| Brand | GENESITE |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SJ-D80 NH₃-N |
| Instrument Type | Portable |
| Measurement Principle | Nessler Reagent Colorimetry (per HJ 535–2009) |
| Measurement Range | 0–150 mg/L NH₃-N |
| Accuracy | ±5% FS |
| Measurement Time | ≤10 min per sample |
| Sample Throughput | 1 sample per run |
| Display | 3.5″ TFT color touchscreen (320×480 px) |
| Optical Resolution | 0.001 Abs |
| Photometric Stability | ±0.003 Abs/30 min |
| Power Supply | 4 × AA alkaline batteries or 220 V AC adapter |
| Dimensions (L×W×H) | 192 × 96 × 103 mm |
| Weight | 0.5 kg (instrument only) |
| Data Export | SD card (FAT32 formatted, up to 32 GB) |
| Calibration Options | Built-in standard curve library + user-defined curve generation |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GR5050 |
| Instrument Type | Portable |
| Biological Indicator | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Storage Temperature Range | −10 °C to 50 °C |
| Operational Reagent Temperature Range | 5 °C to 45 °C |
| Time-to-Result | ≤15 minutes post sample preparation |
| Brand | Greencarey Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Laboratory-Grade COD Analyzer |
| Model | GL-200A |
| Detection Principle | Rapid Digestion Method (HJ/T 399–2007) |
| Wavelength Accuracy | ≤±0.001 Abs/20 min (Optical Source Lifetime: 100,000 hours) |
| Measurement Range | 0–15,000 mg/L (segmented) |
| Accuracy | ≤±5% (COD >50 mg/L) |
| Repeatability | ≤±3% |
| LOD | 5 mg/L |
| Digestion Temp/Time | 165 °C / 20 min |
| Total Cycle Time | 25 min/batch |
| Sample Throughput | 1 batch per 25 min |
| Chloride Interference Tolerance | up to 2,000 mg/L |
| Cuvette Format | 16 mm round digestion tube (no post-digestion transfer required) |
| Display | 4.3″ color TFT LCD |
| Data Output | USB flash drive export & built-in thermal printer |
| Optical System | Solid-state cold light source |
| Housing Material | ABS (chemical-resistant, heat-stable, impact-durable) |
| Power Supply | DC 12 V, 5 A |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Dimensions | 300 × 222 × 88 mm |
| Weight | ~2.8 kg |
| Compliance | HJ/T 399–2007 (COD), HJ 535–2009 (NH₃-N), GB/T 11893–1989 (TP), HJ 636–2012 (TN), and 18+ additional water quality parameters with standardized photometric methods |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200Cl |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameter | Free Chlorine (Cl₂) |
| Measurement Ranges | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ±0.001 ppm / ±0.01 ppm |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000, manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485 with standard MODBUS RTU protocol |
| Relay Output | 1 multifunctional relay (cleaning control, periodic alarm, fault alarm) |
| Data Logging | 600,000 records with timestamped query capability |
| Display | Backlit graphical LCD with adjustable contrast |
| User Interface | Bilingual (English/Chinese), password-protected, keyless operation with auto-backlight timeout |
| Mounting Options | Wall-mounted, panel-mounted, or pipe-mounted |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Range | 0–2.000 ppm / 0–20.00 ppm |
| Sensor Accuracy | ±2% FS |
| Sensor Electrode Material | Glass body with dual platinum ring working electrode |
| Sensor Operating Temperature | 0–70.0 °C |
| Max. Pressure Rating | 5 bar |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200I Chloride |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–30,000 mg/L Cl⁻ |
| Detection Limits | 0.01 / 0.1 / 1 ppm |
| Response Time | ≤30 s |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Operating Temperature | 0–70 °C |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Display | Backlit graphical LCD |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485 with MODBUS RTU protocol |
