Water Quality Analysis
Filter
Showing 481–510 of 952 results
| Brand | Jilin University Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Water Quality Rapid Test Kit |
| Price Range | USD 140 – 7,200 (based on configuration) |
| Instrument Type | Portable |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | MAI-100G Infrared Oil Content Analyzer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0.40–100 mg/L (using 4-cm pathlength cell, standard n-hexane extract, 1:1 extraction ratio) |
| Detection Limit | < 0.1 mg/L (per JJG 950–2012 verification protocol) |
| Accuracy | ±5% RSD (at 40 mg/L standard solution) |
| Compliance | HJ 637–2018, JJG 950–2012 Class A requirements, ASTM D7066–22 (equivalent IR methodology), ISO 9377-2:2000 (Water quality — Determination of hydrocarbon oil index — Part 2: Infrared spectrometric method) |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HT-SS-I |
| Instrument Type | Portable |
| Measurement Principle | ISO 7027-compliant dual-beam infrared light scattering and absorption |
| Range | 0.1–50,000 mg/L (customizable high-range options available) |
| Accuracy | ±5% of reading (dependent on sample homogeneity) |
| Resolution | 0.01–1 mg/L (scale-dependent) |
| Sensor Material | SUS316L stainless steel |
| Host Housing | ABS+PC polymer blend |
| Sensor IP Rating | IP68 |
| Host IP Rating | IP67 |
| Operating Temperature | 0–50 °C (non-freezing) |
| Storage Temperature | −15 to 60 °C |
| Sensor Dimensions | Ø60 mm × 254 mm, 1.65 kg |
| Host Dimensions | 203 × 100 × 43 mm, 0.5 kg |
| Standard Cable Length | 3 m (extendable) |
| Display | 3.5-inch color LCD with adjustable backlight |
| Data Storage Capacity | >100,000 records |
| Power | Rechargeable Li-ion battery, USB-C charging (no battery removal required) |
| Interface | USB data export |
| Calibration Options | Standard solution calibration and field water sample calibration |
| Auto-sensor recognition | Yes |
| Sensor configuration & calibration via host | Yes |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | YN/SS-2Z |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm |
| Minimum Display Resolution | 0.01 ppm |
| Repeatability | ≤2% |
| Accuracy | ≤±5% FS |
| Power Adapter | AC 220 V, 50 Hz |
| Compliance | Designed for field-deployable water quality monitoring per standard turbidimetric principles |
| Brand | JRY |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | JRY-COD6 |
| Digestion Method | Reflux Digestion |
| Heating Module | Microcrystalline Ceramic Panel |
| Batch Capacity | 6 samples |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Digestion Vessel Capacity | 250 mL |
| Timer Accuracy | ±0.1 min |
| Dimensions (W×D×H) | 450 mm × 350 mm × 600 mm |
| Net Weight | ~15 kg |
| Rated Power | 1500 W |
| Time Setting Range | 0–999 min |
| Time to Sample Boil | <15 min |
| Brand | JTONE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JT-DCY-4SL |
| Price Range | USD 140–850 (FOB) |
| Instrument Type | Laboratory Benchtop System |
| Sample Capacity | 4 simultaneous samples |
| Gas Flow Range | 0–3 L/min (per channel, independently adjustable) |
| Temperature Control Range | Ambient to 99.9 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 1000 W |
| Display | Digital LED |
| Bath Drain Valve | Integrated quick-release |
| Lift Mechanism | Motorized vertical sample rack positioning |
| Construction | Mirror-finish 316 stainless steel |
| Compliance | Designed per GB/T 16489–1996 and HJ/T 60–2000 |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | JTSM-60 |
| Pricing | Upon Request |
| Digestion Method | Rapid Digestion |
| Heating Module | Dual Graphite Blocks |
| Batch Capacity | 60 samples |
| Temperature Range | Ambient to 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Digestion Vessel Capacity | 1 mL per well |
| Timer Accuracy | ±1 s |
