01 µm)
Sample Volume0.2–6500 mL (±0.5% accuracy)
Flow Rate5–80 mL/min
Counting Accuracy±5% of specified value
Channel Resolution>95%
RSD<1.5% (for standard particles ≥1000 particles/mL)
Max Detection Concentration18,000 particles/mL
Sample Capacity1–20 vials
Stirring Speed0–1000 rpm (step-adjustable)
Operating Temperature10–40 °C
Power100–240 VAC, 50/60 Hz, <80 W
Data OutputDot-matrix printer, RS232, USB storage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGWF-R
Instrument TypeOptical Particle Counter
Operating SystemAndroid-based embedded platform
ComplianceUSP <788>, USP <789>, ChP 2025 (General Chapter 0903), ISO 21510, FDA 21 CFR Part 11
Calibration StandardsNIST-traceable latex particle suspensions
Sample CompatibilityAqueous & non-aqueous injectables, sterile powders, infusion devices, lipid emulsions
Detection PrincipleLight Blockage (Light Obscuration)
Particle Size Channels64 fixed + user-definable (down to 0.1 µm resolution)
Size Range1–500 µm (segmented sensor configuration)
Count Range0–9,999,999 particles per sample
Sample Volume0.2–1000 mL (±0.1 mL resolution)
Volume Accuracy< ±0.5%
Flow Rate5–80 mL/min
Counting Accuracy±5% of reference value
Channel Resolution>95% (per ISO 21501-4)
RSD<1.5% (for ≥1000 particles/mL standard suspension)
Max Detectable Concentration18,000 particles/mL
Stirring Speed0–1000 rpm
Ambient Operating Temperature10–40 °C
Power Supply100–240 VAC, 50/60 Hz, <80 W
Data InterfacesRS232, USB host/device, thermal printer port
StorageInternal database with timestamped audit trail, GLP-compliant metadata tagging
Software FeaturesBatch management, statistical reporting (mean, SD, CV, histogram, cumulative distribution), trend analysis, electronic signature support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
RegionDomestic (China)
ModelSKJ-A
Instrument TypeOptical Particle Counter
Particle Size Channels64 (0.001 µm resolution)
Size Ranges (Selectable)0.5–25 µm, 1–150 µm, 2–150 µm, 5–200 µm, or 10–500 µm
Count Range0–9,999,999 particles per sample
Sample Volume0.2–6500 mL (0.1 mL resolution)
Sampling Volume Error≤ ±3% at 5 mL
Flow Rate5–80 mL/min
Counting Accuracy≤ ±20% of reference value
Relative Standard Deviation (RSD)≤ 2% (for standard particles ≥1000 particles/mL)
Maximum Detectable Concentration18,000 particles/mL
Operating Temperature10–40 °C
Power SupplyAC 220 V, 50/60 Hz, ≤80 W
Material Compatibility316L stainless steel + PTFE wetted path
Data InterfaceRS232, USB
Compliance FeaturesAudit trail, user permission management, automated calibration & cleaning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelSKJ-1
Instrument TypeOptical Particle Counter
Particle Size Range0.1–2 µm / 0.2–5 µm / 0.5–25 µm
Number of Detection Channels8
Default Channel Sets (µm)[0.1, 0.15, 0.2, 0.25, 0.3, 0.5, 1.0, 2.0]
Sample Flow Rate10–80 mL/min
Test Duration (Online Mode)1–999 s
Sample Volume (Offline Mode)1–999 mL
Maximum Particle Concentration20,000 particles/mL
Maximum Operating Pressure (Online)0.7 MPa
Connection Thread1/4-28 UNF
Electrostatic Discharge Protection≥2 kV
Internal Data Storage Capacity10,000 measurement records
Power SupplyAC 80–305 V, ≤30 W
Display7-inch TFT LCD
Dimensions (L×W×H, excluding protrusions)285 × 280 × 293 mm
Weight6 kg
Operating Temperature10–50 °C
Operating Humidity10–90 % RH (non-condensing)
Interface OptionsUSB, RS-232, TCP/IP
ComplianceCE-marked design principles