| Relay Output | 1 multifunctional relay (for cleaning control, periodic alarm, fault alarm) |
| Data Logging | Up to 600,000 records with timestamped retrieval |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Mounting Options | Wall-mounted, pole-mounted, panel-mounted |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Chloride Sensor | Bsens720 |
| Sensor Material | Polyphenylsulfone (PPS) |
| Electrode Max. Pressure | 3.5 bar |
| Cable Length | 5 m |
| Sensor Operating Temp. | -5 to 70 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON6000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Photometric Determination of Soluble Silica via Molybdenum Blue Reduction Method |
| Measurement Ranges | 1–100 ppb, 4–999 ppb, 0.02–3 ppm SiO₂ |
| Resolution | 0.1 ppb / 1 ppb / 0.01 ppm |
| Accuracy | ±2% of full scale |
| Repeatability | ±0.5 ppb / ±4 ppb / ±0.02 ppm |
| Zero Stability | Auto-zero compensation |
| Analysis Cycle | 13 min (standard), adjustable from 1–99 min or externally triggered |
| Dimensions (H×W×D) | 640 × 315 × 190 mm |
| Display | 240 × 128 pixel monochrome touchscreen |
| Analog Output | 0/4–20 mA (max. load 500 Ω) |
| Digital Interface | USB data logging (optional) |
| Relay Outputs | 3× SPDT zero-potential relays (alarm, limit, analysis), rated 230 V AC / 3 A |
| Environmental Operating Range | 5–45 °C |
| Power Supply | 110–230 V AC, 50/60 Hz |
| Enclosure Rating | IP65 |
| Power Consumption | ~16 VA |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROLEV800 |
| Pricing | Upon Request |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent ultrasonic transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Ambient Temperature | −20 to +60 °C |
| Display | Large-backlit LCD with graphical interface (numeric readout, trend plot, echo waveform) |
| Enclosure Rating | IP68 |
| Weight | 3.6 kg (transmitter), 3 kg per probe |
| Output Signal | 4–20 mA analog (isolated), dual high/low level alarms |
| Communication Interface | RS-232C (cable length ≤ 10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m |
| Brightness Adjustment | Yes |
| Trend Storage | 5 minutes to 48 hours on-screen history |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProLev800 |
| Price Range | USD 6,800 – 13,600 (FOB UK) |
| Measurement Principle | Ultrasonic Time-of-Flight (ToF) |
| Measuring Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent ultrasonic transducers |
| Accuracy | ±1 cm |
| Response Time | ≤1 s |
| Operating Ambient Temperature | −20 to +60 °C |
| Display | Backlit graphical LCD (digital height readout, real-time echo waveform, trend plot) |
| Output Signals | 4–20 mA analog (isolated), dual programmable Hi/Lo alarms |
| Communication Interface | RS232C (cable length ≤10 m) |
| Power Supply | 85–264 VAC, 50/60 Hz, max. 10 VA |
| Enclosure Rating | IP68 (transducer and housing) |
| Cable Length | 20 m standard |
| Weight | 3.6 kg (transmitter), 3.0 kg per sensor |
| Software Compatibility | PC-based configuration & data logging via RS232 |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU, IEC 61000-6-2/-4 |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company (a Danaher subsidiary) |
| Product Type | Imported |
| Model | 9184sc |
| Pricing | Available upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 9184sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (HOCl-selective Membrane) |
| Measurement Parameter | Free Chlorine (as HOCl) |
| Range | 0.005–20 ppm (mg/L) HOCl |
| Accuracy | ±2% of reading or ±10 ppb HOCl (whichever is greater) |
| Detection Limit | 5 ppb (0.005 mg/L) HOCl |
| Response Time (t₉₀) | <90 seconds |
| Sample Flow Rate | 200–250 mL/min (automatically regulated) |
| Operating Temperature | 0–45 °C |
| Sample Temperature Range | 2–45 °C |
| Sample pH Range | 4–8 |
| Calibration Interval | Every 2 months |
| Membrane & Electrolyte Replacement Interval | Every 6 months |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions | 270 × 250 mm |