| Heating Material | Isostatically Pressed High-Purity Graphite |
| Surface Coating | PTFE-Impregnated Graphite |
| Control Algorithm | PID with Auto-Tuning |
| Safety Features | Overtemperature, Overcurrent, Overvoltage, and Thermal Runaway Protection |
| Optional Accessory | Acid Gas Neutralization Unit (Condensation + Alkaline Scrubbing + Desiccant Drying) |
| Brand | JU CHUANG ENVIRONMENTAL |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Module | Single Graphite Block |
| Batch Capacity | 36 Positions |
| Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±1 °C |
| Compliance | Designed for EPA 200.2/200.7/3050B, ISO 11466, GB/T 5009.11–2003, GB/T 22105.1–2008, and ASTM D3658 |
| Brand | KC Starlight |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | XG310 |
| Price | USD 2,450 (FOB) |
| Measured Parameter | Total Phosphorus |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Spectrophotometry (Ammonium Molybdate Method) |
| Measurement Range | 0–20 mg/L |
| Accuracy | ≤ ±2% |
| Detection Limit | 0.02 mg/L |
| Resolution | 0.001 mg/L |
| Brand | KC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XG03 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.0–100.0 µg/L |
| Accuracy | ±2% F.S. |
| Detection Limit | 0.01 µg/L |
| Measurement Time | <4 min |
| Batch Capacity | 6 channels |
| Brand | Kechuang Starlight (KC) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.0–100.0 µg/L |
| Accuracy | ±2% F.S. |
| Detection Limit | 0.01 µg/L |
| Measurement Time | <4 minutes per cycle |
| Channel Capacity | 1–6 configurable channels |
| Display | 7.0-inch Windows-based HMI touchscreen |
| Sample Flow Rate | 10–40 L/h |
| Sample Temperature Range | 5–50 °C |
| Ambient Operating Temperature | 5–45 °C |
| Ambient Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤100 W |
| Dimensions (L×D×H) | 460 × 285 × 720 mm |
| Weight | 23 kg |
| Output Signals | 4–20 mA, 0–20 mA, or 0–10 mA (configurable) |
| Data Storage | Non-volatile memory with >10-year retention after power loss |
| Brand | SYSTEA |
|---|---|
| Model | LabTox |
| Measurement Principle | Bioluminescent Bacterial Toxicity Assay (using *Aliivibrio fischeri*, *Photobacterium phosphoreum*, or *Vibrio qinghaiensis* Q67) |
| Compliance | ISO 11348-3, GB/T 15441 |
| Throughput | Up to 30 samples/hour |
| Sample Capacity | 80-position carousel |
| Dilution Range | Up to 160-fold automated serial dilution (EC50 mode) |
| Dual-Parallel Testing | Blank + sample replicates (inhibition mode) |
| Integrated Cleaning Station | On-board probe and cuvette washing with programmable rinse cycles |
| Software | Windows-based control & analysis suite with audit trail, user management, and data export (CSV, PDF, Excel) |
| Brand | Lanjing |
|---|---|
| Model | LJ-201 |
| Measurement Principle | Salicylate Spectrophotometry |
| Measurement Ranges | (0–5), (0–10), (0–25), (0–50), (0–125), (0–250) mg/L NH₃–N |
| Zero Drift | ±0.02 mg/L |
| Span Drift | ±1.0% F.S. |
| Accuracy | ±8.0% at 20% F.S., ±5.0% at 50% F.S., ±3.0% at 80% F.S. |
| Limit of Quantitation | 0.15 mg/L |
| Repeatability | ≤2.0% |
| Cycle Time | ≤60 min |
| MTBF | ≥720 h |
| Insulation Resistance | >20 MΩ |
| Output Interfaces | RS232 / RS485, 4–20 mA analog |
| Dimensions | 500 × 440 × 1440 mm (L×W×H) |
| Weight | 55 kg |
| Display | 7-inch color touch screen |
| Control System | Industrial PLC |
| Operating Temperature | 5–35 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | AC 220 V ±25 V, 50 Hz ±0.5 Hz |
| Rated Power | 100 W |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | LJ-DC8000 |
| Price | USD 25,000 (FOB) |
| Measurement Principle | Enzyme-Substrate (β-D-galactosidase/ONPG) |
| Detection Range | 0–100 MPN/100 mL and 0–10,000 MPN/100 mL (extendable) |
| Sample Volume | 100 mL per analysis |
| Analysis Time | ≤24 h |
| Repeatability | ±5% |
| Accuracy (Standard Deviation) | ±20% |
| Drift | ±5% F.S. |
