Empowering Scientific Discovery

TSI Group Inc. China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model8715
CategoryDifferential Pressure & Multi-Parameter Air Flow Analyzer
Resolution0.001 Pa (differential pressure)
Measurement Range±1000 Pa (differential pressure), 0–50 m/s (air velocity, with optional thermal anemometer probes)
Accuracy±0.5% of reading ±0.005 Pa (DP), ±2% of reading (velocity, typical with calibrated probe)
Operating Temperature0–50 °C
Operating Relative Humidity0–95% RH (non-condensing)
InterfaceUSB 2.0
ComplianceMeets requirements referenced in GB/T 50243–2016, GB 50591–2010, WS 394–2012, AQ/T 4271–2015, CJJ/T 309–2013, GB/T 36066–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model9535 / 9535-A / 9545 / 9545-A
Instrument TypeHot-Wire Anemometer
Resolution0.01 m/s
Velocity Range0–30 m/s
Accuracy±3% of reading (for 0.15–30 m/s at 25°C)
Operating Temperature–18°C to +93°C
Operating Humidity0–95% RH (non-condensing)
Temperature Compensation±0.03°C/°C deviation from 25°C
RH Compensation±0.2% RH/°C (including 1% hysteresis)
Data Storage12,700 samples + 100 test IDs
Included SoftwareLogDat2™ data download and analysis software
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model Numbers8455, 8465, 8475
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model8371
Price RangeUSD 2,600–6,500 (est.)
Instrument TypeAir Flow Capture Hood
Flow Range5–1000 L/s (18–3600 m³/h)
Operating Temperature0–60 °C
Operating Humidity0–95 % RH (non-condensing)
Resolution0.1 L/s
Accuracy±3 % of reading or ±0.5 L/s (whichever is greater)
Weight3.4 kg (for 610 × 610 mm hood)
Power Supply4 × C-cell alkaline batteries (40 h continuous operation)
DisplayBacklit LCD with real-time flow readout
Optional AccessoriesPortable thermal printer, calibration certificate traceable to NIST
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model5815 / 5825
Price RangeUSD 2,600 – 6,500
Pressure Range−15 to +15 in. H₂O (−3735 to +3735 Pa)
Accuracy±0.005 in. H₂O (±1% of reading ±1 Pa)
Resolution0.001 in. H₂O (1 Pa)
Velocity Range (Pitot Tube)250–15,500 ft/min (0.27–78.7 m/s)
Velocity Accuracy±1.5% at 2000 ft/min (10.16 m/s)
Resolution1 ft/min (0.1 m/s)
Duct Size Input (5825 only)1–250 in. (0.1-in. increments)
Data Storage12,700 readings + 100 data sets
Sampling Interval1 s – 1 h
Operating Temperature0–70 °C
Storage Temperature−40–85 °C
Dimensions8.4 × 17.8 × 4.4 cm
Weight0.27 kg (with batteries)
Power4 × AA alkaline or optional AC adapter
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model5725
Instrument TypeVane Anemometer
Velocity Range0.25–30 m/s (50–6000 ft/min)
Accuracy (Velocity)±1.0% of reading or ±0.02 m/s (±4 ft/min), whichever is greater
Temperature Range0–60 °C (32–140 °F)
Temperature Accuracy±0.5 °C (±2 °F)
Temperature Resolution0.1 °C (0.1 °F)
Duct Area Range0–16 m² (0–173.6 ft²)
Volume Flow CalculationEnabled via user-input duct geometry/area
Operating Temp (Instrument)5–45 °C
Operating Temp (Probe)0–60 °C
Storage Temp−20–60 °C
Data Memory12,700 readings + 100 data sets
Sampling Interval1 s – 1 h
User-Defined Time ConstantYes
DisplayReal-time velocity, temperature, min/max, and rolling average
Probe100 mm (4 in.) bidirectional vane
Dimensions8.4 × 17.8 × 4.4 cm
Weight (with battery)270 g
PowerOne 9V alkaline or NiCd battery
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model9515
PriceUpon Request
Air Velocity Range0–4000 ft/min (0–20 m/s)
Accuracy±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater
Resolution1 ft/min (0.01 m/s)
Temperature Range–18 to 93 °C (0 to 200 °F)
Temperature Accuracy±0.3 °C (±0.5 °F)
Temperature Resolution0.1 °C (0.1 °F)
Operating Temperature (Instrument)5–45 °C (40–113 °F)
Operating Temperature (Sensor, 9515)–18–93 °C (0–200 °F)
Storage Temperature–20–60 °C (–4–140 °F)
Dimensions (9515)8.4 × 17.8 × 4.4 cm (3.3 × 7.0 × 1.8 in)
Probe Length (9515)101.6 cm (40 in)
Probe Tip Diameter (9515)7.0 mm (0.28 in)
Probe Base Diameter (9515)13.0 mm (0.51 in)
Weight (with batteries)0.27 kg (0.6 lb)
Power Supply4 × AA batteries
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model9535
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model8380
Hood Size2 ft × 2 ft (610 mm × 610 mm)
Pressure Measurement Range±250 Pa
Accuracy±3% of reading (typical for air flow measurement per ISO 16813 and ASHRAE Guideline 1)
Weight<2.7 kg (6 lbs)
BatteryRechargeable NiMH AA × 4
Data InterfaceUSB + Bluetooth
ComplianceNIST-traceable calibration certificate included
Operating Temperature10–40 °C
Relative Humidity Limit≤90% RH non-condensing
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0