| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GP8200MAS |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH / ORP / Free Chlorine / Turbidity / Dissolved Oxygen (DO) / Electrical Conductivity |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GP8200MAS |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, ORP, Free Chlorine, Turbidity, Dissolved Oxygen (DO), Electrical Conductivity (EC) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer | GreenPrima Ltd. |
| Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameters | Free Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm / 0–20.00 ppm |
| Accuracy | ±0.001 ppm / ±0.01 ppm |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| LOD | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000, manual/auto) |
| Operating Temp. | 0–70 °C |
| Storage Temp. | -20 to 70 °C |
| Display | Backlit dot-matrix LCD |
| Language | English / Chinese menu |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Enclosure Rating | IP65 |
| Communications | RS485, MODBUS-RTU compliant |
| Analog Outputs | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Range | 0–2.000 / 0–20.00 ppm |
| Sensor Accuracy | ±2% FS |
| Electrode Material | Glass body with dual platinum ring working electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Connection | PG13.5 threaded fitting |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 820 2I |
| Instrument Type | Online |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Measurement Range | 0.00–20,000 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic, NTC30K or PT1000) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.) |
| Communication | RS485 Modbus RTU |
| Cleaning Cycle | 0.1–1000 h adjustable |
| cleaning duration | 1–1000 s adjustable |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 820 2I |
| Price | Upon Request |
| Measurement Range | 0.00–20,000 ppm Ca²⁺ (as CaCO₃ equivalent) |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Isolated Analog Outputs | Two 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1 % FS) |
| Communication | RS485 Modbus RTU |
| Cleaning Cycle | 0.1–1000 h (adjustable) |
| cleaning duration | 1–1000 s (adjustable) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, with hysteresis setting) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PM 820 D |
| Instrument Type | Online |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0.00–20.00 ppm |
| Accuracy | ±0.01 ppm |
| Resolution | 0.01 ppm |
| Temperature Compensation | -10–130 °C (NTC30K/PT1000, manual or automatic) |
| Operating Temperature | -10–70.0 °C |
| Storage Temperature | -20–70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Output | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting | Wall-mounted, pipe-mounted, or panel-mounted |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200 |
| Price Range | USD 1,400 – 7,000 (FOB UK) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200I |
| Detection Range | 0–30,000 mg/L Cl⁻ |
| Detection Limits | 0.01 / 0.1 / 1 ppm |
| Response Time | ≤30 s |
| Measurement Accuracy | ±0.01, ±0.1, or ±1 ppm (selectable resolution-dependent) |
| Operating Temperature | 0–70 °C |
| Temperature Compensation Range | −10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Dual isolated 4–20 mA |
| Relay Output | 1 multifunctional relay (for cleaning control, periodic alarm, fault alarm) |
| Data Storage | 600,000 timestamped records |
| Display | Backlit high-contrast dot-matrix LCD with adjustable contrast |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Electrode Model | Bsens720 |
| Electrode Material | Polyphenylsulfone (PPS) |
| Max. Pressure Rating | 3.5 bar |
| Cable Length | 5 m |
| Compatible Media | Potable water, boiler feedwater, pharmaceutical water, industrial effluent |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200I |
| Price Range | USD 1,400 – 7,000 (FOB UK) |
| Measurement Range | 0.00–20,000 ppm CaCO₃ equivalent |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input, manual/automatic) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit graphic LCD (128 × 64 pixels) |
| Data Storage | 600,000 records with timestamped retrieval |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS RTU protocol |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Relay Output | One multifunction programmable relay (cleaning trigger, fault alarm, periodic alert) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Compatible Electrode | GreenPrima Bsens740 hardness sensor (range: 0–40,000 mg/L as CaCO₃, resolution: 0.01 mg/L, accuracy: ±3% FS, PPS body, max. pressure: 3.5 bar, NTC10K temp. sensor integrated, 5 m cable, PG13.5 thread) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200I |
| Measurement Principle | Ion-Selective Electrode (Ca²⁺/Mg²⁺) |
| Range | 0.00–20,000 ppm as CaCO₃ |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor) |
| Operating Temp. | 0–70 °C |
| Storage Temp. | -20 to 70 °C |
| Display | Backlit dot-matrix LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS) |