| Operating Temperature | 5–35 °C |
| Humidity Limit | <90% RH (non-condensing) |
| Enclosure Rating | IP66 / NEMA 4 |
| Dimensions (H×W×D) | 1675 × 630 × 610 mm (incl. reagent cabinet) |
| Power Supply | 220 V AC, auto-restart on power recovery |
| Data Storage | 100,000 records internal |
| Output Interfaces | 4–20 mA / 0–10 V analog, RS232, RS485 (Modbus RTU), Ethernet |
| Remote Capabilities | GPRS/4G, Wi-Fi, remote calibration & control |
| Sample Intake | Built-in peristaltic pump (suction head ≤2 m) |
| Reagent Consumption | 18 mL per test |
| Sample Consumption | ~100 mL per test |
| Compliance | Designed for ISO 9308-1, ASTM D5392, US EPA Method 1604, and GLP-aligned operational traceability |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LJ-DX |
| Instrument Type | Portable |
| Test Organism | Bioluminescent Bacteria (e.g., *Vibrio fischeri*, *Photobacterium phosphoreum*, *Aliivibrio qinghaiensis*) |
| Operating Temperature | +5°C to +45°C |
| Reagent Storage Temperature | −10°C to +50°C |
| Repeatability | Relative standard deviation <1% across three replicate measurements per sample |
| Assay Time | ≤15 minutes post-sample preparation |
| Spectral Response Range | 300–1100 nm |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | GB/T 15441–1995, ISO 11348-3 |
| Power Supply | AC 220 V / DC 12 V dual-mode |
| Battery | 6000 mAh Li-ion, >8 h continuous operation |
| Dimensions | 420 × 330 × 175 mm |
| Weight | 5 kg |
| Data Storage Capacity | ≥80,000 records |
| Connectivity | RJ45, Wi-Fi, 4G, Bluetooth, USB |
| Display | 7-inch capacitive touchscreen |
| Detector | Silicon Photomultiplier (SiPM) |
| Brand | Lanjing |
|---|---|
| Model | LJ-MDC |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic Instrument |
| Price | USD 13,600 (FOB) |
| Application | Enzyme-Substrate Method (Colilert®, Enterolert®, etc.) & Traditional Plate/Filtration Counting |
| Detection Targets | Total Coliforms, Fecal Coliforms, Escherichia coli, Enterococci, Pseudomonas aeruginosa, Total Viable Count (TVC) |
| Sample Formats | 51-well/97-well Quanti-Tray®, 84-well TVC tray, 90 mm Petri dishes, 45 mm membrane filters |
| Illumination | 8-channel tunable visible LED array (white + warm white), dual 365 nm narrow-band UV-LEDs |
| Imaging | 6.3 MP Sony Exmor back-illuminated CMOS sensor, 1/1.8″ format, 12-bit dynamic range, USB 3.0 interface |
| Enclosure | Fully sealed steel imaging chamber with matte black non-reflective interior |
| Data Management | Audit-trail-enabled software compliant with GLP/GMP principles, 21 CFR Part 11–ready configuration options |
| Operating System | Windows 10 Pro |
| Hardware | 13.3″ capacitive touchscreen all-in-one unit, Intel Core i7 CPU, 8 GB RAM, 512 GB SSD |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LJ-QCMn54 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Range | 0.05–5 mg/L KMnO₄ |
| Sample Volume | 100 mL |
| Sample Throughput | ≤5 min/sample |
| Detection Endpoint Resolution | 1 µL |
| Heating Temperature Accuracy | ±0.1 °C |
| Digestion Positions | 6 |
| Sample Capacity | 54 positions |
| Dimensions (L×W×H) | 1000 × 650 × 550 mm |
| Operating Ambient | 5–35 °C, 30–85% RH, 70–106 kPa, AC 220 V / 50 Hz |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LJ-TZMn |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Photometric Method (Formaldehyde Oxime & Potassium Periodate) |
| Target Analyte | Total Manganese (Mn) |
| Detection Range | 0–5 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ≤ ±5% FS |
| Stability | < 0.5% (20 min) |
| Repeatability | < 0.5% RSD |
| Optical Drift | ≤ 0.002 A in 20 min |
| Light Source | Imported High-Brightness LED with Auto-Calibration |
| Cuvette Compatibility | 10 mm, 30 mm, 50 mm rectangular cuvettes & φ16 mm round tubes |
| Display | 8-inch TFT-LCD Touchscreen (1024 × 768) |
| OS | Android 7.1.1 |
