| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Electrode Options | Gold, Mercury-plated, Bismuth-plated, and Bare Carbon Working Electrodes |
| Max Simultaneous Metals | 5 per module (up to 2 modules) |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces |
| Compliance | Designed for continuous unattended operation in compliance with ISO 10560, ASTM D3559, and EPA Method 7063 for trace metal analysis in aqueous matrices |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for EPA Method 200.8, ISO 11969, and ASTM D3559/D3590 compatibility |
| Environmental Rating | IP65 enclosure with humidity-resistant internal architecture |
| Calibration | Automated on-board standard addition and multi-point calibration routines |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | HM-1000, AVVOR-8000, AVVOR-9000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Tl, Fe, Ni, Sn, Cr, Cr(VI), Co, Mo, Au, Ag, Pd, U |
| Configuration | Dual-module support (up to 5 simultaneous metals per module) |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces |
| Compliance | Designed for continuous unattended operation in industrial effluent, municipal wastewater, surface water, groundwater, drinking water and seawater applications |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11929, USP <232>/<233>, EPA Method 7000B & 7473 |
| Environmental Certification | IP65 enclosure, NEMA 4X-rated housing |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max Modules | 2 |
| Max Simultaneous Parameters per Module | 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> guidance |
| Environmental Rating | IP65 Enclosure with Humidity Control |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 metals/module |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11047, USP <232>/<233>, EPA Method 7000B |
| Enclosure Rating | IP65 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Sample Inlet | 6–8 mm OD tubing, pressure-rated for continuous flow |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance Support | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, EPA Method 7000B (ASV-based), GLP/GMP-ready data logging |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Modules | 2 |
| Simultaneous Parameters per Module | Up to 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for EPA Method 7063, ISO 11969, ASTM D3559, and GLP/GMP-aligned data integrity protocols |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Price | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–10 mg/L Cl₂ |
| Cycle Time | 110 s–10 min (adjustable) |
| Accuracy | ±5% or ±0.03 mg/L Cl₂ (0–6 mg/L) |
| Resolution | 0.01 mg/L |
| Method | EPA-approved DPD colorimetric analysis for free chlorine and total chlorine |
| Output | 4–20 mA analog + RS-485 with Modbus RTU protocol |
| Alarms | Two user-configurable concentration-based digital alarms |
| Operating Temperature | 5–40 °C |
| Inlet Pressure | 5–150 psi |
| Enclosure Rating | NEMA 4X / IP66 |
| Housing Material | ABS plastic |
| Power Supply | 100–240 V AC, auto-ranging, 47–63 Hz |
| Certifications | CE, UL, CSA, ETL, ETLc |
| Dimensions (L×W×H) | 41 × 41 × 26 cm |
| Weight | 3.6 kg |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–10 mg/L Cl₂ |
| Cycle Time | 110 s – 10 min (user-selectable) |
| Accuracy | ±5% or ±0.03 mg/L Cl₂ (whichever is greater) for 0–6 mg/L |
| Resolution | 0.01 mg/L |
| Method | EPA-Approved DPD Colorimetric Analysis |
| Output | 4–20 mA analog + RS-485 with Modbus RTU protocol |
| Alarms | Two user-configurable concentration-based digital alarms |
| Operating Temperature | 5–40 °C |
| Inlet Pressure | 5–150 psi |
| Enclosure Rating | NEMA 4X / IP66 |
| Housing Material | ABS plastic |
| Power Supply | 100–240 V AC, auto-ranging, 47–63 Hz |
| Certifications | CE, UL, CSA, ETL, ETLc |
| Dimensions (L×W×H) | 41 × 41 × 26 cm |
| Weight | 3.6 kg |
| Brand | AVVOR |
|---|---|
| Model | 9000-1 |
| Origin | Fujian, China |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0.1–5 mg/L (standard), optional 0–20 / 0–50 / 0–100 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ±0.1 mg/L |
| Repeatability | ±0.5% RSD |
| Resolution | 0.1 mg/L |
| Cycle Time | 30 min per analysis |
| Compliance | GB 11892–1989, HJ/T 100–2003 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000-CODmn |
| Measurement Method | Potassium Permanganate Oxidation–Redox Titration (ISO 8467, GB 11892–1989, HJ/T 100–2003) |
| Range | 0–20 mg/L (standard), optional 0–50 mg/L and 0–100 mg/L |
| LOD | 0.05 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ≤ ±3% |
| Sample Matrix | Drinking water and surface water with chloride < 300 mg/L |
| Compliance | Designed for GLP-compliant laboratories |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000-CODmn |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AVVOR 9000 NH4-N |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia Gas-Sensing Electrode Method |
| Measurement Range | 0.05–1000 mg/L (multi-range configurable) |
| Accuracy | ±3% FS |
| Detection Limit | 0.01 mg/L |
| Measurement Cycle | 5 min per sample |
| Batch Capacity | 10 samples |
| Compliance | HJ/T 101–2003 (China EPA Standard) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LawLink |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Germany |
