| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3787 / 3788 |
| Instrument Type | Aerosol Detector |
| Minimum Detectable Particle Size (D₅₀) | 5 nm |
| Maximum Counting Concentration | 250,000 cm⁻³ |
| Aerosol Flow Rate | 0.6 ± 0.06 L/min |
| High-Flow Mode | 1.5 ± 0.15 L/min |
| Response Time (10–90%) | < 300 ms |
| Time Constant | ~130 ms |
| Background Count | < 0.01 cm⁻³ (hourly average) |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Working Fluid | Deionized or Ultrapure Water |
| Water Reservoir | External 1 L (3-day operation) or optional 4 L (12-day operation) |
| Water Consumption | ~300 mL/day |
| Vacuum Source | Integrated diaphragm pump |
| Compliance | Manufactured per ISO 9001 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 379020A / 379030 |
| Instrument Type | Aerosol Conditioning Diluter |
| Dilution Ratio (379020A) | 15:1 to 3000:1 (8-hole disk), 15:1 to 300:1 (10-hole disk) |
| Dilution Ratio (379021) | 12:1 to 2400:1 (8-hole disk), 12:1 to 240:1 (10-hole disk) |
| Sample Inlet Flow | ~1.0 L/min (379020A), ~1.2 L/min (379021) |
| Dilution Air Temperature Settings | Off, 40 °C, 80 °C, 120 °C, 150 °C (379020A) |
| Heating Temperature (379030/379031) | Up to 400 °C |
| Outlet Flow Range | 0.5–1.5 L/min (standard), up to 5 L/min (high-flow mode) |
| Pressure Drop Range | −100 to +150 mbar (379020A), −50 to +150 mbar (379021) |
| Secondary Dilution Flow (379030) | 0–15 L/min |
| Design Configuration | Separated sampling outlet and controller (379020A), Integrated outlet and controller (379021) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8150 |
| Instrument Type | Aerosol Filter Tester |
| Compliance Standards | 42 CFR Part 84, EN 143, EN 149, ISO 16900-3, ISO 23328-1, ASTM F3502-2021, GB 2626 |
| Measurement Principle | Dual-channel photometric aerosol challenge & filtration efficiency quantification |
| Optical Detection | Simultaneous upstream/downstream photometry |
| Control Interface | PLC-driven with embedded diagnostics |
| Form Factor | Modular benchtop unit with stackable base and detachable photometer housing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3070A |
| Pricing | Available Upon Request |
| Particle Size Range | 10 nm – 1 µm |
| Maximum Data Acquisition Rate | 3.75 readings/sec |
| Length Concentration Resolution | 0.01 mm/cm³ |
| Operating Temperature | 10–35 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IN-3563 |
| Pricing | Available Upon Request |
| Instrument Type | Aerosol Nephelometer |
| Detection Limit | 1×10⁻⁷ m⁻¹ to 1×10⁻² m⁻¹ |
| Scattering Angle Range | 7°–170° (with backward scattering defined as 90°–170°) |
| Response Time | <10 s |
| Sample Flow Rate | 20–200 L/min |
| Wavelengths | 450 nm, 550 nm, and 700 nm |
| Integrated Sensors | Temperature, Relative Humidity, Pressure |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3480 |
| Pricing | Upon Request |
| Particle Size Range | 2–100 nm |
| Particle Generation Rate | >10⁸ #/cm³ |
| Liquid Conductivity | 0.2 S/m |
| Liquid Flow Rate | 50–100 nL/min |
| Sheath Air Flow Rate | 0.2–0.5 L/min |
| CO₂ Flow Rate | 0.05–0.5 L/min |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3433 |
| Pricing | Available Upon Request |
| Particle Size Range | 0.5–50 µm |
| Output Aerosol Concentration | 0.3–4 mg/m³ (standard motor) / 3–40 mg/m³ (optional motor) |
| Powder Feed Rate | 3–90 mg/hr |
| Compressed Air Requirement | 12–21 L/min at 138 kPa |
| Turntable Rotation Speed | 0.25–3.3 rev/hr (standard motor) / 2.5–33.3 rev/hr (optional motor) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3089 |
| Pricing | Available Upon Request |
| Operating Principle | Electrostatic Deposition |
| Particle Type | Solid or Non-Volatile Liquid Aerosols |
| Size Range | 2–100 nm |
| Flow Rate | 0.2–2.5 L/min |
| Ambient Temperature | 10–50 °C |
| Relative Humidity | 0–90 % RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3160 |
| Price Range | USD 65,000–130,000 |
| Instrument Type | Aerosol Filter Tester |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3080 |
| Pricing | Available Upon Request |
| Particle Type | Solid or Non-Volatile Liquid |
| Size Range (3080L) | 10–1000 nm |
| Size Range (3080N) | 2–150 nm |
| Max Concentration | 1 × 10⁸ #/cm³ |
| Aerosol Flow Rate | 0.2–3 L/min (model-dependent) |
| Sheath Gas Flow Rate | 2–20 L/min (model-dependent) |
| Operating Temperature | 7–43 °C |
| Operating Pressure | 1 ± 0.2 atm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8587A |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | 3012, 3012A, 3054, 3054A, 3077, 3077A |
| Pricing | Available Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 3076 |
| Aerosol Generation Principle | Collison-type nebulization |
| Nominal Aerosol Flow Rate | 3.0 L/min |
| Maximum Aerosol Concentration | ≥1 × 10⁷ particles/cm³ |
| Particle Size Range | 0.01–2 µm (multimodal, adjustable via solution formulation and operational parameters) |
| Aerosol Precursors | PSL, DOP, silicone oil, NaCl, sucrose, and other soluble or colloidal suspensions |
| Construction | All-stainless-steel nozzle assembly, borosilicate glass reservoir, integrated low-noise diaphragm compressor |
| Compliance | Designed for ISO 14644-3, ISO 21501-4, ASTM F2894, and EN 1822 test protocols |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533EP |
| Instrument Type | Real-Time Aerosol Mass Concentration and Size-Fractionated Monitor |
| Aerosol Concentration Range | 0.001–150 mg/m³ |
| Power Supply | Rechargeable 6600 mAh Lithium Battery + AC Adapter |
| Data Logging | Internal Memory with Programmable Interval (1 sec–1 hr) |
| Output Interfaces | Analog (0–5 V, 4–20 mA), USB, Alarm Relay |
| Compliance | NIOSH 0600 (PM1, PM2.5, PM10), ISO 7708, ASTM D6245, US EPA EQOA-PM Reference Method Equivalent (for screening) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8130A |
| Instrument Type | Aerosol Filter Efficiency Tester |
| Test Aerosols | NaCl (salt) and DEHS/DOP (oil-based) |
| Maximum Efficiency Measurement | 99.9999% |
| Compliance | 42 CFR Part 84, EN 143, ISO 16900-3, ISO 23328-1, GB 2626, JMOL Standards |
| Automation Level | Fully Automated with Self-Diagnostic Routines |
| Optical Detection | Integrated, Serviceable Photometer |
| User Interface | Touchscreen GUI with Audit-Trail-Capable Data Logging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3776-CPC |
| Pricing | Available Upon Request |
| Particle Size Range | 3 nm – 5 µm |
| Maximum Concentration | 1 × 10⁵ #/cm³ |
| Response Time | ≤1 s |
| Background Noise | <0.01 #/cm³ |
| Signal-to-Noise Ratio | 25:1 |
| Operating Temperature | 10–37 °C |
| Relative Humidity | 0–90 % RH (non-condensing) |