Ultra Pure Water System
Filter
Showing 271–300 of 372 results
| Brand | RSJ |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Spring-S / Spring-R |
| Pure Water Grade | Type I (ASTM D1193-20) |
| Resistivity | ≥18.2 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <15 ppb (UV-equipped models: <5 ppb) |
| Feed Water | Municipal tap water (5–40°C, pressure ≥0.1 MPa) |
| RO Configuration | Single-stage (S-series) or Dual-stage (R-series) |
| RO Recovery Rate | 30–60% (S), 20–30% (R) |
| Ion Removal Efficiency | 96–98% |
| Microbial & Particulate Removal (>0.22 µm) | >99% |
| Conductivity | <5 µS/cm |
| Max Flow Rate | ≥1.8 L/min |
| Quantitative Dispensing Range | 0.1–25 L (±2% accuracy) |
| Dimensions (W×H×D) | 423 × 445 × 280 mm |
| Power Supply | 220 V AC, 50–100 W |
| Certifications | NSF/ANSI Standard 58 & 61 compliant materials (NSF-certified wetted components) |
| Brand | RSJ |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | UNIQ |
| Quotation | Upon Request |
| Purified Water Grade | Type I (ASTM D1193-06 Grade I / GB/T 6682-2008 Grade I) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.2 µm) | <1 particle/mL |
| Integrated TOC Monitor Range | 1.0–999 ppb |
| Dual-Grade Dual-Quantitative Dispensing | Up to 2 L/min, ±1% volumetric accuracy |
| Storage Capacity | 25 L (modular expansion available) |
| Feed Water | Municipal tap water, 5–40 °C, 1–6 bar pressure |
| Disinfection | RO/UP circuit UV-LED + chemical-free thermal or ozone-compatible protocol |
| Power Input | AC 100–240 V, 50 Hz |
| Rated Power | 120 W |
| Dimensions (Reservoir Unit) | 280 × 490 × 555 mm (W×D×H) |
| (Main Unit w/ EZ-DSP Faucet) | 330 × 575 × 545 mm (W×D×H) |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYPR00SIA1 |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYPR0LSIA1 |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CYPR00S001 |
| Pricing | Available Upon Request |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium Mini |
| Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <1 ppt |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Daily Output Capacity | Up to 10 L |
| Footprint Width | 28 cm (37 cm with optional mobile dispensing unit) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 DI |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Operating Weight | 23.6 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <4 ppb |
| Particulates | <1 particle/mL @ ≥0.2 µm |
| Microbial Content | <1 CFU/mL |
| Flow Rate | 1.7 L/min |
| Application Suitability | AA, IC, ICP, ICP-MS, HPLC |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 UF |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Weight (dry/operational) | 16.8 / 25.3 kg |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | <4 ppb |
| Endotoxins | <0.001 EU/mL |
| Particles | <1 particle/mL @ ≥0.2 µm |
| Microbial count | <1 CFU/mL |
| Flow rate | 1.5 L/min |
| Filtration technology | Integrated ultrafiltration (UF) final polishing module |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 UV |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Weight (operational) | 24.8 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <1 ppb |
| Particulates | <1 particle/mL @ ≥0.2 µm |
| Microbial Content | <1 CFU/mL |
| Flow Rate | 1.7 L/min |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 VF |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Unit Weight | 17.4 kg |
| Operating Weight | 26.4 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <1 ppb |
| Endotoxins | <0.001 EU/mL |
| Particles | <1 particle/mL @ ≥0.2 µm |
| Microbial Contamination | <1 CFU/mL |
| Flow Rate | 1.5 L/min |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® advance EDI |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Maximum Flow Rate | 10 L/h |
| Resistivity (at 25 °C) | 5–15 MΩ·cm |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 30 ppb |
| Particles (>0.1 µm) | < 1 particle/mL |
| Ion Removal Efficiency (EDI-based) | >99% for monovalent ions |
| Organic Removal (MW >300 Da) | >99% |
| Microbial Reduction | >99% (via integrated 0.22 µm final filter) |
| Storage | Integrated sealed bag-in-box reservoir (prevents ambient recontamination) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® Comfort I |
| Purified Water Grade | ASTM Type 3 |
| Ultrapure Water Grade | ASTM Type 1 |
| Resistivity | 18.2 MΩ·cm (at 25 °C) |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 2 ppb |
| Microbial Count | < 1 CFU/1000 mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate (Ultrapure) | up to 2 L/min |
| Flow Rate (Pure) | up to 3 L/min |
| Storage Tank Options | Bag-type, disposable, 42 L standard |
| Conductivity Monitoring | Inlet & outlet, temperature-compensated to 25 °C |
| UV Wavelengths | 185 nm & 254 nm |
| Final Filtration | Sartopore® 2 150 capsule filter (0.45 + 0.2 µm PES) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium® Comfort II |
