- All
- Favorite
- Popular
- Most rated
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8715 |
| Category | Differential Pressure & Multi-Parameter Air Flow Analyzer |
| Resolution | 0.001 Pa (differential pressure) |
| Measurement Range | ±1000 Pa (differential pressure), 0–50 m/s (air velocity, with optional thermal anemometer probes) |
| Accuracy | ±0.5% of reading ±0.005 Pa (DP), ±2% of reading (velocity, typical with calibrated probe) |
| Operating Temperature | 0–50 °C |
| Operating Relative Humidity | 0–95% RH (non-condensing) |
| Interface | USB 2.0 |
| Compliance | Meets requirements referenced in GB/T 50243–2016, GB 50591–2010, WS 394–2012, AQ/T 4271–2015, CJJ/T 309–2013, GB/T 36066–2018 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9535 / 9535-A / 9545 / 9545-A |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | 0–30 m/s |
| Accuracy | ±3% of reading (for 0.15–30 m/s at 25°C) |
| Operating Temperature | –18°C to +93°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Temperature Compensation | ±0.03°C/°C deviation from 25°C |
| RH Compensation | ±0.2% RH/°C (including 1% hysteresis) |
| Data Storage | 12,700 samples + 100 test IDs |
| Included Software | LogDat2™ data download and analysis software |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | 8455, 8465, 8475 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8371 |
| Price Range | USD 2,600–6,500 (est.) |
| Instrument Type | Air Flow Capture Hood |
| Flow Range | 5–1000 L/s (18–3600 m³/h) |
| Operating Temperature | 0–60 °C |
| Operating Humidity | 0–95 % RH (non-condensing) |
| Resolution | 0.1 L/s |
| Accuracy | ±3 % of reading or ±0.5 L/s (whichever is greater) |
| Weight | 3.4 kg (for 610 × 610 mm hood) |
| Power Supply | 4 × C-cell alkaline batteries (40 h continuous operation) |
| Display | Backlit LCD with real-time flow readout |
| Optional Accessories | Portable thermal printer, calibration certificate traceable to NIST |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5815 / 5825 |
| Price Range | USD 2,600 – 6,500 |
| Pressure Range | −15 to +15 in. H₂O (−3735 to +3735 Pa) |
| Accuracy | ±0.005 in. H₂O (±1% of reading ±1 Pa) |
| Resolution | 0.001 in. H₂O (1 Pa) |
| Velocity Range (Pitot Tube) | 250–15,500 ft/min (0.27–78.7 m/s) |
| Velocity Accuracy | ±1.5% at 2000 ft/min (10.16 m/s) |
| Resolution | 1 ft/min (0.1 m/s) |
| Duct Size Input (5825 only) | 1–250 in. (0.1-in. increments) |
| Data Storage | 12,700 readings + 100 data sets |
| Sampling Interval | 1 s – 1 h |
| Operating Temperature | 0–70 °C |
| Storage Temperature | −40–85 °C |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight | 0.27 kg (with batteries) |
| Power | 4 × AA alkaline or optional AC adapter |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9565 Series |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5725 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.25–30 m/s (50–6000 ft/min) |
| Accuracy (Velocity) | ±1.0% of reading or ±0.02 m/s (±4 ft/min), whichever is greater |
| Temperature Range | 0–60 °C (32–140 °F) |
| Temperature Accuracy | ±0.5 °C (±2 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Duct Area Range | 0–16 m² (0–173.6 ft²) |
| Volume Flow Calculation | Enabled via user-input duct geometry/area |
| Operating Temp (Instrument) | 5–45 °C |
| Operating Temp (Probe) | 0–60 °C |
| Storage Temp | −20–60 °C |
| Data Memory | 12,700 readings + 100 data sets |
| Sampling Interval | 1 s – 1 h |
| User-Defined Time Constant | Yes |
| Display | Real-time velocity, temperature, min/max, and rolling average |
| Probe | 100 mm (4 in.) bidirectional vane |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with battery) | 270 g |
| Power | One 9V alkaline or NiCd battery |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9515 |
| Price | Upon Request |
| Air Velocity Range | 0–4000 ft/min (0–20 m/s) |
| Accuracy | ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater |
| Resolution | 1 ft/min (0.01 m/s) |
| Temperature Range | –18 to 93 °C (0 to 200 °F) |
| Temperature Accuracy | ±0.3 °C (±0.5 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Operating Temperature (Instrument) | 5–45 °C (40–113 °F) |
| Operating Temperature (Sensor, 9515) | –18–93 °C (0–200 °F) |
| Storage Temperature | –20–60 °C (–4–140 °F) |
| Dimensions (9515) | 8.4 × 17.8 × 4.4 cm (3.3 × 7.0 × 1.8 in) |
| Probe Length (9515) | 101.6 cm (40 in) |
| Probe Tip Diameter (9515) | 7.0 mm (0.28 in) |
| Probe Base Diameter (9515) | 13.0 mm (0.51 in) |
| Weight (with batteries) | 0.27 kg (0.6 lb) |
| Power Supply | 4 × AA batteries |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9535 |
| Pricing | Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8380 |
| Hood Size | 2 ft × 2 ft (610 mm × 610 mm) |
| Pressure Measurement Range | ±250 Pa |
| Accuracy | ±3% of reading (typical for air flow measurement per ISO 16813 and ASHRAE Guideline 1) |
| Weight | <2.7 kg (6 lbs) |
| Battery | Rechargeable NiMH AA × 4 |
| Data Interface | USB + Bluetooth |
| Compliance | NIST-traceable calibration certificate included |
| Operating Temperature | 10–40 °C |
| Relative Humidity Limit | ≤90% RH non-condensing |