| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | SUPEC 5100 ICP-OES |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Instrument Type | Online Analyzer |
| Target Elements | Thallium (Tl), Antimony (Sb), and other regulated heavy metals in water |
| Compliance Basis | Aligns with laboratory-standard methods per ISO 17294-2, EPA Method 200.7, and GB/T 3049–2022 |
| Automation Level | Fully automated sample introduction, digestion (if integrated), nebulization, plasma excitation, spectral acquisition, background correction, QC calibration, data validation, and remote telemetry |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SUPEC 8000 |
| Pricing | Available upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EasyChem |
| Pricing | Available Upon Request |
| Technology | Discrete Batch Analysis with MPN, P/A, and TTD Detection Methods |
| Compliance | ISO 9308-2:2012 (Colilert-based), ASTM D6501, US EPA Method 1604 (adapted) |
| Sample Throughput | Up to 28 MPN tests or 56 P/A–TTD tests per unattended cycle |
| Reagent Compatibility | Colilert®-18/Colilert®-EC, Enterolert®, and other ISO-validated media |
| Sample Independence | Fully isolated incubation wells per sample |
| Integrated Cleaning Station | Automated reagent/sample line flushing and well decontamination |
| Control Interface | 7-inch industrial touchscreen with programmable assay sequences |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Model | NWP |
| Measurement Parameters | 5-parameter simultaneous in-situ analysis (e.g., NO₃⁻-N, PO₄³⁻, NH₄⁺-N, SiO₂, CODₘₙ or configurable) |
| Detection Limit | 0.001 mg/L (for key analytes) |
| Calibration | Two-point linear calibration (R² ≥ 0.995) |
| Power Supply | 13 V DC (solar-compatible) |
| Filtration Options | Self-cleaning filter cartridges (0.1 µm or 25 µm) |
| Waste Handling | Segregated toxic/non-toxic waste and effluent lines |
| Sample Wash | Deionized water–free cleaning using ambient sample water |
| Remote Operation | Full bidirectional control & real-time status telemetry via external PC |
| Environmental Rating | IP68 submersible housing for buoy, vessel, or emergency field deployment |
| Compliance | Designed to support ISO 5667-3, ASTM D511/D512/D5429/D6508, and EPA Method 300.0/353.2 workflows |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER-V with VECTRA Liquid Autosampler |
| Analytical Method | Combustion Microcoulometry |
| Measurement Range | 0–10,000 ppm |
| Accuracy | ≤2% CV |
| Detection Limit | 10 ppb |
| Resolution | ≤2% CV |
| Brand | LeadTech |
|---|---|
| Origin | Canada |
| Model | Tecta-B16 |
| Detection Principle | Enzyme-Substrate Fluorescence-Based Optical Sensing |
| Microbial Targets | Total Coliforms, Fecal Coliforms, Escherichia coli, Enterococci |
| Sample Throughput | 4 or 16 simultaneous assays |
| Detection Range | 1–10⁵ CFU/100 mL (no dilution required) |
| Limit of Detection | 1 CFU/100 mL |
| Incubation Temperature Control | 20–50 °C |
| Detection Time | 4–18 h (time-to-detection dependent on concentration) |
| Data Output | Direct display, Ethernet/Wi-Fi transmission, SMTP email alerts |
| Compliance | US EPA Method 1603 & 1604, GB/T 5750.12–2006, ISO 9308-1:2014, ASTM D6502-22 |
| Regulatory Readiness | FDA 21 CFR Part 11–compliant audit trail (software-enabled), GLP/GMP data integrity architecture |
| Brand | Tekmar |
|---|---|
| Origin | USA |
| Model | Fusion |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV Light + Sodium Persulfate |
| Measurement Range | 0.2 ppb C to 4,000 ppm C |
| Accuracy | ±1% |
| Detection Limit | 0.2 ppb C |
| Precision (RSD) | ≤1% |
| Regulatory Compliance | EPA Methods 415.1–415.3, 9060A |
| Brand | Teledyne RDI (distributed by AVVOR) |
|---|---|
| Origin | USA |
| Model | ChanneIMaster H-ADCP |
| Frequency Options | 300 kHz |
| Velocity Accuracy | ±0.5% of measured value or ±0.2 cm/s (whichever is greater) |
| Velocity Resolution | 1 mm/s |
| Velocity Range | ±5 m/s (default), ±20 m/s (max) |