| Pure Water Grade | ASTM Type II |
| Ultrapure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 2 ppb |
| Microbial Contamination | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Technology | Electrodeionization (EDI) + Dual-Stage Filtration + Integrated UV (185/254 nm, optional) |
| Storage | Sealed, single-use Arium® Bag Tank |
| Compliance | Meets ASTM D1193, ISO 3696, CLSI EP21-A, and supports GLP/GMP data integrity requirements |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium® Mini Extend |
| Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <1 ppt |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Daily Output Capacity | Up to 10 L |
| Footprint | 28 cm width (base unit) |
| Display | Full-color capacitive touchscreen interface |
| Feedwater Compatibility | Pre-treated water (e.g., reverse osmosis or deionized feed) |
| Technology | Integrated Bagtank™ disposable reservoir system |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® Pro Basic |
| Purified Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 1000 ppb (feed water) / < 20 ppb (product water) |
| Particles (> 0.2 µm) | < 1 per mL |
| Bacteria | < 1 CFU/1000 mL |
| Feed Water Requirements | DI, RO, or EDI with conductivity ≤ 100 µS/cm, TOC ≤ 1000 ppb, turbidity < 1 NTU, silica < 1000 ppb, minimum inlet pressure 6.9 bar |
| Max. Flow Rate | 2 L/min at 2 bar |
| Dimensions (W×D×H) | 350 × 451 × 492 mm |
| Weight (empty/fully loaded) | 17 kg / 27 kg |
| Power Supply | 100–240 V AC, 50–60 Hz, max. 130 VA |
| Interfaces | RS232 (printer), touchscreen GUI with real-time monitoring and service alerts |
| Compliance | Meets or exceeds ASTM D1193-23, ISO 3696:1987, USP <1231>, CLSI EP21-A |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® pro |
| Water Grade | ASTM Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm |
| Heavy Metals & Soluble Silica | <0.1 ppm |
| Total Organic Carbon (TOC) | ≤2 ppb |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1/mL |
| Microbial Count | <1 CFU/1000 mL |
| UV Lamps | Dual-wavelength (185 nm & 254 nm) |
| Ultrafiltration Module | 5 kDa MWCO |
| Final Filtration | Sartopore® 2 150, 0.45 + 0.2 µm PES |
| Conductivity Monitoring | Inlet & Outlet |
| Data Storage | SD card, RS-232, optional printer interface |
| User Interface | Touchscreen glass panel with PIN-protected configuration |
| Flow Rate | Adjustable 0.1–2.0 L/min (manual), programmable quantitative/timed dispensing |
| Brand | SENTE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | STER02 |
| Output Capacity | Six independent, individually controllable steam channels |
| Steam Purity | Grade I Ultra-Pure Steam (compliant with GB/T 6682–2008 for laboratory water specifications) |
| Safety Features | Auto-dry-run prevention, auto-refill upon low-water detection, anti-siphon (anti-backflow) design |
| Dimensions (W×D×H) | 400 × 450 × 550 mm |
| Rated Power | 2600 W |
| Application Scope | Steam distillation in food, pharmaceutical, environmental, and traditional Chinese medicine (TCM) analysis |
| Brand | Sievers/Veolia |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PURELAB Flex |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | CYPAKBI0M1 |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Model | CYPAKFINM1 |
| Origin | Shanghai, China |
| Product Type | Point-of-Use (POU) Terminal Filtration Cartridge |
| Application | Final-stage purification in ultra-pure water (UPW) distribution loops |
| Filtration Rating | 0.22 µm (standard), optional 0.1 µm |
| Housing Material | Medical-grade polypropylene (PP) with EPDM or silicone gasket |
| Max Operating Pressure | 6 bar (87 psi) |
| Max Operating Temperature | 80 °C |
| Sterilization Compatibility | Autoclavable (121 °C, 30 min), gamma irradiation (25–40 kGy), and ethylene oxide (EtO) compatible |
| Certifications | ISO 9001, ISO 13485, USP Class VI compliant |
| Integrity Testable | Yes (forward flow or bubble point test per ASTM F838) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super-Q Plus |
| Flow Rate | 10–12 L/min |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <20 ppb |
| Microbial Count | <10 CFU/mL |
| Heavy Metals | <0.01 ppm |
| Silicates | <0.01 ppb |
| Total Dissolved Solids (TDS) | <0.03 ppm |
| Dimensions (H × W × D) | 80 × 94.5 × 22 cm (31.5 × 37.2 × 8.7 in) |
| Net Weight | 32.7 kg (72 lb) |
| Power Supply | 120 V / 60 Hz or 230 V / 50 Hz |
| Pump Motor Rating | 0–33 H.P. |
| Feed Water Requirement | Reverse Osmosis (RO) Grade Water |
| Primary Purification Modules | Organex-Q Cartridge, Durapore Membrane Cartridge |
| Brand | ELGA Veolia |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TERION™ S |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | ≥10 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <100 ppb |
| Recovery Rate | ~70% |
| Desalination Efficiency | >99.5% |
| Membrane Technology | RO + Continuous Electrodeionization (CEDI) |