| Storage Temperature | −20–60 °C |
| Inlet/Outlet Fittings | 1/4″ O.D. inlet, 1/2″ I.D. outlet |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BODTrak II |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Ranges | 0–35, 0–70, 0–350, 0–700 mg/L O₂ |
| Detection Limit | 0.01 mg/L O₂ |
| Accuracy | ±2% at 235 mg/L BOD |
| Repeatability | ±2% at 235 mg/L BOD |
| Incubation Temperature | 20 °C (±0.5 °C) |
| Sample Throughput | 6 samples per run (473 mL bottles) |
| Data Storage | 480 data points per sample |
| Display | Real-time graphical trace with cursor readout |
| Power Supply | AC adapter |
| Dimensions | 28.9 × 26.0 × 9.8 cm |
| Weight | 3.6 kg |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Hach licensing) |
| Model | BODTrak II |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Pressure Differential Method |
| Measurement Ranges | 0–35, 0–70, 0–350, 0–700 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ±1 mg/L |
| Incubation Duration | 5–10 days (user-selectable) |
| Incubation Temperature | 20 °C ±0.5 °C |
| Repeatability | 3–5% RSD |
| Sample Throughput | Up to 6 samples simultaneously |
| Data Logging Interval | Every 15 minutes |
| Total Data Points Storage | 480 |
| Software Interface | HachLink™ PC software (Windows-compatible) |
| Compliance | Designed to meet ASTM D5210, ISO 5815-1, and EPA Method 405.1 requirements for BOD₅ determination |
| Brand | HACH |
|---|---|
| Manufacturer Origin | Japan (DKK Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | SSM-21P |
| Pricing | Upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DR1010 COD |
| Instrument Type | Portable |
| Measurement Principle | UV-Visible Absorption Spectrophotometry |
| Wavelengths | 420 nm and 610 nm |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Wavelength Accuracy | ±1 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Detector | Silicon Photodiode |
| Power Supply | 190–240 V AC/50 Hz or 4×AA Alkaline Batteries |
| Environmental Rating | IP41 |
| Output Interface | RS232 Serial Port |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | DRB100 |
| Digestion Method | Sealed Micro-Reflex Digestion |
| Heating Module | Integrated Ceramic Heating Block |
| Batch Capacity | 4 samples |
| Temperature Range | Ambient to 180 °C |
| Temperature Accuracy | ±0.1 °C |
| Digestion Vessel Compatibility | Four 16 mm OD test tubes |
| Timer Accuracy | ≤±1 minute |
| Power Supply | DC 12 V, 120 W |
| Dimensions | 110 × 170 × 125 mm |
| Weight | 918 g |
| Compliance | Meets or exceeds requirements of HJ 828–2017 (China), ASTM D1252–04, ISO 6060 |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | DRB200 COD |
| Digestion Method | Rapid Digestion |
| Heating Modules | Dual Independent Heating Blocks |
| Batch Capacity | 30 samples (16 mm diameter tubes) |
| Temperature Range | 37–165 °C (98.6–329 °F) |
| Temperature Accuracy | ±2 °C (±3.5 °F) |
| Timer Accuracy | ±1 minute |
| Power Input (Dual Block) | 115 V: 600 VA |
| 230 V | 900 VA |
| Certifications | CE, GS, cTUVus |
| Protection Class | Class I |
| Operating Humidity | ≤90% RH (non-condensing) |
| Storage Temperature | −40 to +60 °C |
| Operating Temperature | 10 to 45 °C |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Hach EZ Series (EZ1000 for Dissolved Metals / EZ2000 for Total Metals) |
| Instrument Type | Online Analyzer |
| Detection Principle | Colorimetric Spectrophotometry (not ICP-OES — correction applied per technical accuracy) |
| Target Metals | Cu, Fe, Ni, Mn, Cr, Zn (Dissolved and/or Total forms) |
| Accuracy/Precision | ≤2% F.S. (with certified standard solutions) |
| Resolution | As specified in individual parameter datasheets |
| Sample Throughput | Up to 8-channel sequential analysis |
| Onboard Digestion | Integrated UV/persulfate digestion module (EZ2000 series only) |