| Cell Size Range | 0.25–8 m (model-dependent) |
| Maximum Profiling Range | 20–300 m (model-dependent) |
| Beam Configuration | Dual-beam, ±20° tilt, 1.5–2.2° beam divergence |
| Memory | 4 MB internal |
| Integrated Sensors | Ultrasonic water level sensor, pressure transducer, tilt sensor (pitch & roll) |
| Standard Cell Count | 128 user-configurable cells |
| Brand | Teledyne RDI |
|---|---|
| Origin | USA |
| Model | ChannelMaster H-ADCP |
| Frequency Options | 300 kHz, 600 kHz, 1200 kHz |
| Velocity Range | ±10 m/s (configurable) |
| Velocity Resolution | 0.1 mm/s |
| Depth Cell Size | 0.1–2.0 m (user-selectable, up to 128 cells) |
| Water Level Sensors | Ultrasonic (0.1–10 m, ±0.25% FS, 0.01 cm res), Pressure (0.1–10 m, ±0.5% FS, 0.1 cm res) |
| Temperature Sensor | −4 °C to +40 °C (±0.2 °C, 0.01 °C res) |
| Tilt Sensor | Dual-axis (±10°, ±0.2° @ 0°, ±0.5° @ 10°, 0.01° res) |
| Memory | 4 MB internal flash |
| Communication | RS-232, RS-422, SDI-12 v1.3 |
| Power | 10–18 VDC (typical consumption: 0.13–0.16 W |
| standby | 0.25 mW) |
| Housing | Polyurethane-cast body, titanium fasteners, stainless steel mounting frame |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 270 BT |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption Spectroscopy (IR) |
| Temperature Range | +40 to +200 °C |
| Detection Limit | < 0.2 mg/L (as reference standard for polar contaminants) |
| Accuracy | ±1.5 °C (temperature), ±2 % TPM (at +40 to +190 °C) |
| Resolution | 0.1 °C / 0.1 % TPM |
| Response Time | ~30 s |
| IP Rating | IP65 |
| Weight | 255 g |
| Dimensions (L×W×H) | 170 × 50 × 300 mm |
| Power Supply | 2 × AAA batteries (operating time ≈ 25 h / ~500 measurements) |
| Compliance | HACCP International certified, NSF registered |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Aquakem 600 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Principle | Discrete Photometric Analysis |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem200 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | Up to 180 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Maximum Reagents per Test | 4 |
| Wavelength Range | 340–880 nm |
| Barcode Reader | Integrated |
| Sample Dilution | Auto pre-dilution and auto re-dilution |
| Cadmium Reduction Module | Optional (for nitrate analysis) |
| System Architecture | Open-platform, user-definable methods, reagents, and protocols |
| Probe Function | Dual-purpose pipetting probe with integrated mixing capability |
| Wash System | Automatic internal/external probe washing |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem250 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | 250 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Maximum Reagents per Test | 4 |
| Cadmium Reduction Module | Optional |
| Barcode Reader | Integrated |
| Sample/Reagent Dispensing | Fully Automated with Internal/External Tip Washing |
| Dilution Capability | Auto Primary & Secondary Dilution |
| Stirring | Independent Stir Bars with Dedicated Wash Station |
| Reagent Flexibility | User-Defined Methods and Custom Reagent Preparation Supported |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery |
| Instrument Category | Benchtop Automated Discrete Analyzer |
| Detection Methods | Photometric (275–880 nm, 12 fixed filters), Enzymatic, Electrochemical (ISE-based pH & Conductivity) |
| Throughput | Up to 200 tests/hour |
| Sample Capacity | 9-position rack × 2 = 18 racks (162 samples) |
| reagent capacity | 6 positions × 9 slots = 54 reagent positions |
| Cuvette Format | Disposable 10-cell flexible strip cuvettes |
| Incubation | Temperature-controlled incubation disc, programmable reaction time |
| Automation Features | Integrated barcode reader, auto-dilution (primary & secondary), on-board washing station, refrigerated sample/reagent carousel |
| Power/Water | <1.5 L/h water consumption |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery Plus |
| Instrument Category | Benchtop Discrete Analyzer |