| System Architecture | Skid-mounted, Plug-and-Play |
| Control Interface | Hubgrade HMI/PLC Integrated Panel |
| Validation Support | FAT (Factory Acceptance Test) Wet Commissioning Protocol |
| Compliance | Meets ASTM D1193, ISO 3696, CLSI EP21-A, and EU GMP Annex 1 water system design principles |
| Brand | The Lab |
|---|---|
| Origin | USA |
| Model | Dura Elit10 |
| Purified Water Grade | Type I (ASTM D1193-20, ISO 3696:1987, USP <1231>, EP 2.2.45) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Integrated TOC Monitor | 0.5–999.9 ppb, ±0.1 ppb accuracy |
| Daily Production Capacity | Up to 240 L of Type II water (≥5 MΩ·cm, TOC <30 ppb) and 10 L/h of Type I water |
| [Brand | The Lab |
|---|---|
| Origin | USA |
| Model | Dura |
| Purification Grade | Type I (ASTM D1193-20, USP <1231>, CLSI A2-A4, EP 2.2.44, CAP/ISO 15195) |
| Resistivity | 18.2 MΩ·cm at 25°C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| DI Water Resistivity | >16 MΩ·cm |
| RO Water Conductivity | 1–5 µS/cm |
| Flow Rate | Up to 2.0 L/min |
| Dimensions | 545 × 470 × 610 mm |
| Weight | ~16 kg |
| Power | 220 V, 50 Hz, 240 W] |
| Brand | The Lab |
|---|---|
| Origin | USA |
| Model | Super |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.01 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Production Rate | 10 L/h (RO/EDI), Up to 2.0 L/min (UP water, tank-fed) |
| Integrated TOC Monitor | Yes |
| Compliance | ASTM D1193, ISO 3696, USP <643>, EP 2.2.44, JP 16, CLSI A2, CAP, GB/T 6682-2008, GB/T 33087-2016 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Aquanex Ultra-Pure Water System |
| Pricing | Upon Request |
| Water Purity Grade | ASTM Type I (Ultra-Pure Water) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | GenPure Pro |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25°C |
| TOC | 1–5 ppb |
| Microbial Count | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | ≤ 0.003 ng/mL |
| DNase | ≤ 0.4 pg/µL |
| UV Wavelength | 185 nm / 254 nm |
| Conductivity Sensor Electrode Constant | 0.01 cm⁻¹ |
| Temperature Accuracy | ±0.1°C |
| Dispensing Accuracy | ±0.5% (0.01–65 L) |
| Data Logging | Last 4 weeks of system errors |
| Compliance | ASTM D1193, ISO 3696, CLSI, USP <645>, GLP |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Ultra-Pure Water System |
| Model | LabTower EDI |
| Pure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm |
| TOC | 1–5 ppb |
| Microbial Content | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate Options | 15 L/h or 30 L/h |
| Integrated Storage Tank | 100 L PE tank with recirculation loop and sterile air filter |
| UV Option | Available |
| CO₂ Absorber | Optional |
| Compliance | ASTM D1193, ISO 3696, USP <645>, GLP-ready, FDA 21 CFR Part 11–compatible data logging |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | LabTower RO |
| Output Flow Rate | 20 L/hr or 40 L/hr |
| Storage Tank Capacity | 100 L (HDPE, light-blocking) |
| Resistivity Monitoring | Yes (electrode constant 0.16 cm⁻¹) |
| Conductivity/Resistivity Display | Backlit LCD with tilt adjustment |
| Operating Modes | Production, Standby, Cleaning |
| Tank Level Indication | % display |
| Data Logging | RS-232 interface with optional printer support |
| GLP Compliance | Yes (audit-trail capable, password-protected parameter settings) |
| Pretreatment | Integrated antiscalant cartridge, 5 µm sediment filter, activated carbon filter |
| RO Membrane Protection | Antiscalant + carbon prefiltration |
| TOC Reduction | ≥99% |
| Particulate Removal (>0.1 µm) | ≥99% |
| Ionic Impurity Removal | ~98% |
| Application Grade | ASTM Type III Reagent Water (per ASTM D1193-20) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | LabTower TII |
| Output Flow Rate | 20 or 40 L/hr |
| Integrated Storage Tank Capacity | 100 L (conical, light-blocking polypropylene) |
| Resistivity | 10–15 MΩ·cm at 25 °C |
| TOC | < 30 ppb |
| Particulates (>0.1 µm) | < 1 particle/mL |
| Compliance | ASTM D1193 Type II, ISO 3696 Grade 2, CLSI-CLRW |
| Temperature Control Accuracy | ±0.1 °C |
| Conductivity Cell Constant | 0.01 cm⁻¹ with automatic temperature compensation |
| Pre-filtration | 5 µm sediment filter + activated carbon cartridge |
| Anti-scaling Cartridge | Integrated scale inhibition for RO membrane protection |
| RO Membrane Rejection | ≥97–99% of inorganic ions, ≥99% of organic compounds, microorganisms, and particulates |
| Final Polishing | Low-TOC, high-capacity mixed-bed ion exchange resin |
| Optional UV Module | 185/254 nm dual-wavelength germicidal lamp (for microbial control) |
| Data Interface | RS-232 with GLP-compliant audit trail and optional thermal printer support |
| User Interface | Backlit 4-line LCD display with password-protected parameter access |
| Operating Modes | Production, Standby (continuous recirculation), Cleaning |
| Tank Drainage | Full emptying via conical bottom geometry |