compatible with ISO 111712016 reference calibration protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Instrument TypeOptical Particle Counter
ModelSKJ-FS/F
Operating SystemAndroid-based Embedded Platform
Detection PrincipleLight Obscuration (LO) / Single-Particle Optical Sizing (SPOS)
Particle Channel Resolution0.1 µm
Size Range Options1–150 µm, 2–150 µm, 5–200 µm, or 25–500 µm (sensor-dependent selection)
Counting Channels64 user-configurable bins
Counting Range0–9,999,999 particles per sample
Sample Volume0.2–1000 mL (0.1 mL resolution)
Volume Accuracy±3%
Flow Rate5–80 mL/min
Counting Accuracy±20% of reference value
Precision (RSD)≤2% (for standard latex particles ≥1000 particles/mL)
Maximum Detectable Concentration18,000 particles/mL
Stirring Speed0–1000 rpm (step-adjustable)
Operating Temperature10–40 °C
Power SupplyAC 220 V, 50/60 Hz, ≤80 W
Sample Path Materials316L stainless steel + PTFE
Data Integrity FeaturesAudit Trail, Role-Based Access Control (RBAC), Electronic Signature Support
ConnectivityRS232, USB host/device
StorageInternal database with statistical analysis engine
EnclosureDust-protected transparent access door
CalibrationFully automated on-board calibration routine
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelKKJ-01/03
Instrument TypeOptical Particle Counter
Measurement Range0.1–5 μm or 0.3–10 μm
Channel Count8
Maximum Sample Concentration100,000 particles/L
Counting Efficiency50±20% at 0.1 μm
Repeatability≤10%
Size Distribution Error≤±30% at 0.5 μm and 5 μm
Timing Accuracy≤1 s over 6 min
Particle Concentration Indication Error≤30% at 0.5 μm
Clean-up Time≤10 min (three consecutive zero counts with 95% confidence)
Sampling Flow Rate1.0 CFM (28.3 L/min)
Power SupplyAC 220 V ±10%, 50 Hz, ≤120 W
InterfacesEthernet, RS232
Internal Data Storage3,000 sample records
Dimensions305 × 315 × 385 mm
Operating Environment0–35 °C, 10–90% RH
Display7-inch IPS touchscreen
ComplianceJJF 1190–2008, ISO 21501-4 / GB/T 29024.4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSKJ-W
Instrument TypeOptical Particle Counter
Detection PrincipleLight Obscuration (LO) / Single-Particle Optical Sizing (SPOS)
Particle Size Range1–500 µm (selectable sub-ranges)
Channel Count256
Counting Accuracy±5% of certified reference value
Sample Volume Range0.2–6500 mL (0.1 mL resolution)
Sampling Flow Rate5–80 mL/min
Volume Error<±3%
Channel Resolution≥90%
RSD≤1.5% (for standard particles ≥1000 particles/mL)
Max Detectable Concentration18,000 particles/mL
Stirring Speed0–1000 rpm (magnetic, stepwise adjustable)
Operating Temperature10–40 °C
Relative Humidity5–80 %RH
Power SupplyAC 220 V ±10%, 50 Hz, ≤120 W
Data InterfacesRS232, USB storage, Wi-Fi, LAN
SoftwareWindows-based with 21 CFR Part 11-compliant audit trail, multi-level user accounts, customizable reporting, and embedded database
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelWCP-1
Instrument TypeOptical Particle Counter
Particle Detection PrincipleLight Obscuration (LO)
Counting Channels64 programmable channels
Adjustable Size Range10–100 µm (resolution down to 0.1 µm)
Sample Volume2–500 mL
Volume Accuracy±0.5% at 500 mL
Counting Accuracy±10%
Relative Standard Deviation (RSD)≤2% (for standard particle suspension ≥1000 particles/mL)
Maximum Detectable Concentration10,000 particles/mL
Power SupplyAC 220 V, 50 Hz, 110 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGWF-9D Series