| Data Storage | 8 million records |
| Connectivity | Wi-Fi, RJ45, Bluetooth, Mobile Hotspot, USB 2.0, HDMI |
| Cloud Platform | Integrated Regulatory Compliance Cloud (LAN/WAN upload |
| Printer | Built-in Thermal Line Printer (QR code supported) |
| Power Supply | AC 220 V ±10%, 50 Hz / Optional 6 Ah Li-ion Battery |
| Dimensions | 367 × 243 × 125 mm |
| Weight | 5.3 kg |
| Operating Environment | 5–40 °C, RH < 85% (non-condensing) |
| Rated Power | 10 W |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LJ-YL01 |
| Instrument Type | Portable |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide |
| Measurement Ranges | 0.04–3 mg/L and 0.2–15 mg/L |
| Repeatability | <0.5% |
| Measurement Principle | Photometric Colorimetry (LED-based) |
| Wavelength Selection | Automatic |
| Display | 3.5-inch TFT Color Touchscreen |
| Operating System | Android-based Embedded OS |
| Data Storage Capacity | >80,000 records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Mobile Hotspot |
| Power Supply | 5 V DC / Internal 5600 mAh Rechargeable Li-ion Battery |
| Continuous Operation Time | Up to 8 hours |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Environmental Operating Range | 0–50 °C, 0–90% RH (non-condensing) |
| Optical Source | Imported Cold LED Light Source (Lifetime ≥100,000 h) |
| Compliance Reference | HJ 586–2010 |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | LJ-ZGSG |
| Instrument Type | Online Analyzer |
| Measurement Ranges | 0–30 ppb, 0–500 ppb, 0–5000 ppb |
| Accuracy | ±1% F.S. |
| Repeatability | ±1% F.S. |
| Drift | ≤±1% F.S. / 24 h |
| Response Time | 12 min (initial) |
| Sampling Cycle | ~10 min per channel |
| Sample Flow Rate | >100 mL/min |
| Sample Temperature | 10–45 °C |
| Sample Pressure | 10–100 kPa |
| Ambient Temperature | 5–45 °C |
| Relative Humidity | <85% RH |
| Reagent Consumption | ~3 L/month per reagent (3 reagents total) |
| Output | 4–20 mA (configurable, per-channel independent) |
| Alarm Output | Relay NO contact (220 VAC / 1 A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≈50 VA |
| Dimensions (H×W×D) | 720 × 460 × 300 mm |
| Panel Cutout | 665 × 405 mm |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX- Organic Halogen Combustion Furnace |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Sample Throughput | Up to 24 samples per batch (standard configuration) |
| Combustion Temperature Range | Ambient to 1100 °C (programmable, ±2 °C stability) |
| Gas Supply | Dual-gas system (N₂ for adsorption, O₂ for combustion) |
| Tube Material | High-purity quartz combustion tube (OD 15 mm, length 600 mm) |
| Integrated Scrubbing System | Five-stage acid/alkali wash bottles + dual absorption traps |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Detection Principle | High-Temperature Combustion Coupled with Ion Chromatography |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | Nitrogen-Pressurized Column Adsorption |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Analysis Time (instrumental) | 3–10 min per sample |
| Carrier Gas | O₂ ≥99.6% (recommended ≥99.999%) |
| Accessories Included | Integrated combustion furnace, quartz combustion tube, dual sample boats, quartz push rod, rubber end caps, adsorption column assembly (×2), 1.27 m silicone tubing (OD 15 mm), 5 scrubbing bottles, 2 absorption bottles, 2 absorption tubes, mounting fixtures,纱布,胶布,扎线 |
| Software Option | Real-time instrument control and quantitative data processing module (optional) |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | AOX-C |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Detection Method | Ion Chromatography (IC) of Inorganic Halides (Cl⁻, F⁻, Br⁻) after High-Temperature Combustion |
| Sample Matrix | Water (drinking, surface, groundwater, wastewater, seawater, treated effluent), sludge, sediment, soil, and waste oils |
