Ultra Pure Water System
Filter
Showing 301–330 of 372 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | MicroPure |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | 1–5 ppb |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate | ≤ 1 L/min |
| Dimensions (W×D×H) | 305 × 300 × 455 mm (without tank) |
| Power Consumption | 0.06 kW |
| Feed Water Requirement | RO/DI/distilled water with conductivity < 5 µS/cm, TOC ≤ 50 ppb, bacteria < 100 CFU/mL, turbidity < 1.0 NTU, temperature 2–35°C, pressure 0.1–6 bar |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Pacific RO |
| Purified Water Grade | ASTM Type III |
| Ion Removal Efficiency | 98% |
| TOC Reduction | 99% |
| Particulate Removal (>0.1 µm) | 99% |
| Pre-filter Configuration | Dual 10-inch (25.4 cm) Cartridges — 5 µm Sediment Filter + Activated Carbon + Anti-scaling Column |
| Resistivity Probe Accuracy | ±0.16 cm⁻¹ |
| Display | Backlit Tilt-adjustable LCD with Real-time Resistivity/Conductivity, Tank Level (%), and Operational Mode Indication |
| Control System | Microprocessor-based with GLP-compliant Event Logging, Password-protected Settings, and RS-232 Data Export (Configurable Interval) |
| Storage Tank | Polyethylene (Pigment-free), Conical-bottom Design for Complete Drainage |
| Footprint | Benchtop or Wall-mountable |
| Flow Rates | 3 / 7 / 12 / 20 / 40 L/hr |
| Data Retention | Up to 4 Weeks of Timestamped System Events and Parameters |
| Compliance | Meets ASTM D1193-20 (Type III Water), Supports GLP/GMP Documentation Requirements |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Pacific TII |
| Output Flow Rates | 3 / 7 / 12 / 20 / 40 L/hr |
| Resistivity | 10–15 MΩ·cm at 25 °C |
| TOC | <30 ppb |
| Particulates (>0.1 µm) | <1 particle/mL |
| Display | Backlit adjustable-angle LCD with resistivity/conductivity, status mode, tank level (%), and temperature (±0.1 °C per USP <645>) |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| Compliance | GLP-supporting data logging via RS-232 printer interface |
| Installation | Benchtop or wall-mounted |
| Scalability | Field-upgradable to higher flow capacity |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Ultra-Pure Water System |
| Models | 50129845, 50129688, 50129870, 50129872 |
| Purified Water Grade | ASTM Type I (ISO 3696 Grade 1) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | 1–5 ppb |
| Microbial Contamination | < 0.001 EU/mL |
| Particulates (>0.1 µm) | < 1 particle/mL |
| UV Lamp & UF Filter | Optional |
| CO₂ Absorber | Optional |
| Integrated Reservoir | 6 L (Smart2Pure 3/6), 30 or 60 L (Smart2Pure 12) |
| Circulation Pump | Integrated |
| Wall-Mountable | Yes |
| Display | Tilt-adjustable LCD |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Smart2Pure Pro UV/UF 16 LPH |
| Pure Water Grade | ASTM Type I |
| Resistivity | 1–10 MΩ·cm |
| Heavy Metals & Soluble Silica | <0.1 ppm |
| Total Organic Carbon (TOC) | 1–5 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported (Manufactured Outside China) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | 1–5 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | ≤ 0.003 ng/mL |
| DNase | ≤ 0.4 pg/µL |
| UV Wavelengths | 185 nm & 254 nm |
| Flow Rate | ≤ 2 L/min (up to 1.2 L/min at point-of-use arm) |
| Dimensions (W×D×H) | 372 × 330 × 615 mm (main unit) |
| Desktop xCAD arm | 260 × 530 × 725 mm |
| Wall-mounted xCAD arm | 260 × 530 × 655 mm |
| Power Consumption | 0.1 kW |
| Inlet Requirements | RO/DI/distilled water, conductivity < 2 µS/cm (xCAD-specific), TOC ≤ 50 ppb, pressure 0.1–6 bar, temp. 2–35 °C |
| Compliance | ASTM D1193, ISO 3696, CLSI CLRW, USP <645>, GLP/GMP-ready with audit trail and password protection |
| Interface | RS-232 with configurable logging interval |
| Data Storage | Error log history for up to 4 weeks |
| Certifications | IQ/OQ documentation available (E5013318 for xCAD series) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Nanopure Life Science Series |
| Pricing | Available Upon Request |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | 1–5 ppb |
| Endotoxin | <0.001 EU/mL |
| Bacterial Count | <1 CFU/mL |
| Particles (>0.2 µm) | <1 /mL |
| Silica | <1 ppb |
| UV Absorbance @ 254 nm | <0.001 AU |
