Transmission Electron Microscope
Filter
Showing 31–40 of 40 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher global quality system) |
| Model | Talos F200S G2 |
| Price | Upon Request |
| Acceleration Voltage | 200 kV |
| HRTEM Line Resolution | 0.10 nm |
| Minimum Detectable Feature Size | 0.16 nm |
| Field Emission Gun (FEG) Total Beam Current | >150 µA |
| EDS System | Dual in-column SDD Super-X detectors, windowless design with shutter protection |
| EDS Energy Resolution | ≤136 eV at Mn-Kα (10 kcps output) |
| EDS Mapping Pixel Dwell Time | Down to 10 µs |
| EDS Solid Angle | 0.45 sr |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Talos F200X S/TEM |
| Accelerating Voltage | 200 kV (standard configuration) |
| Resolution | <0.12 nm TEM point resolution, <0.16 nm STEM HAADF resolution |
| EDS System | Super-X with four integrated silicon drift detectors (SDDs) |
| Camera | Ceta 16M CMOS, 25 fps at 512 × 512 |
| Stage | Piezo-driven high-precision stage with sub-nanometer stability |
| Software | Thermo Scientific Velox S/TEM Platform (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Czech Republic |
| Model | Talos L120C TEM |
| Accelerating Voltage | 120 kV |
| Point Resolution | < 0.37 nm |
| Line Resolution | 0.204 nm |
| Magnification Range (TEM) | 25× – 650,000× |
| Magnification Range (STEM) | 200× – 2.2 M× |
| Alpha Tilt Range (Standard Holder) | −90° to +90° |
| STEM HAADF Resolution | ≤ 1.0 nm |
| Detector | 4k × 4k Ceta CMOS Camera |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | Krios 5 |
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-sourced system) |
| Pricing | Available upon consultation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Krios G4 Cryo-TEM |
| Price Range | USD 5.2–5.8 million (estimated FOB) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tundra |
| Accelerating Voltage | Fixed 100 kV |
| Maximum Magnification | 650,000× |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Netherlands |
| Model | Tundra |
| Acceleration Voltage | 200 kV (standard configuration) |
| Magnification Range | ×50 to ×1,000,000 |
| Specimen Stage | Single-tilt cryo-transfer holder with automated loading |
| Minimum Information Limit | ≤3.5 Å under optimal conditions (SPA workflow) |
| Footprint | 3.2 m × 2.8 m (including shielding and service clearance) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific™ Glacios™ |
| Price Range | USD $2.5M–$3.8M (FOB) |
| Accelerating Voltage | 80–200 kV |
| Magnification | Up to 10,000,000× |
| Electron Source | 200 kV X-FEG (Cold Field Emission Gun) |
| Automation | Integrated Autoloader with cryo-transfer compatibility |
| Software Platform | EPU v3.x for Single-Particle Analysis (SPA) |
| Detector Compatibility | Supports Direct Electron Detectors (e.g., Falcon 4, Gatan K3) and Volta Phase Plate (VPP) |
| Footprint | < 8 m² (including service access) |
| Brand | Vialux |
|---|---|
| Origin | Germany |
| Interface | PCIe x4 Gen3 |
| Wavelength Range | 400–700 nm |
| Micromirror Array | 1024 × 768 |
| Micromirror Pitch | 13.7 µm |
| Active Area | 14.0 × 10.5 mm² |
| Onboard DDR4 Memory | 16 GB (up to 32 GB optional) |
| Max. 1-bit Frame Rate (PCIe) | ~23,000 fps |
| Max. Switching Rate (1-bit B/W) | 22,727 Hz |
| Control Software | ALP-5.0 |
| Camera Synchronization Support | ViALUX Direct Link Sensor (DLS) API |
| Compliance | Compatible with GLP/GMP-aligned lab workflows, supports audit-trail-capable software integration via ALP-5.0 logging framework |