PricingUpon Request
Instrument TypeOptical Particle Counter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelBM-A
Instrument TypeOptical Surface Particle Counter
Measurement Range0.1–5 µm, 0.3–10 µm, 5–150 µm, 20–500 µm
Number of Channels8
Channel Resolution0.1 µm
Sampling Area10 cm² (configurable)
Sampling Duration5–59 s (user-defined)
Accuracy≤ ±20%
Relative Standard Deviation (RSD)≤ 5%
Count Capacity0–9,999,999 particles
Reporting Unitscm², m², sq.in, sq.ft
Operating Temperature10–40 °C
Power SupplyAC 220 V ±10%, 50 Hz, ≤100 W
Sampling Flow Rate1.0 CFM (28.3 L/min)
InterfaceRS232, USB port for U-disk storage
Display & ControlColor capacitive touchscreen
Data OutputBuilt-in thermal printer, auto-storage, GLP-compliant audit trail (timestamped, user-ID logged)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGWF-RS
Instrument TypeOptical Particle Counter (Light Obscuration Method)
ComplianceChP 2025, USP <788> & <789>, ISO 21510
Operating SystemAndroid-based Embedded Platform
Power Supply100–240 VAC, 50/60 Hz, <80 W
Dimensions & WeightNot specified
CertificationsFDA 21 CFR Part 11 compliant architecture, audit trail enabled, multi-level user access control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelSKJ-D
Instrument TypeOptical Particle Counter
Particle Detection PrincipleLight Obscuration (LO)
Calibration Standards ComplianceISO 21501-4, USP <788>, ISO 4406, NAS 1638
Display10.1-inch Color TFT Touchscreen with Chinese/English UI
Sampling SystemHigh-Precision Syringe Pump
Material Compatibility316L Stainless Steel + PTFE Fluidic Path
ConnectivityRS232, USB 2.0, Wi-Fi 802.11b/g/n, Ethernet (RJ45)
Data ManagementAudit Trail Optional, 21 CFR Part 11 Ready, GLP/GMP-Compliant Reporting
Software FeaturesAutomatic Volume & Size Calibration, Multi-Channel Differential/Cumulative Counting, Customizable Channel Binning (64 Channels), Adjustable Stirring Speed (0–1000 rpm), Network-Enabled Lab Integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelLX-A
Instrument TypeOptical Particle Counter
Measurement Range5–150 µm
Number of Size Channels8
Channel Resolution0.1 µm
Sampling Area220 cm²
Adjustable Sampling Duration5–59 s
Accuracy≤ ±20%
Relative Standard Deviation (RSD)≤ 5%
Particle Count Capacity0–9,999,999 particles
Report Unitscm², m², sq.in, sq.ft
Operating Temperature10–40 °C
Power SupplyAC 220 V ±10%, 50 Hz, ≤100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
ModelBM-2A
Instrument TypeOptical Surface Particle Counter
Measurement Range0.1–5 µm, 0.3–10 µm, 5–150 µm, 20–500 µm
Number of Channels8
Channel Resolution0.1 µm
Sampling Area10 cm² (configurable)
Sampling Duration5–59 s (user-defined)
Accuracy≤ ±20%
Relative Standard Deviation (RSD)≤ 5%
Counting Capacity0–9,999,999 particles
Reporting Unitscm², m², sq.in, sq.ft
Operating Temperature10–40 °C
Power SupplyAC 220 V ±10%, 50 Hz, ≤100 W
Sampling Flow Rate1.0 CFM (28.3 L/min)
InterfaceRS232, USB port for U-disk storage
Display & ControlColor touchscreen with bilingual (English/Chinese) UI
Data OutputBuilt-in thermal printer, automatic local storage, PC connectivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelZKJ
Instrument TypeOptical Particle Counter
Particle Size Range0.1–5 µm and 0.3–10 µm
Number of Size Channels8 (user-configurable)
Sample Flow Rate1.0 CFM (28.3 L/min)
Vacuum Pump Power2.2 kW