| Flow Rate | 1.8 L/min |
| Feed Water Requirements | Pre-treated RO, distilled or deionized water |
| Pressure | 100 psi (6.9 bar) |
| Temperature | 4–40 °C |
| Intelligent Dispensing Range | 0.25–60 L |
| Accuracy | ±5% (≥1 L), Repeatability: ±3% |
| Conductivity Cell Constant | 0.1 cm⁻¹ |
| Temp. Sensor Accuracy | ±0.1 °C |
| Dimensions (W×H×D) | 34.3 × 49.5 × 43.2 cm |
| Installation | Benchtop or wall-mounted (included bracket) |
| Service Clearance | Side >22.9 cm, Top >7.6 cm, Front >12.1 cm |
| Power | 90–240 VAC, 100 VA, 47–63 Hz, Single Phase |
| Tubing | Feed line Ø11.43 mm (supplied), Drain line Ø7.62 mm (supplied) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Nanopure Series |
| Flow Rate | >1.6 L/min |
| Resistivity | >18.2 MΩ·cm |
| Total Organic Carbon (TOC) | <5 ppb |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.2 µm) | <1 particle/mL |
| UV Absorbance (254 nm) | <0.0001 AU |
| Silica | <3 ppb |
| Conductivity Calibration Option | NIST-traceable module available |
| Compliance | ASTM D1193 Type I, NCCLS (now CLSI) EP21-A, CAP guidelines |
| Certifications | CSA, CE |
| Power Input | 90–240 VAC, 47–63 Hz |
| Interface | RS-232 for data logging and printer/computer connectivity |
| Remote Display | Optional wall-mount or under-bench installation supported |
| Real-time TOC monitoring | Standard |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Labonova Central RO |
| Purification Technology | Single-stage reverse osmosis (RO) |
| Feed Water Conductivity Range | Up to 1,000 µS/cm |
| Product Water Conductivity | <20 µS/cm (at 25 °C, dependent on feed water quality) |
| Salt Rejection Rate | ≥98% |
| Interface | RS232 serial communication port |
| System Architecture | Centralized, modular, closed-loop distribution-capable |
| Compliance | Designed for ISO 3696 Grade 3 and ASTM D1193 Type IV water production |
| Configuration | Customizable with external storage tanks, booster pumps, and recirculation loops |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Direct |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Pure Water Output | 10 L/h (Type III, ISO 3696) |
| Ultrapure Water Output | 1.5 L/min (Type I, ASTM D1193 / ISO 3696 / CLSI A2 / CAP) |
| Integrated Storage Tank | 7 L |
| RO Recovery Rate | >75% |
| UV Wavelengths | 185 nm & 254 nm |
| Final Resistivity | ≥18.2 MΩ·cm at 25 °C |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Direct Pro S |
| Pure Water Grade | ASTM Type II |
| Ultrapure Water Grade | ASTM Type I |
| Conductivity (Pure Water) | 0.1–0.2 µS/cm |
| Resistivity (Ultrapure Water) | 18.2 MΩ·cm @ 25 °C |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Pure Water Flow Rate | 16 L/h |
| Ultrapure Water Flow Rate | 2.0 L/min |
| RO Recovery Rate | >75% |
| UV Options | Dual-wavelength (185/254 nm) UV Lamp |
| TOC Monitoring | Integrated Online TOC Sensor |
| Display | 7″ Full-Color Touchscreen (Multilingual: EN/DE/FR/CN) |
| Installation | Benchtop or Wall-Mountable |
| Distribution | Two Independent Dispensers (Fixed + Extendable Handheld) |
| Internal Recirculation | Automated Flush Cycle |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Direct Pro+ |
| Purified Water Grade | ASTM Type II |
| Ultrapure Water Grade | ASTM Type I |
| Conductivity (Type II, 25°C) | 0.06–0.2 µS/cm |
| Resistivity (Type I, 25°C) | 18.2 MΩ·cm |
| Flow Rate (Type II) | up to 20 L/h |
| Flow Rate (Type I) | up to 2.0 L/min |
| TOC | <1–3 ppb |
| Microbial Count | <0.01 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Nuclease-Free (DNase/RNase/DNA) | Yes |
| Particles (>0.2 µm) | None detectable |
| Integrated Modules | RO + EDI + UV (dual-wavelength 185/254 nm) + UF + TOC Monitor |
| Display | 7-inch color touchscreen (multi-language: English, German, French, Chinese) |
| Dimensions (H×W×D) | 530 × 900 × 320 mm |
| Weight | 46 kg |
| Power Supply | 100–240 V / 50–60 Hz |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Smart |
| Feed Water | Type I purified water (deionized, distilled or RO) |
| Product Water Resistivity | ≥18.2 MΩ·cm @ 25°C |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Flow Rate | Up to 1.5 L/min |
| Feed Pressure Range | 0.1–6 bar |