| Key Components | Integrated furnace with built-in scrubbing system, quartz combustion tube, dual-zone oxygen supply, nitrogen-pressurized adsorption module, IC-compatible absorption train |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Origin | Zhejiang, China |
| Manufacturer | LANTIAN Instrument Co., Ltd. |
| Application | AOX determination in water and solid matrices per HJ/T 83–2001, ISO 9562:1989, and GB/T 15959–1995 |
| Detection Method | High-temperature catalytic combustion followed by alkaline absorption and ion chromatographic quantification of F⁻, Cl⁻, Br⁻ |
| Sample Types | Drinking water, surface water, groundwater, wastewater, effluent, seawater, pulp mill discharge, soil, sediment, sludge, and waste oils |
| System Configuration | Integrated furnace with built-in scrubbing system, quartz combustion tube, dual-zone oxygen supply, nitrogen-driven adsorption module, standardized absorption train, and IC-compatible sample preparation workflow |
| Compliance | Designed to support GLP-compliant AOX testing workflows |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-C |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Detection Method | High-Temperature Combustion Coupled with Ion Chromatography (IC) |
| Measurable Species | AOX (as Cl), AOCl, AOF, AOBr |
| Sample Matrices | Drinking water, surface water, groundwater, wastewater, effluent, seawater, pulp mill discharge, soil, sediment, sludge, and waste oils |
| System Configuration | Integrated furnace with built-in gas scrubbing, dual-zone combustion tube, nitrogen pressurized adsorption unit, alkaline absorption train, and IC-ready halide quantification |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | AOX-C Ion Chromatography-Based AOX Analyzer |
| Price | USD 4,200 (FOB Zhejiang) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | BioMonitor |
| Instrument Type | Online BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO)-Based Respirometric Method |
| Measurement Range | 1–50 mg/L and 1–200,000 mg/L BOD |
| Detection Limit | 1 mg/L |
| Accuracy | ±2% of reading within both ranges |
| Sample Interval | 3–4 minutes per measurement |
| Repeatability | ±2% RSD |
| Brand | LAR |
|---|---|
| Origin | Germany |
| Model | Biomonitor |
| BOD Range | 1–50 mg/L and 1–200,000 mg/L (user-selectable) |
| Measurement Interval | Every 3–4 minutes |
| Sample Preparation | Maintenance-free particle separator |
| Display | High-resolution backlit LCD |
| Data Storage | Secure SD card logging |
| Output Signals | Dual 4–20 mA (BOD and activated sludge activity) |
| Communication Interfaces | RS-232/RS-485 serial, TCP/IP Ethernet for remote monitoring and control |
| Inlet Connection | 30 mm ID tubing or M32 threaded pipe (custom options available) |
| Power Supply | 230/115 V AC, 50/60 Hz, 150 VA |
| Enclosure Rating | IP54 |
| Dimensions (W×H×D) | 600 × 862 × 540 mm (23.6 × 33.9 × 21.3 in) |
| Weight | 70 kg |
| Brand | LAR |
|---|---|
| Origin | Germany |
| Model | ToxAlarm |
| Instrument Type | Online Water Toxicity Analyzer |
| Biological Agent | Nitrifying Bacteria |
| Measurement Principle | Oxygen Consumption Rate (Respirometry) |
| Toxicity Range | 0–100% |
| Response Time | <5 minutes |
| Sample Preparation Time | 5–10 min |
| Enclosure Rating | IP54 |
| Dimensions (W×H×D) | 870 × 600 × 560 mm |
| Weight | ~70 kg |
| Power Supply | 230/115 V~, 50/60 Hz, 100 VA |
| Inlet/Outlet Tubing | 20 mm ID (6 × 1 mm & 4 × 1 mm auxiliary lines) |
| Analog Output | 0/4–20 mA |
| Serial Interface | RS232 + USB |
| Remote Access | TCP/IP (Ethernet) |
| Display | High-resolution backlit LCD touchscreen |
| Compliance | Designed for continuous operation in drinking water and surface water monitoring per DIN EN ISO 11348 and ASTM D5905 respirometric toxicity testing principles |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LawLink |
| Pricing | Available Upon Request |