Vacuum Pump Static Pressure220/210 mbar
Maximum Monitoring Points3200
Sampling Tube Length per Point≤60 m
Power Supply220 V / 380 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelGWF-DS1
Instrument TypeOptical Particle Counter
Laser Light SourceHigh-Stability Diode Laser with Energy Compensation Circuit
Sample CompatibilityColorless & Colored Clear Liquids, Organic Solvents, Oil-Based & Weakly Acidic/Alkaline Solutions
Fluidic Path MaterialsImported 316L Stainless Steel & PTFE
Sampling Volume Range0.2–1000 mL (±0.1 mL resolution)
Volume Accuracy< ±0.5%
Flow Rate5–80 mL/min
Particle Size Channels64 Fixed + User-Defined (up to thousands of bins)
Size Range1–500 µm
Minimum Resolution0.1 µm
Counting Accuracy±5% of Reference Value
Channel Resolution>95%
RSD<1.5% (for standard particles ≥1000 particles/mL)
Maximum Detectable Concentration18,000 particles/mL
Stirring Speed0–1000 rpm
Operating Temperature10–40 °C
Power Supply100–240 VAC, 50/60 Hz, <80 W
Data OutputThermal Printer, RS232, USB Storage
Software Compliance21 CFR Part 11 Audit Trail, Multi-Level User Access Control, GLP/GMP-Ready Electronic Record Management
Operating SystemAndroid-based Embedded UI
DatabaseLocal SQL Database with Statistical Analysis Engine
Environmental ProtectionSealed Dust-Proof Viewing Door
CalibrationFully Automated Onboard Calibration with NIST-Traceable Standard Particles per USP <788>, USP <789>, ChP 2025, ISO 21510, and GB 8368–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Instrument TypeOptical Surface Particle Counter
Measurement PrincipleLaser Light Scattering & Obscuration
Detection Range5–150 µm
Number of Size Channels8
Channel Resolution0.1 µm
Sampling Area10 cm²
Adjustable Sampling Duration5–59 s
Accuracy±20 %
Repeatability (RSD)<5 %
Particle Count Capacity0–9,999,999
Display Unitscm², m², sq.in, sq.ft
Operating Temperature10–40 °C
Power SupplyAC 220 V ±10 %, 50 Hz, ≤100 W
InterfaceRS232, USB (U-disk storage)
Data SecurityRole-based User Management System
CalibrationInternal Reference Curve with Auto-Fit Algorithm
Compliance SupportASTM F3212 (Standard Guide for Evaluating Particulate Contamination on Medical Device Packaging), ISO 11140 (Sterilization – Qualification of Process Indicators), GB/T 24334–2009 (Determination of Dust Specks on Paper and Paperboard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTianhe
OriginTianjin, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelSKJ-Q1
Instrument TypeOptical Particle Counter
Particle Size Range0.1–1 µm and 0.2–3 µm
Number of Channels8 (user-configurable)
Sample Flow Rate10–100 mL/min
Sample Temperature Range0–80 °C
Minimum Test Volume≥2 mL
Online Test Duration1–9999 s
Offline Test Volume0.2–6550 mL
Maximum Particle Concentration20,000 particles/mL
Maximum Operating Pressure0.5 MPa
Connector Options1/4-28 UNF, 1/4" PFA Flare
Internal Memory Capacity32,000 measurement records
Display10.1-inch touchscreen
Dimensions (L×W×H, excluding protrusions)276 × 337 × 460 mm
Weight12 kg
Power SupplyAC 220 V, ≤50 W
Electrostatic Discharge Protection≥2 kV
Operating Temperature10–50 °C
Operating Humidity10–90% RH (non-condensing)
Interface OptionsUSB, TCP/IP, RS-232
Compliance FeaturesDual-language UI (English/Chinese), user account permission management, real-time data logging with timestamped audit trail, alarm triggers for fluid leakage, system fault, and out-of-spec particle counts
Show next