Empowering Scientific Discovery

TSI Group Inc. China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7301-P
Instrument TypeOnline Particle Counter
Flow Rate2.83 L/min (0.1 CFM)
Particle Size Range0.3–50 µm
Selectable Size Channels0.3, 0.5, 1.0, 2.0, 2.5, and 5.0 µm (user-selectable triple-channel configuration)
ComplianceISO 21501-4
Data OutputTCP/IP Ethernet + RS-485 Modbus® RTU
Onboard Storage3,000 sample records
MountingCeiling-mountable, UL 2043 listed
PowerInternal vacuum pump with integrated exhaust filtration
Operating EnvironmentLow-noise design for cleanrooms, pharmacies, isolation rooms, and office spaces
Warranty2 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7110
Instrument TypeOnline
Flow Rate28.3 L/min (1 CFM)
Particle Size Range0.100–5.0 µm
Minimum Detectable Size0.100 µm (100 nm)
Channel CountUp to 8 simultaneous size channels
ComplianceISO 21501-4
Data Storage Capacity2,000 sample records
Communication InterfacesEthernet (Modbus TCP), RS-485 (Modbus RTU), Pulse Output
Enclosure MaterialStainless Steel
Vacuum RequirementExternal source required
Calibration TraceabilityNIST-traceable PSL standards via TSI’s certified aerosol generation and CPC verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
ModelM32-01
ApplicationLaboratory Environmental Monitoring
Sampling Ports32
Compatible Flow Rate28.3 L/min (1 CFM)
Minimum Detectable Particle Size100 nm
Software ControlFMS 5
Maximum Tubing Length per Port38.1 m
Self-Cleaning CycleEnabled
Vacuum Flow MonitoringIntegrated Pressure Sensors
Warranty2 Years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model9303 / 9306
Instrument TypeHandheld Particle Counter
Flow Rate2.83 L/min (0.1 CFM)
Flow Accuracy≤ ±5%
Particle Size Ranges9303: 0.3–10 µm
93060.3–20 µm
Simultaneous Channels3 (9303), 6 (9306)
Data Storage Capacity1,500 samples (9303)
Display3.6-inch monochrome LCD (9303)
ComplianceISO 21501-4, ISO 14644-1, Fed Std 209E, EC GMP Annex 1
InterfaceUSB 2.0
PowerRechargeable Li-ion battery
Weight0.58 kg (9303), 1.0 kg (9306)
HousingHigh-impact molded polymer enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model Variants7510, 7501, 7201, 7301, 7301-P
Instrument TypeOnline Particle Counter
Flow RateHigh-Flow (28.3 L/min for 7510
Particle Size Ranges0.2–2 µm (7201), 0.3–5 µm (7301), 0.3–25 µm (7510), 0.5–10 µm (7501)
Communication ProtocolsEthernet (TCP/IP), Modbus® RTU Serial
Power OptionsPoE (IEEE 802.3af) or External DC Supply
Data Storage CapacityUp to 3,000 Sample Records
ComplianceISO 21501-4, RoHS
Housing MaterialStainless Steel
Optional SensorsIntegrated Temperature & Relative Humidity Probe
Alarm OutputConfigurable Digital Relay Output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelTSI AeroTrak®+ Portable Particle Counter A100 Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model9306
Instrument TypeHandheld
Flow Rate2.83 L/min (0.1 CFM)
Particle Size Range0.3–25 µm
Channel ConfigurationSimultaneous 6-channel detection
Data Storage Capacity>10,000 samples
ComplianceISO 21501-4, ISO 14644-1, EU GMP Annex 1, FS209E
InterfaceColor touchscreen (9.1 cm), USB, Ethernet
PowerRemovable rechargeable Li-ion battery
Optional AccessoriesIntegrated temperature & humidity sensor, external thermal printer
Software CompatibilityTrakPro™ Lite, FMS 5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
ModelFMS
Instrument TypeOnline Continuous Monitoring System
Flow CapabilityHigh-Flow Sampling Support
Regulatory ComplianceFDA 21 CFR Part 11, EU GMP Annex 1, ISO 14644, GAMP® 5
DatabaseRedundant SQL-based (Microsoft SQL Server / MySQL compatible)
Communication ProtocolsModbus RTU/ASCII, 4–20 mA, Digital I/O, PoE, Ethernet
Output ControlVacuum pump trigger, fixed-point air sampler activation
Data ExportCSV, PDF, scheduled/real-time reports
SecurityRole-based access, password aging, full audit trail, electronic signatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model9110
Instrument TypeHandheld
Flow Rate28.3 L/min (1 CFM)
Particle Size Range0.100–5.0 µm