| Output | 4–20 mA analog output with alarm thresholds |
| Communication | Modbus TCP/IP via Ethernet |
| Sample Volume per Analysis | <15 mL |
| Optical Path Length | Extended (≥50 mm) for enhanced sensitivity |
| Control Platform | Industrial-grade panel PC with embedded real-time OS |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer | Hach Company |
| Instrument Type | Portable |
| Detection Principle | Colorimetric Spectrophotometry |
| Measurable Metals | As, Cr(Total), Cr(VI), Cu, Ni, Zn, Cd, Pb |
| Measurement Range (Typical) | As 0–4000 ppb |
| Reagent Catalog Numbers | 2822800, 2242500, 1271099, 2105869, 2651600, 2429300, TNT852, TNT850 |
| Kit Configurations | HM01 (DR2800 + battery + MP6P probe), HM02 (DR2800 + battery + H170NP pH/ORP probe + PHW77-SS stainless steel probe), HM03 (no DR2800, includes MP6P), HM04 (no DR2800, includes H170NP + PHW77-SS) |
| Compliance | Designed for field use in accordance with EPA Method 200.7, ISO 11969, and ASTM D3559/D5191 for metals analysis in water |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | HQ1130 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| Range | 0.1–20.0 mg/L (ppm), 1–200% Saturation |
| Accuracy | ±0.1 mg/L |
| Ingress Protection | IP67 |
| Data Storage | Up to 10,000 Records |
| Compliance | GLP-Compliant Logging, ASTM D888, ISO 5814, USP <643>, EPA Method 4500-O G |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LDO10103 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Range | 0.00–20.0 mg/L, 0–200% saturation |
| Accuracy | ±1% of full scale |
| Repeatability | ±1% |
| Detection Limit | 0.01 mg/L (or 0.1 mg/L depending on configuration) |
| Brand | Hach |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MS5100 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Electrochemical Detection (Free Chlorine & Chlorine Dioxide), Nephelometry (Turbidity), Potentiometric (pH & ORP), Conductometric (Conductivity) |
| Measured Parameters | Free Chlorine, Chlorine Dioxide, Turbidity, pH, ORP, Conductivity, Temperature |
| Measurement Ranges | Free Chlorine: 0–10 mg/L as Cl₂ |
| Chlorine Dioxide | 0–5 mg/L |
| Repeatability | Free Chlorine: ±1% or ±0.01 mg/L (whichever is greater) |
| Chlorine Dioxide | ±1.5% or ±0.01 mg/L (whichever is greater) |
| Detection Limit | 0.008 mg/L Cl₂ (at 25 °C) |
| Accuracy | ±10% (4–5 mg/L Cl₂ range) |
| Sample Temperature Range | 5–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Dimensions | 342 mm × 329 mm × 177 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Online TOC Analyzer |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Online TOC Monitoring System |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Methods | UV/Persulfate, High-Temperature Combustion (680–900 °C), Ozone-Promoted Oxidation, Ultra-Pure UV Oxidation |
| Measurement Range | 0–50,000 ppm C |
| Accuracy | ±1% of reading |
| Resolution | 0.05 ppm C |
| Detection Limit | 0.05 ppm C |
| Repeatability | ±1% RSD |
| Sample Throughput | As low as 3 minutes per analysis (configuration-dependent) |
| Dimensions (H×W×D) | 575 × 556 × 612 mm |
| Weight | 60 kg |
| Power Supply | 220 VAC, 10 A |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | QbD1200+ |
| Oxidation Method | UV/Persulfate |
| Measurement Range | 0–100 ppm |
| Detection Limit | 3 ppb |
| Accuracy | ±3% |
| Precision (RSD) | <2% |
| Compliance | FDA 21 CFR Part 11, USP <643>, EP 2.2.44, JP 2.59, ISO 8245, ASTM D5903 |
| Operating System | Pre-installed Microsoft Windows 10 IoT Enterprise |
| Display | 10.4-inch capacitive touchscreen |
| Data Storage | 256 GB SSD |
| Sample Introduction | Manual or optional 64-position autosampler (40 mL vials) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | SP510 |
| Detection Principle | Colorimetric (EDTA Complexometric Titration) |
| Measurement Range | 0.3–100 mg/L as CaCO₃ |