| Integrated UV | Dual-wavelength (185 nm + 254 nm) |
| Final Filtration | 0.2 µm charged polyethersulfone (cPES) end-filter |
| Conductivity Monitoring | Dual-channel (feed & product) |
| Sanitization Method | Injection-based chemical recirculation sanitization |
| System Footprint | Compact integrated design |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Labonova Ultra Pro |
| Feed Water | Type I purified water |
| Product Water Grade | ASTM D1193 Type I / ISO 3696 Class 1 / CLSI EP28-A3c compliant |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <1 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Flow Rate | Up to 2 L/min |
| UV Source | Dual-wavelength (185 nm + 254 nm) low-pressure mercury lamp |
| Final Filtration | Preventor 5000 ultrafiltration membrane (3-year service life) |
| Display | 7-inch full-color capacitive touchscreen with multilingual UI (English, German, Chinese) |
| Data Export | SD card interface |
| Acoustic Noise Level | <40 dBA |
| Compliance | Designed for GLP/GMP environments |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower (OEM/ODM Capable) |
| Type | Domestic |
| Model | TP301 |
| Purified Water Grade | ASTM Type III / GB/T 6682 Class III |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count | < 0.001 EU/mL |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Feed Water | Municipal tap water |
| RO Rejection Rate | > 99% |
| Final Filtration | 0.22 µm hydrophilic PES membrane |
| Dimensions (W×D×H) | 600 × 470 × 520 mm |
| Weight | 40 kg |
| Operating Temp. | 5–40 °C |
| Power Supply | 220 VAC, 50 Hz, ±10% voltage tolerance |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP301 / TP302 |
| Pure Water Grade | ASTM Type II / GB6682 Grade III |
| RO Permeate Conductivity | 0–50 µS/cm |
| Ultra-Pure Water Resistivity | 18.25 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | <10 ppb |
| Particles (>0.22 µm) | <1/mL |
| Bacteria | <0.1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Silica (as SiO₂) | <10 ppb |
| Heavy Metals (e.g., Fe, Cu, Ni, Cr, Zn, Na, K, Al) | <0.1–20 ppb |
| Cation/Anion Residuals | Cl⁻ <0.01 ppb, NO₂⁻ <0.02 ppb, NO₃⁻ <0.02 ppb, SO₄²⁻ <0.01 ppb |
| Terminal Filtration | 0.22 µm hydrophilic membrane |
| Operating Temperature | 5–40 °C |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 600 × 470 × 520 mm |
| Weight | 40 kg |
| Feed Source (TP301) | Municipal tap water |
| Feed Source (TP302) | Pre-treated RO or distilled water |
| Integrated Features | LCD touchscreen interface, automated backwash cycle, programmable ultra-pure water recirculation, real-time resistivity monitoring, quantitative dispensing, DC ultra-pure water delivery pump |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP301 / TP302 |
| Pricing | Available Upon Request |
| Purified Water Grade | ASTM Type III (Lab-Grade Purified Water) |
| Ultra-Pure Water Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count | < 0.001 EU/mL |
| Particulates (>0.1 µm) | < 1 particle/mL |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TP301 / TP302 |
| Pricing | Available Upon Request |
| Purified Water Grade | ASTM Type II |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 3 ppb |
| Microbial Count & Endotoxins | < 0.001 EU/mL |
| Particulates (>0.1 µm) | < 1 particle/mL |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | GenPure UV-TOC/UF xCAD |
| Price | Upon Request |
| Feed Water | Distilled / RO / DI Water |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Conductivity | 0.055 µS/cm @ 25 °C |
| TOC | 1–5 ppb |
| Endotoxin | ≤ 0.001 EU/mL |
| RNase | < 0.01 ng/mL |
| DNase | < 4 pg/µL |
| Microbial Count | ≤ 1 CFU/mL |
| Flow Rate | 0–2 L/min (continuously adjustable) |
| Dispense Volume Range | 0.01–65.0 L (programmable) |
| Real-time In-line TOC Monitoring | Yes (full-loop, non-sampling) |
| UV Lamp Intensity Monitoring | Dual-wavelength (185 nm & 254 nm) with real-time energy % display (UV intensity sensor, not timer-based) |
| Temperature Sensor Accuracy | ±0.1 °C |
| System-wide Wetted-Path Sanitization | Yes (including UF, storage loop, and distribution lines) |
| Remote Control | xCAD controller (up to 3 arms, 3 m max distance, 180° rotation, 0.8 m arm extension, max dispense flow 1.2 L/min) |