| Communication | RS485, MODBUS RTU protocol |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens740 |
| Sensor Range | 0–40,000 mg/L as CaCO₃ |
| Sensor Resolution | 0.01 mg/L |
| Sensor Accuracy | ±3% FS |
| Sensor Material | Polyphenylsulfone (PPS) |
| Max. Pressure | 3.5 bar |
| Cable Length | 5 m |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200I |
| Price Range | USD 1,400 – 7,000 (FOB UK) |
| Measurement Range | 0.00–20,000 ppm CaCO₃ equivalent |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | −10 to 130 °C (manual/automatic |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | −20 to 70.0 °C |
| Display | Backlit graphic LCD (128 × 64 pixels) |
| Data Storage | 600,000 records with timestamped retrieval |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS RTU protocol |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Relay Output | One multifunctional relay (configurable for cleaning control, periodic alarm, fault alarm) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Electrode Model | Bsens740 |
| Electrode Range | 0–40,000 mg/L as CaCO₃ |
| Electrode Resolution | 0.01 mg/L |
| Electrode Accuracy | ±3% FS |
| Electrode Body Material | Polyphenylsulfone (PPS) |
| Electrode Max. Pressure | 3.5 bar |
| Electrode Temp. Range | −5 to 70.0 °C |
| Electrode Connection | PG13.5 threaded fitting |
| Cable Length | 5 m |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Model | PM 8200S |
| Measurement Principle | Infrared Monochromatic Light Scattering |
| Range | 0.00–4000.00 NTU / 0.00–4500.00 mg/L |
| Resolution | 0.1 NTU (display), 0.01–1 NTU/mg/L (sensor) |
| Accuracy | ±2% F.S. |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | −20–70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max 500 Ω, 0.1% F.S.) |
| Communication | RS485, MODBUS RTU protocol |
| Relay | 1 multifunctional relay (cleaning, periodic alarm, fault alarm) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Mounting | Wall-mount, pole-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens580 |
| Sensor Material | PVC & Delrin |
| Max Pressure | 5 bar |
| Cable Length | 7 m |
| Response Time | <1 s |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202 D |
| Instrument Type | Online |
| Measurement Principle | Electrochemical Probe — Polarographic |
| Measurement Range | 0.00–20.00 ppm, 0.00–200.00 ppb |
| Accuracy | ±0.02 ppm |
| Resolution | 0.001 ppm, 0.01 ppb |
| Temperature Compensation | –10 to 130 °C (manual/automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English/Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS, configurable for DO or temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Cycle | 0.1–1000 h adjustable |
| cleaning duration | 1–1000 s adjustable |
| Alarm Outputs | Two independent Hi/Lo relay alarms (5 A / 250 VAC / 30 VDC, with hysteresis setting) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mounted, panel-mounted, pipe-mounted |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Cut-out Size | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202C L |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemistry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to +130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω) |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202C L |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Detection |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm (Cl₂), 0.00–200.00 ppb (ClO₂/O₃) |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm (for ppm range), 0.01 ppb (for ppb range) |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Cycle | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Accuracy | ±2% of Full Scale |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω) |
| Cleaning Control | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-mount, panel-mount, in-line pipe mount |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to +130 °C (NTC10K or PT1000 sensor support) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Constant Voltage |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-mounted, Pipe-mounted, Panel-mounted |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Constant Potential (Constant-Voltage Amperometry) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Manufacturer |
| Model | PM 8202D |
| Instrument Type | Online |
| Measurement Principle | Electrochemical (Polarographic) Probe |
| Measurement Range | 0–20 ppm |
| Accuracy | ±2% FS |
| Repeatability | ±2% FS |
| Detection Limit | 0.01 ppm |
| Temperature Compensation | Automatic NTC (22 kΩ) |
| Pressure Compensation Range | 600–1100 mbar |
| Salinity Compensation Range | 0.0–45.1 ppt |
| Operating Temperature | −10.0 to +60.0 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Display | Backlit LCD (44 × 65 mm, yellow) |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Output Signals | Two isolated 4–20 mA outputs (configurable, max. 600 Ω) |
| Relay Outputs | Two SPDT relays (5 A / 250 VAC, 5 A / 30 VDC), independently programmable Hi/Lo with hysteresis |