| Accuracy | ±10% of setpoint (0.3–2 mg/L), ±4% of setpoint (5–100 mg/L) |
| Cycle Time | ~2 minutes per measurement |
| Alarm Output | 1 SPDT relay |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL, CSA, CE |
| Reagent Consumption | Up to 2 months per reagent pack |
| Maintenance Interval | Pump tube replacement every 6 months |
| Calibration | Automatic on-demand and scheduled calibration |
| Brand | Hach |
|---|---|
| Model | SP510 |
| Origin | USA |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Colorimetric Method (Calcium/Magnesium Complexation with Arsenazo III) |
| Measured Parameter | Total Hardness (as CaCO₃) |
| Range | 0.3–100 mg/L as CaCO₃ |
| Repeatability | ≤4% RSD |
| Accuracy | ±10% of setpoint at 0.3–2 mg/L |
| Cycle Time | ~2 minutes per measurement |
| Calibration | Automatic on-board standardization using factory-preloaded reagent cartridges |
| Reagent Consumption | One cartridge supports ~60 days of continuous operation |
| Maintenance Interval | Pump tubing replacement every 6 months |
| Alarm Outputs | 1 SPDT relay (configurable setpoints: 0.3, 1, 2, 5, 10, 20, 50, 100 mg/L) |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL 61010-1, CSA C22.2 No. 61010-1, CE marked per EMC and LVD directives |
| Compliance | Designed for use in industrial water treatment environments requiring GLP-aligned operational traceability |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HGCF-100 for Ammonia Nitrogen |
| Price Range | USD 28,000 – 35,000 |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Air-Segmented Continuous Flow Analysis (CFA) with Distillation and Colorimetric Detection |
| Measurement Range | 0.01–5 mg/L NH₃–N |
| Accuracy | ±1% of reading |
| Detection Limit | ≤0.005 mg/L NH₃–N |
| Sample Throughput | 30 samples/hour |
| Batch Capacity | Unlimited (software-controlled queue) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGCF-100 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | Total Cyanide, Free Cyanide, Volatile Phenols, Anionic Surfactants (LAS), Ammonia-Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfides, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HGCF-100 Cyanide |
| Price Range | USD 21,000 – 42,000 (FOB Beijing) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-100 (Volatile Phenol Configuration) |
| Instrument Type | Benchtop Laboratory Continuous Flow Analyzer |
| Compliance | GB, HJ, EPA, ISO Standard Methods |
| Sample Throughput | Batch-mode Automated Analysis |
| Detection Principle | Air-Segmented Continuous Flow with On-line Distillation and Spectrophotometric Detection |
| Optical Detection | Full-spectrum CCD or Dual-beam Silicon Photodiode Detector |
| Reaction Coil | 2 mm ID Quartz Mixing Coil |
| On-line Pretreatment | Integrated Steam Distillation, Heating, Mixing, Dilution, and Auto-Cleaning |
| Automation Level | Fully Automated Including Auto-Sampling, Reagent Dispensing, Reaction Control, Data Acquisition, and System Flush |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 / HGCF-210 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Total Cyanide, Free Cyanide, Volatile Phenol, Anionic Detergents, Ammonia Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfide, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Compliance Standards | HJ 665–2013, HJ 670–2013, HJ 667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003 |
| Optical Detection | Dual-beam silicon photodetector or full-spectrum CCD detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil | 2 mm i.d. quartz mixing coil |
| Sample Introduction | Automated sampler with carbon fiber or borosilicate glass probe, auto-cleaning and wash solution auto-replacement |
| Online Pretreatment | Integrated heating, digestion, distillation, dialysis, extraction, degassing, dilution, and mixing modules |
| Light Source | Low-power LED with short stabilization time and >10,000 h lifetime |