| Detection Principles | Photometric (Colorimetric), Enzymatic, and Electrochemical (ISE-based) |
| Sample Throughput | Up to 350 tests/hour |
| Wavelength Range | 275–880 nm (12 fixed-position interference filters) |
| Sample Capacity | 54 positions |
| Refrigerated Reagent Capacity | 42 positions |
| Reaction Vessel Format | 10-cell cuvette strips (up to 18 × 2 strips = 360 tests) |
| Incubation | Adjustable temperature incubation block (9 lanes × 10 positions = 90 test slots) |
| Electrochemical Module (ECM) | Integrated ISE-based pH and conductivity measurement |
| Sample Handling | Dual independent probes (sample + reagent), dedicated wash station, barcode reader |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Power & Utility | <2.5 L/h water consumption |
| Software Compliance | Audit-trail enabled, user-access control, electronic signature support per FDA 21 CFR Part 11 |
| Regulatory Alignment | Designed to support ISO/IEC 17025, ASTM D1293 (pH), ASTM D1125 (conductivity), EPA 365.3 (phosphate), USP <731>, and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2111EL |
| Instrument Category | Sodium Ion Analyzer |
| Installation Type | Online |
| Measurement Range | 0.001 ppb – 10 ppm |
| Response Time | ≤2 min to 95% of final value |
| Accuracy | ±5% of reading or ±0.1 ppb (whichever is greater) |
| Operating Temperature | 5–45 °C |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TE-1050 |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet Fluorescence Spectrophotometry |
| Measurement Range | 40 ppb – 100 ppm |
| Detection Limit | 5 ppb |
| Accuracy | < ±5% |
| Resolution | 0.001 ppm |
| Measurement Cycle | 5 seconds per analysis |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TE-2000 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Flow-through Microbial Electrode Method |
| Measurement Range | 2–4000 mg/L |
| Detection Limit | 2 mg/L |
| Accuracy | ≤5% |
| Single-sample Measurement Time | 8 min |
| Repeatability | 3% |
| Sample Volume | 50 mL |
| Operating Ambient Temperature | 5–40 °C |
| Data Storage Capacity | 1,000,000 records |
| Display | 8-inch Color TFT Touchscreen |
| Communication Interfaces | USB, RS-232 |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 530 × 360 × 200 mm |
| Microbial Membrane Shelf Life | ≥30 days post-activation (1-year unopened warranty) |
| Oxygen Supply | Liquid-permeation-resistant automatic oxygenation design |
| Brand | Tianer |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TE-5002 |
| Measurement Parameters | Total Phosphorus (TP) and Total Nitrogen (TN) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Spectrophotometry (for TP/TN digestion–colorimetric method) |
| Measurement Range | 0–100 mg/L for both TP and TN |
| Accuracy | ≤ ±5% |
| Detection Limit | 0.01 mg/L |
| Resolution | 0.001 mg/L |
| Repeatability | ≤ ±2% |
| Optical Stability | ≤ ±0.005 Abs/20 min |
| Optical System | Fiber-optic Photometric Detection |
| Light Source | Imported Cold Light LED (Lifespan > 100,000 h) |
| Display | 8-inch HD Capacitive Touchscreen |
| Interface Language | Default Chinese |
| Detection Modes | Rotating Cuvette (360°), 10 mm & 30 mm Cuvette, Digital Electrode Ports (2 independent) |
| Readout Modes | Concentration (mg/L), Absorbance (Abs), Transmittance (%) |
| Calibration | Single-point and Multi-point Calibration |
| Pre-stored Curves | 180 Method-Specific Calibration Curves (incl. EPA, ISO, and HJ standards) |
| Data Storage | Up to 1,000,000 Records with Timestamp, Sample ID, Operator ID, and Method Tag |
| Data Export | USB Port + Built-in Thermal Printer |
| Housing Material | Flame-Retardant ABS with Corrosion-Resistant Surface Finish |
| Dimensions (W×D×H) | 392 × 315 × 170 mm |
| Weight | 4.4 kg |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | TE-5105G |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Colorimetric Method (Nessler Reagent Spectrophotometry) |