| Display | 4-line adjustable-angle LCD with auto-diagnostics, maintenance alerts, and alarms |
| Interface | RS232 for PC or dedicated printer connectivity |
| Standard Configuration | Main unit (integrated TOC analyzer, dual conductivity sensors, PT100 temperature probe, UV intensity sensor, UF module, dual-wavelength UV lamp), one integrated purification cartridge, terminal 0.22 µm filter |
| Brand | ELGA Veolia |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | TRITON |
| Pure Water Grade | ASTM Type II |
| Resistivity | 1–18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <10 ppb |
| Microbial Count | <0.25 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Flow Rate Options | 160, 240, 350, or 480 L/h |
| Brand | Truelab |
|---|---|
| Origin | Jiangsu, China |
| Model | GREEN-Q2-5T / GREEN-Q2-10T |
| Output Capacity | 5 L/h / 10 L/h |
| Resistivity | 13–17.5 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 10 ppb |
| Microbial Count | < 1 CFU/mL |
| Particles (>0.2 µm) | < 1 particle/mL |
| Feed Water Requirement | Municipal tap water (TDS < 200 ppm, 5–45 °C, pressure 1.0–4.0 kgf/cm²) |
| RO Rejection Rate | >99% for ions, >99% for organics (MW > 200 Da), >99% for particles & bacteria |
| Power Supply | 220 V, 50 Hz, 50–80 W |
| Noise Level | <50 dB(A) |
| Dimensions (W×D×H) | 315 × 440 × 470 mm |
| Weight | ~18 kg |
| Certifications | NSF-certified tubing & fittings, food-grade PP resin cartridges, DOW RO membranes |
| Brand | Truelab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | E2-TS / E2-TH / E2-TF / E2-TJ |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Purified Water Grade | ASTM Type I (Ultra-Pure), GB/T 6682-2008 Grade I |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb (E2-TS/E2-TF), <5 ppb (E2-TH), <10 ppb (E2-TJ) |
| Endotoxin | <0.001 EU/mL (E2-TS/E2-TF), <0.002 EU/mL (E2-TH) |
| Microbial Count | <0.1 CFU/mL |
| Particles (>0.2 µm) | <1 CFU/mL |
| RNase | <0.01 ng/mL (E2-TS/E2-TF) |
| DNase | <4 pg/µL (E2-TS/E2-TF) |
| Feed Water Requirement | Municipal tap water, TDS <200 ppm, 5–45 °C, pressure 1.0–4.0 kgf/cm² |
| Flow Rate | 5–40 L/h (adjustable), instantaneous output 1.5–2.0 L/min (with pressurized tank) |
| Dimensions (W×D×H) | 500 × 400 × 580 mm |
| Weight | ~38 kg |
| Power | 220 VAC, 50 Hz, 50–80 W |
| Noise Level | <50 dB(A) |
| Certifications | NSF-certified tubing and fittings, RO membrane: Dow FilmTec™, UV lamp: dual-wavelength (185/254 nm), low-voltage DC control architecture (24 VDC), IPX1-rated enclosure |
| Brand | Truelab |
|---|---|
| Origin | Germany |
| Model Variants | S2-DS, S2-DH, S2-DF, S2-DJ |
| Feed Water Requirement | Deionized Water (≤3 µS/cm) |
| Product Water Grade | ASTM Type I / ISO 3696 Class 1 / GB/T 6682–2008 Grade I |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb (S2-DS/S2-DJ), <5 ppb (S2-DH), <10 ppb (S2-DF) |
| Endotoxin | <0.001 EU/mL (S2-DS/S2-DF), <0.002 EU/mL (S2-DH) |
| Bacteria | <0.1 CFU/mL |
| Particles (>0.2 µm) | <1 CFU/mL |
| RNase | <0.01 ng/mL (S2-DS/S2-DF) |
| DNase | <4 pg/µL (S2-DS/S2-DF) |
| Flow Rate | 10–90 L/h (adjustable), Instantaneous Output: 1.5–2.0 L/min |
| Dimensions (W×D×H) | 500 × 400 × 580 mm |
| Weight | ~38 kg |
| Power Supply | 220 V, 50 Hz, 50–80 W |
| Noise Level | <50 dB(A) |
| Conductivity Sensor Cell Constant | 0.01 cm⁻¹, Temp. Sensitivity: ±0.1 °C with Automatic Temperature Compensation |
| Safety | 24 VDC Low-Voltage Primary Power, NSF-Certified Tubing & Fittings, IPX4-Rated ABS Housing, Electrical/Water Separation Architecture |
| Brand | TTL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | TTL-10A |
| Price Range | USD 1,400 – 4,200 |
| Purified Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm at 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <10 ppb |
| Microbial Count | <0.001 EU/mL |
| Particulates (>0.1 µm) | ≤0.22 particles/mL |
| Feed Water | Municipal tap water |
| Production Rate | 10 L/h |
| Brand | TTL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TTL-10B |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Purified Water Grade | ASTM Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 5 ppb |
| Bacterial Count | < 1 CFU/mL |
| Endotoxin Level | < 0.001 EU/mL |