| Model | TresCon OA110 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia-Selective Gas-Sensing Electrode |
| Measurement Range | 0.01–2 mg/L NH₄–N |
| Accuracy | ±0.5% of reading |
| Detection Limit | 0.1 mg/L NH₄–N |
| Cycle Time | 30 min |
| Batch Capacity | 10 samples per cycle |
| Brand | Azure Cloud & Wind Confluence |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-CQC10 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Parameters | Velocity, Depth, Flow Rate, Temperature |
| Flow Range | 0.01–6.50 m/s |
| Velocity Accuracy | ±1.0% ± 1.2 cm/s |
| Velocity Resolution | 0.75 mm |
| Water Temperature Range | Not specified (standard ambient range) |
| Temperature Accuracy | ±0.8 °C |
| Water Level Range | 0–10 m |
| Level Accuracy | ±0.2% ± 0.2 cm |
| Flow Rate Range | 1 L/s – 99,999,999 m³/h |
| Power Supply | Internal Li-ion battery |
| Communication | RS485, Modbus RTU protocol |
| Data Storage | 100,000 records |
| Measurement Modes | Manual & automatic (interval configurable from 0 to 120 min in 5-min increments) |
| velocity averaging duration | 10–120 s (auto), 60/100 s (manual) |
| Physical Configuration | Portable host unit with submersible sensor, telescoping pole (2 m standard, customizable extension) |
| Display | Backlit LCD |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A-ToxII |
| Instrument Type | Online |
| Test Organism | Algae (Chlorella vulgaris, ISO 8692:2012 compliant) |
| Operating Temperature | 0–35 °C |
| Reagent Storage Temperature | 0–30 °C |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Imported Instrument |
| Model | Algae Torch Online |
| Application | Real-time in-situ chlorophyll a and phycocyanin quantification in natural and engineered water systems |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Algae Torch |
| Measurement Parameters | Total Chlorophyll a (0–500 µg/L), Cyanobacterial Density, Turbidity (0–200 NTU), GPS Coordinates |
| Detection Time | <20 s |
| Resolution | 0.1 µg/L (Chl-a) |
| LOD | 0.15 µg/L |
| Excitation Wavelengths | 470 nm, 526 nm, 610 nm |
| Weight | 1.3 kg |
| Dimensions (H × Ø) | 500 mm × 60 mm × 68 mm |
| Power Supply | Internal Rechargeable Battery (AC Adapter: 110/240 V, 50/60 Hz) |
| Operating Temperature | 0–35 °C |
| Storage Temperature | 0–50 °C |
| IP Rating | IP68 |
| Depth Rating | 10 m (standard), 100 m (optional version) |
| Data Storage | 2000 measurements |
| Interface | USB |
| Software | bbe++ for Windows |
| Accessories | 10-m rope, telescopic pole, nylon backpack, underwater data cable extensions (10–30 m), sensor performance kits |
| Brand | BBE Moldaenke |
|---|---|
| Model | AlgaeTorch |
| Measurement Principle | In-situ algal pigment fluorescence detection (excitation at 470 nm, 525 nm, 610 nm) |
| Parameters | Total chlorophyll a / total algal density / cyanobacteria concentration |
| Range | 0–500 µg Chl-a/L |
| Response time | <20 s |
| Resolution | 0.1 ng Chl-a/L |
| Accuracy | ±0.015 ng Chl-a/L (total algae) |
| LOD | 0.1 µg Chl-a/L (single-species cyanobacteria) |
| Turbidity compensation | 0–200 FTU |
| Operating temperature | 0–35 °C |
| Depth rating | AlgaeTorch 10 (10 m), AlgaeTorch 100 (100 m) |
| Protection class | IP68 |
| Dimensions | 500 × 60 mm (H × Ø) |
| Weight | 1.3 kg |
| Power supply | 12 V DC (internal rechargeable battery) |
| Data interface | USB |
| Memory capacity | 2000 measurements |
| Software | bbe++ for Windows |
| Optional accessories | telescopic pole, shoulder strap, 10 m tether cable, probe performance kit |
| GPS module | integrated |
| Data output formats | ASCII, Excel (.xlsx), plain text |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | AOA |
| Application | Real-time online chlorophyll a and phytoplankton group quantification |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BG00750001 |
| Instrument Type | Online Volatile Phenol Analyzer |
| Output Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, Ethernet (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Model | BG00750002 |
| Communication Options | 4–20 mA output, RS232/RS485 serial interface, MODBUS RTU/TCP, TCP/IP (optional) |
| Automation Features | Fully automated analysis cycle, programmable measurement interval, auto-cleaning, auto-calibration (manual calibration supported), power-loss recovery with automatic restart |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BG00750003 |
| Instrument Type | Benchtop |
| Analyte | Chloride Ion |
| Measurement Range | 0.1 mg/L |
| Limit of Detection (LOD) | 0.8 mg/L |
| Response Time | 10 min |
| Measurement Accuracy | ≤2% |
| Operating Temperature Range | 0–45 °C |
| Communication Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic (China-Made) |
| Model | bbe Cn-PWR II |
| Instrument Type | Online Analyzer |
| Communication Options | 4–20 mA analog output, RS232/RS485 serial interface, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method (Online) |
| Wavelength | 600 nm (standard for Cr(VI)/Cr(III) absorbance ratio) |
| Measurement Range | 10–500 mg/L, 10–1000 mg/L, or 10–1500 mg/L (user-selectable range switching) |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ ±5% RSD |
| Limit of Detection (LOD) | 10 mg/L COD |
| Cycle Time | 30 minutes per analysis |
| Sample Volume per Cycle | 1.5–3 L |
| Compliance | Designed to meet ISO 6060 and EPA Method 410.4 requirements for online COD monitoring |