| Measurement Range | 0.01–150 mg/L (multi-range segmented calibration) |
| Accuracy | ≤ ±5% |
| Detection Limit | 0.01 mg/L |
| Measurement Time | 15–20 min per batch |
| Throughput | 5 simultaneous sample positions |
| Optical System | Fiber-optic spectrophotometric system |
| Light Source | Imported 12 V / 20 V halogen lamp (rated lifetime ≥ 100,000 h) |
| Wavelength | 420 nm |
| Reference Channel | Fixed automatic reference channel |
| Repeatability | ≤ ±2% |
| Inter-channel Variation | ≤ ±2% |
| Display | 7-inch color TFT capacitive touchscreen |
| Sample Introduction | Automated multi-channel sampling module |
| Sample Formats | Pre-filled colorimetric tubes (liquid reagents) and cuvettes (powder reagents) |
| Data Storage | Up to 1,000,000 measurement records with timestamp, sample ID, and operator log |
| Preloaded Calibration Curves | 180 factory-validated curves (user-modifiable, extensible, and recalibratable) |
| Auto-calibration | Built-in self-calibration routine using reference standards |
| Data Output | Integrated thermal printer |
| Connectivity | USB 2.0 port + RS-232 serial interface |
| Compliance | Fully aligned with HJ 535–2009 “Water Quality — Determination of Ammonia Nitrogen — Nessler Reagent Spectrophotometric Method” |
| Brand | TIANER |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Rapid Digestion Spectrophotometry (Lab-Grade) |
| Wavelength Range | 340–900 nm |
| COD Range | 2–20,000 mg/L |
| Accuracy | ≤ ±5% |
| Repeatability | ≤ ±2% |
| LOD | 0.01 mg/L |
| Digestion Time | 30 min |
| Batch Capacity | 8 samples |
| Display | 7-inch color capacitive touchscreen |
| Data Storage | 1,000,000 measurement records |
| Preloaded Calibration Curves | 1,000 |
| Optical System | Fiber-optic detection with imported cold-light source (≥100,000 h lifetime) |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 4 nm |
| Resolution | 0.001 AU |
| Dual-Zone Digestion Block | 8-position, independently controlled (0–200 °C) |
| Power | Integrated 40,000 mAh Li-ion battery |
| Connectivity | USB, RS232, optional Bluetooth |
| Compliance | ISO 9001 & ISO 14001 certified |
| Software | Proprietary water quality analysis platform (registered copyright) |
| Brand | Tianhe (Shandong Tianhe Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TH-SS15S |
| Detection Principle | Chlorophyll-a Fluorescence Method |
| Measurement Range | 0–400 µg/L |
| Resolution | 0.01 µg/L |
| Accuracy (Linearity) | R² > 0.999 |
| Temperature Compensation | Automatic |
| Self-Cleaning Function | Integrated Brush-Based Cleaner with Configurable Interval & Cycles |
| Power Consumption | 0.7 W (Operating), 0.4 W (Standby) |
| Supply Voltage | DC 12–24 V |
| Output Interface | RS-485 (Modbus RTU Protocol) |
| Storage Temperature | –5 to 65 °C |
| Operating Environment | 0 to 50 °C, < 0.2 MPa |
| Installation | Submersible, 3/4″ NPT Thread |
| Cable Length | 5 m |
| Protection Rating | IP68 |
| Housing Material | 316L Stainless Steel |
| Calibration Method | Two-Point (Zero & Span) via PC Software or Modbus Commands |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0.1–10 mg/L (multi-segment calibration) |
| Repeatability | ≤5% RSD |
| Accuracy | ±5% of reading |
| LOD | 0.4 mg/L |
| Resolution | 0.01 mg/L |
| Single-Test Duration | 13 min (water bath heating) |
| Display | Backlit LCD with keypad interface |
| Data Storage | 30,000 measurement records with power-loss protection |
| Calibration Curves | 1 built-in standard curve + 96 user-defined curves |
| Connectivity | Ethernet port + USB 2.0 |
| Output | Integrated thermal printer |
| Light Source | Imported long-life cold LED (rated lifetime: 100,000 h) |
| Operating Modes | Standard mode / Continuous measurement mode |
| Reagent Compatibility | Dedicated pre-packaged CODMn test kits (ISO/GB-compliant) |
| Brand | Timepower |
|---|---|
| Model | TP107 |