Channel Count8 simultaneous size channels
Detection PrincipleHeNe laser light scattering
ComplianceISO 21501-4, ISO 14644-1 Class 1 & 2 cleanroom verification
Data Storage10,000 samples across 999 locations
InterfaceEthernet, USB, pulse output
AlarmVisual and audible industrial-grade alert
Sampling CompatibilityCompatible with TSI M32-01 Manifold for multi-point sampling
Calibration TraceabilityNIST-traceable PSL standards via TSI CPC and aerodynamic classifier
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model6301-24100
Instrument TypeLaboratory
Flow RateLow-flow configuration
Flow Accuracy±0% (calibrated per ISO 21501-4)
Timing Accuracy±0% (internal high-stability quartz oscillator)
Repeatability±0% (defined per ISO 21501-4 test protocol)
Size Distribution AccuracyCompliant with ISO 21501-4 Annex B
Indication ErrorWithin certified calibration uncertainty limits
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7510-22050
Instrument TypeLaboratory
Flow RateLow-flow configuration
Flow Accuracy±0% (per ISO 21501-4 compliant calibration)
Timing Accuracy±0% (internal high-stability quartz oscillator)
Repeatability±0% (as validated per ISO 21501-4 Annex B)
Size Distribution AccuracyCompliant with ISO 21501-4 Class 1 requirements
Indication ErrorWithin certified calibration uncertainty limits
Channel Configuration6-channel, upper size threshold: 25 µm
Data Storage Capacity250,000 sample records
Laser Warranty5-year limited warranty on laser diode assembly
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model Numbers7201, 7301, 7501
Instrument TypeOnline Particle Counter
Flow Rate2.83 L/min (0.1 ft³/min)
Particle Size Ranges7201: 0.2–10 µm
73010.3–25 µm
75010.5–25 µm
Channel CapacityUp to 4 simultaneous size channels
Data Storage3,000 samples
Communication ProtocolsTCP/IP (Ethernet), Modbus® RTU (RS-485)
Power OptionsPoE (IEEE 802.3af) or external 12–24 VDC
ComplianceISO 21501-4, RoHS, Low-Outgassing Construction
Enclosure MaterialStainless Steel
CalibrationDigital, NIST-traceable
Optional AccessoriesIntegrated Temperature/Humidity Sensor, External Alarm Relay Output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7510-01F-VHP / 7510-02F-VHP / 7510-A2F-VHP
TypeOnline Particle Counter
Flow Rate1 CFM (28.3 L/min)
ComplianceISO 21501-4
Particle Channels4 simultaneous size channels
Data Storage Capacity3,000 sample records
CommunicationEthernet (TCP/IP), Modbus RTU serial, 4–20 mA analog output
Power OptionsPoE (IEEE 802.3af) or local 24 VDC
Enclosure MaterialStainless steel (optional)
CertificationsRoHS compliant
Optional SensorsIntegrated temperature & relative humidity probe
Alarm InterfaceDry-contact external alarm output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
ModelTSI CPC 9001
Flow Rate0.1 CFM (2.83 L/min)
Detection Lower Limit10 nm
False Count Rate< 0.07 count/ft³
Sample Storage Capacity10,000 samples across 250 zones and 999 locations
Operating FluidUltra-pure or deionized water
Housing Material316L stainless steel
ConnectivityUSB, Ethernet, USB mass storage
Software CompatibilityTrakPro™ Lite Secure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model9510-BD
Flow Rate28.3 L/min (1.0 CFM)
Flow Accuracy±5%
Particle Size Range0.5–25 µm
Detection Channels6 simultaneous size bins (0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm)
Viability DetectionDual-channel laser-induced fluorescence (LIF) at 405 nm excitation with 2 fluorescence emission bands + 1 optical particle counting channel
Calibration ComplianceISO 21501-4, JIS B9921, NIST-traceable
Housing MaterialStainless steel
Operating Temperature5–35°C (41–95°F), 20–95% RH non-condensing
Storage Temperature0–50°C (32–122°F), ≤98% RH non-condensing
Data Storage10,000 samples across up to 999 locations
InterfaceVGA 5.7″ capacitive touchscreen, Ethernet & USB 2.0, Modbus TCP
SoftwareTrakPro Lite Secure (included), optional FMS integration
Standards ReportingISO 14644-1, EU GMP Annex 1, FS209E
Power110–240 VAC universal
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0