| Particulates (>0.22 µm) | < 1 particle/mL |
| Production Rate | 23 L/h |
| Feed Water | Municipal tap water |
| Primary Purification Stage | RO + Dual-Stage Ion Exchange + UF + UV (185/254 nm) |
| System Housing | Full non-metallic polymer enclosure |
| Control Interface | Microprocessor-based Chinese-language LCD menu |
| Auto Functions | Power-on self-diagnostic, RO membrane auto-flush, real-time temperature monitoring, continuous online resistivity & TOC monitoring |
| Brand | TTL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TTL-20B |
| Price Range | USD 1,400 – 4,200 |
| Purified Water Grade | ASTM Type II / GB/T 6682–1992 Grade II |
| Resistivity | ≥10 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica Removal Efficiency | 94–99% |
| Total Organic Carbon (TOC) | <10 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Particulate Removal (>0.1 µm) | >99% |
| Feed Water | Municipal Tap Water |
| Production Flow Rate | 23 L/h |
| Conductivity of Purified Water | <5 µS/cm |
| Housing Material | Full Polypropylene (PP) Construction |
| Control System | Embedded Microprocessor with Chinese GUI |
| Dual-Stage Purification | Integrated RO + Mixed-Bed Ion Exchange + Activated Carbon + UF |
| Auto-RO Flush | Yes |
| Self-Diagnostic Startup | Yes |
| Cartridge Replacement Alert | Yes |
| Brand | TTL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TTL-30C |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 10 ppb |
| Endotoxin | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/mL |
| Particulates (>0.22 µm) | < 1 /mL |
| Feed Water | RO water, distilled water or deionized water |
| Flow Rate | 25 L/h |
| Housing Material | Full polymer enclosure (non-metallic, corrosion-resistant) |
| Control System | Microprocessor-based with bilingual (Chinese/English) LCD interface |
| Purification Stages | Dual-stage polishing cartridge system (including final 0.22 µm hydrophilic PES membrane filter and integrated UV lamp at 185/254 nm) |
| Maintenance Features | Real-time consumables monitoring, automatic self-diagnostic at power-on, manual recirculation mode, visual & audible replacement alerts |
| Brand | TTL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | TTL-7 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Feed Water | Potable municipal tap water (TDS < 200 mg/L) |
| Product Flow Rate | 25 L/h |
| Resistivity | ≥10 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica Removal Efficiency | >99% |
| Total Organic Carbon (TOC) | ≤10 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Compliance | GB/T 6682–1992 Grade III water |
| Housing Material | Corrosion-resistant engineering plastic |
| Electrical/Water Path Isolation | Fully segregated design |
| Control Interface | Microprocessor-based with LCD display, Chinese menu (configurable for English firmware), real-time parameter monitoring, auto-diagnostic startup, timed dispensing, RO membrane auto-flush/manual flush, consumables life tracking, temperature & clock display, auto-drain function |
| Pre-treatment | Integrated sediment + activated carbon + polypropylene depth filtration |
| Core Purification Stages | Single-pass RO + mixed-bed ion exchange + 0.22 µm final filter |
| Optional Upgrade Path | Compatible with downstream Millipore (Merck) ultra-pure polishing modules (e.g., Milli-Q® IQ 7000 series feed interface) |
| Brand | TTL (Tongtai Lian) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TTL-6 |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Purified Water Grade | ASTM Type I / GB/T 6682-2008 Grade I |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 10 ppb |
| Endotoxin | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/mL |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Feed Water Requirement | Potable municipal supply, TDS < 200 mg/L |
| Flow Rate | 10 L/h or 25 L/h |
| Purification Stages | Single-pass RO + Dual-stage polishing cartridge system with real-time resistivity and TOC monitoring |
| Brand | ULUPURE |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ULPQX |
| Pricing | Upon Request |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Conductivity | ≤5 µS/cm (for double-pass RO configuration, at 25 °C) |