| Type | Online Analyzer |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Measurement Principle | Vanadomolybdophosphoric Yellow Colorimetry (Acidic Medium) |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Range Options | 0.00–20.00 mg/L or 0.00–50.00 mg/L |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | ≤±1% F.S./24 h |
| Response Time | < 4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Suspended Solids | < 5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable) |
| Alarm Outputs | Independent per channel (flow loss, high/low limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Compliance | GB/T 6913–2008 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Benchtop Laboratory Analyzer |
| Model | TP306 |
| Measurement Principle | Molybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED (peak λ = 650 nm ± 5 nm) |
| Detection Range | 0–200 µg/L SiO₂ (extendable to 1000 µg/L via dilution) |
| Resolution | 0.1 µg/L |
| Accuracy | ±2% FS or ±1 µg/L (whichever is greater) |
| Repeatability | ≤1.5% RSD |
| Blank Calibration | Automatic zero-point and electronic drift compensation |
| Data Storage | Cyclic memory for up to 256 test records |
| Power Supply | AC 220 V ± 10%, 50/60 Hz |
| Dimensions | 320 × 240 × 180 mm |
| Weight | 4.2 kg |
| Compliance | Designed per GB/T 12149–2019 (Chinese Standard for Silica Determination in Boiler Water and Feedwater), ASTM D859–22 (Standard Test Method for Silica in Water), and ISO 10523:2022 (Water Quality — Determination of pH) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP310 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameter | pH |
| Measurement Range | 0.00–14.00 pH |
| Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Input Impedance | ≥1×10¹² Ω |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Compensation Range | 0–60 °C |
| Temperature Sensor | Pt1000 |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25–55 °C (electrode excluded |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤5 W |
| Dimensions | 200 × 200 × 85 mm |
| Weight | 2.1 kg |
| Display | 5.0-inch capacitive color touchscreen, Chinese UI |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ACOD-30 |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Dichromate Oxidation with Automated Potentiometric/Colorimetric Endpoint Detection (Compliant with HJ 828–2017) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | APIA-100 |
| Pricing | Available Upon Request |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Instrument Type | Laboratory Benchtop Analyzer |
| Repeatability | RSD ≤ 3.0% |
| Limit of Detection | ≤ 0.05 mg/L |
| Brand | Tongtai Lian (TTL) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | TTL-6HS |
| Instrument Type | Laboratory Benchtop System |
| Compliance | Designed per HJ 1226–2021 (PRC National Ecological and Environmental Standard) |
| Construction Materials | 316 Stainless Steel Frame + PTFE-Coated Components |
| Heating Method | Integrated Constant-Temperature Water Bath |
| Sample Capacity | 6 Independent Reaction Vessels |
| Gas Control | Individual Mass Flow Regulation per Channel (N₂) |
| Vertical Travel Range | 100 ± 2 mm |
| Sample Rack | Rotatable Circular Platform with Radial Mounting |
| Drainage | Stainless Steel Ball Valve |
| Electrical Isolation | Separated Water Bath and Control Unit Architecture |
| Corrosion Resistance | Certified for HCl, H₂SO₄, and NaOH Exposure (pH 1–14, ≤80 °C) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Import Status | Imported |
| Model | Tox protectII |
| Instrument Type | Online Monitoring System |
| Test Organism | Live Fish (e.g., Danio rerio or Oncorhynchus mykiss) |
| Operating Temperature Range | 5–28 °C |
| Measurement Chamber Volume | 9 L (customizable) |
| Detection Principle | Real-time optical grating-based behavioral activity monitoring |
| Communication Interfaces | RS-485, Ethernet, Modbus TCP, optional GSM/SMS and analog alarm outputs |
| Alarm Modes | Local visual (tricolor LED), audible, remote SMS/fax/email via integrated gateway |
| Compliance | Designed for GLP-aligned operation |