| Enclosure Rating | IP65 |
| Mounting | Panel mount (cutout: 136 × 136 mm) |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.8 kg |
| Compatible Sensor | GreenPrima BSens 420 Maintenance-Free DO Electrode |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202D |
| Instrument Type | Online Analyzer |
| Measurement Principle | Polarographic Electrochemical Sensor (Clark-type) |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Accuracy | ±0.02 ppm / ±0.02 ppb |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD (Chinese/English bilingual) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S., configurable for DO or temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Control Output | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay alarms (5 A / 250 VAC / 30 VDC, hysteresis adjustable) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, pipe-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Cut-out Size | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8202D |
| Instrument Type | Online Analyzer |
| Measurement Principle | Polarographic Electrochemical Sensor (Clark-type) |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±0.02 ppm / ±0.02 ppb |
| Detection Limit | 0.001 ppm / 0.01 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Temperature Compensation | -10 to 130 °C (manual or automatic, NTC10K/PT1000 compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD (Chinese/English interface) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1 % FS, configurable for DO or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay alarms (5 A / 250 VAC / 30 VDC, with hysteresis setting) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, pipe-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Cutout Size | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202I |
| Instrument Type | Online |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Measurement Range | 0.00–20,000 ppm NH₃–N |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Resolution | 0.01 / 0.1 / 1 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485 Modbus RTU |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202I |
| Instrument Type | Online Analyzer |
| Ion Measured | Ammonium/NH₃-N |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 0.1 mg/L |
| Response Time | 5 min |
| Measurement Accuracy | ±5% F.S. |
| Operating Temperature Range | 0–80 °C |
| Resolution | 0.01 mg/L |
| Temperature Compensation | -10–130 °C (NTC10K/PT1000, manual/auto) |
| Display | Backlit dot-matrix LCD |
| Communication | RS485 Modbus RTU (HART optional) |
| Output | Dual isolated 4–20 mA (max 500 Ω, 0.1% F.S.) |
| Alarm Outputs | 2 independent Hi/Lo relays (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Sensor Model | Bsen730 |
| Electrode Material | PPS |
| Max Pressure Rating | 3.5 bar |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PM 8202O |
| Instrument Type | Online |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0.00–20.00 ppm |
| Accuracy | ±0.01 ppm |
| Resolution | 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS), configurable for DO and temperature |
| Communication | RS485 Modbus RTU |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC, with hysteresis) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Cutout Size | 138 × 138 mm |
| Weight | 0.87 kg |
| Electrode Material | 316L stainless steel |
| Optional Feature | Air-driven self-cleaning module |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM820 2C L |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemistry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM820 2CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM820 2CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor support) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output Signals | Dual isolated 4–20 mA (0.1% FS accuracy, max loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM820 2CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS), RS485 Modbus RTU |
| Relay Outputs | Two programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PM8200 S |
| Instrument Type | Online |
| Measurement Principle | 90° Near-Infrared Light Scattering |
| Compliance | EN ISO 7027 |
| Sensor Type | Bsens580 High-Turbidity Sensor |
| Measuring Range | 5–4000 NTU / 0–4500 mg/L (as SS) |
| Resolution | 0.01–1 NTU (or mg/L) |
| Accuracy | < ±5% of reading |
| Temperature Compensation | NTC10K or PT1000, -10 to 130 °C (manual/automatic) |
| Operating Temperature (Controller) | 0–70 °C |
| Operating Temperature (Sensor) | 0–50 °C |
| Storage Temperature | -20 to 70 °C |
| Max. Pressure (Sensor) | 5 bar |
| Sensor Housing | IP68 |
| Controller Enclosure | IP65 |
| Display | Backlit dot-matrix LCD with Chinese/English menu |
| Output | Dual isolated 4–20 mA (0.1% FS, max. 500 Ω), RS485 Modbus RTU (HART optional) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (Controller) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight (Controller) | 0.86 kg |
| Sensor Dimensions | Ø27 × 170 mm |
| Standard Cable Length | 7 m |